Loading...
HomeMy WebLinkAboutVolume II - Bid Manual (Plans) - CAG-26-069General Bid Informa on: Builders Exchange of Washington, Inc. (425) 258-1303 City Contact: Casey Jeszeck (425) 430-7323 cjeszeck@rentonwa.gov Award Amount: _____________________ Award Date: _____________________ Award To: _____________________ _____________________ _____________________ Contract No.: 26-069 Rainier Ave South Stormwater Pump Sta on Upgrade Project Contract Documents Project No.: SWP-27-3963 Public Works Department U lity Systems Division Approved for Bid ____________________________ ___________ City of Renton Date: Renton City Hall—5th Floor 1055 South Grady Way Renton, Washington 98057 Approved for Construc on ____________________________ ___________ City of Renton Date: Volume 2 of 2 Surface Water Enginering jfarah 04/02/2026 PARCEL ID: 723756-0000495 RENTON CENTER WAY SW CALL 48 HOURS BEFORE YOU DIG ONE CALL 1-800-424-5555 REPORT ALL SPILLS DEPT. OF ECOLOGY 1-800-258-5990 CONTACT INFORMATION CONTACT COMPANY POSITION PHONE RH2 ENGINEERING CONSULTANT (206) 498-7471 RH2 ENGINEERING (425) 951-5332CONSULTANT PROJECT LOCATION MAP PROJECT LOCATION S 4TH P L BNSF R R R A I N I E R A V E S PROJECT VICINITY MAP PROJECT LOCATION CASEY JESZECK EDWIN HALIM MAX FREIMUND CITY OF RENTON PROJECT MANAGER (425) 430-7323 I-405 SW GRADY W A Y RA I N E R A V E S S 7TH ST SHEET INDEX SHEET NO.DESCRIPTION DWG NO. RAINER AVE STORMWATER PUMP STATION UPGRADES PROJECT NO. SWP-27-3963 CITY OF RENTON ISSU E D F O R B I D D I N G JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - G 0 1 . D W G SHOWN G01 1 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: GE N E R A L N O T E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F EXISTING LEGEND DRAWING NUMBERS HAVE BEEN ASSIGNED TO EACH DRAWING. DRAWING NUMBERS INCLUDE INFORMATION THAT TELLS THE READER WHAT DISCIPLINE THE DRAWING REFERS TO AND WHICH AREA THE DRAWINGS IS WITHIN. THE FORMAT OF THE DRAWING NUMBER IS AS FOLLOWS: DXXX, WHERE D DISCIPLINE CODE (G, C, A, S, M, E) XXX NUMBER G: GENERAL C: CIVIL S: STRUCTURAL M: MECHANICAL E: ELECTRICAL X X · · · · PLAN DRAWINGS GENERAL SYMBOLOGY PLAN SET ORGANIZATION DRAWING NUMBER DRAWING TYPE, SEE KEY THIS SHEET SECTION AND DETAIL REFERENCES THE FOLLOWING CONVENTIONS HAVE BEEN USED WITHIN THESE DRAWINGS TO REFER THE READER BETWEEN THE SECTION/DETAIL AND THE PLAN FROM WHICH IT IS REFERENCED. REFERENCE BUBBLES: SECTION/DETAIL REFERENCE NUMBER CONVENTIONS: ·SECTIONS OR ELEVATIONS SHOULD HAVE A LETTER REFERENCE NUMBER (A THROUGH ZZ). ·DETAILS SHOULD HAVE AN ALPHANUMERIC REFERENCE NUMBER (A-Z OR 1-1799). SUBSURFACE UTILITY LEGEND GENERAL CONSTRUCTION NOTES G02 EXISTING LEGEND DRAWING NUMBERS HAVE BEEN ASSIGNED TO EACH DRAWING. DRAWING NUMBERS INCLUDE INFORMATION THAT TELLS THE READER WHAT DISCIPLINE THE DRAWING REFERS TO AND WHICH AREA THE DRAWINGS IS WITHIN. THE FORMAT OF THE DRAWING NUMBER IS AS FOLLOWS: DXXX, WHERE D DISCIPLINE CODE (G, C, A, S, M, E) XXX NUMBER G: GENERAL C: CIVIL S: STRUCTURAL M: MECHANICAL E: ELECTRICAL X X · · · · PLAN DRAWINGS GENERAL SYMBOLOGY PROPOSED LEGEND ADDRESSES CRITERIA GEOTECHNICAL NOTES GENERAL CONSTRUCTION GENERAL NOTES TESC GENERAL NOTES EXISTING UTILITIES TRAFFIC CONTROL SURVEY PLAN SET ORGANIZATION DRAWING NUMBER DRAWING TYPE, SEE KEY THIS SHEET SECTION AND DETAIL REFERENCES THE FOLLOWING CONVENTIONS HAVE BEEN USED WITHIN THESE DRAWINGS TO REFER THE READER BETWEEN THE SECTION/DETAIL AND THE PLAN FROM WHICH IT IS REFERENCED. REFERENCE BUBBLES: SECTION/DETAIL REFERENCE NUMBER CONVENTIONS: ·SECTIONS OR ELEVATIONS SHOULD HAVE A LETTER REFERENCE NUMBER (A THROUGH ZZ). ·DETAILS SHOULD HAVE AN ALPHANUMERIC REFERENCE NUMBER (A-Z OR 1-1799). SUBSURFACE UTILITY LEGEND GENERAL CONSTRUCTION NOTES G02 UTILITY CONTACT INFORMATION CONTACT COMPANY POSITION PHONE DAN HEIN DAVID BRINKMAN PSE - ELECTRICAL PSE - GAS SENIOR PROJECT MANAGER PROJECT MANAGER (206) 418-9895 (253) 234-6445 EXISTING STORM SEWER RAINIER AVE S EX I S T I N G S I T E , T E S C , A N D S T A G I N G PL A N JD MR J F Ja n 2 2 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - C 0 1 . D W G SHOWN C01 2 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F EXISTING SITE, TESC, AND STAGING PLANSTORM DRAIN SILT SCREEN DETAIL EXPANSION RESTRAINT (1 4" NYLON ROPE, 2" FLAT WASHERS) DUMP STRAP SILT SACK 1" REBAR FOR BAG REMOVAL FROM INLET, TYPICAL BOTH SIDES DUMP STRAP INLET OR CATCH BASIN POSSIBLE STAGING AREA CATCH BASIN SILT SCREEN, SEE DETAIL THIS SHEET, TYP. EXISTING RETAINING WALL TO BE REMOVED EXISTING FENCE TO BE REMOVED 1.STAGING AREA IDENTIFIED ON THE PLANS SHALL BE USED AT THE CONTRACTOR'S OWN RISK. THE PUMP STATION AND STAGING AREA ARE LOCATED AT LOW POINT ON RAINIER AVE AND MAY FLOOD DURING SEVERE, SHORT DURATION RAIN EVENTS 2.CONTRACTOR RESPONSIBLE FOR SECURING ADDITIONAL STAGING AREA AS NECESSARY TO COMPLETE PROPOSED IMPROVEMENTS. 3.CONTRACTOR RESPONSIBLE FOR PROPOSING A STAGING PLAN FOR THE CITY'S APPROVAL PRIOR TO MOBILIZATION. 