Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TSI #5 Wire
PE Appr'l Code Date Project Engineer Distribution State Materials Engineer Distrubution Contractor General File Signing Inpsection Region Operations Engineer Other __________________________________ Fabrication Inspection M/S 47365 Revised 03/2018 TSI #5 Request for Approval of Material Contract Number FA Number SR Date Hazen High School Pedestrian SignalsContractor Subcontractor Sare Electric Transportation Systems Inc TSI #5 2/18/2026 Section / Title of Project County This shall be completed prior to submittal. If this form is not complete at time of submittal it may be returned for information that was omitted. For WSDOT Use Only RAM # Bid Item No. Material or Manufacturer's Product/Type Name and Location of Fabricator, Manufacturer or Pit Number Specification Reference Hdqtr. Appr'l Code 1 14 Awg 2 Conductor Loop Lead In Advanced Digital Cable - Thompsons Station, TN 9-29.3(2)A1 1 Grounding Wire Advanced Digital Cable -Thompsons Station, TN 9-29.3(2)A1 1 18 Awg 4 Conductor Signal Cable Belden - Fort Mill, SC 9-29.3(2)A1 1 Current Carrying Single Conductor 9-29.3(2)A1 Project Engineer/Representative Date State Materials Engineer 5. Acceptance Criteria: Only 'Approved for Shipment' or 'WSDOT Inspected' or 'Fabrication Approved Decal' material shall be used. 6. Acceptance Criteria: Submit Materials Certificate of Origin to Project Engineer. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: ______________________________________________________________________________________ 9. Approval Withheld: Submit samples for preliminary evaluation. Approval Action Codes for use by Project Engineer and state Materials Laboratory 1. Acceptance Criteria: Acceptance based upon 'Satisfactory' Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Submit Mfg. Cert of Compliance for 'Acceptance' prior to use of material 3. Acceptance Criteria: Catalog Cuts for 'Acceptance' prior to use of material. Catalog Cut Approved Yes No 4. Acceptance Criteria: Submit Shop Drawings for 'Approval' prior to fabrication of mateiral. Region Materials State Materials Lab DOT Form 350-071 10. Approval Withheld: 11. Miscellaneous Acceptance Criteria. Remarks: Washington State Department of Transportation Advanced Digital Cable - Thompson Station, TN IMSA Specification 50-2 Loop Lead-In Cable· "replace YYYY with year of manufacture ADVANCED DIGITAL CAllU INC. Specifications Color Code Put-Ups Conductor -Stranded linned Copper per �TM B-8, B-33 Insulation -18 AWG -.030' PE 16 AWG -.030" PE 14AWG-.030" PE 12 AWG-.030' PE Shleldlng -Aluminum Jackel -Polyethylene Voltage Rating -600 V Temp. Rating -75,C Clear/Black (1 Palr Types) See Color Code Tables on Page 15 for MLiH-Palr Cables Standard Reels 1,000', 2,500', 5,000' PART NO. AWG NO.OF PAIRS OIJml JKT NOMINAL WEIGHT ___ nn_c ... KN_E_ss __ -+-___ o. .... o. ___ -t lbs./ 1M' Phone: (800) 343 2579 • Fax: (828) 389 3922 • www.adcable.com 2 XLP USE-2 OR RHH/RHW-2 - BUILDING WIRE Cross-Linked Polyethylene Insulated 14 AWG - 750 MCM • 600/1000 Volts • 90°C Dry and Wet The information contained on this specification is intended to be used a guide in product selection and is believed to be reliable. ADC has made every effort to ensure the data