Loading...
HomeMy WebLinkAboutR-4214267qT r N qT 0 0 W LO 0 0 C Cz 0 U-)>' U)a) _ c M co o m M Q M V O 00 N Ow N N Y1 Mo rI X V w N n oCD� oD o m a> _C3 a� a � U o � Y � w cii � L w 0-0 w Q CD U a X 2E RAPIDRIDE SHELTER RR2; FOR TIER 1, SEE SHEET FSI-105-00-004/001; FOR TIER 2, SEE FSI-105-00-006/001 IN RAPIDRIDE 2 KIT OF PARTS DWG PACKAGE LEFT OR RIGHT WINDSCREEN WHERE OCCURS, SEE STATION PLANS SHELTER FOUNDATION, SEE SHEET S2.11 IN RAPIDRIDE 2 KIT OF PARTS STRUCTURAL DWGS CONC PAVING, SEE CIVIL DWGS CURB SEE CIVIL DWGS c� D 10' MIN 1 '-0" BACK ZONE OR SIDEWALK LUSH LANDSCAPE AREA, SEE CIVIL DWGS FOR NON TYPICAL BACK OF STATION CONDITIONS -FINISH GRADE V-5-1/2" PER STRUCTURAL DWGS COLUMN I LINE RAPIDRIDE TYPICAL SHELTER SECTION SECTION SCALE: 3/8" = 1'-0" 1 S5.01 WELD HSS TOP RAIL WITH MITRE JOINT TO HSS END POST SEE STATION PLANS FOR RAILING LENGTH AND LOCATION 1/4" DIA AIR PRESSURE RELEASE HOLE CENTERED UNDERNEATH TOP RAIL; PROVIDE ONE HOLE SPACED 1" ' FROM EDGE OF EACH INTERMEDIARY POST, TYP 411 OC TYP EQ 3 -6 MAX, TYP 0 CONC PAVING, SEE CIVIL DWGS CURB SEE CIVIL DWGS 10' MIN TECH PYLON, SEE SHEET FSI-105-00-003/02 IN TECH PYLON DWG PACKAGE TECH PYLON FOUNDATION, SEE SHEET S3.01 IN RAPIDRIDE 2 KIT OF PARTS STRUCTURAL DWGS LANDSCAPE AREA, SEE CIVIL DWGS FOR NON TYPICAL BACK OF STATION CONDITIONS FLUSH v v • . r .s: �D II— I V-11" PER STRUCTURAL DWGS COLUMN I LINE RAPIDRIDE TYPICAL TECH PYLON SECTION SECTION SCALE: 3/8" = V-0" 1 S5.01 WHERE LENGTHS OF GUARDRAIL NEED TO BE JOINED, WELD ENDS OF TOP RAIL, ABOVE POSTS, AND CENTER JOINT ABOVE CENTERLINE OF INTERMEDIARY POSTS; TOP RAIL TO APPEAR CONTINUOUS HSS 3X2X1/4 TOP HSS3x2x1/4 STEEL RAIL, TYP, WELD TOP RAIL, ASTM TO POSTS 500, GR B. WELD HSS 3X2X1/4 TO POSTS, TYP INTERMEDIARY POST, TYP HSS 1 /2 X 2 ASTM HSS 1/2 X 2 ASTM A36 A36 STEEL PLATE STEEL PLATE INFILL INFILL PICKETS PICKETS, WELD TO TOP X AND BOTTOM RAILS Q HSS 3X2X1/4 HSS3x2x1/4 STEEL BOTTOM RAIL, TYP, BOTTOM RAIL, ASTM WELD TO POSTS • D. .D v v p I I D D I a` vp" •p. v G v I � D v v. HSS END POST NOTES: 1. RAILING - TOP AND BOTTOM RAILS TO MATCH SLOPE OF SITE AT EACH LOCATION; EXPANSION POSTS AND PICKETS TO BE VERTICAL. ANCHOR, TYP 'CE 2. ALL STEEL SHALL BE GALVANIZED. ANY WELDING OR REPAIR IN THE FIELD SHALL BE PAINTED WITH ZINC RICH GALVANIZING REPAIR PAINT CONFORMING TO FEDERAL SPECIFICATION MIL-P-21035B AND IN ACCORDANCE WITH MOST CURRENT WSDOT STANDARD SPECIFICATIONS. 3. SEE DETAIL B/1S6.02 AND C/1S6.02 FOR RAILING PLAN WHERE RAILING IS INSTALLED WITH ANGLED CORNERS PER STATION PLANS. 