4.ANY FLAMMABLE MATERIALS SHALL NOT BE STORED WITHIN BNSF ROW. STAGING NOTES EXISTING 6" PERF. UNDERDRAIN TO BE REMOVED EXERCISE CAUTION AROUND BRIDGE TO AVOID DAMAGING BNSF BRIDGE. BOTTOM OF BRIDGE ELEVATION: 38.6' VERTICAL CLEARANCE: 18.78' [CONSTRUCTION LIMITS] 00 0 65 0 000 400 400 000 RAINIER AVE S JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 3 . D W G SHOWN C02 3 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D S I T E P L A N CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PROPOSED SITE PLAN 3 3 2 2 11 PROPOSED 60-kW NATURAL GAS EMERGENCY GENERATOR PROPOSED RETAINING WALL PROPOSED PEDESTAL FOR NEW AND EXISTING POWER AND TELEMETRY PANELS ABANDON EXISTING ACCESS DOOR ON NORTHEAST EDGE OF BUILDING PER DWG NO. S03. EXISTING SIDEWALK TO BE REPLACED TO THE NEAREST JOINT PER DETAIL COR STD F.102 CONNECT TO THE EXISTING DRAIN PIPE, APPX. IE: 17.70 4" DI (W). CONTRACTOR TO VERIFY EXISTING LOCATION AND INFORM ENGINEER OF ANY DISCREPANCY PROPOSED 6" PERFORATED DRAIN PIPE. EXISTING FIRE HYDRANT, PROTECT IN PLACE. MAINTAIN FIRE DEPARTMENT ACCESS AT ALL TIMES RELOCATE BUILDING ACCESS CONNECT TO THE EXISTING DRAIN PIPE. PROPOSED GAS METER LOCATION PROPOSED GAS LINE ASPHALT TRENCH PATCH PER COR STD DETAIL F. 110 CURB AND GUTTER REPLACEMENT PER COR STD DETAIL F.103 [CONSTRUCTION LIMITS] NOTE: IF THE PUMP REPLACEMENT WORK WILL NOT BE DELIVERED IN A PERIOD OF PROJECTED DRY WEATHER, THE CONTRACTOR SHALL ENSURE CONTINUOUS PUMPING OPERATIONS DURING WET WEATHER WORK BY KEEPING ONE PUMP IN OPERATION OR PROVIDING TEMPORARY PUMPING EQUIVALENT IN CAPACITY TO THE EXISTING PUMPS. COSTS ASSOCIATED WITH TEMPORARY PUMPING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCIDENTAL TO "MECHANICAL" (BID ITEM 16) RAINIE R A V E S RAINIE R A V E S JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - G A S P . D W G SHOWN C03 4 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D G A S M A I N A N D D E T A I L S 4" SAND BEDDING 12" TYPICAL WIDTH 24" DEPTH COVER NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. TYPICAL GAS TRENCH DETAIL 6" SAND SHADING PROPOSED GAS MAIN AND DETAILS CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F 1.THIS SHEET SHOWS THE GAS MAIN EXTENSION WORK NEEDED TO SERVICE THE GAS GENERATOR INSTALLED AT THE PUMP STATION. WORK DESIGNATED AS "BY PSE" SHALL BE COMPLETED BY PUGET SOUND ENERGY, AND IT INCLUDES BUT IS NOT LIMITED TO TRENCHING, DIRECT BORING, BACKFILLING AND GAS LINE INSTALLATION. 2.ALL OTHER WORK ON THIS SHEET NOT DESIGNATED BY "BY PSE" SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. GAS MAIN EXTENSION GENERAL NOTESFINISH SURFACE PER COR STANDARD PLAN 110 GAS CONDUIT AND SIZE VARY AS PER SITE PLAN. SAND BEDDING MATERIAL PER WSDOT SPECIFICATION 9-03.13 NATIVE MATERIAL COMPACTED TO 95% PER ASTM D1557 OR AS REQUIRED PER PLAN RAINIER PUMP STATION APPROXIMATE LOCATION FOR CONNECTION TO EXISTING GAS MAIN GAS MAIN DIRECTIONALLY DRILLED BY PSE ASPHALT TRENCH PATCH, PER COR STANDARD PLAN 110, TYP. CEMENT CONCRETE CURB AND GUTTER RESTORATION, PER COR STANDARD PLAN 103, TYP. CEMENT CONCRETE SIDEWALK RESTORATION, PER COR STANDARD PLAN 102, TYP. CONTRACTOR TO PROVIDE TRENCHING, BACKFILL, AND RESTORATION WORK ASSOCIATED WITH GAS MAIN INSTALLATION. GAS INSTALLATION ITSELF SHALL BE COMPLETED BY PSE. CONTRACTOR TO COORDINATE WITH PSE TO MINIMIZE SCHEDULE IMPACT. NOTE: THE TRENCH PATCHES SHOWN TAKE INTO CONSIDERATION THE APPROXIMATE SIZE OF THE LAUNCHING AND RECEIVING PITS FOR THE DIRECTIONAL DRILLING APPROX. DIMENSIONS FOR PSE GAS INSTALLATION, TYP. RAINIE R A V E S RAINIE R A V E S RAINIE R A V E S JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - T C . D W G SHOWN C04 5 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: TR A F F I C C O N T R O L P L A N A N D D E T A I L S GENERAL NOTES: 1. CONSTRUCTION LIMITS SHALL COINCIDE WITH THE ROW UNLESS NOTED OTHERWISE. TRAFFIC CONTROL NOTES: 1. ANY WORK INVOLVING CLOSING OF A LANE SHALL OCCUR AT NIGHT WITH WRITTEN APPROVAL FROM THE CITY. TRAFFIC CONTROL PLAN AND DETAILS CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F SINGLE LINE CLOSURE PER TC3, FOR WORK AT THE PUMP STATION AND GENERATOR LOCATION DOUBLE LANE CLOSURE PER TC4, FOR GAS CONNECTIONS IN CENTER LINE PROPOSED GENERATOR SECTION 10' 20' 30' 40' 10' 20' 30' 40' 0+00 0+40 EXISTING SECTION 10' 20' 30' 40' 10' 20' 30' 40' 0+00 0+40 PROPOSED ELECTRICAL EQUIPMENT SECTION 10' 20' 30' 40' 10' 20' 30' 40' 0+00 0+40 PROPOSED GENERATOR ELEVATION 10' 20' 30' 40' 10' 20' 30' 40' 0+00 0+65 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D S I T E S E C T I O N S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F 1 2 2 3 EXISTING SIDEWALK GRADE PROPOSED 60-kW NATURAL GAS EMERGENCY GENERATOR PROPOSED ELECTRICAL EQUIPMENT EXISTING GRADE EXISTING GRADE PROPOSED RETAINING WALL PROPOSED ELECTRICAL EQUIPMENT PROPOSED 60-kW NATURAL GAS EMERGENCY GENERATOR EXISTING GRADE PROPOSED RETAINING WALL CONCRETE FILL EXISTING WET WELL PROPOSED FENCE EDGE OF ROW EXISTING RETAINING WALL, TO BE REMOVED SIDEWALK TO BE REPLACED JOINT UTILITY TRENCH EDGE OF ROW EXISTING FENCE, TO BE REMOVED EXISTING RETAINING WALL TO BE REMOVED SIDEWALK EXISTING RETAINING WALL, TO BE REMOVED SIDEWALK TO BE REPLACED EDGE OF ROW PROPOSED FENCE 1 1 CONCRETE FILL PROPOSED GAS LINE FOR GENERATOR JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 3 . D W G SHOWN C05 6 24 PROPOSED CONCRETE STAIRS GRAVEL BACKFILL GRAVEL BACKFILL 6' LONG GEOGRID BEHIND WALL, INSTALLED AT 0.67'. 