Loading...
HomeMy WebLinkAboutAB-4030 part 2COVER Sheet Index Sheet Number Drawing Number Sheet Title 1 COVER 2023 STORM REPAIR PROJECT COVER 2 A ABERDEEN AVE NE STORM IMPROVEMENT PROJECT COVER SHEET 3 B ABERDEEN AVE NE STORM IMPROVEMENT PROJECT SITE PREP PLAN 2023 STORM REPAIR/REPLACEMENT PROJECT VICINITY MAP - ABERDEEN AVE NE STORM IMPROVEMENT PROJECT N SW P - 2 7 - 4 0 3 0 H:\ C A D \ _ P R O J E C T S \ S W P \ 2 7 - 4 0 3 0 _ A B E R D E E N \ D W G NE SUN S E T B L V D 5 1 S 26TH ST CULVERT IMPROVEMENT PROJECT 2022 COVER SHEET 6 2 S 26TH ST CULVERT IMPROVEMENT PROJECT 2022 ABBREVIATIONS, GENERAL NOTES, LEGEND, AND CITY STANDARD PLAN NOTES 7 3 S 26TH ST CULVERT IMPROVEMENT PROJECT 2022 PLAN AND PROFILE AND DETAILS 4 C ABERDEEN AVE NE STORM IMPROVEMENT PROJECT STORM DRAINAGE PLAN VICINITY MAP - S 26TH ST CULVERT IMPROVEMENT PROJECT 2022 N PROJECT LOCATION PROJECT LOCATION AB E R D E E N A V E N E SU N S E T B L V D N E I - 4 0 5 PROJECT LOCATION BE N S O N R D S S 26TH ST S 2 7 T H P L M I L L A V E S B E N S O N D R S 2023 STORM REPAIR/REPLACEMENT PROJECT NOT TO SCALE NOT TO SCALE MDU H G P (GR3 D O G S U RIHVVLR3DO H 3J L 3 HHU UHJLVWHU H G VWDWH R I <DV-L 3 J WR 3 7/20/2023 COVER SHEET GENERAL NOTES HORIZONTAL DATUM VERTICAL DATUM 1.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS. SEE THE "STANDARD DETAILS" SECTION OF THE PROJECT SPECIFICATIONS FOR REFERENCED CITY OF RENTON (COR) STANDARD DETAILS AND ANY REFERENCED WASHINGTON STATE DEPARTMENT OF TRANSPORTATION (WSDOT) STANDARD DETAILS. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS AND THE CONTRACT SPECIAL PROVISIONS 2.ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE CITY ENGINEER OR DESIGNATED REPRESENTATIVE. 3.PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH THE CITY ENGINEER FOR A PRECONSTRUCTION CONFERENCE. 4.A COPY OF THESE APPROVED PLANS AND PROJECT SPECIFICATIONS MUST BE ON THE SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5.LOCATIONS OF EXISTING UTILITIES ARE APPROXIMATE. LOCATIONS ARE BASED ON A COMBINATION OF ONE OR MORE OF THE FOLLOWING: OBSERVATION OF SURFACE FEATURES, GEOGRAPHIC INFORMATION SYSTEM DATA, PAINT MARKS APPLIED BY AN UNDERGROUND UTILITY LOCATING SERVICE, CCTV, AND RECORD SCHEMATIC DRAWINGS. UTILITIES SHOWN IN THESE DRAWINGS ARE FOR THE PURPOSES OF ASSISTING THE CONTRACTOR WITH LOCATING UTILITIES. THE CITY OF RENTON ASSUMES NO LIABILITY FOR THE ACCURACY OF THE RECORD INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES WITHIN PROPOSED EXCAVATION LIMITS. CONTACT UNDERGROUND UTILITY LOCATE SERVICE (1-800-454-5555) A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION TO OBTAIN ON-SITE UTILITY LOCATIONS. CONTRACTOR