Loading...
HomeMy WebLinkAboutTSI #1 RRFB PB Ped Poles Anchor BoltsPE Appr'l Code Date Project Engineer Distribution State Materials Engineer Distrubution Contractor General File Signing Inpsection Region Operations Engineer Other __________________________________ Fabrication Inspection M/S 47365 Revised 03/2018 Region Materials State Materials Lab DOT Form 350-071 10. Approval Withheld: 11. Miscellaneous Acceptance Criteria. Remarks: 5. Acceptance Criteria: Only 'Approved for Shipment' or 'WSDOT Inspected' or 'Fabrication Approved Decal' material shall be used. 6. Acceptance Criteria: Submit Materials Certificate of Origin to Project Engineer. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: ______________________________________________________________________________________ 9. Approval Withheld: Submit samples for preliminary evaluation. Approval Action Codes for use by Project Engineer and state Materials Laboratory 1. Acceptance Criteria: Acceptance based upon 'Satisfactory' Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Submit Mfg. Cert of Compliance for 'Acceptance' prior to use of material 3. Acceptance Criteria: Catalog Cuts for 'Acceptance' prior to use of material. Catalog Cut Approved Yes No 4. Acceptance Criteria: Submit Shop Drawings for 'Approval' prior to fabrication of mateiral. Project Engineer/Representative Date State Materials Engineer Pedestal Base Part No PB-5334-NL-1S-GL-PNC Pelco Edmond OK 9-29 Anchor Bolts Part No AP-1095-GLV Pelco Edmond OK 9-29 1 Pedestal Pole Part # PB-51020-14-PNC Pelco Edmond OK 9-29 Pole Cap Part No PB-5401-PNC Pelco Edmond OK 9-29 1 Sign 24" x 12" (W16-7PL) Carmanah Part # 91315 Carmanah - Victoria, BC, Canada 9-29 1 Sign 12" x 12" (W11-501) Carmanah Part # 91888 Carmanah - Victoria, BC, Canada 9-29 1 Sign 30"x30" (s1-1) Carmanah Part # 91344 Carmanah - Victoria, BC, Canada 9-29 1 Sign 24" x 12" (W16-7PR) Carmanah Part # 91314 Carmanah - Victoria, BC, Canada 9-29 1 Carmanah SC315-G RRFB Part # 84577 Carmanah - Victoria, BC, Canada 9-29 1 Pushutton Staton Part # INX9WN0-Y / Harness Part # 84634 Polara 9-29 This shall be completed prior to submittal. If this form is not complete at time of submittal it may be returned for information that was omitted. For WSDOT Use Only RAM # Bid Item No. Material or Manufacturer's Product/Type Name and Location of Fabricator, Manufacturer or Pit Number Specification Reference Hdqtr. Appr'l Code Hazen High School Pedestrian SignalsContractor Subcontractor Sare Electric Transportation Systems Inc TSI#1 2/18/2026 Section / Title of Project County Request for Approval of Material Contract Number FA Number SR Date Washington State Department of Transportation 1 1 1 Material List 1122 Industry Street, Bldg. B, Everett, WA 98223 Phone (425) 438-1133 | Fax (425)438-1585 Bid Item # QTY Description CARMANAH SC315-G RRFB FOR HAZEN HIGH SCHOOL COMPLETE PLANS & SPECIFICATIONS NOT PROVIDED AT TIME OF BID ANY CHANGE TO BELOW LIST OF MATERIAL WILL REQUIRE A NEW QUOTATION $ 0.00 1 CONTROL CABINET, AC (CARMANAH) 84577, SC315-G, UNFINISHED CARMANAH Part # 84577 $3,059.16 (1) CABINET TO POWER (4) LIGHT BARS & (2) PUSHBUTTONS $ 0.00 4 LIGHTBAR (CARMANAH) 87668, W/CONFIRMATION LIGHTS & UNIVERSAL MOUNTING BRACKET (BLACK) CARMANAH Part # 87668 $3,434.92 300 LIGHTBAR HARNESS (CARMANAH) 78209, SC315-G, 4 CONDUCTOR, PER FT CARMANAH Part # 78209 $ 801.00 2 PUSHBUTTON STATION (POLARA) iNX9WN0-Y MID-BLOCK, 9X12 (R10-25) SIGN, NO BRAILLE, STANDARD (YELLOW) POLARA Part # INX9WN0-Y $1,595.68 150 PUSHBUTTON HARNESS CABLE (CARMANAH) 84634, 8C, 20AWG, G SERIES (XAV2E, iNX, GUARDIAN, NON-MX) PER FT CARMANAH Part # 84634 $ 400.50 4 SIGN, 30" X 