HomeMy WebLinkAboutInspection DocN
SEE C1 FOR TESC
Scale: 1" = 10'
Drainage Site Plan
C3
Interlaken Engineering and Design, PLLC
Seattle, WA | (206) 470-9572
www.interlakenengineering.com
Revisions:
1"=10'
20
10
0
2023-11-30: Updated for City of
Renton Comments dated 11/17/23
Christelle Ridge - Lot 12
Interlaken Project No.: SEA-22-150
Site Address: 4413 NE 26th Pl
Jurisdiction: Renton
Parcel No.: 157108-0120
Applicant: Jaswinder Singh
Permit No.: B23005484
2024-02-05: Updated for City of
Renton Comments dated 1/4/24
B2
3
0
0
5
4
8
4
_
V
4
INSTALL 4" PERFORATED
FOOTING DRAIN ALONG ALL
BUILDING FOOTINGS.
03/10/26
FOOTING DRAIN MARKUP ONLY
INSTALL MIN. 22" DIA. FOOTING DRAIN
STORAGE STRUCTURE AND INSTALL
HARD WIRED 1/2 ZOELLER SUBMERSIBLE
SUMP PUMP OR APPROVED EQUAL.
RIM EL = 396.25'
IE 4" FOOTING DRAIN (S) = 392.25'
IE 1.5" DISCHARGE (W) = 395.0'
INSTALL 1.5" CHECK VALVE ON THE
DISCHARGE LINE
CONNECT ALL FOOTING
DRAINS TO 4" PVC (N), MIN.
1% SLOPE AND 1' COVER
1.5" FOOTING DRAIN
FORCEMAIN
CONNECT FOOTING DRAIN
FORCEMAIN TO CB #10.
IE 1.5" (NE) = 403.0'
REPLANT TREE(S)
REMOVED FOR
FOOTING DRAIN
DISCHARGE LINE
INSTALLATION
REVISION
Received: 03/30/2026 / striplett
BUILDING DIVISION
DEVELOPMENT ENGINEERING
HHuynh 04/10/2026