Loading...
HomeMy WebLinkAboutR-4214217r N O 0 W Iwo L0 O 0 0 0 0 J 0 0 ry 6 U M J M U O � m CO L0CL M LO Lo Ln N O M O U O N �4w 0 MO NOf 0 O mom � � o 6 U �i��w wQ C) 0- x SITE SPECIFIC DATA PROJECT NUMBER 14053 PROJECT NAME RAPIDRIDE I LINE PROJECT LOCATION RENTON, WA STRUCTURE ID TREATMENT (1-2) TREATMENT REQUIRED VOLUME BASED (CF) FLOW BASED (CFS) 0.08 PEAK BYPASS REQUIRED (CFS) - IF APPLICABLE 0.499 PIPE DATA I.E. MATERIAL DIAMETER INLET PIPE 1 28.51 DI 12" OUTLET PIPE 27.18 CPE 12" PRETREATMENT BIOFILTRATION DISCHARGE RIM ELEVATION 32.68 32.68 32.68 PEAK HGL 29.17 29.17 29.17 SURFACE LOAD HS-20 HS-20 HS-20 FRAME & COVER 030" 030" N/A WETLAND MEDIA VOLUME (CY) 3.56 ORIFICE SIZE (DIA. INCHES) 4 EA 00.77" TREATMENT FLOW (CFS) 0.08 OPERATING HEAD (FT) 1.33 PRETREATMENT LOADING RATE (GPM/SF) 1.2 WETLAND MEDIA LOADING RATE (GPM/SF) 0.84 GENERAL NOTES: 1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT MANUFACTURER. INSTALLATION NOTES: 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT, MATERIALS AND INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS' SPECIFICATIONS, UNLESS OTHERWISE STATED IN MANUFACTURER'S CONTRACT. 2. UNIT MUST BE INSTALLED ON A MINIMUM 6" LEVEL ROCK BASE. 3. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL PIPES SHALL BE SEALED WATERTIGHT PER MANUFACTURER'S STANDARD CONNECTION DETAIL. 4. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL PIPES, RISERS, MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 5. CONTRACTOR RESPONSIBLE FOR CONTACTING MANUFACTURER FOR ACTIVATION OF UNIT. MANUFACTURER'S WARRANTY IS VOID WITHOUT PROPER ACTIVATION BY A MANUFACTURER REPRESENTATIVE. 6. ALL HATCHES AND MANHOLE LIDS FOR ACCESS SHALL BE FLUSH WITH ADJACENT GROUND. 7. DURING CONSTRUCTION, STORMWATER RUNOFF SHALL NOT ENTER THE TREATMENT FACILITY UNLESS APPROVED BY THE ENGINEER. al I I C/L 4(U 1 PERIMETER VOID AREA II - VERTICAL Lf L 9:-L L.LL•L. • UNDERDRAIN WETLAND MEDIA BED L;I�LL'LLLL. . LL - �:•.. MANIFOLD I � • I Lhwt LLLLtL'�L' G LL LL-L`LLL'LrL• L L L' LL•L'Lf_L L' LLL Ij L L L 1_ - _ L` .:....1.. •'• L`L �� •1 � 1 ' I L L•LLLL'LL L L L ' . ' I LL LLL'' LLLL" t L� ' LL:L L - IL. L L• LLLL ' �L i� , 1�LL1. `L LkL '; 51.9 4 �L+_LLLL'L L'LLLL LL'•LLL•LL _ L'LLL' LL* ?�`�' _ U o U \ u PRE -FILTER I CARTRIDGE B INLET PIPE, SEE NOTES OUTLET PIPE, 1 ' SEE NOTES PLAN VIEW RIM/FS, SEE TABLE FINISHED GRADE C/L TOP OF VAULT, ;. t . :.r• . ' j.. SEE TABLE \ PEAK HGL, SEE TABLE -x FLOW CONTROL IE IN, RISER - SEE TABLE ° ° ° O O ° ° ° ° ° O O ° ° o O O O O ° ° ° ° ° ° ° ° o ° ° O O O O O ° O O I ° ° " ° ° r ° ° ° ° ° ° O O ° ° '77- IE OUT, 77 :� :. ::t'' j :.71• SEE TABLE �' r ;:; : ,. 12' 13' FRAME AND COVER FINISHED GRADE FRAME AND COVER L i t N n \ tl O O O O t \ j I. O O O y \ 0 O O �� 00 6" 6" FRAME AND COVER a LEFT END VIEW SECTION SCALE: NOT TO SCLAE FINISHED GRADE ELEVATION VIEW RIGHT END VIEW SECTION SECTION SCALE: NOT TO SCALE - MODULAR WETLAND 1-2 SCALE: NOT TO SCLAE DEVELOPMENT ENGINEERING DETAIL Michael Sippo 09/11 /2024 SCALE: NOT TO SCALE 1DRP.03 R-4214217 AD -READY SUBMITTAL DESIGNED: APPROVED: METRO TRANSIT CAPITAL DIVISION DATE: .�� B. �j W. HICKEY G. FRANCO RAPT DRI DE 1 LINE JUNE 2024 7 (425) 453-5000 yy aF W h j �'�- DRAWN: 1100 112TH AVE NE, SUITE 500 �w �, King County A coBELLEVUE, WA 98004 H. JOHNSON La CHECKED: PROJECT NO: R E N TO N SEGMENT DRAWING NO: ° GisTV, J.ETULAIN E00566E18 MET DRAINAGE DETAILS 1 DRD.05 No. REVISION BY APP'D DATE sIONAL S 06112124 CHECKED: CONTRACT NO: 50F8 SHEET NO: OF K.CHANG YUEN CXXXXXXXX 239 473