2', 3.33', AND 4.66' BEHIND 6' TALL WALL (PER WALL AS-BUILTS), TO BE REMOVED EXISTING 6" PERFORATED DRAIN PIPE PERFORATED 6" CPE PIPE PERFORATED 6" CPE PIPE EXISTING PUMP STATION EXISTING GRADE BEHIND PROPOSED RETAINING WALL PROPOSED RETAINING WALL PROPOSED GAS METER EXISTING RETAINING WALL TO BE REMOVED. FORM LINER SHALL BE USED ON EXTERIOR FACE OF CONCRETE FILL TO MATCH EXISTING RETAINING WALL APPEARANCE PROPOSED CONCRETE FILL PROPOSED CONCRETE RETAINING WALL TONGUE JOINT UTILITY TRENCH JOINT UTILITY TRENCH RAINIER AVE S DM F MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 1 . D W G SHOWN S01 7 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D R E T A I N I N G W A L L P L A N CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PROPOSED PEDESTAL FOR NEW AND EXISTING POWER AND TELEMETRY PANELS PER DWG NO. E09 EXISTING RETAINING WALL (TO REMAIN) PROPOSED 4' CONCRETE WALK FROM STREET SIDEWALK TO NEW ACCESS DOOR. PROPOSED 60-kW NATURAL GAS EMERGENCY GENERATOR. EQUIPMENT PAD UNDER GENERATOR PER 4 STAIRS PROPOSED RETAINING WALL WITH FENCE ON TOP 1 FENCE ON TOP OF WALL, MATCH EXISTING STYLE. ATTACH TO WALL PER DETAIL 5 EXISTING RETAINING WALL (TO REMAIN) INSTALL SINGLE MAIN DOOR TO RELOCATE ACCESS TO BUILDING PROPOSED RETAINING WALL PLAN CONCRETE WALL TO BE HAVE PATTERNED FORM LINER SELECTED BY CITY TO RESEMBLE EXISTING RETAINING WALL CONCRETE CORNER REINFORCEMENT 6 1/2" PREMOLDED JOINT FILLER AT INTERFACE BETWEEN BUILDING AND RETAINING WALL FULL HEIGHT. LOUVER TO BE RELOCATED 7'-6" 45'-0" 7'-9" 5'-8"2'-9" 4'-1" 11'-11" 3 35'-6" PROPOSED 5'-8" x 7'-9" CONCRETE PAD 2 11" DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D R E T A I N I N G W A L L SE C T I O N S A N D D E T A I L S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F DM F MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 1 . D W G SHOWN S02 8 24 FENCE POST SLAB RETAINING WALL CONNECTION 5 EQUIPMENT PAD 4" MIN. BEYOND EQUIPMENT BOLTS, TYP. 31 2" UNLESS OTHERWISE NOTEDCAST-IN-PLACE CONCRETE #4 DOWELS, EACH CORNER AND 18" O.C., 3" EMBEDMENT INTO FLOOR CAST-IN-PLACE CONCRETE, ROUGHEN FLOOR UNDER PAD PRIOR TO POURING PAD. PROVIDE #4@12" O.C. AT TOP FACE WITH 11 2" CLEAR COVER 3 4" CHAMFER, ALL OUTER EDGES 4 3/8" A36 THICK BASE PLATE 6" TYP 8" 8" 1" TYP FENCE POST 2" MIN TO CONC EDGE 1 2" SST CONCRETE ANCHOR WITH 3" EMBEDMENT, TYP. 4 PLAN MIN. LAP MIN. LAP NOTE: THE SIZE AND SPACING OF TYPICAL CORNER REINFORCING SHALL MATCH THE SIZE AND SPACING OF THE HORIZONTAL WALL REINFORCING. WHERE PERPENDICULAR WALLS HAVE DIFFERENT HORIZONTAL WALL REINFORCING, PROVIDE CORNER BARS TO MATCH THE HORIZONTAL WALL REINFORCING WITH THE GREATEST AREA OF STEEL. HORIZONTAL WALL REINFORCEMENT, TYP. WALL REINFORCEMENT, TYP. CORNER BARS TO MATCH WALL REINFORCEMENT EXCEPT AS NOTED ON PLANS STANDARD HOOK, TYP. TYPICAL CONCRETE WALL INTERSECTION / CORNER 6 TYPICAL PAD REINFORCING DETAIL 4" PER PLAN CAST-IN-PLACE CONCRETE LANDING. SLOPE TOWARD ROAD AT 2% MIN. #3 @ 12" O.C., EACH WAY, CENTER OF SLAB. 2 TYPICAL RETAINING WALL SECTION 1 1'-0" 4'-8" 2'-4" 1'-6" 7'-9" 1'-0" 10'-0" PROVIDE CONTRACTOR DESIGNED SHORING. SEE NOTES THIS PAGE GRAVEL BACKFILL FOR WALLS, 12" MIN. EXISTING SOIL JOINT UTILITY TRENCH EXISTING SIDEWALK TO BE REMOVED AND REPLACED IN KIND CONCRETE WALL TO BE HAVE PATTERNED FORM LINER SELECTED BY CITY TO RESEMBLE RECLAIMED BLOCKS PROPOSED GAS LINE FOR GENERATOR MIN 6" THICK LAYER OF CSBC COMPACTED 95% MAX DRY DENSITY PER MODIFIED PROCTOR #5 REBAR @ 12" O.C. B.W., E.F. IN WALL, 2" CLEAR COVER TYP. PERFORATED 6" CPE PIPE WRAPPED IN DRAINAGE FABRIC WITH 1.5% SLOPE MIN. FENCE POST ON TOP OF WALL, CONNECTED PER 5 PROPOSED GAS METER #5 @ 12" O.C., E.W. IN TOP FACE WITH 2" COVER NORMAL WEIGHT CONCRETE FILL 1.5% MIN, 2% MAX MIN. 6" COMPACT NATIVE SOIL OVER GRAVEL BACKFILL STAIR REINFORCEMENT DETAIL 3 ROUGHEN CONCRETE WHERE POURING STAIRS OVER RETAINING WALL TOE PREFABRICATED STAIR NOSINGS, TYP. EA. STEP #4 LONG BAR AT EACH NOSE #4 DOWEL EPOXY INTO IN EACH CORNER TYP. EMBED 4" MIN INTO TOE AND STAIRS WSDOT CLASS 4000 CONCRETE CONCRETE FILL 7" TYP. 11" TYP. #4@ 12" O.C. E.W. CONTRACTOR DESIGNED SHORING NOTES 1.THE NATIVE SOIL CONSISTS OF LOOSE SAND AND GRAVEL. 2.MAINTAINING THE STABILITY OF THE EXCAVATION AND SLOPE IS THE CONTRACTOR'S RESPONSIBILITY AND ANY SHORING OR OTHER STABILIZING METHOD SHALL BE CONTRACTOR-DESIGNED. CONTRACTOR SHALL SUBMIT A PLAN FOR PROPOSED MEANS OF EXCAVATION AND WALL CONSTRUCTION INCLUDING TIMELINE, FOR APPROVAL BY ENGINEER OF RECORD. 3.SETTLEMENT MONITORING AT STRUCTURES ON ADJACENT PROPERTIES SHALL BE CONDUCTED BY THE CONTRACTOR TWO WEEKS BEFORE, DURING AND TWO WEEKS AFTER CONSTRUCTION TO DOCUMENT ANY POTENTIAL FOR CONSTRUCTION RELATED SETTLEMENT AT THE MONITORED LOCATIONS. #5 @ 12" O.C., E.W. IN SIDE FACE. PROVIDE COVER 2" GREATER THAN LARGEST DEPTH FROM CONCRETE FORM LINER ROUGHEN CONCRETE FACE BEFORE POURING NORMAL WEIGHT CONCRETE FILL PROPOSED RETAINING WALL (NORMAL WEIGHT CONCRETE, 150 PCF, WSDOT CLASS 4000) #5 REBAR @ 12" O.C. B.W., E.F. IN TOE, 2" CLEAR COVER TYP. #4 DOWEL EMBED 4" INTO SLAB, TYP. AT EACH CORNER #4 DOWEL EPOXY INTO INTO TOP STAIR AT EACH CORNER 1 2" CHAMFER AT ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: LI F T S T A T I O N S T R U C T U R A L DE T A I L S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F DM F MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 1 . D W G SHOWN S03 9 24 DOOR SAWCUT ELEVATION SAWCUT EXTENTS APPROXIMATELY SHOWN AROUND LOUVER. CONTRACTOR TO FIELD VERIFY DIMENSIONS SAWCUT AROUND EXISTING LOUVER AND INSTALL DOOR. FILL AREAS BETWEEN DOOR FRAME AND DOOR WITH GROUT DOOR SAWCUT PLAN DOOR AND FRAME SCHEDULE NOTE: DOOR SHALL INCLUDE WEATHER STRIPPING (ALL SIDES), KNOB OPERATOR WITH LOCK, FLUSH EXTENSION BOLTS, ASTRAGAL, LATCH GUARD AND EXIT DEVICE. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2" FRAME, TYP. ALL AROUND FRAME WIDTH FRAME HEIGHT TYPE 1 DOOR TYPES: PROPOSED DOOR SHALL MATCH THE SIZE OF THE EXISTING ABANDONED DOOR. MONORAIL CONNECTION TO CONCRETE WALL 501 8" 1" 1" 4" 4" CL CL 8" 1"3" 11 2" 3" 11 2" 11 2" 10" FROM TOP OF WALL, TYP. Ø1 2" BOLT, TYP. CL CL CL CL 4"X6"X1/4" A36 SHEAR TAB, E70XX 3/16" WELD ALL AROUND TO STEEL BASEPLATE 1/4" A36 STEEL PLATE, TYP. W8X10 MONORAIL BEAM 1 2" THREADED ROD WITH MIN 3" EMBEDMENT INTO CONCRETE WALL, SECURE WITH HILTI HIT-RE 500 V3 EPOXY, TYP. GRATING SUPPORT - ANGLE 1 2" CONCRETE ANCHOR @ 2'-0" O.C. WITH 3" EMBEDMENT L2x3x1 4", LLV COVERED 2" FRP GRATING 502 11 2" 1" MIN BEARING CL DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: ST R U C T U R A L N O T E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F DM F MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - C 2 0 1 . D W G SHOWN S04 10 24 SAFETY SAFETY AND STRUCTURAL STABILITY DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURES HAVE BEEN DESIGNED TO RESIST THE DESIGN LOADS ONLY AS COMPLETED STRUCTURE. OPENINGS OPENINGS FOR PIPES, DUCTS, CONDUITS, ETC. ARE NOT ALL SHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE AND PROVIDE OPENINGS AS REQUIRED TO ACCOMMODATE ALL WORK SHOWN OR SPECIFIED IN TECH CONTRACT DOCUMENTS AND OTHERWISE REQUIRED FOR FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT. REINFORCE AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS OTHERWISE SHOWN. STANDARD DETAILS THE STANDARD DETAILS DEPICT TYPICAL DETAILING TO BE USED ON THIS PROJECT. IF CONDITIONS ARE NOT EXPLICITLY SHOWN ON THE DRAWING THEY SHALL BE MADE SIMILAR TO THE STANDARD DETAILS. OBTAIN APPROVAL OF ENGINEER IN WRITING FOR SIMILAR CONDITIONS PRIOR TO CONSTRUCTION. REINFORCED CONCRETE EMBEDDED ITEMS AND PENETRATIONS REFER TO OTHER DISCIPLINE DRAWINGS PRIOR TO CONSTRUCTION FOR EMBEDDED ITEMS AND PENETRATIONS NOT SHOWN ON STRUCTURAL DRAWINGS. AS REQUIRED TO ACCOMMODATE ALL WORK SHOWN OR SPECIFIED IN THE CONTRACT DOCUMENTS AND OTHERWISE REQUIRED FOR THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT REINFORCE AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS OTHERWISE SHOWN. JOINTS CONTINUOUS WATERSTOP SHALL BE INSTALLED IN JOINTS SUBJECT TO STATIC WATER PRESSURE. CONTRACTOR SHALL SUBMIT CONCRETE PLACEMENT PLAN IDENTIFYING JOINT TYPES, JOINT LOCATIONS AND CONCRETE PLACEMENT SEQUENCE. CHAMFERS PROVIDE 3/4" CHAMFERS AT ALL EXPOSED EDGES (AND 1/2" CHAMFERS AT JOINTS AS SHOWN) NOT ALL CHAMFERS MAY BE SHOWN ON DRAWINGS. GENERAL LOCATION 47.475854 N, 122.215228 W RISK CATEGORY II USE GROUP/OCCUPANCY GROUP U (UTILITY/MISC) CONSTRUCTION TYPE V-B DEAD LOADS: GENERAL CONCRETE 150 PCF GENERAL STEEL 490 PCF SNOW LOAD DATA: GROUND SNOW LOAD, pg:25 PSF WIND DESIGN DATA: BASIC WIND SPEED, V 109 MPH WIND EXPOSURE B EARTHQUAKE DESIGN DATA: RISK CATEGORY(S)II SEISMIC IMPORTANCE FACTOR(S), Ie 1.0 MAPPED SPECTRAL RESPONSE PARAMETERS Sms = 1.7 DESIGN SPECTRAL RESPONSE PARAMETERS Sds = 1.133 SEISMIC DESIGN CATEGORY D GEOTECHNICAL INFORMATION: ALLOWABLE (NET) SOIL BEARING:2,000 PSF SOIL SITE CLASS:D (DEFAULT) DESIGN CRITERIA SCOPE THE NOTES ON THIS SHEET AND THE STANDARD STRUCTURAL DETAILS ARE GENERAL AND APPLY TO THE ENTIRE PROJECT WHETHER SPECIFICALLY CALLED OUT OR NOT, EXCEPT WHERE THERE ARE SPECIFIC INDICATIONS TO THE CONTRARY ON STRUCTURAL SHEETS. IF THERE ARE QUESTIONS, THEY SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER AND ANSWERED IN WRITING PRIOR TO CONSTRUCTION. APPLICABLE SPECIFICATIONS AND CODES ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, 2021 BUILDING CODE WITH ALL APPLICABLE STATE AND LOCAL AMENDMENTS. GENERAL THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. METHODS, PROCEDURES, AND SEQUENCE OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. LINES SHOWN ON DRAWINGS MAY BE ASSOCIATED WITH CAD MODELING AND MAY NOT REPRESENT REQUIRED OR ALLOWED JOINTS. SEE DETAILS FOR CLARIFICATION ON REQUIRED AND ALLOWED JOINTS. APPLICABLE SHOP DRAWINGS AND STRUCTURAL CALCULATIONS SHALL BE STAMPED BY A PROFESSIONAL ENGINEER IN WASHINGTON STATE. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS OF EXISTING CONSTRUCTION AS REQUIRED TO COORDINATE NEW CONSTRUCTION. SUBMIT REQUIRED CHANGES FOR APPROVAL. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN LIVE LOAD FOR THE STRUCTURE. PROVIDE SHORING AND/OR BRACING WHERE LOADS EXCEED DESIGN CAPACITY AND WHERE STRUCTURES HAVE NOT ATTAINED DESIGN STRENGTH. GENERAL DESIGN STANDARDS AND REFERENCES: GENERAL CONCRETE STRUCTURES: ACI 318-19 CONCRETE LIQUID HOLDING STRUCTURES: ACI 350-06 AND ACI 350.3-06 CONCRETE MIX DESIGNS: SPEC 3.31 STRUCTURAL CONCRETE:F'C = 4500 PSI SPEC 3.31.32 HYDRAULIC CONCRETE: F'C = 4500 PSI REINFORCING STEEL: FY = 60 KSI UNLESS NOTED OTHERWISE CONCRETE COVER PROTECTION UNLESS OTHERWISE NOTED: FOOTINGS AND OTHER UNIFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. . . . . . . . . . . .. 