Loading...
HomeMy WebLinkAboutR-4214231r N 0 0 W Imm WIN N 0 W J boo CC) J w Cl)§E 0 o U ljj o m X 7- C Leo cli CS cal o �I x w 0 o N 0 CDU � o m a) � F- U 0 0 Y 3: w v> 3F-wC7 0-0 w Q U a X TOP OF WALL 3" ABOVE FINISHED GRADE RESTORE SURFACE TO ORIG OR BETTER CONDITION UNDISTURBED SOIL OR COMPACTED NATIVE SOIL OR STRUCT FILL IF NEEDED — 4 - 6 QUARRY SPALLS 4 SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN 3'-0" �O1S 1" MINUS WASHED ROCK �— FILTER FABRIC & DRAIN PIPE FOR WALLS HIGHER THAN T-0" — (2) #5 (4) #5 #4 @ 12" W/ 3" COVER UNDISTURBED SOIL WALL LAYOUT LINE REBAR OVERLAPPING WALL LAYOUT LINE LENGTH 2'-0" REBAR 1'-0" 8" 511PEDESTRIAN 3/4" CHAMFER FOR ALL EXPOSED '_6,1 GUARDRAIL SIDEWALK OR SIDEWALK OVERLAPPING * EXTENSION PER CITY STD DETAIL LENGTH 2 0 10 2 EDGES #4 N F_ @ 12" OC BEYOND THE THICKENED EDGE #4 @ 12" OC EW ALIGNED W/ VERT REINF VARIES SHOWN VARIES • #5 @ 12" EW W/ 3" COVER, SEE - //\\/� TYPICAL CORNER DETAIL ON SHEET N SIDEWALK OR SIDEWALK `9 \ EXTENSION PER CITY STD 1 R2.02 FOR REBARS AT ALL CORNERS J 1 ° \, #4 @ 12" OC 1 \ DETAIL BEYOND THE THICKENED REINF BARS CONT BTWN WALL OR \ - ° �\//\� (5) #4 EDGE SHOWN CURB & FTG OR SIDEWALK, 0 2X4 KEY DOWELLING WALL OR CURB TO FTG Q = Q Q 10" THICK CONC \\/\\ STRUCTURAL FILL /j\\jj\ SHALL NOT BE ACCEPTABLE o = �j w --6�, RETAINING WALL ° \�//\� STRUCTURE FILL \\\ :;:t (D w � - 4" TO 6" QUARRY SPACES w w zo #5 @ 12" OC VERT SEE NOTE Jco= Q DAYLIGHT TO ��//� FILTER FABRIC Q w J > LANDSCAPED AREA ' • VARIES _ 1" MINUS WASHED ROCK ' // // •• :,,: 1" MINUS WASHED ROCK w w #4 @ 8" OC HORIZ : ~�• ;••; 4" Qi PERFORATED PIPE, SEE PLANS VARIES = � :�'- \� 4" 0 PERFORATED PIPE, SEE PLANS J .;• ;rY;;::: /,\i FOR / ,:..�:'—:• Q , FOR DAYLIGHTING REQUIREMENTS / DOWELS // ° / () 5 \/• • • • \�%\\%\\%\\% � > \\\\ \ � \%\\� FILTER FABRIC 2X4 KEY #5 \ \/\\ \/ @ 10" OC � \ (3) #5\�\\/�\\/�\\/�\\/�\\/�\\/�� 4" - 6" QUARRY SPACES \�\/��\/, c:� 1'-3" 1'-6" 6" SIDEWALK OR SIDEWALK 1'-1" * 1'-8" * EXTENSION PER CITY STD DETAIL BEYOND THE THICKENED EDGE *DIMENSION FOR WALL R06R ONLY TO SHOWN ACCOMMODATE 2" MAX ARCH RELIEF \/%/%/%///%/%/%/%//\�/%/%/%/%//\�/%/%/%/% %/%/%/ �// // // // // // r / / THICKNESS.r\r�\r�,�\r\\r\\r\\r\\r\\r�\r�\r\\r\ #6 REBAR @12 OC 5'-011 81, CIP CONC WALL COMBINED RETAINING WALL - SIDEWALK SECTION ('_A� SCALE: NTS 1 R1.02,1 11111.04,111 R1.06 TOP OF WALL 3" ABOVE FINISHED GRADE RESTORE SURFACE TO ORIG OR BETTER CONDITION UNDISTURBED SOIL OR COMPACTED NATIVE SOIL OR STRUCT FILL IF NEEDED — 4 - 6 QUARRY SPALLS 4" SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN J -U 1" MINUS WASHED ROCK r \' FILTER FABRIC & DRAIN PIPE FOR WALLS HIGHER THAN 3'-0" (2) #5 UNDISTURBED SOIL (2) #5 WALL LAYOUT LINE 1'-0" 8" 101, * 3/4" CHAMFER FOR ALL EXPOSED EDGES #5 @ 12" EW W/ 3" COVER, SEE TYPICAL CORNER DETAIL ON SHEET 1 R2.02 FOR REBARS AT ALL CORNERS REINF BARS CONT BTWN WALL OR CURB & FTG OR SIDEWALK, X DOWELLING WALL OR CURB TO FTG < SHALL NOT BE ACCEPTABLE - z 0 0 SEE NOTE w w w = w w J C0 Q C Uj VARIES Of 1'-3" *DIMENSION FOR WALL R06R ONLY TO ACCOMMODATE 2" MAX ARCH RELIEF THICKNESS. 