SHALL POTHOLE ALL UNDERGROUND GAS, WATER, SERVICE CONNECTIONS, AND ALL OTHER UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY CONFLICTS. PRECAUTIONS AND REMEDIAL MEASURES SHALL BE TAKEN AS REQUIRED TO PROTECT PERSONS AND PROPERTY AND TO AVOID DISRUPTION OF SERVICE. UNLESS OTHERWISE NOTED, PROTECT ALL UTILITIES FROM DAMAGE WHICH SHALL INCLUDE PROVIDING TEMPORARY SUPPORT SYSTEMS AND SHORING AROUND UTILITIES DURING EXCAVATION, IF AN EXISTING PRIVATE UTILITY CONFLICTS WITH PROPOSED IMPROVEMENTS, COORDINATE THE RELOCATION OF THE PRIVATE UTILITY WITH THE UTILITY OWNER UNLESS NOTED OTHERWISE OR DIRECTED BY THE ENGINEER. 6.EXISTING WATER LINE BEND AND BLOCKING ARE NOT SHOWN. 7.STORM SEWER LENGTHS ARE MEASURED BETWEEN CENTERS OF MANHOLES AND CATCH BASINS UNLESS OTHERWISE NOTED. 8.EXCEPT AS OTHERWISE NOTED, CATCH BASIN AND MANHOLE RIM ELEVATIONS GIVEN ARE APPROXIMATE. FINAL ELEVATIONS SHALL MATCH FINAL GRADE. 9.USE CDF FOR BEDDING AND BACKFILLING AROUND EXISTING OR NEW UTILITIES WHERE STANDARD METHODS DO NOT PERMIT COMPACTION REQUIREMENTS TO BE MET, AS SHOW ON THE DRAWINGS, OR AS DIRECTED BY THE ENGINEER. 10.SITE CONSTRUCTION LIMITS (PRESERVATION LINES) COINCIDE WITH CITY RIGHT-OF-WAY UNLESS SHOWN OTHERWISE. 11.FOR CLARITY OF DRAWINGS, OVERHEAD POWER AND TELECOM ARE NOT SHOWN ON THE DRAWINGS. CONTRACTOR IS ADVISED THAT THERE ARE OVERHEAD POWER AND TELECOM THROUGHOUT PROJECT AREA, INCLUDING DIRECTLY OVER PROPOSED PIPE IMPROVEMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM THE WORK IN A SAFE MANNER AND IN ACCORDANCE WITH ANY REQUIREMENTS SET FORTH BY THE UTILITY OWNER AND APPLICABLE LAWS AND REGULATIONS. 12.NO STAGING AREA IS PROVIDED TO THE CONTRACTOR. ALL STAGING AREAS SHALL BE ON A CONTRACTOR SECURED AREA. ALL TESC REQUIREMENTS APPLY TO THE CONTRACTOR'S OBTAINED STAGING AREA. 13.CONTRACTOR SHALL COORDINATE WITH CITY OF RENTON WATER UTILITY ABOUT ANY RELOCATION OR MODIFICATION TO SERVICE LINES. TEMPORARY WATER SERVICE RELOCATION INCLUDES SERVICE LINE AND CONNECTION FITTINGS AND SHALL BE INCIDENTAL TO OTHER PAYMENT ITEMS. 14.THE NEW STORM CROSSES EXISTING UNDERGROUND GAS MAINS AND GAS SERVICES IN MULTIPLE LOCATIONS. IF NOT PREVIOUSLY POTHOLED BY PSE, CONTRACTOR SHALL POTHOLE GAS A MINIMUM OF 10 DAYS IN ADVANCE OF PERFORMING WORK IN THE AREA AND PROVIDE RESULTS TO ENGINEER. IF EXISTING GAS MAIN IS IN CONFLICT WITH NEW STORM, CITY WILL PROVIDE NEW PROFILE GRADES FOR THE STORM PIPING. ADJUSTMENT OF THE STORM ALIGNMENT SHALL BE AT NO ADDITIONAL COST TO THE CITY. IF EXISTING GAS MAIN (OR SERVICE) IS IN CONFLICT WITH NEW STORM AND STORM PROFILE CANNOT BE ADJUSTED, CONTRACTOR SHALL COORDINATE WITH PSE FOR GAS RELOCATION (CONTACT PSE GAS REPRESENTATIVE CHANG PAK AT 253-395-6988). ALL COST FOR COORDINATION WITH PSE FOR GAS SERVICE RELOCATION SHALL BE PAID FOR BY FORCE ACCOUNT. 