4. SEE DETAIL A/1S6.02 FOR PEDESTRIAN GUARDRAIL WHEN OCCURS AT SHELTERS. PEDESTRIAN GUARDRAIL DETAIL SCALE: NTS 1 S5.01 AD -READY SUBMITTAL 7 (425) 453-5000 1100 112TH AVE NE, SUITE 500 JacobsBELLEVUE, INA 98004 HBBC No. REVISION BY APP'D DATE LANDSCAPE ARCHITECTURE 500, GR B. WELD TO POSTS, TYP BASE PLATE EXPANSION ANCHOR, TYP c� BASE PLATE; PL 1/2" ASTM A36 1/2" DIA HOLE HSS3X2X1/4 POS WELD POST TO BASE PLATE 9/16" HOLE; 1/2" TYPE 304 SS EXPANSION ANCHOR WITH 4" EMBEDMENT, TYP PEDESTRIAN GUARDRAIL SECTION of WAs,y ��' R O �d11 flb� 171-196EXP_ DETAIL R SCALE: NTS 1 S5.01 DESIGNED: C J. VONG DRAWN: 2 3 J. BAKKE CHECKED: h c� Doti D. KOONTS P CHECKED: K. CHANG YUEN APPROVED: G.FRANCO PROJECT NO: E00566E18 CONTRACT NO: CXXXXXXXX BACK OF ZONE OR SIDEWALK EXPANSION ANCHOR, TYP I BACK OF . . . ... PLATFORM . . . RAILING, ABOVE I RAILING BASE PLATE — — — — — ----------- O ALIGN FACE OF RAILING POST WITH FACE OF COLUMN SHELTER COLUMN ----------- T- ----- O O . . . . . . . . . .. X ... ... ... .. PEDESTRIAN GUARDRAIL DETAIL DETAIL SCALE: NTS 1 S5.01 611 1" 4" 1" O I O z , O I O RAILING BASE PLATE ,,e SHELTER COLUMN BASE PLATE R v ° d NOTES: 1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST WSDOT STANDARD SPECS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION. 2. STRUCTURAL STEEL BASE PLATES SHALL BE IN ACCORDANCE WITH ASTM A36 WITH A MIN YIELD STRENGTH OF 36,000 PSI. 3. ALL WELDING SHALL BE DONE IN ACCORDANCE WITH THE LATEST AWS STANDARDS. 4. USE LOW HYDROGEN E70XX ELECTRODES FOR ALL WELDING. 5. MIN DESIGN BOLT LOAD PER ANCHOR BOLT = 3,250 LBS TENSION. 6. HORIZONTAL SHEAR IS LESS THAN 250 LBS PER BOLT AND MAY BE NEGLECTED. 7. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1701 IS REQUIRED FOR THE SUPPLY AND THE INSTALLATION INSPECTION FOR ALL ANCHOR BOLTS. 8. ALL DRILLED IN PLACE ANCHOR BOLTS SHALL BE PROVIDED BY HILTI OR APPROVED EQUIVALENT. 9. SUBSTITUTIONS SHALL TAKE INTO ACCOUNT DISTANCE BETWEEN BOLTS IN THE BASE PLATE, THEIR EMBEDMENT IN THE CONCRETE AND EDGE DISTANCE TO ATTAIN THIS MIN BOLT LOAD. 10. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE PROJECT REPRESENTATIVE FOR REVIEW PRIOR TO INSTALLATION. 11. SEE DETAIL C/1S5.01 FOR BASE PLATE LOCATION ADJACENT TO SHELTER COLUMN. THICKENED SLAB EDGE OR WALL FOUNDATION - SEE CIVIL PLANS FOR LIMITS AND STRUCTURAL PLANS FOR DETAILS PEDESTRIAN GUARDRAIL ATTACHMENT DETAIL SCALE: NTS 1 S5.01 LQ King County METRO DEVELOPMENT ENGINEERING Michael Sippo 09/11/2024 FR-4214267 METRO TRANSIT CAPITAL DIVISION DATE: RAPIDRIDE I LINE JUNE2024 RENTON SEGMENT DRAWING NO: TYPICAL STATION SECTIONS 1 S5.01 SHEET NO: OF 289 473