30" (S1-1) SCHOOL ZONE WALKING CHILDREN SYMBOL, .08", DG3 FYG (3M 4083) CARMANAH Part # 91344 $ 647.56 2 SIGN, 24" X 12" (W16-7PR) RIGHT DOWN ARROW SYMBOL, .08", DG3 FYG (3M 4083) CARMANAH Part # 91314 $ 126.84 2 SIGN, 24" X 12" (W16-7PL) LEFT DOWN ARROW SYMBOL, .08", DG3 FYG (3M 4083) CARMANAH Part # 91315 $ 126.84 2 SIGN, 12" X 12" (W11-501) "CROSS TRAFFIC MAY NOT STOP USE CAUTION WHEN CROSSING" WORDS, .08", DG3 FYG (3M 4083) CARMANAH Part # 91888 $ 200.28 Material List 1122 Industry Street, Bldg. B, Everett, WA 98223 Phone (425) 438-1133 | Fax (425)438-1585 20 BRACKET, 1-BOLT FLARED LEG (CARMANAH) 92261, STAINLESS W/SS BOLT & WASHER CARMANAH Part # 92261 $ 362.60 2 POLE SPUN ALUMINUM (PELCO PRODUCTS) PB-5102-14-PNC, 4-1/2" SCHEDULE 80, 14' LENGTH (UNFINISHED) PELCO PRODUCTS INC Part # PB-5102-14-PNC $1,900.04 2 POLE CAP ACORN (PELCO PRODUCTS) PB-5401-PNC, 4-1/2" OD, ALUMINUM (UNFINISHED) PELCO PRODUCTS INC Part # PB-5401-PNC $ 58.48 2 PEDESTAL BASE ALUMINUM, SQUARE W/ALUMINUM DOOR (PELCO PRODUCTS) PB-5334-NL-1S-GL-PNC, NO LOGO,1 HB, GL (UNFINISHED) PELCO PRODUCTS INC Part # PB-5334-NL-1S-GL-PNC $ 643.24 2 ANCHOR BOLT CAGE ASSEMBLY (PELCO PRODUCTS) AP-1095-GLV, 13" BC, 3/4" - 10NC X 18", W/HARDWARE, 36" REBAR (GALVANIZED) PELCO PRODUCTS INC Part # AP-1095-GLV $ 640.60 1.844.412.8395 | traffic@carmanah.comcarmanah.com SC315-G Cabinet-Based Rectangular Rapid Flashing Beacon Data Sheet * U.S. Department of Transportation Federal Highways Administration, Publication No. FHWA-HRT-10-043 -“Effects of Yellow Rectangular Rapid-Flashing Beacons on Yielding at Multilane Uncontrolled Crosswalks” Rectangular rapid flashing beacons (RRFBs) improve pedestrian safety by increasing yield rates to 72-96% at crosswalks*: DThe benchmark for RRFBs, the SC315-G meets MUTCD requirements, including IA-21, and is Buy America compliant DAudible pushbutton or passive pedestrian activation DSolar or AC-powered DSolar Power Report™ (SPR) prepared for every location to ensure battery longevity Superior Design and Technology The SC315-G is a cabinet-based system with a separate, high-power solar panel. This design enables the SC315-G to work with audible pushbutton stations, passive activation sensors, and remote monitoring, as well as operate at higher intensities and increased activations in challenging environments. MUTCD interim approval IA-21 flash pattern and multiple configurations enable the SC315-G to handle all crosswalk applications. Easy Installation All components, including the battery or AC power supply, Energy Management System (EMS) and optional audible pushbutton controller are housed in a compact, lockable, purpose-built enclosure. It also incorporates a wire routing and termination system, and all components are wired at the factory for an efficient installation. Advanced User Interface The SC315-G comes with an on-board user interface for quick configuration and status monitoring. It allows for simple in-the-field adjustment of flash pattern, duration, intensity, ambient auto adjust, night dimming, and many more. Settings are automatically sent wirelessly to all units in the system. Reliable Every solar-powered model is solar-sized by location to ensure year-after-year operation. Carmanah includes a Solar Power Report to prove sustainability over a 12-month period. COMPLIA N T MUTCD compliant Buy America compliant Solar-sized for every location 5-year limited warranty SC315-G Cabinet-Based Rectangular Rapid Flashing Beacon Data Sheet 1.844.412.8395 | traffic@carmanah.com | carmanah.com LIGHT BAR CONFIGURATION Uni-directional Configuration Bi-directional Configuration SYSTEM SPECIFICATIONS BEACON SPECIFICATIONS Optical