15.CONTRACTOR SHALL NOT ORDER PRECAST MANHOLES/CATCH BASINS UNTIL ALL POTENTIAL CONFLICTS THAT COULD AFFECT THE MANHOLES/CATCH BASINS HAVE BEEN POTHOLED TO CHECK FOR CONFLICT, AND THOSE CONFLICTS HAVE BEEN RESOLVED. 16.ALL STORM DRAINAGE PIPES SHALL HAVE WATERTIGHT JOINTS PER MANUFACTURER RECOMMENDATION. 17.EXISTING STORM DRAINAGE PIPES SHALL BE ABANDONED AND FILLED WHERE INDICATED ON THE PLANS IN ACCORDANCE WITH SECTION 2-02.3(4) OF THE SPECIAL PROVISIONS FOR PIPES AND SECTION 7-05.3(2) OF THE STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS FOR STRUCTURES. 18.CONTRACTOR SHALL REPLACE ANY SURVEY MONUMENTS DISTURBED IN ACCORDANCE WITH SECTION 1-05.4 OF THE SPECIAL PROVISIONS AND CITY OF RENTON SURVEY STANDARDS AT NO ADDITIONAL COST TO THE CITY OF RENTON. 19.FOR PAVEMENT RESTORATION, CONTRACTOR IS REQUIRED TO PROVIDE A HOT MIX ASPHALT TRENCH PATCH AND OVERLAY IN ACCORDANCE WITH COR STANDARD PLAN 110. 20.WHERE TYPE 2 CATCH BASINS ARE INSTALLED IN ROADWAY GUTTER SECTION THEY SHALL BE PLACED IN ACCORDANCE WITH COR STANDARD PLAN 101.1. WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NAD 83/91 NAVD 88 ABERDEEN AVE NE STORM IMPROVEMENT PROJECTSW P - 2 7 - 4 0 3 0 H:\ C A D \ _ P R O J E C T S \ S W P \ 2 7 - 4 0 3 0 _ A B E R D E E N \ D W G GENERAL ESC NOTES 1.THE TEMPORARY EROSION AND SEDIMENT CONTROL (TESC) PLAN OUTLINED HEREIN IS CONCEPTUAL. THE CONTRACTOR IS REQUIRED TO SUBMIT A FINAL TEMPORARY WATER POLLUTION AND EROSION CONTROL PLAN IN ACCORDANCE WITH SPECIAL PROVISIONS SECTION 1-07.15. 2.THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/ESC SUPERVISOR UNTIL ALL CONSTRUCTION IS APPROVED. 3.THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL CLEARING AND GRADING SO AS TO ENSURE THAT THE TRANSPORT OF SEDIMENT TO SURFACE WATERS, DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES IS MINIMIZED. 4.THE ESC FACILITIES SHOWN ON THESE PLANS OR SPECIFIED HEREIN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT FOR CHANGING SITE CONDITIONS (E.G., ADDITIONAL SUMP PUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.). 5.THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/ESC SUPERVISOR AND MAINTAINED TO ENSURE CONTINUED PROPER FUNCTIONING. WRITTEN RECORDS SHALL BE KEPT OF WEEKLY REVIEWS OF THE ESC FACILITIES DURING THE WET SEASON (OCT. 1 TO APRIL 30) AND OF MONTHLY REVIEWS DURING THE DRY SEASON (MAY 1 TO SEPT. 30). 6.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON OR SEVEN DAYS DURING THE DRY SEASON SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). 