HomeMy WebLinkAboutzR-4316setSTEVENS AVE NW
STORM SYSTEM PROJECT
Ell
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND
FEDERAL LAWS. SEE THE "STANDARD DETAILS" SECTION OF THE PROJECT SPECIFICATIONS FOR
REFERENCED CITY OF RENTON (COR) STANDARD DETAILS AND ANY REFERENCED
WASHINGTON STATE DEPARTMENT OF TRANSPORTATION (WSDOT) STANDARD DETAILS. ALL
WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS
AND THE CONTRACT SPECIAL PROVISIONS
2. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE CITY ENGINEER OR DESIGNATED
REPRESENTATIVE.
GENERAL ESC NOTES
1. THE TEMPORARY EROSION AND SEDIMENT CONTROL (TESC) PLAN OUTLINED HEREIN IS CONCEPTUAL. THE
CONTRACTOR IS REQUIRED TO SUBMIT A FINAL TEMPORARY WATER POLLUTION AND EROSION CONTROL PLAN IN
ACCORDANCE WITH SPECIAL PROVISIONS SECTION 1-07.15.
2. THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND
UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/ESC SUPERVISOR UNTIL ALL
CONSTRUCTION IS APPROVED.
3. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL
CLEARING AND GRADING SO AS TO ENSURE THAT THE TRANSPORT OF SEDIMENT TO SURFACE WATERS, DRAINAGE
SYSTEMS, AND ADJACENT PROPERTIES IS MINIMIZED.
4. THE ESC FACILITIES SHOWN ON THESE PLANS OR SPECIFIED HEREIN ARE THE MINIMUM REQUIREMENTS FOR
ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED
AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT FOR CHANGING SITE CONDITIONS
(E.G., ADDITIONAL SUMP PUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.).
5. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/ESC SUPERVISOR AND MAINTAINED TO ENSURE
CONTINUED PROPER FUNCTIONING. WRITTEN RECORDS SHALL BE KEPT OF WEEKLY REVIEWS OF THE ESC FACILITIES
DURING THE WET SEASON (OCT. 1 TO APRIL 30) AND OF MONTHLY REVIEWS DURING THE DRY SEASON (MAY 1 TO
SEPT. 30).
3. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH THE CITY
6.
ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO
Z
N W
ENGINEER FOR A PRECONSTRUCTION CONFERENCE.
DAYS DURING THE WET SEASON OR SEVEN DAYS DURING THE DRY SEASON SHALL BE IMMEDIATELY STABILIZED
_
Lu
WITH THE APPROVED ESC METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.).
W o -
4. A COPY OF THESE APPROVED PLANS AND PROJECT SPECIFICATIONS MUST BE ON THE SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
7.
ANY AREA NEEDING ESC MEASURES NOT REQUIRING IMMEDIATE ATTENTION SHALL BE ADDRESSED WITHIN
KING COUNTY
m
FIFTEEN (15) DAYS.
(CITY OF RENTON
f i
5. THE CITY OF RENTON ASSUMES NO LIABILITY FOR THE ACCURACY OF THE RECORD
INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES WITHIN PROPOSED
a�!
m
8.
THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR
N
EXCAVATION LIMITS. CONTACT UNDERGROUND UTILITY LOCATE SERVICE (1-800-454-5555) A
WITHIN FORTY-EIGHT (48) HOURS FOLLOWING A STORM EVENT.
-
MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION TO OBTAIN ON -SITE UTILITY LOCATIONS.
--
P R 0 J E C T
CONTRACTOR SHALL POTHOLE ALL UNDERGROUND GAS, WATER, SERVICE CONNECTIONS,
g
AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH
_
AVE s_
AND ALL OTHER UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION AND
BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING
LOCATION RENjON ,�_ �-
NOTIFY THE ENGINEER OF ANY CONFLICTS. PRECAUTIONS AND REMEDIAL MEASURES SHALL
OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
BE TAKEN AS REQUIRED TO PROTECT PERSONS AND PROPERTY AND TO AVOID DISRUPTION
-
OF SERVICE. UNLESS OTHERWISE NOTED, PROTECT ALL UTILITIES FROM DAMAGE WHICH
10.
WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM
SHALL INCLUDE PROVIDING TEMPORARY SUPPORT SYSTEMS AND SHORING AROUND
THICKNESS OF 2 TO 3 INCHES.
-
UTILITIES DURING EXCAVATION, IF AN EXISTING PRIVATE UTILITY CONFLICTS WITH PROPOSED
IMPROVEMENTS COORDINATE THE RELOCATION OF THE PRIVATE UTILITY WITH THE UTILITY
11.
PUBLIC STREETS SHALL BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE CITY. FLUSHING OF STREETS WITH
,.,,. ,,: ;,,LY,,� •
OWNER UNLESS NOTED OTHERWISE OR DIRECTED BY THE ENGINEER.
WATER WILL NOT BE ALLOWED.
VICINITY MAP
NOT TO SCALE
HORIZONTAL DATUM
HORIZONTAL DATUM: CITY OF RENTON. BASED ON GPS MEASUREMENTS UTILIZING THE VIRTUAL
REFERENCE NETWORK AND CONSTRAINED TO THE FOLLOWING CONTROL POINT:
DESIGNATION: 1899
MONUMENT ID: PUNCH IN 2" BRASS DISK IN CONC MON IN CASE (DN-0.60')
NORTH= 182,072.63
EAST= 1,297,108.45
VERTICAL DATUM
VERTICAL DATUM: NAVD 88 BASED ON GPS MEASUREMENTS UTILIZING THE VIRTUAL REFERENCE
Q NETWORK AND CONSTRAINED TO THE FOLLOWING VERTICAL BENCHMARK:
b DESIGNATION: BM 106
MONUMENT ID: RAILROAD SPIKE (0.30' B.G.)
ELEVATION = 203.92 FEET
THE LOCATION AND DESCRIPTION OF ALL SURVEY MARKERS SHOWN HEREON ARE BASED ON
FIELD OBSERVATIONS TAKEN IN JANUARY, 2025, UNLESS OTHERWISE INDICATED.
WORK PERFORMED IN CONJUNCTION WITH THIS SURVEY UTILIZED THE FOLLOWING EQUIPMENT
> AND PROCEDURES: (A) 1" TRIMBLE S7 SERIES ELECTRONIC TOTAL STATION, MAINTAINED TO THE
Q MANUFACTURER'S SPECIFICATIONS PER W.A.C. 332-130-100. (B) FIELD TRAVERSE, EXCEEDING
REQUIREMENTS SET FORTH IN W.A.C. 332-130-090.
(C) LEAST SQUARES ADJUSTMENT USING StarNet VERSION 9.0 EXCEEDING REQUIREMENTS PER
n W.A.C. 332-130-080.
THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE REPORT AND DOES NOT
PURPORT TO SHOW ALL EASEMENTS.
i
THIS TOPOGRAPHIC SURVEY DRAWING ACCURATELY REPRESENTS SURFACE FEATURES LOCATED
DURING THE COURSE OF THIS SURVEY. UNDERGROUND UTILITIES SHOWN HEREON ARE BASED
/ SOLELY UPON INFORMATION PROVIDED BY OTHERS AND PACE ENGINEERS, INC. DOES NOT
z ACCEPT RESPONSIBILITY OR ASSUME LIABILITY FOR THEIR ACCURACY OR COMPLETENESS.
Q
CONTRACTOR/ENGINEERS SHALL VERIFY EXACT SIZE AND LOCATION PRIOR TO CONSTRUCTION.