0 N SEE TYPICAL STATION SECTIONS FOR SHELTER OR PYLON FOOTING DETAILS. RE CIP CONC WALL COMBINED RETAINING WALL - 2'-0" SHELTER OR PYLON FOOTING SECTION SCALE: NTS 1 R1.0291 R1.0411 R1.06 CIP CONC WALL COUNTERFORT WALL WITH INTEGRATED SIDEWALK SECTION SCALE: NTS 1 R1.01 5" PEDESTRIAN GUARDRAIL TYPE 1 WALL LAYOUT LINE 10" THICK CONC a, RETAINING WALLLO z #5 @ 12" OC VERT - _0 DAYLIGHT TO w LANDSCAPED AREA C/) J J � G7 LU #5 @ 12" OC R/ j DOWELS 2X4 KEY (3) #5 ,--- WALL LAYOUT LINE 5" — PEDESTRIAN GUARDRAIL TYPE 1 — TOP OF WALL 2'-6" N #4 N @ 12" OC X Q ALIGNED W/ VERT REINF 0 z z0 2"x4" KEY o LU DAYLIGHT TO `\' w LANDSCAPED AREA = Iw EXISTING GROUND J CO (VARIES) w , #5 REBAR @ 12" OC EW (TYP TO SIDEWALLS) 0 2'-0" (8) #6 CIP CONC WALL COMBINED OVER 2'-0" HIGH FILL WALL - SIDEWALK NOTE: SECTION IF WALL/FTG NOT CONSTRUCTED SCALE: NTS 1 R1.03 , MONOLITHICALLY, ROUGHEN TOP SURFACE OF SLAB UNDER WALL CLEAN AND COAT WITH CONC EPDXY BONDING V-8 1/2" SHELTER LEG COMPOUND OR PRODUCE A 1" D X 4" W 6 3/4" CONTINUOUS KEYWAY. SEE SITE PLAN FOR TRIM REINF AROUND SHELTER SEE TYPICAL STATION SECTIONS LOCATION OF CONDUIT SHOE BEARING BLOCKOUT FOR SHELTER OR PYLON SEE KC METRO STANDARD FOOTING DETAILS VARIES DRAWING D101C FOR SHELTER FOOTING DETAILS NOT SHOWN. N #5 @ 12" OC 1 PREMOLDED JOINT FILLER -- \ STRUCTURAL FILL 4" TO 6" QUARRY SPALLS FILTER FABRIC ----�- :: / 1" MINUS WASHED ROCK 4" 0 PERFORATED PIPE, SEE PLANS FOR DAYLIGHTING REQUIREMENTS (6) #5 #5 @ 10" OC CIP CONC WALL 0 COUNTERFORT WALL WITH F50 SHELTER FOOTING SECTION SCALE: NTS 1 R1.01 DESIGNED: APPROVED: AD -READY SUBMITTAL P, M. H. D'ACCI G. FRANCO (425) 453-5000 Q of w�s�1�9� DRAWN: 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 D.ARRANTS CHECKED: PROJECT NO: 57217 AL ��G���w X. WU E00566E18 �'SIQNAL �1J� CHECKED: CONTRACT N0: No. REVISION BY APP'D DATE 06/11/2024 K. CHANG YUEN CXXXXXXXX SIDEWALL STRUCTURAL FILL 1" MINUS WASHED ROCK 4 0 PERFORATED PIPE, SEE PLANS FOR DAYLIGHTING REQUIREMENTS FILTER FABRIC 4" - 6" QUARRY SPALLS — - WALL LAYOUT LINE PEDESTRIAN GUARDRAIL TYPE 1 & SHELTER LEG TOP OF WALL z 0 = Q = w C� w w w = w J Cn J C/) w CIP CONC WALL COMBINED OVER 2'-0" HIGH FILL WALL - SHELTER OR PYLON FOOTING DEVELOPMENT ENGINEERING SECTION (f�� ` SCALE: NTS 1 R1.03 Michael Sippo 09/11 /2024 METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE LQ King County MET RENTON SEGMENT RETAINING WALL DETAILS R-4214231 DATE: JUNE 2024 DRAWING NO: 1 R2.01 SHEET NO: OF 253 473