7.ANY AREA NEEDING ESC MEASURES NOT REQUIRING IMMEDIATE ATTENTION SHALL BE ADDRESSED WITHIN FIFTEEN (15) DAYS. 8.THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN FORTY-EIGHT (48) HOURS FOLLOWING A STORM EVENT. 9.AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM. 10.WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM THICKNESS OF 2 TO 3 INCHES. 11.NO STOCKPILING/STAGING WILL BE CONDUCTED WITHIN THE RIGHT OF WAY OR CITY OWNED SITE. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ITS OWN STOCKPILE/STAGING AREAS. 12.PUBLIC STREETS SHALL BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE CITY. FLUSHING OF STREETS WITH WATER WILL NOT BE ALLOWED. 13.IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY REQUIREMENTS, WASTEWATER FROM CEMENT CONCRETE MASONRY, OR ASPHALT CONCRETE CUTTING, OR POURING OPERATIONS SHALL NOT BE DISCHARGED INTO STORM DRAINAGE SYSTEMS OR SURFACE WATERS. IMPERVIOUS SURFACES CONTAMINATED WITH SEDIMENT FROM GRIT AND CUTTING, PLANING OR PULVERIZING OPERATIONS SHALL BE VACUUM-CLEANED TO PREVENT CONTAMINANTS FROM ENTERING THE STORM DRAINAGE SYSTEM OR SURFACE WATERS. 14.CATCH BASIN INSERTS SHALL BE PLACED AT ALL CATCH BASINS ALONG PIPE ALIGNMENT. SEE CITY OF RENTON STANDARD PLAN 216.30. 15.INSTALL SILT FENCING AROUND ENTIRE STAGING/STOCKPILE AREAS PER COR STANDARD PLAN 214. 16.TEMPORARY SEDIMENTATION TANK MAY BE REQUIRED IN CONTRACTOR STAGING AREA IF THE SILT FENCING IS NOT ADEQUATE. 17.KEEP PUBLIC AND PRIVATE ROADWAYS/PARKING LOTS, SIDEWALKS, AND TRAILS FREE OF DEBRIS AND SEDIMENT. 18.CONSTRUCT TEMPORARY STORMWATER BYPASSES AS NEEDED DURING CONSTRUCTION TO DIVERT STORMWATER AROUND TRENCHING AND PIPE INSTALLATION ACTIVITIES AND MAINTAIN DRAINAGE OF UPSTREAM STORMWATER. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF STORM DRAIN BYPASS PLAN. UNLESS OTHERWISE NOTED, BYPASSES ARE TO BE DESIGNED TO HANDLE THE VOLUME AND PEAK FLOWS OF THE 2-YEAR STORM EVENT AT A MINIMUM. SUBMIT AS PART OF WATER CONTROL PLAN. STORM DRAIN BYPASS PLAN SHALL ALSO ADDRESS THE DOWNSTREAM SYSTEM AND PREVENTION OF STORMWATER ENTERING THE WORK AREA BY BACKING UP FROM DOWNSTREAM. 19.ALL DEWATERING WATER AND RUNOFF WITHIN CONSTRUCTION AREAS SHALL BE TREATED VIA SEDIMENTATION, FILTRATION THROUGH VEGETATION IN APPROVED AREAS, OR PORTABLE FILTRATION SYSTEMS (UTILIZING TANKS AND FILTERS), AS NEEDED, PRIOR TO DISCHARGE TO DOWNSTREAM SYSTEM IN ORDER TO MEET ALL APPLICABLE LOCAL, STATE AND FEDERAL WATER QUALITY REGULATIONS. CONTRACTOR MAY ALSO DISCHARGE TO THE SANITARY SEWER SYSTEM AFTER OBTAINING APPLICABLE PERMITS AND MEETING PRETREATMENT REQUIREMENTS. ABERDEEN AVE NE STORM IMPROVEMENT PROJECT VICINITY MAP - ABERDEEN AVE NE STORM IMPROVEMENT PROJECT N NE SUN S E T B L V D PROJECT LOCATION PIPE 125752 PROJECT LOCATION PIPE 125875 AB E R D E E N A V E N E SU N S E T B L V D N E I - 4 0 5 NOT TO SCALE MDU H G P (GR3 D O G S U RI HVVLR3DO H 3J L 3 HHU UHJLVWHU H G VWDWH R I ZDV-L 3 J W R 3 7/20/2023 0+57-0+05 0+00 BP : - 0 + 0 5 . 