CALL FOR LOCATE: UTILITY LOCATION SERVICE: 811
Sp
i
i
n
/
C
1
S
�i
Q
z
J
NO. REVISION DESCRIPTION
Sheet List Table
Sheet Number
Sheet Title
C100
COVER
C101
SITE PREPERATION PLAN
C102
IMPROVEMENTS PLAN
C103
DETAILS
BY I DATE I APPR
6. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF TRAFFIC CONTROL PLANS.
CONTRACTOR SHALL SUBMIT PLANS TO ENGINEER FOR REVIEW AND APPROVAL AT LEAST 10
WORKING DAYS PRIOR TO IMPLEMENTATION.
7. EXISTING WATERLINE BEND AND BLOCKING ARE NOT SHOWN.
8. STORM SEWER LENGTHS ARE MEASURED BETWEEN CENTERS OF MANHOLES AND CATCH
BASINS UNLESS OTHERWISE NOTED.
9. EXCEPT AS OTHERWISE NOTED, CATCH BASIN AND MANHOLE RIM ELEVATIONS GIVEN ARE
APPROXIMATE. FINAL ELEVATIONS SHALL MATCH FINAL GRADE.
10. SITE CONSTRUCTION LIMITS (PRESERVATION LINES) COINCIDE WITH CITY RIGHT-OF-WAY AND
UTILITY EASEMENTS UNLESS SHOWN OTHERWISE.
11. FOR CLARITY OF DRAWINGS, OVERHEAD POWER AND TELECOM ARE NOT SHOWN ON THE
DRAWINGS. CONTRACTOR IS ADVISED THAT THERE ARE OVERHEAD POWER AND TELECOM
THROUGHOUT PROJECT AREA, INCLUDING DIRECTLY OVER PROPOSED PIPE IMPROVEMENTS.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM THE WORK IN A SAFE MANNER AND IN
ACCORDANCE WITH ANY REQUIREMENTS SET FORTH BY THE UTILITY OWNER AND
APPLICABLE LAWS AND REGULATIONS.
12. NO STAGING AREA IS PROVIDED TO THE CONTRACTOR. ALL STAGING AREAS SHALL BE ON A
CONTRACTOR SECURED AREA. ALL TESC REQUIREMENTS APPLY TO THE CONTRACTOR'S
OBTAINED STAGING AREA.
13. CONTRACTOR SHALL COORDINATE WITH CITY OF RENTON WATER UTILITY ABOUT ANY
RELOCATION OR MODIFICATION TO SERVICE LINES. TEMPORARY WATER SERVICE RELOCATION
INCLUDES SERVICE LINE AND CONNECTION FITTINGS AND SHALL BE INCIDENTAL TO OTHER
PAYMENT ITEMS.
14. ALL STORM DRAINAGE PIPES SHALL HAVE WATERTIGHT JOINTS PER MANUFACTURER
RECOMMENDATION.
15. CONTRACTOR SHALL REPLACE ANY SURVEY MONUMENTS DISTURBED IN ACCORDANCE WITH
SECTION 1-05.4 OF THE SPECIAL PROVISIONS AND CITY OF RENTON SURVEY STANDARDS AT
NO ADDITIONAL COST TO THE CITY OF RENTON.
SURVEYED:
SCALE:
PACE
DESIGNED:
CJ
ONE INCH
DRAWN:
ci
AT FULL SCALE IF
NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
JF
DATUM:
VERTICAL: NAVD 1988
PROJMGR:
Ci
HORIZONTAL: NAD 1983/1991
CITY OF RENTON
Public Works Department
APPROVED FOR CONSTRUCTION
BY: DATE:
12. IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY REQUIREMENTS, WASTEWATER FROM CEMENT CONCRETE
MASONRY, OR ASPHALT CONCRETE CUTTING, OR POURING OPERATIONS SHALL NOT BE DISCHARGED INTO STORM
DRAINAGE SYSTEMS OR SURFACE WATERS. IMPERVIOUS SURFACES CONTAMINATED WITH SEDIMENT FROM GRIT
AND CUTTING, PLANING OR PULVERIZING OPERATIONS SHALL BE VACUUM -CLEANED TO PREVENT CONTAMINANTS
FROM ENTERING THE STORM DRAINAGE SYSTEM OR SURFACE WATERS.
