Loading...
HomeMy WebLinkAboutR-421423241 r N qT 1 O 1 W H N 0 N 7 0 a J o -on C J w co CD oU Uj o m X 7 - (.0 C�� L N o CDo cal o �I w 0 O N 0 0 0 a) o m a� � c � U p Y U) U_ 0-0 w Q 0 a X 3/4" CHAMFER HMA SEE PAVING PLANS FOR DETAILS UNDISTURBED SOIL OR COMPACTED NATIVE SOIL OR STRUCT FILL IF NEEDED 4" - 6" QUARRY SPALLS REINF BARS CONT BTWN WALL & FTG OR SIDEWALK, DOWELLING WALL TO FTG SHALL NOT BE ACCEPTABLE 4" SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN 3'-011 1" MINUS WASHED ROCK WALL LAYOUT LINE 12" PEDESTRIAN GUARDRAIL 1'-6" TALL 2" MAX ARCH RELIEF THICKNESS #5 AT 12" SPA. #4 AT 12" MAX. SPA., TYP. - SEE NOTE 2% X cQ G 0 z O_ _ ~ Q > = w C� w w w = w J cf) J U Q w Q FILTER FABRIC &DRAIN PIPE __J��•`��\\/��\\��\\��\\�� ice\\ice\\ice\\i i�\\/i�\\ice\\\i� �\\r�\ice\\\%r��'�%� S I D EWALK OR SIDEWALK FOR WALLS HIGHER THAN 3-0 EXTENSION PER CITY STD 3'-011 1'-6" 611 DETAIL BEYOND THE THICKENED EDGE SHOWN CIP CONC WALL COMBINED RETAINING WALL AND BARRIER - SIDEWALK SECTION NOTE: SCALE: NTS 1 R1.05 3/4" CHAMFER HMA SEE PAVING PLANS FOR DETAILS UNDISTURBED SOIL OR COMPACTED NATIVE SOIL OR STRUCT FILL IF NEEDED 4" - 6" QUARRY SPALLS - REINF BARS CONT BTWN WALL & FTG, DOWELLING WALL TO FTG SHALL NOT BE ACCEPTABLE 4" SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN 3'-011 z Co � 1" MINUS WASHED ROCK - 0 N 1'-011 WALL LAYOUT LINE 12" PEDESTRIAN GUARDRAIL 1'-6" TALL 2" MAX ARCH RELIEF THICKNESS #5 AT 12" SPA. Q 75 0 #4 AT 12" MAX. SPA., TYP. - SEE NOTE 2% 0 N 2 ~ Q > = w C� w w w = w J c/) J U w PEDESTF RET) PEDESI POLE F, IF WALL/FTG NOT CONSTRUCTED MONOLITHICALLY, ROUGHEN TOP SURFACE OF SLAB UNDER WALL CLEAN AND COAT WITH CONC EPDXY BONDING COMPOUND OR PRODUCE A 1" D X 4" W CONTINUOUS KEYWAY. FILTER FABRIC & DRAIN PIPE 1 11 FOR WALLS HIGHER THAN 3 -0SEE TYPICAL STATION SECTIONS FOR SHELTER OR PYLON FOOTING DETAILS. CIP CONC WALL - COMBINED RETAINING WALL AND BARRIER - 2'-0" SHELTER OR PYLON FOOTING SECTION rB� SCALE: NTS 1 R1.05 AD -READY SUBMITTAL No. I REVISION BY I APP'D I DATE LIGH FOUI SIDEWAI P')r r%r'nT P')I A AI I I/-%1 1T Mf-NI r -MOLDED JOINT FILLER SIDEWALK DNAL TOP & RS ADJACENT ►CKOUT, TYP FILL RETAINING WALL AT LIGHT POLE DETAIL SCALE: NTS ADJACENT TO BLOCKOUT, TYP nrnrSTRIAN DRAIL i VG WALL T FILLER CUT RETAINING WALL AT LIGHT POLE DETAIL SCALE: NTS so co(425) 453-5000 1100 112TH AVE NE, SUITE 500 BELLEVUE, WA 98004 SIDEWALK PREMOLI JOINT FIl BLOCKOUT FOR PEDESTRIAN LI( POLE FOUNDAT ADDITIONAL TO[ BOT BARS ADJAI TO BLOCKOUT, DESIGNED: APPROVED: M. Ij H. D'ACCI G. FRANCO \U 1S�1�9� DRAWN: 1� _ D.ARRANTS CHECKED: PROJECT NO: W � 57217 2AL X. WU E00566E18 NAL E1� CHECKED: CONTRACT NO: 0611112024 K. CHANG YUEN CXXXXXXXX 1/2" PREMOLDED Ir11AIT CL EXPANSION JOINT (`(IAA mim RPTAINIINI(, V1/01 I R. rnhApimm Rr:TAINIINI(, VV01 I R. V L L V V I I Y I 1\ L V LrIL DETAIL, TYP EXPANSION JOINT DETAIL vv I I vlvl vl I I v EXPANSION JOINT ELEVATION SCALE: NTS NOTE: REINFORCING NOT SHOWN. CUT WALL SHOWN, FILL WALL SIMILAR. JOINT ADJACENT TO FOOTING SHOWN, JOINT BETWEEN WALL SECTIONS SIMILAR. SECTION SCALE: NTS LQ King County METRO CL JOINT JOINT REVEAL DETAIL SECTION (C� SCALE: NTS nrinir-ORCING =CTION #5 HORIZ. L 3'-6" X 3'-6" @ 8" O.C. REDUCE SPACING TO 4" O.C. FOR WALLS OVER 12'-0" IN LENGTH VERT. REINFORCING PER WALL SECTION RETAINING WALL TYPICAL CORNER DETAIL SCALE: NTS R-4214232 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: RETAINING WALL DETAILS 1 R2.02 SHEET NO: OF 254 473 N M 0 O O 1 N a