HomeMy WebLinkAboutAB-4316HORIZONTAL DATUM VERTICAL DATUM STEVENS AVE NW STORM SYSTEM PROJECT 1-800-424-5555 or 811 DEC 2025 SWP-27-4316 DATE UNDERGROUND SERVICE Call 48 Hours Before You Dig 4 PACE CJ CJ JF CJ RECORD DRAWINGS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991DATEAPPRBYREVISION DESCRIPTIONNO. APPROVED FOR CONSTRUCTION BY:DATE: Public Works Department CITY OF RENTON COVER C100 1 VICINITY MAP NOT TO SCALE STEVENS AVE NW STORM SYSTEM PROJECT N PROJECT LOCATION ST E V E N S A V E N W RA I N I E R A V E S SW SUNSET BLVD SW GRADY W A Y CITY OF RENTON KING COUNTY GENERAL ESC NOTES 1.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS. SEE THE "STANDARD DETAILS" SECTION OF THE PROJECT SPECIFICATIONS FOR REFERENCED CITY OF RENTON (COR) STANDARD DETAILS AND ANY REFERENCED WASHINGTON STATE DEPARTMENT OF TRANSPORTATION (WSDOT) STANDARD DETAILS. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS AND THE CONTRACT SPECIAL PROVISIONS 2.ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE CITY ENGINEER OR DESIGNATED REPRESENTATIVE. 3.PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH THE CITY ENGINEER FOR A PRECONSTRUCTION CONFERENCE. 4.A COPY OF THESE APPROVED PLANS AND PROJECT SPECIFICATIONS MUST BE ON THE SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5.THE CITY OF RENTON ASSUMES NO LIABILITY FOR THE ACCURACY OF THE RECORD INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES WITHIN PROPOSED EXCAVATION LIMITS. CONTACT UNDERGROUND UTILITY LOCATE SERVICE (1-800-454-5555) A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION TO OBTAIN ON-SITE UTILITY LOCATIONS. CONTRACTOR SHALL POTHOLE ALL UNDERGROUND GAS, WATER, SERVICE CONNECTIONS, AND ALL OTHER UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY CONFLICTS. PRECAUTIONS AND REMEDIAL MEASURES SHALL BE TAKEN AS REQUIRED TO PROTECT PERSONS AND PROPERTY AND TO AVOID DISRUPTION OF SERVICE. UNLESS OTHERWISE NOTED, PROTECT ALL UTILITIES FROM DAMAGE WHICH SHALL INCLUDE PROVIDING TEMPORARY SUPPORT SYSTEMS AND SHORING AROUND UTILITIES DURING EXCAVATION, IF AN EXISTING PRIVATE UTILITY CONFLICTS WITH PROPOSED IMPROVEMENTS, COORDINATE THE RELOCATION OF THE PRIVATE UTILITY WITH THE UTILITY OWNER UNLESS NOTED OTHERWISE OR DIRECTED BY THE ENGINEER. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF TRAFFIC CONTROL PLANS. CONTRACTOR SHALL SUBMIT PLANS TO ENGINEER FOR REVIEW AND APPROVAL AT LEAST 10 WORKING DAYS PRIOR TO IMPLEMENTATION. 7.EXISTING WATER LINE BEND AND BLOCKING ARE NOT SHOWN. 8.STORM SEWER LENGTHS ARE MEASURED BETWEEN CENTERS OF MANHOLES AND CATCH BASINS UNLESS OTHERWISE NOTED. 9.EXCEPT AS OTHERWISE NOTED, CATCH BASIN AND MANHOLE RIM ELEVATIONS GIVEN ARE APPROXIMATE. FINAL ELEVATIONS SHALL MATCH FINAL GRADE. 