MUTCD interim approval IA-21 and MUTCDC compliant Purpose-built light bar optics = maximum efficiency and no stray lightExceeds SAE J595 class 1 intensity by 2.5 to 3x when used as recommended Meets SAE J578 chromaticity 3 in (76 mm) x 7 in (178 mm) clear, UV-rated polycarbonate lens with yellow LEDs High-power LEDs: +90% lumen maintenance (L90) based on IES LM-80 Side-emitting pedestrian confirmation LEDs Independent, stainless steel mounting brackets make back-to-back installation simple and enable in-field aiming for maximum effectiveness Yellow, black, or green powder coated light bar covers Specifications subject to local environmental conditions, and may be subject to change. All Carmanah products are manufactured in facilities that are certified to ISO quality standards. “Carmanah” and Carmanah logo are trademarks of Carmanah Technologies Corp. © 2022, Carmanah Technologies Corp. Document: Carmanah_DATA_SC315-G_RevC CABINET DIMENSIONS 399 mm15.7" 534 mm21.0" 208 mm8.2" 2.5" 63 mm 603 mm 23.7" ACTIVATION OPTIONS Standard Pushbutton Audible Pushbutton Station Passive Activation Sensor On-Board User Interface (OBUI) Adjustable system settings with auto-scrolling LED display on our latest EMS System test, status, and fault detection: battery, solar, button, beacon, radio, day/night Flash patterns: RFB (WW+S), RFB1 (WW+S legacy), RFB2 (WSDOT), 0.5 sec. alternating (MUTCD), 0.5 sec. unison (MUTCD), 0.5 sec. x3 alternating (MUTCD), 0.1 sec. unison, 0.25 sec. unison, 0.1 sec. x3 quick flashes unison, 0.1 sec. x3 quick flashes alternating, steady on Input: momentary for pushbutton activation, normally open switch, normally closed switch, dusk-to-dawn operation Flash duration: 5 sec. to 1 hr. Intensity setting: 20 to 1400 mA for multiple RRFBs, circular beacons, or LED enhanced signs Nighttime dimming: 10 to 100% of daytime intensity Ambient Auto Adjust: increases intensity during bright daytime Automatic Light Control: reduces intensity if the battery is extremely low Temperature correction: yellow beacons Calendar: internal time clock function Radio settings: enable/disable, selectable channel from 1 to 14 Output: enabled when beacons flashing daytime and nighttime, or nighttime onlyE.g., for relay control of overhead lighting Activation counts and data reporting via OBUI or optional USB connection Beacon Communication Encrypted, wireless radio with 2.4 GHz mesh technology Wireless update of settings from any unit to all systems on the same radio channel User-selectable multiple channels to group different beacons and ensure a robust wireless signal Communicates with all other Gen III radio-enabled systems including our R820-E, -F, and -G circular beacons Instantaneous wireless activation: <150 ms Wireless range: 1000 ft (305 m) Integrated, vandal-resistant antenna Power System Solar or AC-powered AC: 100-240 VAC input, 6-14 AWG Replaceable AC-DC power supply, circuit breaker, terminal block wiring Energy Collection 20, 50, or 80 W high-efficiency photovoltaic solar panel 45 deg tilt for optimal energy collection Maximum Power Point Tracking with Temperature Compensation (MPPT-TC) battery charger for optimal energy collection in all solar and battery conditions Energy Storage 12 V battery system with multiple sizes: 35, 55, 100 Ahr. Replaceable, recyclable, sealed, maintenance-free, best-in-class AGM batteries offer the widest temperature range and longest life Battery design life: +5 yrs. Cabinet Construction Weatherproof, gasketed enclosure with vents for ambient air transfer (NEMA 3R) Lockable, hinged door with #2 lockOptional padlockable latch Corrosion-resistant aluminum with stainless steel hardware Raw