3" FORMED SURFACES EXPOSED TO EARTH (WALLS BELOW GRADE), WATER OR WEATHER (#6 BARS OR LARGER) . . . . . . . . . . 2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS . . . . . . . . . . . . . . 2" SLABS AND INTERIOR FACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2" SEE DRAWINGS FOR EXCEPTIONS REINFORCING STEEL REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315-18 AND 318-19. LAP ALL REINFORCEMENTS IN ACCORDANCE WITH THE "REINFORCING SPLICE AND DEVELOPMENT LENGTH SCHEDULE" - SEE THIS SHEET. PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS PER STRUCTURAL DETAILS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. ABSOLUTELY NO WELDING OF REINFORCING BARS OR TORCHING TO BEND REINFORCING BARS SHALL BE ALLOWED WITHOUT SPECIFIC APPROVAL FROM THE STRUCTURAL ENGINEER. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. FORMWORK FORMWORK SHALL BE IN ACCORDANCE WITH ACI - 347 "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK". FORMS SHALL BE DESIGNED BY THE CONTRACTOR. BRACING SHALL BE PROVIDED AS REQUIRED OR UNTIL THE CONCRETE HAS REACHED ITS SPECIFIED 28 - DAY STRENGTH. ALL SHORING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. FORMWORK, SUPPORTS, AND SHORING SHALL PROVIDE FINISHED CONCRETE SURFACES AT ALL FACES: LEVEL, PLUMB, AND TRUE TO DIMENSIONS AND ELEVATIONS SHOWN IN THE DRAWINGS. FORMS SHALL BE CLEAN AND FREE OF DEBRIS AND ALL WIRE TIES BENT AWAY FROM FINISHED SURFACES PRIOR TO CONCRETE INSTALLATION. REINFORCEMENT SPLICE AND DEVELOPMENT SCHEDULE 300 #6 #5 #4 #3 BAR REINFORCEMENT SPLICE AND DEVELOPMENT SCHEDULE Ld, MINIMUM STRAIGHT DEVELOPMENT LENGTHS MINIMUM LAP SPLICE LENGTHS CLASS B 1.3xLd 1.3xLd 1.3xLd 1.3xLd #7 #8 #9 #10 #11 Ldh, MINIMUM HOOKED DEVELOPMENT LENGTHS REFERENCE: ACI 318-19 CHAPTER 25 1.) REINFORCEMENT FY = 60 KSI, CONCRETE F'C = 4500 PSI 2.) REINFORCEMENT UNCOATED, NORMAL WEIGHT CONCRETE 3.) "MIN" IF: CLEAR SPACING OF BARS OR WIRES BEING DEVELOPED OR LAP SPLICED NOT LESS THAN BAR DIA., CLEAR COVER AT LEAST BAR DIA., AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN CODE MIN 4.) "OTHER" IF: DOES NOT MEET REQUIREMENTS FOR MIN DEVELOPMENT LENGTH 5.) "BOT" IF: LESS THAN 12" FRESH CONCRETE PLACED BELOW HORZ. REINFORCEMENT 6.) "TOP" IF: MORE THAN 12" FRESH CONCRETE PLACED BELOW HORZ. REINFORCEMENT 7.) CONTACT ENGINEER FOR ADJUSTED PARAMETERS TOP MIN TOP OTHER 1.3xLd 1.3xLd 1.3xLd 1.3xLd 1.3xLd BOT MIN BOT OTHER 6" 9" 12" 16" 20" 24" 34" 40" 29" 27" 35" 44" 53" 77" 88" 111" 123" 99" 21" 27" 34" 41" 59" 68" 86" 95" 76" 18" 24" 30" 35" 51" 59" 74" 82" 66" 14" 18" 24" 27" 40" 45" 57" 63" 51" JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - M E C X . D W G SHOWN M01 11 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: DE M O L I T I O N P L A N CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F EXISTING PLAN A M01 A M01 SECTION A M01 OBLIQUE 18" INLET PIPE 20" OPENING MANHOLE RING AND COVER, TYP. EXISTING DISCHARGE PIPE AND FITTINGS, TYP. EXISTING PLATE AND OPENING OUTLINE, TO BE REMOVED, TYP. OF 2 6" GALVANIZED STEEL PIPE FLOAT GUIDE EXISTING PUMP, TO BE REMOVED, TYP. OF 2 11.99' 20.41' 21.99' 23.41' 16.29' CL 14.99' EXISTING DISCHARGE PIPE AND FITTINGS, TO BE REMOVED, TYP. NOTE: TOP LEVEL FLOOR HIDDEN FOR CLARITY. NOTE: CONTRACTOR SHALL ENSURE CONTINUOUS PUMPING OPERATIONS DURING WET WEATHER WORK BY KEEPING ONE PUMP IN OPERATION, PROVIDING TEMPORARY PUMPING EQUIVALENT IN CAPACITY TO THE EXISTING PUMPS, OR SCHEDULING WORK THAT WOULD SHUT DOWN THE PUMPS DURING A PERIOD OF PROJECTED DRY WEATHER. COSTS ASSOCIATED WITH TEMPORARY PUMPING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCIDENTAL TO "MECHANICAL" (BID ITEM 16) NOTE: IF THE PUMP REPLACEMENT WORK WILL NOT BE DELIVERED IN A PERIOD OF PROJECTED DRY WEATHER, THE CONTRACTOR SHALL ENSURE CONTINUOUS PUMPING OPERATIONS DURING WET WEATHER WORK BY KEEPING ONE PUMP IN OPERATION OR PROVIDING TEMPORARY PUMPING EQUIVALENT IN CAPACITY TO THE EXISTING PUMPS. COSTS ASSOCIATED WITH TEMPORARY PUMPING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCIDENTAL TO "MECHANICAL" (BID ITEM 16) JD MR J F Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - P - M E C P . D W G SHOWN M02 12 24 DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: PR O P O S E D M E C H A N I C A L P L A N CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PROPOSED PLAN A M02 A M02 SECTION A M02 OBLIQUE NOTE: TOP LEVEL FLOOR HIDDEN FOR CLARITY. SUBMERSIBLE PUMP, TYP. OF 2 12"x10" DI ECCENTRIC REDUCER (FLxFL) NOTE: DISCHARGE PIPING IDENTICAL FOR ALL PUMPS. 12" DI SPOOL (FLxFL), LENGTH 4'-9" 12" DI 90° BEND (FLxFL), TYP. OF 2 12" CHECK VALVE (FLxFL), TYP. OF 2 EXISTING PUMP PLATE OPENING, TO BE ENLARGED, TYP. OF 2 12" KNIFE GATE VALVE (FLxFL), TYP. OF 2 PROPOSED ENLARGED PUMP PLATE OPENING, TYP. OF 2 3'-6", TYP. APPROX. 