10.SITE CONSTRUCTION LIMITS (PRESERVATION LINES) COINCIDE WITH CITY RIGHT-OF-WAY AND UTILITY EASEMENTS UNLESS SHOWN OTHERWISE. 11.FOR CLARITY OF DRAWINGS, OVERHEAD POWER AND TELECOM ARE NOT SHOWN ON THE DRAWINGS. CONTRACTOR IS ADVISED THAT THERE ARE OVERHEAD POWER AND TELECOM THROUGHOUT PROJECT AREA, INCLUDING DIRECTLY OVER PROPOSED PIPE IMPROVEMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM THE WORK IN A SAFE MANNER AND IN ACCORDANCE WITH ANY REQUIREMENTS SET FORTH BY THE UTILITY OWNER AND APPLICABLE LAWS AND REGULATIONS. 12.NO STAGING AREA IS PROVIDED TO THE CONTRACTOR. ALL STAGING AREAS SHALL BE ON A CONTRACTOR SECURED AREA. ALL TESC REQUIREMENTS APPLY TO THE CONTRACTOR'S OBTAINED STAGING AREA. 13.CONTRACTOR SHALL COORDINATE WITH CITY OF RENTON WATER UTILITY ABOUT ANY RELOCATION OR MODIFICATION TO SERVICE LINES. TEMPORARY WATER SERVICE RELOCATION INCLUDES SERVICE LINE AND CONNECTION FITTINGS AND SHALL BE INCIDENTAL TO OTHER PAYMENT ITEMS. 14.ALL STORM DRAINAGE PIPES SHALL HAVE WATERTIGHT JOINTS PER MANUFACTURER RECOMMENDATION. 15.CONTRACTOR SHALL REPLACE ANY SURVEY MONUMENTS DISTURBED IN ACCORDANCE WITH SECTION 1-05.4 OF THE SPECIAL PROVISIONS AND CITY OF RENTON SURVEY STANDARDS AT NO ADDITIONAL COST TO THE CITY OF RENTON. 1.THE TEMPORARY EROSION AND SEDIMENT CONTROL (TESC) PLAN OUTLINED HEREIN IS CONCEPTUAL. THE CONTRACTOR IS REQUIRED TO SUBMIT A FINAL TEMPORARY WATER POLLUTION AND EROSION CONTROL PLAN IN ACCORDANCE WITH SPECIAL PROVISIONS SECTION 1-07.15. 2.THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/ESC SUPERVISOR UNTIL ALL CONSTRUCTION IS APPROVED. 3.THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL CLEARING AND GRADING SO AS TO ENSURE THAT THE TRANSPORT OF SEDIMENT TO SURFACE WATERS, DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES IS MINIMIZED. 4.THE ESC FACILITIES SHOWN ON THESE PLANS OR SPECIFIED HEREIN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT FOR CHANGING SITE CONDITIONS (E.G., ADDITIONAL SUMP PUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.). 5.THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/ESC SUPERVISOR AND MAINTAINED TO ENSURE CONTINUED PROPER FUNCTIONING. WRITTEN RECORDS SHALL BE KEPT OF WEEKLY REVIEWS OF THE ESC FACILITIES DURING THE WET SEASON (OCT. 1 TO APRIL 30) AND OF MONTHLY REVIEWS DURING THE DRY SEASON (MAY 1 TO SEPT. 30). 6.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON OR SEVEN DAYS DURING THE DRY SEASON SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). 7.ANY AREA NEEDING ESC MEASURES NOT REQUIRING IMMEDIATE ATTENTION SHALL BE ADDRESSED WITHIN FIFTEEN (15) DAYS. 8.THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN FORTY-EIGHT (48) HOURS FOLLOWING A STORM EVENT. 