aluminum finish or yellow, black, or green powder coated Prewired to minimize installation time High-efficiency optics and EMS = the most compact, lightweight system Environmental -35 to 165° F (-37 to 74° C) system operating temperature -40 to 140° F (-40 to 60° C) battery operating temperature 150 mph (241 kph) wind speed as per AASHTO LTS-6 Activation Pushbutton: ADA-compliant, piezo-driven with visual LED and two-tone audible confirmation Audible pushbutton station: ADA-compliant, piezo-driven with visual LED and customizable voice message confirmation Passive activation: microwave-based sensor detects pedestrian Warranty 5-year limited warranty, 1-year limited on batteries Customize Build an RRFB online * Carmanah will conduct a site assessment and provide an Solar Power Report to determine the correct solar panel and battery size. ** Only available in a Side of Pole configuration. 3.5” - 4.5” Diameter Round Top of Pole Mount Side of Pole Mount SOLAR PANELS AND MOUNTS PANEL LENGTH WIDTH 20 W 18.5” (470 mm)13.6” (345 mm) 50 W 26.3” (668 mm)21.2” (538 mm) 80 W 30.7” (780 mm)26.5” (672 mm) * ** 9.0 12.0 18.3 2.6 14.0 iNX: Mid-Block Crossing Push Button Station The iNX push button station is designed for use at a pedestrian crosswalk with in-pavement or overhead flashing yellow lights. The system consists of a 9”x12” instructional sign, a push button with directional arrow (bidirectional and blank buttons also available) for activating the flashing lights, a voice message, and one yellow LED above the push button that flashes when the street warning lights are flashing. The iNX uses the same rugged housing as Polara’s “iNS” iNavigator. In addition to the push button, the iNX contains a speaker, a 10-watt RMS audio amplifier, a noise monitoring microphone for auto volume control, and LED indication. The iNX operates off of the warning light system control unit via six wire connections (see page 2). The iNX has the same Bluetooth configuration interface as the “iNS” iNavigator, which is used to select audio messages, change settings, and download firmware updates. The Bluetooth can also communicate with other buttons, eliminating the need for separate radios to perform this function. The unit is supplied with mounting hardware and installation instructions. iNX is not compatible with XAVCU controllers. Ordering Options iNX 9 W N 0 - Y - Additional Button Options NA - No Arrow BD - Bi-Directional Arrow Braille N - No braille on faceplate (Standard) B - Braille on faceplate Audio Message Option 0 - Standard Messages 1 - Custom Messages Faceplate MUTCD Compliant W - 9x12 R10-25 (Standard) Size of Front Plate Adapter5 - 5" x 7"9 - 9" x 12" (Standard) Non-MUTCD Compliant W - 5x7 Based on R10-25 O - No Faceplate Button Cover Color Back plate is always black. B - Black G - Green Y - Yellow (Standard) Standard Configuration Shown iNX9WN0-B www.polara.comDimensions are in inches.Doc. iNX-CutSheet Rev. C-25329 05/19/2020 Notes: Designed to comply with applicable sections of referenced standards1. All specifications are subject to change without notice2. All specifications are typical unless otherwise specified3. Function Push button station (PBS) for use on crosswalks with flashing yellow lights. Connects to RRFB to enable triggering of crosswalk lights and can provide a locate tone and a voice message. Voice message can be set to play 1/2/3 times, or for the entire time the lights are flashing. Factory Default Setting is to play 2 times per FHWA. Features Instructional 9”x12” retro-reflective sign with tamper-resistant mounting screws• One yellow LED that flashes when warning lights are flashing• ADA-compliant push