0 0 PI : 0 + 0 0 . 0 0 PI : 0 + 5 2 . 3 2 EP : 0 + 5 7 . 3 2 CITY OF RENTON ROW FIRE HYDRANT 12" STORM 12" STORM 24" CONC STORM 18" STORM FACILITY ID: 136691 EX CATCH BASIN TYPE II RIM: 231.97 IE: 222.87-EX 12" (N) IE: 222.57-EX 24" (W) IE: 222.77-EX 24" (E) 12" STORM FACILITY ID: 136825 EX CATCH BASIN TYPE I RIM: 232.16 IE: 228.61-EX 24" (W) IE: 228.96-EX 12" (E) 16" WATER 12" WATER 12" WATER 8" SEWER CITY OF RENTON - LIGHT LUMEN - COMM PSE - POWER CITY OF RENTON ROW 1+57 0+95 1+ 0 0 BP: 0 + 9 5 . 0 0 EP : 1 + 5 6 . 9 9 PI: 1 + 0 0 . 0 0 PI : 1 + 5 1 . 9 9 CITY OF RENTON ROW 12" CONC STORM 18" CONC STORM FACILITY ID: 136685 EX CATCH BASIN TYPE II RIM: 211.58 IE: 199.08-EX 24" (E) IE: 199.06-EX 24" (SW) IE: 206.88-EX 12" (SE) FACILITY ID: 136731 EX CATCH BASIN TYPE I RIM: 213.00 IE: 205.60-EX 24" (W) IE: 206.30-EX 12" (N) IE: 205.80-EX 18" (S) CITY OF RENTON ROW 24" CONC STORM 24" CMP STORM 12" STORM FIRE HYDRANT 12" WATER 12" WATER 3/4" WATER WATER METER 10" SEWER 10" SEWER SEWER MANHOLE 4" SEWER FORCE MAIN 10" WATER CITY OF RENTON - LIGHT LUMEN - COMM 12" STORM EXISTING TREE CITY OF RENTON ROW SITE PREP PLAN SW P - 2 7 - 4 0 3 0 H:\ C A D \ _ P R O J E C T S \ S W P \ 2 7 - 4 0 3 0 _ A B E R D E E N \ D W G KEY NOTES DEMOLISH AND REMOVE EXISTING STORM STRUCTURE. PRESERVE AND PROTECT EXISTING STORM STRUCTURE. PRESERVE AND PROTECT EXISTING UTILITY. DEMOLISH AND REMOVE EXISTING STORM PIPE. DEMOLISH AND REMOVE EXISTING FIRE HYDRANT AND SPOOL. VALVE TO REMAIN. PRESERVE AND PROTECT EXISTING TREE. APPROXIMATE SAWCUT LIMITS. 1 2 3 4 5 6 7 Feet 0 40 80 DEMOLITION NOTES 1.THE WORK UNDER THE CONTRACT INCLUDES ALL CLEARING NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT WORK. CLEARING, GRUBBING, AND DEMOLITION WORK SHALL BE INCIDENTAL TO THE PROJECT. 2.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED AND REMOVED MATERIALS FROM THE SITE UNLESS OTHERWISE NOTED. 3.SEE SHEET "A" FOR ESC NOTES. 2 4 PLAN VIEW - PIPE 125752 Feet 0 40 80 N PLAN VIEW - PIPE 125875 ABERDEEN AVE NE STORM IMPROVEMENT PROJECT 2 3 3 3 3 3 3 3 3 3 1 1 3 3 3 3 3 3 33 3 3 3 5 3 3 4 3 3 3 3 3 3 6 N 7 7 7 7 7 LCT G F O EF4P C N F R T 4H G UUK4PCN GP I K P G GT TGI KUVGT G F UVCVG 4H YCUJKP I V 4P 7/20/2023 0+57-0+05 0+00 BP : - 0 + 0 5 . 0 0 PI : 0 + 0 0 . 0 0 PI : 0 + 5 2 . 3 2 EP : 0 + 5 7 . 