13. CATCH BASIN INSERTS SHALL BE PLACED AT ALL CATCH BASINS ALONG PIPE ALIGNMENT. SEE CITY OF RENTON
STANDARD PLAN 216.30.
14. INSTALL SILT FENCING AROUND ENTIRE STAGING/STOCKPILE AREAS PER COR STANDARD PLAN 214.
15. TEMPORARY SEDIMENTATION TANK MAYBE REQUIRED IN CONTRACTOR STAGING AREA IF THE SILT FENCING IS
NOT ADEQUATE.
16. KEEP PUBLIC AND PRIVATE ROADWAYS/PARKING LOTS, SIDEWALKS, AND TRAILS FREE OF DEBRIS AND SEDIMENT.
17. CONSTRUCT TEMPORARY STORMWATER BYPASSES AS NEEDED DURING CONSTRUCTION TO DIVERT STORMWATER
AROUND TRENCHING AND PIPE INSTALLATION ACTIVITIES AND MAINTAIN DRAINAGE OF UPSTREAM
STORMWATER. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF STORM DRAIN BYPASS PLAN. UNLESS OTHERWISE
NOTED, BYPASSES ARE TO BE DESIGNED TO HANDLE THE VOLUME AND PEAK FLOWS OF THE 2-YEAR STORM EVENT
AT A MINIMUM. SUBMIT AS PART OF WATER CONTROL PLAN. STORM DRAIN BYPASS PLAN SHALL ALSO ADDRESS
THE DOWNSTREAM SYSTEM AND PREVENTION OF STORMWATER ENTERING THE WORK AREA BY BACKING UP
FROM DOWNSTREAM.
18. ALL DEWATERING WATER AND RUNOFF WITHIN CONSTRUCTION AREAS SHALL BE TREATED VIA SEDIMENTATION,
FILTRATION THROUGH VEGETATION IN APPROVED AREAS, OR PORTABLE FILTRATION SYSTEMS (UTILIZING TANKS
AND FILTERS), AS NEEDED, PRIOR TO DISCHARGE TO DOWNSTREAM SYSTEM IN ORDER TO MEET ALL APPLICABLE
LOCAL, STATE AND FEDERAL WATER QUALITY REGULATIONS. CONTRACTOR MAY ALSO DISCHARGE TO THE
SANITARY SEWER SYSTEM AFTER OBTAINING APPLICABLE PERMITS AND MEETING PRETREATMENT REQUIREMENTS.
Call 48 Hours
Before You Dig
1-800-424-5555 or 811
R-431601 UNDERGROUND SERVICE
COR PROJECT NO:
SW P-27-4316
STEVENS AVE NW STORM SYSTEM PROJECT DATE
RECORD DEC2025
DRAWINGSDRAWING NO:
COVER C100
SHEET NO: OF:
1 4
i
N
i
z
186
'AHAM
VE NW
6"DEC
CP# 10
N=180641.62
E=1296811.77
ELEV.=259.21
T --_—_
1 d"nrr, ---�
- — — — — — — — — — — —
—
/ 0� / ONE
CONC \ \
DWY CONIC
�7A— _ _ ��\\ �__- \� DWY \
— _ -272-
�r-R,*-_
NO.