button with directional arrow, field adjustable to point left,• right, up, or down 10-watt audio amplifier• Weather resistant speaker• Volume and other settings set using the free Polara service app, connected over• Bluetooth Standard English Message: "Yellow lights are flashing" (Default 2X per FHWA)• Standard Spanish Message: "Las luces amarillas estan relampaqueando"• Electrical Properties Mechanical Properties 6 Wire System Termination View 2-Wire inputs for LIGHTS (+/-)* 2-Wire inputs for BUTTON (+/-)* Power (PWR) Ground (GND) *Note: Both LIGHTS and BUTTON accept either polarity. Operating Specifications Parameter Rating Operating Temp. Range -34°C to +74°C (-30°F to +165°F) Storage Temp. Range -45°C to +85°C (-50°F to +185°F) Operating Force 3.0 lbs max Switch Operating Life Greater than 20 million operations Max. Volume 100 dB @ 1 meter Design Compliance Test Type Compliance Functionality MUTCD 2009-4E Temperature and Humidity NEMA TS2 Mechanical Shock and Vibration NEMA TS2 iNX Enclosure NEMA 250 Type 4X Power Requirements DC In 10-24 VDC Lights In 7-32 VDC Idle Current Draw ~15mA @ 12 VDC(Locate Tone With Default Settings) Peak Current Draw(15 VDC Input Power)~500mA with Voice Message at maximum Physical Enclosure Type Plastic sealed housing, powdercoated cast aluminum cover and backplate Installation 3/4" or smaller banding or 2 tapped 1/4-20 holes on 6" centers; 1/2" or larger hole for wire access Dimensions Width 9" (with 9x12" sign) / 5.1 (without sign) Length 18.2" (with 9x12" sign) / 14" (without sign) Maximum Height 2.6" www.polara.comDimensions are in inches.Doc. iNX-CutSheet Rev. C-25329 05/19/2020 45 ° B C D H FG A A E A B C D E F G H 30 .5 .75 2 20 3 3.75 1.875 36 .625 .875 2.5 24 3.5 4.5 2.25 48 .75 1.25 3.25 32 5 6 3 S1-1 * *actual sign color may not be reflected above SCHOOL N C D L M F K G J H E A B W16-7pL LEFT DIAGONAL ARROW PLAQUE * AAAABAAAAABA N 24 12 .375 .625 4.323 3 30°5.844 3.282 5.884 6.925 .600 1.5 30 18 .5 .75 6.524 4.5 30° 8.766 4.923 8.846 10.407 .920 1.875 C *actual sign color may not be reflected above N C D L M F K G J H E A B * W16-7pR RIGHT DIAGONAL ARROW PLAQUE BBAAAAAAAAAA N 24 12 .375 .625 4.323 3 30° 5.844 3.282 5.884 6.925 .600 1.5 30 18 .5 .75 6.524 4.5 30° 8.766 4.923 8.846 10.407 .920 1.875 C *actual sign color may not be reflected above W16-7pR RIGHT DIAGONAL ARROW PLAQUE CROSS TRAFFICMAY NOT STOPUSE CAUTIONWHEN CROSSING FYG (not shown) 1 Description 3M Diamond Grade DG3 Reflective Sheeting Series 4000 (“Sheeting”) features the most efficient retroreflective prism design currently available from 3M for use on vertical traffic control signs and delineators to return light to drivers under a diverse set of nighttime viewing geometries encountered by the driving public. Sheeting, as manufactured by 3M, meets the stringent retroreflective requirements described in the ASTM D4956 standard for Type XI retroreflective Sheeting. The Sheeting is available in the following colors. Table 1. Product Codes by Color Color Product Code White 4090 Yellow 4091 Red 4092 Blue 4095 Green 4097 Brown 4099 Fluorescent Yellow - FY 4081 Fluorescent Yellow-Green - FYG 4083 Fluorescent Orange - FO 4084 Transportation Safety Division 3M™ Diamond Grade™ DG3 Reflective Sheeting Series 4000 Product Bulletin 4000 January 2020 Replaces Product Bulletin 4000 Dated August 2019 2 3M™ Diamond Grade™ DG3 Reflective Sheeting Series 4000 January 2020 2 Specifications The Sheeting conforms to all current performance requirements of ASTM D4956 for Type XI retroreflective sheeting. Additionally, the Sheeting meets the following specifications. 