9.AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM. 10.WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM THICKNESS OF 2 TO 3 INCHES. 11.PUBLIC STREETS SHALL BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE CITY. FLUSHING OF STREETS WITH WATER WILL NOT BE ALLOWED. 12.IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY REQUIREMENTS, WASTEWATER FROM CEMENT CONCRETE MASONRY, OR ASPHALT CONCRETE CUTTING, OR POURING OPERATIONS SHALL NOT BE DISCHARGED INTO STORM DRAINAGE SYSTEMS OR SURFACE WATERS. IMPERVIOUS SURFACES CONTAMINATED WITH SEDIMENT FROM GRIT AND CUTTING, PLANING OR PULVERIZING OPERATIONS SHALL BE VACUUM-CLEANED TO PREVENT CONTAMINANTS FROM ENTERING THE STORM DRAINAGE SYSTEM OR SURFACE WATERS. 13.CATCH BASIN INSERTS SHALL BE PLACED AT ALL CATCH BASINS ALONG PIPE ALIGNMENT. SEE CITY OF RENTON STANDARD PLAN 216.30. 14.INSTALL SILT FENCING AROUND ENTIRE STAGING/STOCKPILE AREAS PER COR STANDARD PLAN 214. 15.TEMPORARY SEDIMENTATION TANK MAY BE REQUIRED IN CONTRACTOR STAGING AREA IF THE SILT FENCING IS NOT ADEQUATE. 16.KEEP PUBLIC AND PRIVATE ROADWAYS/PARKING LOTS, SIDEWALKS, AND TRAILS FREE OF DEBRIS AND SEDIMENT. 17.CONSTRUCT TEMPORARY STORMWATER BYPASSES AS NEEDED DURING CONSTRUCTION TO DIVERT STORMWATER AROUND TRENCHING AND PIPE INSTALLATION ACTIVITIES AND MAINTAIN DRAINAGE OF UPSTREAM STORMWATER. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF STORM DRAIN BYPASS PLAN. UNLESS OTHERWISE NOTED, BYPASSES ARE TO BE DESIGNED TO HANDLE THE VOLUME AND PEAK FLOWS OF THE 2-YEAR STORM EVENT AT A MINIMUM. SUBMIT AS PART OF WATER CONTROL PLAN. STORM DRAIN BYPASS PLAN SHALL ALSO ADDRESS THE DOWNSTREAM SYSTEM AND PREVENTION OF STORMWATER ENTERING THE WORK AREA BY BACKING UP FROM DOWNSTREAM. 18.ALL DEWATERING WATER AND RUNOFF WITHIN CONSTRUCTION AREAS SHALL BE TREATED VIA SEDIMENTATION, FILTRATION THROUGH VEGETATION IN APPROVED AREAS, OR PORTABLE FILTRATION SYSTEMS (UTILIZING TANKS AND FILTERS), AS NEEDED, PRIOR TO DISCHARGE TO DOWNSTREAM SYSTEM IN ORDER TO MEET ALL APPLICABLE LOCAL, STATE AND FEDERAL WATER QUALITY REGULATIONS. CONTRACTOR MAY ALSO DISCHARGE TO THE SANITARY SEWER SYSTEM AFTER OBTAINING APPLICABLE PERMITS AND MEETING PRETREATMENT REQUIREMENTS. LI N D A V E N W RENTON AV E S Sheet List Table Sheet Number Sheet Title C100 COVER C101 SITE PREPERATION PLAN C102 IMPROVEMENTS PLAN C103 DETAILS GENERAL NOTES 3 11 1 1 1 1 1 1 4 4 2 2 2 2 STEVENS AVE NW STORM SYSTEM PROJECT 1-800-424-5555 or 811 DEC 2025 SWP-27-4316 DATE UNDERGROUND SERVICE Call 48 Hours Before You Dig 4 PACE CJ CJ JF CJ RECORD DRAWINGS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991DATEAPPRBYREVISION DESCRIPTIONNO. APPROVED FOR CONSTRUCTION BY:DATE: Public Works Department CITY OF RENTON Feet 0 10 20 DEMOLITION KEY NOTES PRESERVE AND PROTECT EXISTING UTILITY. PRESERVE AND PROTECT EXISTING TREE. PRESERVE AND PROTECT EXISTING MAILBOXES. PRESERVE AND PROTECT EXISTING BLOCK WALL. 1 2 3 4 DEMOLITION NOTES 1.THE WORK UNDER THE CONTRACT INCLUDES ALL CLEARING NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT WORK. CLEARING, GRUBBING, AND DEMOLITION WORK SHALL BE INCIDENTAL TO THE PROJECT. 