REVISION DESCRIPTION
BY DATE APPR
TL 4204400193
CINDY WU
312 STEVENS AVE NW
CP# 9
685E-49.9 MAG
N=180561.74
E=1296824.50
0cocoo
ri
� coo
co a 00 II
a W II II
U H Z W
A
12" CONC
BLOCK WALL.—
10' EASEMENT
1\\\ v PER V.O. 2223
6"DEC I
V.O. 2223 CP# 8 \\ \\ I (3)6"DEC \
(S 130TH ST) 685B-49.8 R/C \ \ \\
\
N=180510.38
E=1296913.132"CON — — — —
ELEV.=239.36
4 10"DEC --_—__
\ I 6"DEC
_ 4"DEC
\ I----
\ CLUSTER
GARAGE k\ I _
COMPOST —
---246— —
BIN I �. I — 6"DEC
\\— _--0 DEC — --- —----------
\ I 0—
(2)8-DEC
6"DEC ��-- ---{----------------------
N I
14"SNAG �ry-244— — ryeY— — — THICK
--SSW--------- TL
—245— —
CONC
N �• BLOCK WALL
------ --_ 24"DEC_—
\
— — 6"DEC
/ 5+- — �S
/ ''14"CON
8"CON ��------'� 41. I
-- --- 52-- —\ \
\ /.124"SNAG --��,
8"CON'r�--------�54 ----
CONIC
DWY
SURVEYED: SCALE:
PACE
DESIGNED:
CJ
DRAWN: ONE INCH
AT FULL SCALE IF
CJ NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
JF DATUM:
PROJMGR: VERTICAL: NAVD 1988
CJ HORIZONTAL: NAD 1983/1991
CITY OF RENTON
Public Works Department
APPROVED FOR CONSTRUCTION
BY: DATE:
_— — — — — — — — — - —
\
RECORD
DRAWINGS
DEMOLITION NOTES
1. THE WORK UNDER THE CONTRACT INCLUDES ALL CLEARING NECESSARY TO COMPLETE ALL
WORK ASSOCIATED WITH THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY
REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT
WORK. CLEARING, GRUBBING, AND DEMOLITION WORK SHALL BE INCIDENTAL TO THE PROJECT.
2. CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED AND REMOVED MATERIALS FROM
THE SITE UNLESS OTHERWISE NOTED.
3. SEE SHEET C101 FOR ESC NOTES.
4. OVERHEAD POWER LINES EXIST IN THE PROJECT AREA. CONTRACTOR TO EXERCISE CAUTION
WHEN WORKING UNDERNEATH THEM.
DEMOLITION, CLEARING, & TESC LEGEND
SEE NOTES ON SHEET C100 UNLESS OTHERWISE NOTED BELOW.
PROPERTY LINE
STRAW WATTLES PER COR STD. PLAN 213.40
SAWCUT LOCATION
ASPHALT PAVING TO BE REMOVED, SAWCUT EDGES AS REQ'D
(NOTE: PROTECT EX PAVING THAT IS TO REMAIN)
DEMOLITION KEY NOTES
❑1 PRESERVE AND PROTECT EXISTING UTILITY.
�2 PRESERVE AND PROTECT EXISTING TREE.
�3 PRESERVE AND PROTECT EXISTING MAILBOXES.
❑4 PRESERVE AND PROTECT EXISTING BLOCK WALL.
0 10 --
R-431602
STEVENS AVE NW STORM SYSTEM PROJECT
SITE PREPARATION PLAN
Call 48 Hours
Before You Dig
1-800-424-5555 or 811
UNDERGROUND SERVICE
COR PROJECT NO:
SW P-27-4316
DATE
DEC 2025
DRAWING NO:
C101
SHEET NO: OF:
2 4
270
270
z
n
m
r-I �
U
265
265
LU
°°
O
`t
U
m
z
u
O
260
N
260
�w
a
ON
J
U-
C)
_
-
-
=
= Cn
TP\
W
255
p
z
EXISTING
GRADE
255
25 TLF 12" SD
o
@ 3.11/
\
\
EXISTING
CINDERBLOCK
LEVEL
250
\ \
SPREADERS
TO REMAIN
250
21
LF 12" DI SD
@9.60%
\\\\\
\
\
6
\
\
245
\ \\
245
EXISTING
8" SEWER
\
240
\ \
\
240
Ln
N
O
rn
rn
CO
co
ro
�
�
r
rn
r
r
n
Ln
r<
Ln
�
Ln
c6
Ln
�
Ln
Ln
�i
Ln
Ln
of
cd
:
'V-
N
r}
O
tl
ad
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
10
10 10
20 10
30 10
40 10
50 10
60 10
70 10
80 10
90 11
00 11
10 11
20 11
30 11
40 11
50 11
60
CP# 10
N=180641.62
E=1296811.77
ELEV.=259.21
6"DEC
- ---__ 8"DEC
1 d"nrr, `---�
--— — — — — — — — — �6e� / °'
------------- _ /alb
6v
?.6b- CONC \ \
DWY \�\ \CONIC \\
,_�69-_-,-- �76- _ _ ��\ ��_ \� DWY \
-272
�r-R,*-_
NO.