2.1 Legibility A traffic control and guidance sign (“Sign”) made with the Sheeting used for both Sign background and cut- out copy will remain legible when viewed from a moving vehicle under normal day and night driving conditions by not excessively fading, discoloring, cracking, crazing, peeling, and blistering during the legibility periods in the locations as given in Table 2. Signs must be manufactured, installed, and maintained as recommended in the applicable 3M Information Folders listed in Section 16, and legibility must be assessed after Signs have been cleaned as described in 3M Information Folder 1.11. Legibility Period is measured from the initial Sign fabrication date (“Fabrication Date”), and varies by Sign location as shown in Table 2. 2.2 Gloss The Sheeting has a rating of 50 or higher when tested in accordance with ASTM D523 using a 60º glossmeter. 2.3 Optical Stability The Sheeting, applied to a 3-inch x 6-inch test panel, shall retain a minimum of 85% and a maximum of 115% of its initial coefficient of retroreflection when measured at a 0.2º observation and -4º entrance angle, after being placed in an oven at 71 ± 3 ºC (160 ± 5 ºF) for 24 hours followed by conditioning at standard room temperature for two hours. 2.4 Coefficient of Retroreflection (RA) Table 3 describes the durations and coefficients of retained retroreflection1 for Signs fabricated with the Sheeting for use in the US and Canada. The values presented in Table 3 apply only to Sheeting that has been applied, processed, installed, maintained, and cleaned as recommended in the applicable 3M Information Folders listed in Section 16 of this product bulletin. Table 2. Sheeting Legibility Periods by Sheeting and Geographic Sign Location Sheeting Geographic Location of Sign Legibility Period [from Fabrication Date] 4090, 4091, 4092, 4095, 4097, 4099 US & Canada Up to 12 Years 4081, 4083 Alabama, Arizona, Florida, Georgia, Hawaii, Louisiana, Mississippi, New Mexico, South Carolina, and Texas Up to 7 Years Canada and US other than the above States Up to 10 Years 4084 US & Canada Up to 3 Years 1. Conformance to coefficient of retroreflection requirements shall be determined instrumentally in accordance with ASTM E810 “Test Method for Coefficient of Retroreflection of Retroreflective Sheeting,” and per E810, values obtained at 0º and 90º rotations shall be averaged to determine the RA values referenced in Table 3. Table 3. Minimum Retained coefficient of retroreflectiona (RA, [cd/lx/m2]) for Sheeting over time a. The retained coefficient of retroreflection applies for 7 years after Fabrication Date for the following states: Alabama,Arizona, Florida, Georgia, Hawaii, Louisiana, Mississippi, New Mexico, South Carolina, and Texas. For all other locations the retained coefficient of retroreflection is for 10 years. Sheeting Years from Fabrication Date Minimum Retained Coefficient of Retroreflection [cd/lx/m2] 4090, 4091, 4092, 4095, 4097, 4099 On Fabrication Date ASTM D4956 Type XI Up to 7 Years 80% of ASTM D4956 Type XI 8-12 Years 70% ASTM D4956 Type XI 4081, 4083 On Fabrication Date ASTM D4956 Type XI Up to 7 Years/10 Yearsa 70% of ASTM D4956 Type XI 4084 On Fabrication Date ASTM D4956 Type XI Up to 3 Years 70% of ASTM D4956 Type XI 7 3M™ Diamond Grade™ DG3 Reflective Sheeting Series 4000 January 2020 10 Installation Nylon washers are required when twist style fasteners are used to mount Signs. 11 Cleaning Signs that require cleaning should be flushed with water, then washed with a detergent solution and soft bristle brush or sponge. Avoid pressure that may damage Sign faces. Flush with water following washing. Do not use solvents to clean Signs. 