6'-11", TYP. 2'-21 2"10'-11 2" W8X10 MONORAIL BEAM CONNECTION TO CONCRETE WALL AT EACH END OF MONORAIL CL 501 S03 2" COVERED FRP GRATING SPANNING SHORT DIRECTION OVER PROPOSED OPENING. INDIVIDUAL PANEL WEIGHTS NOT TO EXCEED 50 POUNDS. GRATING SUPPORT ALONG LONG EDGE OF OPENING, TYP. 502 S03 HARRINGTON 1 2-TON UNDERHUNG HAND CHAIN HOIST WITH GT GEARED TROLLEY OR APPROVED EQUAL W8X10 MONORAIL ABOVE PUMPS NOTE: CONTRACTOR SHALL ENSURE CONTINUOUS PUMPING OPERATIONS DURING WET WEATHER WORK BY KEEPING ONE PUMP IN OPERATION, PROVIDING TEMPORARY PUMPING EQUIVALENT IN CAPACITY TO THE EXISTING PUMPS, OR SCHEDULING WORK THAT WOULD SHUT DOWN THE PUMPS DURING A PERIOD OF PROJECTED DRY WEATHER. COSTS ASSOCIATED WITH TEMPORARY PUMPING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCIDENTAL TO "MECHANICAL" (BID ITEM 16) NOTE: IF THE PUMP REPLACEMENT WORK WILL NOT BE DELIVERED IN A PERIOD OF PROJECTED DRY WEATHER, THE CONTRACTOR SHALL ENSURE CONTINUOUS PUMPING OPERATIONS DURING WET WEATHER WORK BY KEEPING ONE PUMP IN OPERATION OR PROVIDING TEMPORARY PUMPING EQUIVALENT IN CAPACITY TO THE EXISTING PUMPS. COSTS ASSOCIATED WITH TEMPORARY PUMPING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCIDENTAL TO "MECHANICAL" (BID ITEM 16) ONE-LINE DIAGRAM INFORMATION GENERAL NOTES LADDER LOGIC SYMBOL LEGEND INSTRUMENT METERINDICATE TYPE BY LETTER VALVE SYMBOLS ABBREVIATIONSONE-LINE DIAGRAM SYMBOLS LIGHTING FIXTURES/DEVICESPANELBOARDS, SWITCHES, AND EQUIPMENT GROUNDING SYSTEM SYMBOLS ELECTRICAL SITE PLAN SYMBOLS RECEPTACLES AND JUNCTION BOX SYMBOLS FIRE SYSTEM SYMBOLS ADDITIONAL SYMBOLS RACEWAY LEGEND SITE PLAN LEGEND BUILDING OR FACILITY PLAN LEGEND SWITCH OUTLETS AP B KM S Ja n 2 3 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 1 . D W G SHOWN E01 13 24 EL E C T R I C A L L E G E N D CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PUMP CONTROL PANEL, "PCP", 480V, 3Ø, 4W, NEMA 4X, 42 KAIC WITHSTAND GND BUS NEUTRAL SPD "L" 240/120V 480V 10 kVA 1Ø, 3W, 240/120V 3% REACTORS 3% REACTORS ONE-LINE DIAGRAM 200/3 TM DIGITAL METER GND BUS S/N GROUNDING MAIN SERVICE DISCONNECT SWITCH AUTOMATIC TRANSFER SWITCH, "ATS" STANDBY GENERATOR GROUND PER N.E.C. M HARMONIC FILTER HARMONIC FILTER PUMP 1 (15 HP)21.0 A X 1.25 =26.3 AMPS PUMP 2 (15 HP)21.0 A X 1.00 =21.0 AMPS PUMP STATION HEATER (5 KW)6.7 A X 1.00 =6.7 AMPS LIGHTING TRANSFORMER (10 kVA)12.1A X 1.00 =12.1 AMPS TOTAL 66.1 AMPS 100/3 TM 200/3 TM, SE 30/3 TM 30/3 TM 30/2 TM 60KW EXISTING SECONDARY POWER EXISTING SECONDARY POWER HAND HOLE 4 MAIN SERVICE DISCONNECT SWITCH LIGHTING TRANSFORMER 2 3 PEDESTAL REBAR MAT UFER CONNECTION #6 MIN. #4 MIN. ATS WET WELL VAULT CLASS I DIVISION 2 AREA PROVIDE PLASTIC BUSHING AT END OF CONDUIT, TYP. EXISTING WET WELL PROPOSED SEAL-OFF, TYP. NEMA 4X SS INSTRUMENTATION AND CONTROL JUNCTION BOX MOUNTED INSIDE EXTERIOR ENCLOSURE. NEMA 4X SS POWER JUNCTION BOX MOUNTED INSIDE EXTERIOR ENCLOSURE. 1 OUTSIDE AP B KM S Ja n 2 2 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 2 . D W G SHOWN E02 14 24 EL E C T R I C A L O N E - L I N E CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F INSIDE UTILITY METER 1. UTILITY METERING. METER BASE AND ENCLOSURE BY CONTRACTOR PER SERVING UTILITY REQUIREMENTS. METER BY PUGET SOUND ENERGY. 2. FUSING OR CIRCUIT BREAKER PER SURGE PROTECTION DEVICE MANUFACTURER'S RECOMMENDATION. 3. SEE GROUNDING DETAIL, THIS SHEET. 4. GROUND ROD PER N.E.C. (TYPICAL). SEE DWG NO. E11 FOR DETAIL. 5. SEE DWG NO. E12 FOR CONDUIT AND CONDUCTOR SCHEDULE. 6. SEE DWG NO. E12 FOR ELECTRICAL EQUIPMENT SCHEDULE. ELECTRICAL NOTES STATION LOAD CALCULATIONS #4 MIN. BOND TO EQUIPMENT PEDESTAL STRUCTURAL STEEL 15/3 TM PUMP STATION HEATER PUMP 1 PUMP 2 PROPOSED EXTERIOR JUNCTION BOX ENCLOSURE 480/277 VOLT 3 INSTALL SEAL-OFF PER PLAN 15/3 N7 ELECTRICAL SITE PLAN STANDBY GENERATOR. SEE DWG NO. E10 FOR DETAILS. EXISTING METER BASE TO BE REMOVED ELECTRICAL EQUIPMENT PEDESTAL. SEE DWG NO. E09 FOR DETAILS. 1. THIS PLAN IS DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATION OF ELECTRICAL ITEMS. NOT ALL ELECTRICAL, MECHANICAL, STRUCTURAL OR ELEMENTS ARE SHOWN. 2. SEE DWG NO. E12 FOR CONDUIT AND CONDUCTOR SCHEDULE. ELECTRICAL NOTES XX EXISTING PUMP STATION BUILDING AP B KM S Ja n 2 2 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 3 . D W G SHOWN E03 15 24 EL E C T R I C A L S I T E P L A N CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F EXISTING SECONDARY POWER HAND HOLE JUNCTION BOX ENCLOSURE. SEE DWG NO. E11 FOR DETAILS. EXISTING ANTENNA. INTERCEPT EXISTING ANTENNA MAST WITH PROPOSED CONDUIT. PROPOSED GAS MAIN PER DWG NO. C03 AP B KM S Ja n 1 6 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 4 . D W G SHOWN E04 16 24 EL E C T R I C A L P L A N 1 CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PUMP STATION INTERIORPUMP STATION EXTERIOR PUMP STATION EXTERIOR PUMP STATION INTERIOR 1. ALL EXISTING CONDUIT IN PUMP STATION INTERIOR TO BE REMOVED. 2. FOLLOWING CONDUIT REMOVAL, CONTRACTOR TO SEAL EXISTING UNUSED CONDUIT BUILDING PENETRATIONS AND MAKE WEATHERTIGHT. ELECTRICAL NOTES EXISTING METER AND MAIN SERVICE DISCONNECT, TO BE REMOVED. EXISTING GENERATOR RECEPTACLE, TO BE REMOVED. EXISTING RADIO ANTENNA AND MAST TO REMAIN IN PLACE. EXISTING COMBINATION LIGHT SWITCH/RECEPTACLE TO BE REMOVED. EXISTING BUILDING INTRUSION SWITCH TO BE REMOVED. PROPOSED EXPLOSION-PROOF INTRUSION SWITCH TO BE INSTALLED IN SAME LOCATION. EXISTING INTRUSION DISABLE SWITCH TO BE REMOVED. PROPOSED EXPLOSION-PROOF INTRUSION DISABLE SWITCH TO BE INSTALLED IN SAME LOCATION. EXISTING ELECTRICAL EQUIPMENT, TO BE REMOVED EXISTING HEATER TO BE REMOVED. PROPOSED EXPLOSION-PROOF HEATER AND DISCONNECT TO BE INSTALLED IN SAME LOCATION. EXISTING LIGHT FIXTURES, TO BE REMOVED, TYP. EXISTING MOTOR STARTERS, TO BE REMOVED EXISTING PUMPS TO BE REMOVED EXISTING SMOKE DETECTOR