REVISION DESCRIPTION
BY I DATE I APPR
CONIC
DWY
SURVEYED: SCALE:
PACE
DESIGNED:
CJ
DRAWN: ONE INCH
AT FULL SCALE IF
ci NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
JF DATUM:
PROJMGR: VERTICAL: NAVD 1988
Ci HORIZONTAL: NAD 1983/1991
12- CONIC
BLOCK WALL
I N I
10' EASEMENT
'14 \\ PER V.O. 2223
\ -_� �°EC�
\\ \ (3)6"DEC
d 10"DEC
\ I 6-DEC
4 - -
"DEC vv
CLUSTER _--
___
`\
6"DEC
_ 6"DEC_ � - - -
\��� I I -------
(2)8"DEC
-- —---- -------------
0.
`--------343----
THICK
--Skl-_------- TL
CHRI
Jor-•- o
ry ry ry ry ry�
- - - 245--
-
'. I ry • I- I-
h h V' CONC
�� BLOCK WALL 24 DEC__--
\
T-NLARGEMENT --__
6"DEC
50--I \
/ / 4 54-- -\\ �S
� I - 52-- -
�24"SNAG /- I 6-
�� - --- 3.- -\ \ -252
8"CON
Ill:IWAZO.8654_
JE 12-92.699
\\ CON
10.CITY OF RENTON
Public Works Department
APPROVED FOR CONSTRUCTION
BY: DATE:
RECORD
DRAWINGS
STORM DRAINAGE NOTES
1. UNLESS OTHERWISE NOTED, ALL STORM PIPES SHALL BE POLYPROPYLENE PER
SP 9-05.24 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S REQUIREMENTS.
2. CONTRACTOR TO VERIFY LOCATIONS OF NEW CATCH BASINS WITH ENGINEER
PRIOR TO CONSTRUCTION.
3. ALL NEW CATCH BASIN RISERS SHALL BE ADJUSTED TO FINISHED GRADE PER
CITY OF RENTON STANDARD PLAN 106.
4. CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC AT ALL TIMES DURING
CONSTRUCTION.
5. CONTRACTOR TO CLEAR VEGETATION AS NECESSARY TO INSTALL PIPE AND
OVERFLOW STRUCTURE WITH DISPERSION BOARD. VEGETATION CLEARING
SHALL BE INCIDENTAL TO PIPE AND STRUCTURE INSTALLATION.
UTILITY LEGEND
SEE NOTES ON SHEET C100 FOR GENERAL NOTES
EXISTING TYPE 1 CATCH BASIN
PROPERTY LINE
O RIGHT OF WAY LINE
EXISTING TYPE 2 CATCH BASIN
SS
a NEW TYPE 1 CATCH BASIN PER
COR STANDARD PLAN 200.00
KEY NOTES
SANITARY SEWER PIPE
STORM DRAIN PIPE WITH
FLOW DIRECTION
ASPHALT PAVING PATCH PER COR
STD PLAN 110.1
THICKENED EDGE ASPHALT TREATMENT
PER DETAIL 3, SHEET C103
GRAVEL SHOULDER RESTORATION
❑1 RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20.