12 Durability The durability of the Sheeting will depend upon substrate selection and preparation, compliance with recommended application procedures, geographic area, exposure conditions, and maintenance. Maximum durability can be expected in applications subject to vertical exposure on stationary objects, when processed and applied to aluminum substrates prepared according to the recommendations provided in 3M Information Folder 1.7. The user must determine the suitability of any nonmetallic Sign backing for its intended use. Sign failures caused by substrate failures or improper surface preparations are not the responsibility of 3M. Application to unprimed, excessively rough or non-weather resistant surfaces, or exposure to severe or unusual conditions can shorten the performance lifetime of Sheeting. Signs that are in mountainous areas and covered by snow for prolonged periods may also have reduced durabilities. Atmospheric conditions in certain geographic areas may result in reduced durability. Periodic Sign inspection and regular Sign replacement are strongly recommended in order to help Sign owners establish their own effective service life expectations. 13 Health and Safety Information Read all health hazard, precautionary, and first aid statements found in the Safety Data Sheets (SDS), Article Information Sheets, and product labels of any materials for important health, safety, and environmental information prior to handling or use. To obtain SDSs and Article Information Sheets for 3M products, go to 3M.com/SDS, contact 3M by mail, or for urgent requests call 1-800-364-3577. 14 Warranty Information 14.1 3M Warranty 3M warrants to the manufacturer of the Sign (“Sign Manufacturer”) that the Sheeting will meet the specifications described in section 2 of this Product Bulletin (“3M Warranty”). 14.2 3M MCS™ Warranty and MCS Warranty for Traffic For warranty on screen-printed or digitally printed Sheeting, or Sheeting imaged using translucent films, please refer to the 3M MCS™ Warranty Bulletin. 14.3 3M Warranty Terms and Conditions o The Sheeting must be stored, processed, applied, and maintained as described in this product bulletin and in accordance with all applicable, written 3M procedures provided in the applicable 3M Information Folders listed in Section 16. o A failure to meet the 3M Warranty must be solely the result of design or manufacturing defect in the 3M Sheeting, and not a result of (a) outside causes, including improper fabrication, handling, packing, storing, shipping, maintenance, or installation; (b) non-vertical applications where the Sign is more than +/- 10° from vertical; (c) use of any material or product not recommended by 3M in this product bulletin, in the 3M Information Folders listed in Section 16, or in applicable 3M Technical Memorandums; (d) use of application equipment not recommended by 3M; (e) failure of Sign substrate; (f) loss of adhesion due to incompatible or improperly prepared substrate; (g) exposure to chemicals, abrasion, or other mechanical damage; (h) snow burial or any other Sign burial; (i) collisions, vandalism, or malicious mischief; or (j) an act of God. Pelco offers aluminum, iron, and plastic bases in various sizes as well as poles in aluminum and steel. Pelco’s cast aluminum square base is FHWA certified and meets or exceeds AASHTO break-away requirements. Plastic replacement doors offer an economical way to deter vandalism. Page T11-1www.pelcoinc.com - sales@pelcoinc.com - 405-340-3434 - fax: 405-340-3435 POLES & B A S E S Pedestal Poles Note: 1. Standard poles are typically sold in 1 foot increments. For other lengths contact sales. 2. See Reference Section page v for available paint colors. 