TO BE REMOVED EXISTING TELEMETRY PANEL, "RTU", TO BE RELOCATED TO PROPOSED ELECTRICAL SHELTER. INSTALL PROPOSED LEVEL TRANSMITTER JUNCTION BOX IN SAME LOCATION AND SPLICE EXISTING LEVEL TRANSMITTER CABLE TO FIELD WIRING AT TERMINAL BLOCKS INSIDE JUNCTION BOX. RECONNECT EXISTING LEVEL TRANSMITTER CABLE TO TERMINAL BLOCKS. EXTEND EXISTING CONDUIT WITH PROPOSED CONDUIT AS NECESSARY. EXISTING POWER DISTRIBUTION PANEL, TO BE REMOVED EXISTING MANUAL TRANSFER SWITCH, TO BE REMOVED EXISTING FLOOD SWITCH TO BE REMOVED EXISTING PRESSURE SWITCHES, TO BE REMOVED. TYP. MB D KM S Ja n 1 6 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 9 . D W G SHOWN E05 17 24 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: EL E C T R I C A L P L A N 2 WET WELL ELECTRICAL PLAN SUBMERSIBLE PUMP, TYP. OF 2 PROPOSED JUNCTION BOX ENCLOSURE. SEE DWG NO. E11 FOR DETAILS. SST UNISTRUT, SPAN ACROSS AVAILABLE SPACE IN WET WELL. MOUNT TO 4-HOLE SST "L" BRACKET. EXISTING LEVEL TRANSMITTER M M WET WELL FLOATS P9 P10 C9 PUMP PLATE OPENING, TYP. STATION INTERIOR ELECTRICAL PLAN J C6 C7 A1 A1 A1 SC F F ROUTE ALL CONDUITS EXITING PUMP STATION TO THIS AREA. INSTALL SEAL-OFFS INSIDE PUMP STATION, TYP. OF ALL CONDUITS. CONDUITS TO PENETRATE WALL AND CONTINUE UNDERGROUND OUTSIDE OF PUMP STATION. H1 PROPOSED LEVEL TRANSMITTER JUNCTION BOX, MOUNTED IN SAME LOCATION AS EXISTING TELEMETRY PANEL 1.SEE ELECTRICAL SITE PLAN, DWG NO. E03, FOR CONTINUATION. 2.EXPLOSION PROOF SINGLE GANG BOX SURFACE MOUNTED ON WALL. 3.ROUTE ALL PROPOSED CONDUITS ALONG WALLS AND CEILING TO AVOID TRIPPING HAZARD. 4.SEE DWG NO. E12 FOR CONDUIT AND CONDUCTOR SCHEDULE. 5.SEE DWG NO. E12 FOR ELECTRICAL EQUIPMENT SCHEDULE. 6.SEE DWG NO. E12 FOR LIGHTING SCHEDULE. ELECTRICAL NOTES X A# XX G E C8 C4 C3 P6 C5 P13 J3 P7 J5 P8 J6 C2 J2 ROUTE EXISTING LEVEL TRANSMITTER CABLE TO PROPOSED JUNCTION BOX 1 1 1 1 PUMP STATION DOOR 2 2 PUMP STATION DOOR CONDUITS TO PENETRATE WALL BELOW GRADE INSIDE WET WELL. STUB UP CONDUITS INTO JUNCTION BOX ENCLOSURE. PUMP 1 PUMP 2 CLASS I DIVISION 2 AREA CLASS I DIVISION 2 AREA CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F D AP B KM S Ja n 1 6 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 4 . D W G SHOWN E06 18 24 PU M P C O N T R O L P A N E L D E T A I L S 1 CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F 6' - 0" MAX. 6' - 0" MAX. WARNING 480 VAC KEEP OUT NAMEPLATE NEMA 4X SS ENCLOSURE, 24" DEEP. RAINIER STORMWATER PUMP STATION PUMP CONTROL PANEL WARNING LABEL PUMP CONTROL PANEL EXTERIOR LAYOUT SIDE-MOUNTED PANEL AIR CONDITIONER. NVENT SPECTRACOOL, NO SUBSTITUTIONS. SIZE AIR CONDITIONER TO ADEQUATELY COOL ALL EQUIPMENT WITHIN ENCLOSURE. COOLING SETPOINT SHALL BE 90°F. PAD-LOCKABLE HANDLE AP B KM S Ja n 1 6 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 4 . D W G SHOWN E07 19 24 PU M P C O N T R O L P A N E L D E T A I L S 2 CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F PUMP CONTROL PANEL INTERIOR SWING DOOR LAYOUT PUMP CONTROL PANEL DISCONNECT SWITCH PUMP START COUNT METER, TYP. PUMP 1 HOURS 0 0 0 0 0 0 START 0 0 0 0 0 0 PUMP 2 HOURS 0 0 0 0 0 0 START 0 0 0 0 0 0 VFD FAULT LIGHT, TYP. VFD DISABLE LIGHT, TYP. VFD DISABLE PUSHBUTTON, TYP. PUMP RUN TIME METER, TYP. VFD KEYPAD MODULE, TYP. MOUNT INTRUSION SWITCH TO INSIDE OF ENCLOSURE PUMP RUNNING LIGHT, TYP. PUMP SEAL FAIL LIGHT, TYP. PUMP OVERTEMPERATURE LIGHT, TYP. ALARM RESET PUSHBUTTON, TYP. POWER MONITOR AP B KM S Ja n 1 6 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 4 . D W G SHOWN E08 20 24 CO N T R O L L O G I C D I A G R A M CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F DIAGRAM 1: PUMP CONTROL LOGIC, TYP. DIAGRAM 2: BUILDING SMOKE DETECTOR CIRCUIT 1. THE TYPE OF PUMP PROTECTION RELAY MAY VARY DEPENDING ON THE SELECTED PUMP MANUFACTURER. CONTRACTOR SHALL PROVIDE AND INSTALL THE APPROPRIATE PUMP PROTECTION RELAY EQUIPMENT AS RECOMMENDED BY THE PUMP MANUFACTURER. CONTROL WIRING IN THE PUMP CONTROL PANEL SHALL BE MODIFIED AS NECESSARY TO ACCOMMODATE THE PROVIDED PUMP PROTECTION RELAY AT NO COST TO THE OWNER. ELECTRICAL NOTES 1. SEE ELECTRICAL SITE PLAN, DWG NO. E03 FOR CONTINUATION 1. SEE DWG NO. E12 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. SEE DWG NO. E12 FOR ELECTRICAL EQUIPMENT SCHEDULE. ELECTRICAL NOTES AP B KM S Ja n 1 5 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 5 . D W G SHOWN E09 21 24 EL E C T R I C A L E Q U I P M E N T P E D E S T A L DE T A I L S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F 5'-0" 1'-1" CLCL CL 7'-9" POST CONNECTION ELECTRICAL EQUIPMENT PEDESTAL PLAN VIEW UNISTRUT FRAMING. SPACING AS NEEDED FOR PANEL ATTACHMENTS HSS 4 1/2" x 4 1/2" x 5/16" POSTS, TYP. OF 2, HOT DIP GALVANIZE POST AND RAFTER PL 9" X 9" X 1/2" HSS 4.5X4.5X5/16 HILTI HIT-RE 500 V3 + HAS-V-36 1/2" W/ MIN 4" EMBEDMENT, OR APPROVED EQUAL BASE PLATE DETAIL 1601 UTILITY METER MAIN SERVICE DISCONNECT AUTOMATIC TRANSFER SWITCH, "ATS" PUMP CONTROL PANEL, "PCP" TELEMETRY PANEL, "RTU". INSTALL EXISTING TELEMETRY PANEL IN PROPOSED NEMA 4X SS 48" W, 72" H, 48" D ENCLOSURE. ELECTRICAL EQUIPMENT PEDESTAL FRONT ELEVATION VIEW 5'-0" UTILITY METER MAIN SERVICE DISCONNECT SWITCHAUTOMATIC TRANSFER SWITCH, "ATS"PUMP CONTROL PANEL, "PCP" (CONTAINS LIGHTING PANEL, "L") TELEMETRY PANEL, "RTU" P6P13 C4 J5 P4 P5 P3 P2P11 P1 C5 C3 C7 C8 C6 J6J4J2 J1 1601 WALL C1 P12C12 C2 P7 P8 C14 C13 "RTU" FRONT EDGE OF CONCRETE SLAB AP B KM S Ja n 1 5 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 6 . D W G SHOWN E10 22 24 GE N E R A T O R D E T A I L S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F APPROX. 