3 2 CITY OF RENTON ROW FIRE HYDRANT 12" STORM 12" STORM 18" STORM 12" STORM 16" WATER 12" WATER 12" WATER 8" SEWER CITY OF RENTON - LIGHT LUMEN - COMM PSE - POWER NEW 52 LF 24" POLYPRO @ 11.16% FACILITY ID: 136825 EX CATCH BASIN TYPE I STA:0+52.32 RIM: 232.16 IE: 228.61 24" (W) IE: 228.96-EX 12" (E) FACILITY ID: 136691 EX 48" CATCH BASIN TYPE II STA:0+00.00 RIM: 231.97 IE: 222.87-EX 12" (N) IE: 222.57-EX 24" (W) IE: 222.77 24" (E) CITY OF RENTON ROW 1+57 0+95 1+ 0 0 BP: 0 + 9 5 . 0 0 EP : 1 + 5 6 . 9 9 PI: 1+ 0 0 . 0 0 PI : 1 + 5 1 . 9 9 CITY OF RENTON ROW 12" CONC STORM 18" CONC STORM CITY OF RENTON ROW 24" CMP STORM 12" STORM FIRE HYDRANT 12" WATER 12" WATER 3/4" WATER WATER METER 10" SEWER 10" SEWER SEWER MANHOLE 4" SEWER FORCE MAIN 10" WATER CITY OF RENTON - LIGHT LUMEN - COMM 12" STORM CB#1 NEW 48" CATCH BASIN TYPE II STA:1+00.00 RIM: 211.58 IE: 199.08 24" (E) IE: 199.06-EX 24" (SW) IE: 206.88-EX 12" (SE) NEW 52 LF 24" POLYPRO @ 12.54% CB#2 NEW CATCH BASIN TYPE I STA:1+51.99 RIM: 213.00 IE: 205.60 24" (W) IE: 206.30-EX 12" (N) IE: 205.80-EX 18" (S) EXISTING TREE CITY OF RENTON ROW 195 200 205 210 215 195 200 205 210 215 1+00 21 1 . 5 8 21 2 . 2 8 1+50 21 2 . 8 7 APPROXIMATE GRADE APPROXIMATE GRADE NEW 52 LF 24" POLYPRO @ 12.54% CB#1 NEW 48" CATCH BASIN TYPE II STA:1+00.00 RIM: 211.58 IE: 199.08 24" (E) IE: 199.06-EX 24" (SW) IE: 206.88-EX 12" (SE) CB#2 NEW CATCH BASIN TYPE I STA:1+51.99 RIM: 213.00 IE: 205.60 24" (W) IE: 206.30-EX 12" N IE: 205.80-EX 18" S CITY OF RENTON-LIGHT STA: 1+05.00 ELEV: NOT LOCATED 12" WATER STA: 1+17.00 ELEV: NOT LOCATED LUMEN-COMM STA: 1+48.99 ELEV: NOT LOCATED 10" SEWER STA: 1+40.50 ELEV: 208.10 12" STORM STA: 1+11.70 ELEV: 204.73 215 220 225 230 235 215 220 225 230 235 0+00 23 1 . 9 7 23 1 . 9 9 0+50 23 1 . 9 9 APPROXIMATE GRADE APPROXIMATE GRADE FACILITY ID: 136691 EX 48" CATCH BASIN TYPE II STA:0+00.00 RIM: 231.97 IE: 222.87-EX 12" (N) IE: 222.57-EX 24" (W) IE: 222.77 24" (E) FACILITY ID: 136825 EX CATCH BASIN TYPE I STA:0+52.32 RIM: 232.16 IE: 228.61 24" (W) IE: 228.96-EX 12" (E) NEW 52 LF 24" POLYPRO @ 11.16% CITY OF RENTON-LIGHT STA: 0+05.00 ELEV: NOT LOCATED 12" WATER STA: 0+10.77 ELEV: NOT LOCATED 8" SEWER STA: 0+33.82 ELEV: 223.13 LUMEN-COMM STA: 0+49.32 ELEV: NOT LOCATED PSE-POWER STA: 0+55.32 ELEV: NOT LOCATED STORM DRAINAGE PLAN SW P - 2 7 - 4 0 3 0 H:\ C A D \ _ P R O J E C T S \ S W P \ 2 7 - 4 0 3 0 _ A B E R D E E N \ D W G Feet 0 40 80 N 2 PLAN VIEW - PIPE 125752 Feet 0 40 80 N PLAN VIEW - PIPE 125875 ABERDEEN AVE NE STORM IMPROVEMENT PROJECT PROFILE VIEW - PIPE 125752 1"=20' HORIZONTAL 1"=4' VERTICAL STORM DRAINAGE NOTES 1.ALL IMPROVEMENTS SHALL FOLLOW CITY OF RENTON CITY STANDARDS. 2.POLYPROPYLENE PIPE SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. 