shown above is accurate at the time of publication. This specification is subject to change anytime without notice. Rev IC0221 PHONE: (800) 343 2579 • FAX: (828) 389 3922 • WWW.ADCABLE.COM BU I L D I N G W I R E 42 “ADVANCED DIGITAL CABLE, INC. XX AWG XLP 90C (-40C) E197262 (UL) TYPE RHH OR RHW-2 GRII SR OR USE-2 OIL RES II DIR BUR 600V c(UL) RW90 1KV---RoHS” DESCRIPTION APPLICATIONS CONSTRUCTION INDUSTRY LISTINGS & STANDARDS ADC’s USE-2 is insulated with chemically cross-linked polyethylene insulation. Appropriate for use in general purpose wiring for lighting and power in residential, commercial, and industrial buildings. Suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less. Conductors: Annealed stranded bare copper per ASTM B3. Class B Stranding per ASTM B 8. Insulation: Chemically cross-linked polyethylene Colors: Black, Green, White, Red. Consult factory for other colors UL Listed as XLP USE-2 or RHH/RHW-2 per Standard 44 and 854 ICEA S-95-658/NEMA WC-70 Federal spec A-A-59544 90°C Wet/Dry -40°C Rated Gasoline and Oil Resistant II -GRII C(UL) RW90 1000V Listed Sunlight Resistant -SR Direct Burial RoHS Compliant CT Rated and/or VW-1 Rated available upon request XLPE Insulation Bare Copper Cable Data Part Number AWG Strand Insulation Thickness(mils)Nominal O.D.(inch)ApproximateNet Weight lbs/1M’Copper Weight per lbs/1M’ 314 14 7 45 .161 22 12.69 312 12 7 45 .181 30 20.16 310 10 7 45 .204 45 32.05 308 8 7 60 .264 73 51.00 306 6 7 60 .301 107 81.00 304 4 7 60 .349 161 128.90 303 3 7 60 .377 189 162.50 302 2 7 60 .409 244 204.90 301 1 19 80 .489 305 258.00 3010 1/0 19 80 .522 372 326.00 3020 2/0 19 80 .566 460 411.00 3030 3/0 19 80 .616 568 518.00 3040 4/0 19 80 .672 713 653.00 30250 250 MCM 37 95 .748 853 772.00 30300 300 MCM 37 95 .795 1017 926.00 30350 350 MCM 37 95 .851 1167 1081.00 30400 400 MCM 37 95 .896 1333 1235.00 30500 500 MCM 37 95 .979 1638 1544.00 30600 600 MCM 61 110 1.086 1823 1853.00 30750 750 MCM 61 110 1.188 2476 2309.00 CABLE IDENTIFICATION BID ITEM # SPEC # 9-29.3(2)A1 For more Information please call 1-800-Belden1 General Description: 18 AWG multi-conductor stranded (7x26) bare copper conductors, PVC/Nylon insulation, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 18 7x26 BC - Bare Copper Total Number of Conductors:4 Insulation Insulation Material: Insulation Material PVC/Nylon - Polyvinyl Chloride/Nylon Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 1.194 Outer Jacket Ripcord:Yes Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 Red 3 Blue 4 Orange Overall Nominal Diameter:7.950 mm Mechanical Characteristics (Overall) Wet Temperature Range:-30°C To +75°C Dry Temperature Range:-30°C To +90°C Bulk Cable Weight:77.386 Kg/Km Max. Recommended Pulling Tension:391.442 N Min. Bend Radius/Minor Axis:81.280 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification:NPLF, TC EU Directive 2011/65/EU (ROHS II):Yes EU Directive 2000/53/EC (ELV):Yes EU Directive 2002/95/EC (RoHS):Yes EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005 EU Directive 2002/96/EC (WEEE):Yes EU Directive 2003/11/EC (BFR):Yes CA Prop 65 (CJ for Wire & Cable):Yes MII Order #39 (China RoHS):Yes Page 1 of 2 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 27326A Multi-Conductor - 600V Type TC Cable