2.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED AND REMOVED MATERIALS FROM THE SITE UNLESS OTHERWISE NOTED. 3.SEE SHEET C101 FOR ESC NOTES. 4.OVERHEAD POWER LINES EXIST IN THE PROJECT AREA. CONTRACTOR TO EXERCISE CAUTION WHEN WORKING UNDERNEATH THEM. DEMOLITION, CLEARING, & TESC LEGEND SEE NOTES ON SHEET C100 UNLESS OTHERWISE NOTED BELOW. PROPERTY LINE STRAW WATTLES PER COR STD. PLAN 213.40 SAWCUT LOCATION ASPHALT PAVING TO BE REMOVED, SAWCUT EDGES AS REQ'D (NOTE: PROTECT EX PAVING THAT IS TO REMAIN) SITE PREPARATION PLAN C101 2 240 245 250 255 260 265 270 240 245 250 255 260 265 270 10+10 10+20 10+30 10+40 10+50 10+60 10+70 10+80 10+90 11+00 11+10 11+20 11+30 11+40 11+50 11+60 SD C B # 1 21 LF 12" DI SD @ 9.60% EXISTING 8" SEWER EXISTING CINDERBLOCK LEVEL SPREADERS TO REMAIN EXISTING GRADE 6 25 LF 12" SD @ 3.11% SD C B # 1 B INV OUT:254.15 12" INV IN:254.15 12" N: 180505.34 E: 1296829.28 RIM:256.90 SDCB #11 2 2 32 3 5 RIGHT OF WAY 6 7 N: 180460.8664 E: 1296832.699 N: 180671.8504 E: 1296828.566 7 INV OUT:254.93 12" N: 180530.38 E: 1296827.53 RIM:257.45 SDCB #1B 12" SD 15 STEVENS AVE NW STORM SYSTEM PROJECT 1-800-424-5555 or 811 DEC 2025 SWP-27-4316 DATE UNDERGROUND SERVICE Call 48 Hours Before You Dig 4 PACE CJ CJ JF CJ RECORD DRAWINGS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991DATEAPPRBYREVISION DESCRIPTIONNO. APPROVED FOR CONSTRUCTION BY:DATE: Public Works Department CITY OF RENTON KEY NOTES RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20. FORM ASPHALT BERM AT EDGE OF PAVEMENT PER DETAIL 3, SHEET C103. CHANGE IN EDGE TREATMENT PROFILE. TRANSITION TO EXISTING EDGE OF PAVEMENT SHALL BE ROUND AND SMOOTH WITH NO SHARP EDGES. RELOCATE EXISTING MAILBOXES PER COR STANDARD PLAN H027. CREATE ASPHALT BERM SURROUNDING NEW CATCH BASIN PER DETAIL 2, SHEET C103. TO MINIMIZE DISTURBANCE TO PRIVATE PROPERTY, INSTALLATION OF OVERFLOW STRUCTURE AND DISPERSION SHALL BE DONE USING HAND TOOLS AND MACHINERY THAT CAN ACCESS THE INSTALLATION AREA FROM THE ROADWAY. NO HEAVY CONSTRUCTION EQUIPMENT SHALL BE USED OUTSIDE THE RIGHT OF WAY. OVERFLOW STRUCTURE WITH DISPERSION BOARD SHALL BE FIELD LOCATED TO ALLOW A LEVEL (0%+-0.25% SLOPE) INSTALLATION OF THE DISPERSION NOTCH BOARD. SITE SPECIFIC POTHOLE. 