�2 FORM ASPHALT BERM AT EDGE OF PAVEMENT PER DETAIL 3, SHEET C103.
131 CHANGE IN EDGE TREATMENT PROFILE. TRANSITION TO EXISTING EDGE OF
PAVEMENT SHALL BE ROUND AND SMOOTH WITH NO SHARP EDGES.
❑4 RELOCATE EXISTING MAILBOXES PER COR STANDARD PLAN H027.
CREATE ASPHALT BERM SURROUNDING NEW CATCH BASIN PER DETAIL 2,
SHEET C103.
TO MINIMIZE DISTURBANCE TO PRIVATE PROPERTY, INSTALLATION OF
OVERFLOW STRUCTURE AND DISPERSION SHALL BE DONE USING HAND
TOOLS AND MACHINERY THAT CAN ACCESS THE INSTALLATION AREA FROM
THE ROADWAY. NO HEAVY CONSTRUCTION EQUIPMENT SHALL BE USED
OUTSIDE THE RIGHT OF WAY. OVERFLOW STRUCTURE WITH DISPERSION
BOARD SHALL BE FIELD LOCATED TO ALLOW A LEVEL (0%+-0.25% SLOPE)
INSTALLATION OF THE DISPERSION NOTCH BOARD.
E SITE SPECIFIC POTHOLE.
0 10 --
R-431603
STEVENS AVE NW STORM SYSTEM PROJECT
IMPROVEMENTS PLAN
Call 48 Hours
Before You Dig
1-800-424-5555 or 811
UNDERGROUND SERVICE
COR PROJECT NO:
SW P-27-4316
DATE
DEC 2025
DRAWING NO:
C102
SHEET NO: OF:
3 4
z
GASKETED END CAP OF SAME MATERIAL
1.00' MIN (TYP)
PERMEABLE BALLAST PER
SPECIFICATION 9-03.9(2) (TYP)
GRAVEL BACKFILL FOR PIPE ZONE
BEDDING PER SPECIFICATION 9-03.12(3)
4" X 30" RECTANGULAR CUTOUT IN PIPE.
2" X 12" NOTCHED GRADE BOARD, 2"X2"
NOTCHES, 18" O.C. TO BE INSTALLED AT 0% SLOPE
PER COR STD PLAN 224.00.
0.50' MIN SOIL BENCH (TYP)
WRAP SIDES WITH GEOTEXTILE (TYP)
4" X 4" SUPPORT POST
NON -WOVEN GEOTEXTILE FABRIC FOR
SEPARATION PER SPECIFICATION 9-33.1.
MIRAFI 160N OR APPROVED ALTERNATIVE.
OVERFLOW STRUCTURE WITH DISPERSION BOARD PLAN AND PROFILE
NOT TO SCALE
NO. I REVISION DESCRIPTION
BY I DATE I APPR
SURVEYED: SCALE:
PACE
DESIGNED:
CJ
DRAWN: ONE INCH
AT FULL SCALE IF
ci NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
JF DATUM:
PROJMGR: VERTICAL: NAVD 1988
Ci HORIZONTAL: NAD 1983/1991
CITY OF RENTON
Public Works Department
APPROVED FOR CONSTRUCTION
DATE:
RAISED ASPHALT BERM AT CATCH BASIN
SCALE: 1" = 2'
rV 1CTI KI/- A r n 11 A I T n!'l A 1'l\AI A
= ��
J IJ UV I\PYVL
MATCH EXISTING GRAVEL
OR VEGETATION
RAISED ASPHALT SHOULDER FOR FLOW DIVERSION
NOT TO SCALE Call 48 Hours
Before You Dig
1-800-424-5555 or 811
R-431604 UNDERGROUND SERVICE
COR PROJECT NO:
SW P-27-4316
STEVENS AVE NW STORM SYSTEM PROJECT DATE
RECORD DEC2025
DRAWINGSDRAWING NO:
DETAILS C 103
SHEET NO: OF:
4 4