8'-11" APPROX. 4'-0" 3" TYP. PROPOSED GENERATOR WITH SOUND ATTENUATED HOUSING EQUIPMENT PAD 4 GENERATOR PLAN VIEW EQUIPMENT PAD 4 PROPOSED GENERATOR WITH SOUND ATTENUATED HOUSING SECURE GENERATOR TO CONCRETE PAD PER MANUFACTURER'S INSTRUCTIONS PROPOSED CONCRETE PAD, SLOPE AWAY FROM GENERATOR PER DETAIL 1 ON S02 GENERATOR SIDE ELEVATION VIEW MB D KM S Ja n 1 5 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 8 . D W G SHOWN E11 23 24 EL E C T R I C A L D E T A I L S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F COPPER CONDUCTOR CADWELD TYPE TA. CADWELD CABLE TO CABLE TEE CONNECTION. COPPER CONDUCTOR CADWELD TYPE RR. CADWELD END CABLE TO UPPER REBAR CONNECTION. REBAR COPPER CONDUCTOR CADWELD TYPE GR 5/8" X 8' COPPER GROUND ROD.COPPER CONDUCTOR (TYPICAL) CADWELD TYPE XA. CADWELD CABLE TO CABLE CROSS CONNECTION.CADWELD CABLE TO GROUND ROD CONNECTION. GROUNDING CROSS DETAILGROUND TEE DETAIL GROUND TEE DETAIL GROUND REBAR DETAIL 5'-0" MIN. 4'-0" MIN. NEMA 1 SS ENCLOSURE, 20" DEEP. STUD MOUNTED SS GRATING ON FRONT AND SIDES OF EXTERIOR PANEL ENCLOSURE. SECURE TO CONCRETE SLAB WITH 1/2" SST CONCRETE ANCHORS, TYP. EMBED 3" MIN. INTERIOR JUNCTION BOX ENCLOSURE ELEVATION DETAIL POWER TERMINAL BLOCKS, TYPICAL AS REQUIRED. TO "PCP" POWER JUNCTION BOX, "PJB". SIZE JUNCTION BOX PER NEC BASED ON SITE SPECIFIC CONDUIT AND CONDUCTOR SIZES AND QUANTITIES. NEMA 4X SS ENCLOSURE, 12" DEEP. SECURE TO EXTERIOR PANEL. GROMMETED CABLE FITTING, TYPICAL. SEE DETAIL THIS SHEET. PERMANENT WIRING FROM "RTU" (WITH PERMANENT EXPLOSION-PROOF SEAL FITTING) POWER CABLE WITH CONDUCTORS INSIDE OVERALL JACKET (MANUFACTURER CABLE), TYP. TO WET WELL INSTRUMENTATION AND CONTROL TERMINAL BLOCKS, TYPICAL AS REQUIRED. TO "RTU" INSTRUMENTATION AND CONTROL JUNCTION BOX, "ICJB". SIZE JUNCTION BOX PER NEC BASED ON SITE SPECIFIC CONDUIT AND CONDUCTOR SIZES AND QUANTITIES. NEMA 4X SS ENCLOSURE, 12" DEEP. SECURE TO EXTERIOR PANEL. GROMMETED CABLE FITTING, TYPICAL. SEE DETAIL THIS SHEET. TO WET WELL PERMANENT WIRING FROM "PCP" (WITH PERMANENT EXPLOSION-PROOF SEAL FITTING) SEAL, TYP. EXTERIOR JUNCTION BOX TRANSMITTER CABLE FLOAT CABLE EXTERIOR JUNCTION BOX ENCLOSURE INTRUSION SWITCH FOR MAIN ENCLOSURE DOOR EXTERIOR JUNCTION BOX ENCLOSURE ELEVATION DETAIL KEY LOCK HOLE FIELD WIRE CONNECTIONS CABLE TRANSITION DETAIL (TYPICAL) CABLE, LENGTH AS NECESSARY TO REACH TERMINAL BLOCK TERMINATION BOX ENCLOSURE CORD GRIP (CGB), SIZE TO CABLE DIAMETER CABLE FROM WET WELL (TYP.) PROPOSED TERMINAL BLOCK WITHIN JUNCTION BOX ENCLOSURE SURFACE MOUNTED CONDUIT DETAIL ROOF TRUSSES (TYP) FLOOR (TYP) 1.) SIZE AND NUMBER OF CONDUIT VARIES. 2.) THIS DETAIL TYPICAL FOR ALL SURFACE MOUNTED CONDUIT. C-CHANNEL OFFSET BRACKET. SECURE CONDUIT TO BRACKET. CONDUIT (TYPICAL). CONDUIT SHALL BE NEATLY AND EQUALLY SPACED. CONDUIT SHALL BE PARALLEL WITH WALLS. TYPICAL WALL-MOUNTED ENCLOSURE 3" 3" 3" FINISH SURFACE PER PLAN RED ELECTRICAL WARNING TAPE CENTERED OVER EACH CONDUIT IN TRENCH (TYP) 36 " M I N - 4 8 " M A X F O R PR I M A R Y S E R V I C E CO N D U I T S MINIMUM DEPTH BELOW BOTTOM OF DEEPEST CONDUIT INSTALLED IN TRENCH 24 " M I N ( < 6 0 0 V ) NATIVE MATERIAL COMPACTED TO 95% PER ASTM D1557 OR AS REQUIRED PER PLAN 6" 9" COVER OVER HIGHEST CONDUIT IN TRENCH NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. TYPICAL ELECTRICAL TRENCH DETAIL ELECTRICAL CONDUIT NUMBER AND SIZE VARY AS PER SITE PLAN. MAINTAIN 12" SPACING BETWEEN TELEMETRY CONDUITS AND OTHER CONDUITS. SAND BEDDING MATERIAL PER WSDOT SPECIFICATION 9-03.13 EXISTING BUILDING CONDUIT PENETRATION DETAIL EXISTING BUILDING INTERIOR WALL EXISTING BUILDING EXTERIOR WALL FINISHED GRADE PROPOSED CONDUIT "LB", TYPICAL. PROPOSED CONDUIT TO I N T E R I O R E Q U I P M E N T CONTRACTOR SHALL GROUT FILL CONDUIT PENETRATION. GROUT SHALL BE DYED TO MATCH EXISTING BLOCK. GRADE 5/8"X8' LONG COPPER GROUND ROD 8-0" GROUND ROD DETAIL PROPOSED GROUND ROD BOX WITH COVER. SEE SPECIFICATIONS. SO TYPE CORD. GRC CONDUIT STRAPPED TO WALL WITH MINIMUM OF (2) STAINLESS STEEL PIPE CLAMPS SPACED EQUALLY APART. SO CORD CONNECTOR (TYPICAL).SURFACE MOUNTED J-BOX. LIQUID LEVEL SWITCH. SET TO SWITCH WITH 1/2" OF WATER ON FLOOR. FLOOD SWITCH DETAIL AP B KM S Ja n 1 5 , 2 0 2 6 Ja n 2 3 , 2 0 2 6 RE N 11 9 - 2 1 5 OA K R A I - D - E 0 7 . D W G SHOWN E12 24 24 EL E C T R I C A L S C H E D U L E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S CI T Y O F R E N T O N RA I N I E R S T O R M W A T E R P U M P S T A T I O N U P G R A D E S DWG NO.: DA T E DE S C R I P T I O N RE V I S I O N S BY RE V I E W EN G I N E E R : SA V E D A T E : RE V I E W E D : PL O T D A T E : CL I E N T : FI L E N A M E : SHEET NO.: JO B N O . : NO . 0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE: 0 01 / 2 3 / 2 6 IS S U E D F O R B I D D I N G CJ B MR J F ɸ ɸ ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE HEATER SCHEDULE LIGHTING FIXTURE SCHEDULE PANEL SCHEDULE L ɸ INSTRUMENTATION CONDUIT AND CONDUCTOR SCHEDULE CONTROL CONDUIT AND CONDUCTOR SCHEDULE POWER CONDUIT AND CONDUCTOR SCHEDULE