Loading...
HomeMy WebLinkAboutR-431603270 270 z n m r-I � U 265 265 LU °° O `t U m z u O 260 N 260 �w a ON J U- C) _ - - = = Cn TP\ W 255 p z EXISTING GRADE 255 25 TLF 12" SD o @ 3.11/ \ \ EXISTING CINDERBLOCK LEVEL 250 \ \ SPREADERS TO REMAIN 250 21 LF 12" DI SD @9.60% \\\\\ \ \ 6 \ \ 245 \ \\ 245 EXISTING 8" SEWER \ 240 \ \ \ 240 Ln N O rn rn CO co ro � � r rn r r n Ln r< Ln � Ln c6 Ln � Ln Ln �i Ln Ln of cd : 'V- N r} O tl ad N N N N N N N N N N N N N N N N 10 10 10 20 10 30 10 40 10 50 10 60 10 70 10 80 10 90 11 00 11 10 11 20 11 30 11 40 11 50 11 60 CP# 10 N=180641.62 E=1296811.77 ELEV.=259.21 6"DEC - ---__ 8"DEC 1 d"nrr, `---� --— — — — — — — — — �6e� / °' ------------- _ /alb 6v ?.6b- CONC \ \ DWY \�\ \CONIC \\ ,_�69-_-,-- �76- _ _ ��\ ��_ \� DWY \ -272 �r-R,*-_ NO. REVISION DESCRIPTION BY I DATE I APPR CONIC DWY SURVEYED: SCALE: PACE DESIGNED: CJ DRAWN: ONE INCH AT FULL SCALE IF ci NOT ONE INCH SCALE ACCORDINGLY CHECKED: JF DATUM: PROJMGR: VERTICAL: NAVD 1988 Ci HORIZONTAL: NAD 1983/1991 12- CONIC BLOCK WALL I N I 10' EASEMENT '14 \\ PER V.O. 2223 \ -_� �°EC� \\ \ (3)6"DEC d 10"DEC \ I 6-DEC 4 - - "DEC vv CLUSTER _-- ___ `\ 6"DEC _ 6"DEC_ � - - - \��� I I ------- (2)8"DEC -- —---- ------------- 0. `--------343---- THICK --Skl-_------- TL CHRI Jor-•- o ry ry ry ry ry� - - - 245-- - '. I ry • I- I- h h V' CONC �� BLOCK WALL 24 DEC__-- \ T-NLARGEMENT --__ 6"DEC 50--I \ / / 4 54-- -\\ �S � I - 52-- - �24"SNAG /- I 6- �� - --- 3.- -\ \ -252 8"CON Ill:IWAZO.8654_ JE 12-92.699 \\ CON 10.CITY OF RENTON Public Works Department APPROVED FOR CONSTRUCTION BY: DATE: RECORD DRAWINGS STORM DRAINAGE NOTES 1. UNLESS OTHERWISE NOTED, ALL STORM PIPES SHALL BE POLYPROPYLENE PER SP 9-05.24 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 2. CONTRACTOR TO VERIFY LOCATIONS OF NEW CATCH BASINS WITH ENGINEER PRIOR TO CONSTRUCTION. 3. ALL NEW CATCH BASIN RISERS SHALL BE ADJUSTED TO FINISHED GRADE PER CITY OF RENTON STANDARD PLAN 106. 4. CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC AT ALL TIMES DURING CONSTRUCTION. 5. CONTRACTOR TO CLEAR VEGETATION AS NECESSARY TO INSTALL PIPE AND OVERFLOW STRUCTURE WITH DISPERSION BOARD. VEGETATION CLEARING SHALL BE INCIDENTAL TO PIPE AND STRUCTURE INSTALLATION. UTILITY LEGEND SEE NOTES ON SHEET C100 FOR GENERAL NOTES EXISTING TYPE 1 CATCH BASIN PROPERTY LINE O RIGHT OF WAY LINE EXISTING TYPE 2 CATCH BASIN SS a NEW TYPE 1 CATCH BASIN PER COR STANDARD PLAN 200.00 KEY NOTES SANITARY SEWER PIPE STORM DRAIN PIPE WITH FLOW DIRECTION ASPHALT PAVING PATCH PER COR STD PLAN 110.1 THICKENED EDGE ASPHALT TREATMENT PER DETAIL 3, SHEET C103 GRAVEL SHOULDER RESTORATION ❑1 RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20. �2 FORM ASPHALT BERM AT EDGE OF PAVEMENT PER DETAIL 3, SHEET C103. 131 CHANGE IN EDGE TREATMENT PROFILE. TRANSITION TO EXISTING EDGE OF PAVEMENT SHALL BE ROUND AND SMOOTH WITH NO SHARP EDGES. ❑4 RELOCATE EXISTING MAILBOXES PER COR STANDARD PLAN H027. CREATE ASPHALT BERM SURROUNDING NEW CATCH BASIN PER DETAIL 2, SHEET C103. TO MINIMIZE DISTURBANCE TO PRIVATE PROPERTY, INSTALLATION OF OVERFLOW STRUCTURE AND DISPERSION SHALL BE DONE USING HAND TOOLS AND MACHINERY THAT CAN ACCESS THE INSTALLATION AREA FROM THE ROADWAY. NO HEAVY CONSTRUCTION EQUIPMENT SHALL BE USED OUTSIDE THE RIGHT OF WAY. OVERFLOW STRUCTURE WITH DISPERSION BOARD SHALL BE FIELD LOCATED TO ALLOW A LEVEL (0%+-0.25% SLOPE) INSTALLATION OF THE DISPERSION NOTCH BOARD. E SITE SPECIFIC POTHOLE. 0 10 -- R-431603 STEVENS AVE NW STORM SYSTEM PROJECT IMPROVEMENTS PLAN Call 48 Hours Before You Dig 1-800-424-5555 or 811 UNDERGROUND SERVICE COR PROJECT NO: SW P-27-4316 DATE DEC 2025 DRAWING NO: C102 SHEET NO: OF: 3 4