7/21/21 Pedestal Pole, Welded, 4”- 8 NPT w/ 5-1/2” Nipple Length, Steel PB-5219 - - Length Coating GLV=Galvanized P_ _=PaintWelded 4”-8NPT TOE Pedestal Pole, 4”- 8 NPT Sch 40, Galv Steel PB-5200 - - GLV - Length Coating Blank=Galvanized Only P_ _=Paint over Galvanized Pedestal Pole, 4”- 8 NPT Sch 40, Spun Alum w/ Pelican ID PB-5100 - - Length Coating PNC=Process No ColorP_ _=Paint Pedestal Pole, 4”- 8 NPT Sch 80, Spun Alum PB-5102 - - Length Coating PNC=Process No Color P_ _=Paint Pedestal Pole, 4”- 8 NPT Sch 40, Steel PB-5201 - - Length Coating P_ _=Paint 4”-8NPT TOE Pedestal Pole, 4” Sch 40, Spun Alum No Threads PB-5101 - - Length Coating PNC=Process No Color P_ _=Paint No Threads 14 PNC Pelco offers pole and arm caps in various sizes in both aluminum and steel. Caps for 4-1/2” OD posts are available in aluminum and ABS plastic. Page T11-8 www.pelcoinc.com - sales@pelcoinc.com - 405-340-3434 - fax: 405-340-3435 POLES & B A S E S Pole & Arm Caps PB-5403 - Coating PNC=Process No Color P_ _=Paint Pole Cap, Acorn Type, Alum, 3” OD Pole PB-5407 - Coating PNC=Process No ColorP_ _=Paint Pole Cap, Acorn Type, Alum, 3-1/2” OD Pole PB-5401 - Coating PNC=Process No Color P_ _=Paint Pole Cap, Acorn Type, Alum, 4-1/2” OD Pole PB-5402 - Coating PNC=Process No ColorP_ _=Paint Pole Cap, Dome Type, Alum, 4-1/2” OD Pole Note: 1. All assemblies are supplied standard with stainless fasteners. 2. See Reference Section for available paint colors. 10/11/17 Pelco offers aluminum, iron, and plastic bases in various sizes as well as poles in aluminum and steel. Pelco’s PB-5334 and PB-5335 cast aluminum square bases are FHWA certified and meets or exceeds AASHTO break-away requirements. Plastic replacement doors offer an economical way to deter vandalism. Page T11-3www.pelcoinc.com - sales@pelcoinc.com - 405-340-3434 - fax: 405-340-3435 POLES & B A S E S 7/21/21 Square Pedestal Bases Aluminum Note: 1. PB-5334 and PB-5335 aluminum square bases above are available with AASHTO certifications and FHWA approval. 2. All assemblies are supplied standard with stainless fasteners. 3. See Reference Section page v for available paint colors. Square Base Assembly, Alum -12k Capacity w/ Alum Door PB-5334 - - - - Set Screws in Collar 1S=1 Hex Bolt 3S=3 Set Screws Blank=None Grounding Lug GL=Ground Lug Blank=None Coating PNC=Process No Color P_ _=Paint Door NL=No Logo Blank=Pelco Logo Square Base Assembly, Alum -12k Capacity w/ Plastic Door PB-5335 - - - - PNC Set Screws in Collar 1S=1 Hex Bolt 3S=3 Set ScrewsBlank=None GroundingLug GL=Ground Lug Blank=None Door NL=No LogoBlank=Pelco Logo 15”13.75”12.0” Min BC 14.5” Max BC Grounding Lug CollarSet Screws PNCGLNL1S Typical Footing Detail QTYDESCRIPTIONPART NUMBERITEM 1Weldment, Anchor Bolt Cage, w/ 3/4"-10 Bolts x 18", 36" Rebar, 13" BC, Steel, Galv AP-1095-1-GLV1 1Hardware Kit, Anchor Bolt Cage, 3/4"-10NC w/ Square Washers, Steel, GalvPB-5422-GLV2 OF TITLE:REF: PH: 405-340-3434 FAX: 405-340-3435Edmond, OK 73013www.pelcoinc.com PART NO.: ASSEMBLY SHEET 1 1 10/19/2000 Anchor Bolt Cage, 13" Bolt Circle, 3/4"-10 x 18", 36" Rebar, w/ Hardware, Galv AP-1095-GLV HDRAWN:DATE:CHECKED:DATE:REV:REV CHK'D: J ROGERS JDC 6/10/2015 DATE: TC 10/29/2009 This drawing is for reference only. It is the property of Pelco and is not to be used in whole or in part without Pelco's written permission. SHEET06/09/15 SRDDATE:DATE:MFG ENG:ZSMQA: 4/9/2014 DATE: JLH 4/9/2014 Pe l c o V e r t i c a l . i d w 3 / 1 6 / 1 5 2 1 16 34 312 Conduit (if Req'd) Note: 1. Anchor Bolt Cages Are Galvanized Above Grade. 2.Used On Square & Octagonal Bases. 9316 93 16 13 Bolt Circle Conduit, Concrete & Additional Rebar, if Needed Provided by Others