3.ALIGNMENT OF NEW SYSTEM FOLLOWS ALIGNMENT OF EXISTING SYSTEM. STATIONS SHOWN ARE FOR DESIGN PURPOSE ONLY. CONTRACTOR TO VERIFY LOCATIONS OF NEW MANHOLES WITH ENGINEER PRIOR TO CONSTRUCTION. 4.CONSTRUCTION OF NEW STORM SYSTEM WILL IMPACT EXISTING SITE FEATURES INCLUDING BUT NOT LIMITED TO SIDEWALKS, CURB AND GUTTER, CONCRETE DRIVEWAY, HMA DRIVEWAY, ETC. ALL EXISTING SITE FEATURES SHALL BE REPLACED TO MATCH EXISTING SITE FEATURES PER CITY OF RENTON STANDARD PLANS UNLESS OTHERWISE NOTED. 4.1.COR STANDRAD PLAN 101 & 103: CEMENT CONCRETE TRAFFIC CURB AND GUTTER 4.2.COR STANDARD PLAN 102: CEMENT CONCRETE SIDEWALK 5.CONTRACTOR SHALL MAINTRAIN ONE LANE OF TRAFFIC AT ALL TIMES DURING CONSTRUCTION. PROFILE VIEW - PIPE 125875 1"=20' HORIZONTAL 1"=4' VERTICAL KEY NOTES CONNECT EXISTING STORM UTILITY TO NEW STRUCTURE. CONNECT NEW STORM UTILITY TO EXISTING STRUCTURES. RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20 ROUND FRAME AND COVER PER CITY OF RENTON STANDARD PLAN 204.50 SEE SHEET C200 FOR ADDITIONAL ABANDONMENT DETAILS PROVIDE NEW FIRE HYDRANT AND SPOOL TO EXISTING FIRE HYDRANT VALVE PER CITY OF RENTON STANDARD PLAN 310.1 APPROXIMATE SAWCUT LIMITS. 1 2 3 4 5 6 7 4 3 1 1 1 1 6 NOTE: DURING DESIGN INVESTIGATION AND LOCATES PSE EITHER DID NOT COME OUT OR DID NOT LOCATE A GAS LINE. THE CITY OF RENTON BELIEVES A GAS LINE MAY BE PRESENT AND IF FOUND THE GAS LINE SHALL BE PRESERVED AND PROTECTED. NOTE: DURING DESIGN INVESTIGATION AND LOCATES PSE EITHER DID NOT COME OUT OR DID NOT LOCATE A GAS LINE. THE CITY OF RENTON BELIEVES A GAS LINE MAY BE PRESENT AND IF FOUND THE GAS LINE SHALL BE PRESERVED AND PROTECTED. 7 7 7 7 7 LCT G F O EFQP C N F R T Q H GUUKQPCN GP I K P G GT TGI KUVGT G F UVCVG Q H YCU-KP I V QP 7/20/2023 PROJECT NO. DRAWN BY: DESIGNED BY: DA T E : RE V I E W E D B Y : DA T E NO . RE V I S I O N CK BY FIRST SUBMITTAL DATE: SHEET NO. Sa v e D a t e : Pl o t D a t e : 8/ 4 / 2 0 2 2 1 2 : 5 7 P M 8/ 1 6 / 2 0 2 2 1 0 : 4 8 A M By : Cf c h P: \ R \ R E N T 0 0 0 0 1 9 0 2 \ 0 4 0 0 C A D \ S H E E T S \ E C - S D - R E N T 0 0 0 0 1 9 0 2 - S 2 6 t h S t - 1 - X . d w g Cr a i g C h r i s t e n s e n By : Fi l e : CHECKED BY: ® S 2 6 T H S T - C U L V E R T I M P R O V E M E N T P R O J E C T CI T Y O F R E N T O N FOR CONSTRUCTION RENT00001902 14432 SE Eastgate Way Suite 400 Bellevue, WA 98007 425.519.6500 REENIGNELANOISSE FO R P 51063 DERETSIGER N O T G NIHSAWFOETATS NE S N E T SIRHC C RAIG F R A S E R APPROVED FOR COSTRUCTION BY DATETroy Solly Project Manager CO V E R CFCH/EH SYS/CFCH SS C P 6 3 SS C P 6 4 CFCH/EH RE N T O N WA 05/05/22 1 1 OF 3 CITY OF RENTON S 26TH ST CULVERT IMPROVEMENT PROJECT 2022 LIST OF DRAWINGS PROJECT LOCATION NOT TO SCALENOT TO