1 2 3 4 5 6 7 STORM DRAINAGE NOTES 1.UNLESS OTHERWISE NOTED, ALL STORM PIPES SHALL BE POLYPROPYLENE PER SP 9-05.24 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 2.CONTRACTOR TO VERIFY LOCATIONS OF NEW CATCH BASINS WITH ENGINEER PRIOR TO CONSTRUCTION. 3.ALL NEW CATCH BASIN RISERS SHALL BE ADJUSTED TO FINISHED GRADE PER CITY OF RENTON STANDARD PLAN 106. 4.CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC AT ALL TIMES DURING CONSTRUCTION. 5.CONTRACTOR TO CLEAR VEGETATION AS NECESSARY TO INSTALL PIPE AND OVERFLOW STRUCTURE WITH DISPERSION BOARD. VEGETATION CLEARING SHALL BE INCIDENTAL TO PIPE AND STRUCTURE INSTALLATION. UTILITY LEGEND SEE NOTES ON SHEET C100 FOR GENERAL NOTES EXISTING TYPE 1 CATCH BASIN EXISTING TYPE 2 CATCH BASIN NEW TYPE 1 CATCH BASIN PER COR STANDARD PLAN 200.00 PROPERTY LINE RIGHT OF WAY LINE SANITARY SEWER PIPE STORM DRAIN PIPE WITH FLOW DIRECTION ASPHALT PAVING PATCH PER COR STD PLAN 110.1 THICKENED EDGE ASPHALT TREATMENT PER DETAIL 3, SHEET C103 GRAVEL SHOULDER RESTORATION Feet 0 10 20 IMPROVEMENTS PLAN C102 3 ENLARGEMENT1 C103 1 C1 0 3 OV E R F L O W S T R U C T U R E WI T H D I S P E R S I O N B O A R D (N T S ) 1.50' SUBGRADE MATCH EXISTING GRAVEL OR VEGETATION3" MIN EXISTING ASPHALT ROADWAY 0.50'0.50' MIN SOIL BENCH (TYP) 0. 5 0 ' 1. 0 0 ' (M I N ) 3. 5 8 ' 1.00' MIN (TYP) 2" X 12" NOTCHED GRADE BOARD, 2"X2" NOTCHES, 18" O.C. TO BE INSTALLED AT 0% SLOPE PER COR STD PLAN 224.00. PERMEABLE BALLAST PER SPECIFICATION 9-03.9(2) (TYP) GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER SPECIFICATION 9-03.12(3) NON-WOVEN GEOTEXTILE FABRIC FOR SEPARATION PER SPECIFICATION 9-33.1. MIRAFI 160N OR APPROVED ALTERNATIVE. 3' X 36" PVC SDR 35 PIPE SECTION 12" INSERTA-TEE OR APPROVED CONNECTOR IE: 252.17 12" 0. 5 0 ' (T Y P ) 4" X 4" SUPPORT POST WRAP SIDES WITH GEOTEXTILE (TYP) 18 " M I N PREPARE EXISTING ASPHALT ROAD SURFACE PER SPECIFICATION 5-04.3(4) ASPHALT THICKENED EDGE 4"2" MIN 4" X 30" RECTANGULAR CUTOUT IN PIPE.GASKETED END CAP OF SAME MATERIAL 8"MI N INV IN:252.17 12" 36" PVC STANDPIPE FIELD LOCATE TO MAINTAIN FLAT SLOPE ACROSS NOTCH BOARD AND MINIMIZE GROUND DISTURBANCE OVERFLOW STRUCTURE WITH DISPERSION BOARD 8.33' 4. 5 0 ' 1.50' (TYP) 1 C302 1 C1 0 3 DEPRESS CATCH BASIN 1" AND GRADE SURROUNDING ASPHALT TO DRAIN STEVENS AVE NW STORM SYSTEM PROJECT 1-800-424-5555 or 811 DEC 2025 SWP-27-4316 DATE UNDERGROUND SERVICE Call 48 Hours Before You Dig 4 PACE CJ CJ JF CJ RECORD DRAWINGS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991DATEAPPRBYREVISION DESCRIPTIONNO. APPROVED FOR CONSTRUCTION BY:DATE: Public Works Department CITY OF RENTON DETAILS C103 4 1 NOT TO SCALE OVERFLOW STRUCTURE WITH DISPERSION BOARD PLAN AND PROFILE 3 NOT TO SCALE RAISED ASPHALT SHOULDER FOR FLOW DIVERSION 2 SCALE: 1" = 2' RAISED ASPHALT BERM AT CATCH BASIN Feet 0 2 4 Feet 0 2 4