Other Specification:ICEA S-73-532, S-61-402 Flame Test UL Flame Test:UL1685 FT4 Loading C(UL) Flame Test:FT4 IEEE Flame Test:1202 Suitability Suitability - Indoor:Yes Suitability - Outdoor:Yes Suitability - Burial:Yes Sunlight Resistance:Yes Plenum/Non-Plenum Plenum (Y/N):No Electrical Characteristics (Overall) Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 19.227 Max. Operating Voltage - UL: Voltage 600 V RMS (NEC Type TC) 150 V RMS (NPLF) Max. Recommended Current: Current 4.8 Amps per conductor @ 25°C Put Ups and Colors: Item #Putup Ship Weight Color Notes Item Desc 27326A 01010000 10,000 FT 600.000 LB BLACK C 4 #18 PVC/NYL PVC 27326A 0105000 5,000 FT 290.000 LB BLACK C 4 #18 PVC/NYL PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 07-11-2013 © 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Page 2 of 2 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 27326A Multi-Conductor - 600V Type TC Cable XLP USE-2 or RHH/RHW-2 &DOV POWER CABLE --Bare Copper / XLPE Insulation Cable Identification "ADVANCED DIGITAL CABLE, INC. XX AWG XLP 90C (-40C) E197262 (UL) TYPE RHH OR RHW-2 GRII SR OR USE-2 OIL RES II SUN RES DIR BUR 600V c(UL) HW90 1 KV RoHS" Part Number AWG Strand 314 14 7 312 12 7 310 10 7 308 8 7 306 6 7 304 4 7 303 3 7 302 2 7 301 1 19 3010 1/0 19 3020 2/0 19 3030 3/0 19 3040 4/0 19 30250 250 MCM 37 30300 300 MCM 37 30350 350 MCM 37 30400 400 MCM 37 30500 500 MCM 37 30600 600 MCM 61 30750 750 MCM 61 Cross-Linked Polyethylene Insulated 14-750 MCM • 600 Volts • 90°C Dry and Wet Description Single conductor, 90C Wet/Dry. Insulated with chemically cross-linked polyethylene insulation. Applications Appropriate for use in general purpose wiring for lighting and power -residential, commercial, and industrial buildings. Suitable for applica tions that require superior flame retardance. Construction Conductors: 14AWG -750 MCM fully annealed stranded bare copper per ASTM 83. Class B Stranding per ASTM B 8. Insulation: Chemically cross-linked polyethylene Colors: Black, Brown, Orange, Yellow, Green, White, Red, Gray, Blue. Industry Listings & Standards UL Listed as XLP USE-2 or RHH/RHW-2 per Standard 44 and 854 ICEA S-95-658/NEMA we-70 Federal Specification A-A-59544 90°C Wet/Dry -40°C Rated Gasoline and Oil Resistant 11 C{UL)US RW90 1 OOOV Listed Sunlight Resistant Direct Burial RoHS Compliant @ c@ �,-� LISTED LISTED � Cable Data Insulation Nominal O.D. Approximate Copper Weight Thickness Net Weight lbs. (mils) (inch} /1M' per lbs. / 1 M' 45 .161 22 12.69 45 .181 30 20.16 45 .204 45 32.05 60 .264 73 51.00 60 .301 107 81.00 60 .349 161 128.90 60 .377 189 162.50 60 .409 244 204.90 80 .489 305 258.00 80 .522 372 326.00 80 .566 460 411.00 80 .616 568 518.00 80 .672 713 653.00 95 .748 853 772.00 95 .795 1017 926.00 95 .851 1167 1081.00 95 .896 1333 1235.00 95 .979 1638 1544.00 110 1.086 1823 185300 110 1.188 2476 2309.00 The infonnation contained on this specification is intended to be used as a guide in product selection and is believed to be reliable. OADC AOC has made every effort to ensure the data shown above is accurate at the time of publication. This specification is subject to change anytime wittiout notice. Phone: (800} 343 2579 • Fax: (828} 389 3922 • www.adcable.com AOVAt,KED DIGITAL CASI.I: INC.