SCALE LOCATION MAP VICINITY MAP 9/16/22 07/20/23 LEGEND PROJECT NO. DRAWN BY: DESIGNED BY: DA T E : RE V I E W E D B Y : DA T E NO . RE V I S I O N CK BY FIRST SUBMITTAL DATE: SHEET NO. Sa v e D a t e : Pl o t D a t e : 8/ 4 / 2 0 2 2 1 2 : 5 7 P M 8/ 1 6 / 2 0 2 2 1 0 : 4 9 A M By : Cf c h P: \ R \ R E N T 0 0 0 0 1 9 0 2 \ 0 4 0 0 C A D \ S H E E T S \ E C - S D - R E N T 0 0 0 0 1 9 0 2 - S 2 6 t h S t - 1 - X . d w g Cr a i g C h r i s t e n s e n By : Fi l e : CHECKED BY: ® S 2 6 T H S T - C U L V E R T I M P R O V E M E N T P R O J E C T CI T Y O F R E N T O N FOR CONSTRUCTION RENT00001902 14432 SE Eastgate Way Suite 400 Bellevue, WA 98007 425.519.6500 REENIGNELANOISSE FO R P 51063 DERETSIGER N O T G NIHSAWFOETATS NE S N E T SIRHC C RAIG F R A S E R APPROVED FOR COSTRUCTION BY DATETroy Solly Project Manager AB B R E V I A T I O N S , G E N E R A L N O T E S , AN D L E G E N D SYS/CFCH SS C P 6 3 SS C P 6 4 05/05/22 2 2 OF 3 CFCH/EH CFCH/EH RE N T O N WA 9/16/22 07/20/23 P PPPPP P PPPPP P PPPPP P P P P P P G G /// // / /// ( ( ( ( ( ( SD SD SD SD SD SD S 2 6 T H S T BENSON RD S T T T TTT T T T W W W W W W PPP 365 370 380 365 370 380 -0+250+001+001+20 0+001+001+20 37 8 . 3 37 8 . 2 6 37 6 . 8 37 6 . 7 8 37 2 . 1 37 2 . 0 8 83 LF± EX. 24" CMP @ 1.72% 15 LF± PROJECT NO. DRAWN BY: DESIGNED BY: DA T E : RE V I E W E D B Y : DA T E NO . RE V I S I O N CK BY FIRST SUBMITTAL DATE: SHEET NO. Sa v e D a t e : Pl o t D a t e : 9/ 1 6 / 2 0 2 2 1 1 : 3 9 A M 9/ 1 6 / 2 0 2 2 1 1 : 4 4 A M By : Cf c h P: \ R \ R E N T 0 0 0 0 1 9 0 2 \ 0 4 0 0 C A D \ S H E E T S \ E C - S D - R E N T 0 0 0 0 1 9 0 2 - S 2 6 t h S t - 1 - X . d w g Cr a i g C h r i s t e n s e n By : Fi l e : CHECKED BY: ® S 2 6 T H S T - C U L V E R T I M P R O V E M E N T P R O J E C T CI T Y O F R E N T O N FOR CONSTRUCTION RENT00001902 14432 SE Eastgate Way Suite 400 Bellevue, WA 98007 425.519.6500 REENIGNELANOISSE FO R P 51063 DERETSIGER N O T G NIHSAWFOETATS NE S N E T SIRHC C RAIG F R A S E R APPROVED FOR COSTRUCTION BY DATETroy Solly Project Manager PL A N A N D P R O F I L E AN D D E T A I L S SYS/CFCH SS C P 6 3 SS C P 6 4 05/05/22 3 SW 1/4 SEC. 29, TW 23 N, R. 5 W, W.M. CONSTRUCTION KEYNOTES ( FEET ) SCALE 1 INCH = 10 FT. 10 10 2050 I C A L HORIZONTAL SCALE IN FEET T R E V 0 1.25 2.5 520 010 3.75 3 OF 3 CFCH/EH CFCH/EH RE N T O N WA Know what's below.Call before you dig. TEMPORARY CONSTRUCTION EASEMENT/ CONSTRUCTION LIMITS 6 97 832 4 1 PLAN 832 DIRT GRASS S/W C/G ASPHALT PROFILE 1 10 POWER VAULT 97 10 GENERAL CONSTRUCTION NOTES 83 LF± EX. 24" CMP @ 1.72% PORTION OF EX. 24" CMP TO REMAIN 4 11 5 5 EX. SDCB 136925 IF UNDERMINING OCCURS, BACKFILL WITH CDF 9/16/22 07/20/23