Loading...
HomeMy WebLinkAboutEx02_Project_Narrative Civil Engineering & Development Services 1700 NW Gilman Blvd; Ste 200; Issaquah, WA 98027 Phone: (425) 821-5038 Email: Info@G2CIVIL.COM Varma 3-Lot Short Plat Project Narrative Project Location: 3664500205 13014 156TH AVE SE 98059 Existing Conditions The subject parcel is currently developed with a single-family residence. The project site slopes gradually to the southeast and southwest at approximately 3%, creating a split drainage basin. Zoning = R-4 Existing Lot Size = 45,872 sf (1.05 acres) Proposed Project Scope This project is proposing the subdivision of this parcel into 3 single-family lots (Refer to Exhibit B). Each lot will maintain the minimum lot requirements for R-4 Zoning. The density estimate is as follows: Existing Lot Size = 45,872 sf (1.05 acres) 1.05*4 du/ac = 4 dwelling units 3 units is proposed due to the location of the existing residence and setback requirements. Access, Traffic, and Circulation: The required frontage improvements along 156th Ave SE have been installed as part of the recent single family residence building permit. The parcels will access 156th via a shared driveway along the north property line, where the existing driveway was installed. By keeping the access easement below 150’ long, a fire turnaround is not proposed. “J. SHARED DRIVEWAY STANDARDS: 1. Where Permitted: Shared driveways may be allowed for access to no more than four (4) residentially zoned lots, and no more than four (4) residential units, the types of which are listed in RMC 4-2-060C, provided: Exhibit 2 Docusign Envelope ID: 85515A60-0856-8EA6-8102-3141314330A5 Varma 3-Lot Short Plat Renton, WA a. At least one lot abuts a public right-of-way and the street frontage of the lot is equal to or greater than the lot width requirement of the zone; b. The subject lots are not created by a subdivision of ten (10) or more lots; c. A public street is not anticipated by the City of Renton to be necessary for existing or future traffic and/or pedestrian circulation through the short subdivision or to serve adjacent property; d. The shared driveway would not adversely affect future circulation to neighboring properties; e. The shared driveway is no more than three hundred feet (300') in length; and f. The shared driveway poses no safety risk and provides sufficient access for emergency vehicles and personnel. (Ord. 6068, 6-13-2022)” The proposed shared driveway has been compared to the requirements provided in the City of Renton Street Standards. a. One of the new parcels will be adjacent to 154th Ave SE with a frontage of approximately 133’ after recording the access tract. b. The subdivision creating the driveway is a 3-lot subdivision, less than 10. c. While the City of Renton has identified the need for a future public street in this area, the parcel to the south provides a potential through access route along the south boundary that provides adequate setbacks to existing structures. d. No future access to neighboring properties rely on expansion of this shared driveway. The residence to the north is a flagpole and was recently developed, the property to the east has access readily available from 158th Avenue. e. The shared driveway will be approximately 150’ in length, less than the 300’ maximum. f. No safety risks associated with the shared driveway have been identified and sufficient access for emergency vehicles has been provided. ALLEY ACCESS: RMC 4-7-150.E.5 requires alley access to be provided for all new residential development. Addition of an alley to this project is not feasible for the following reasons. Significant Tree Retention The primary constraint on this site is the presence of significant trees located directly within the potential alley tract. Constructing a paved alley would require the removal of these trees. omitting the alley allows us to prioritize tree retention, which aligns with the city’s environmental goals and the intent of the R-4 low-density designation. Docusign Envelope ID: 85515A60-0856-8EA6-8102-3141314330A5 Varma 3-Lot Short Plat Renton, WA Physical Infeasibility and Site Constraints Given the dimensions of this specific R-4 parcel, the dedication of a 20-foot alley tract significantly reduces the usable building envelope. Forcing an alley into this layout creates a hardship that is not proportionate to the limited number of units in this short plat. The site can be more efficiently served by the Shared Private Driveway, which preserves the natural topography and existing vegetation. Stormwater Flow Control The proposed development has been carefully designed to minimize the potential increase in stormwater runoff and gained exemption from providing flow control facilities by utilizing onsite stormwater BMP’s. The available BMP’s require the downhill side of the future houses to provide a 25’ flow path, which would be impossible should an alley be required for this development. Per RMC 4-7-150E.5, we request that the Administrator determine that an alley is not practical for this development. We are committed to a design that meets all safety and access standards without the unnecessary impact of an alleyway. Utilities: The short plat will be served by Water District 90 for potable water and The City of Renton for sewer service. Stormwater management will be in accordance with the King County Stomwater Manual and the City of Renton Manual with a focus on utilizing onsite Flow control BMP’s to the maximum extent possible. Tree Retention: In accordance with the new City of Renton Tree retention codes, the project will retain 30% of the existing trees onsite and meet the tree retention credits per acre. Exhibits: Exhibit A - Vicinity Map Exhibit B – Proposed Plat Plan Exhibit C – Density Worksheet Docusign Envelope ID: 85515A60-0856-8EA6-8102-3141314330A5 Varma 3-Lot Short Plat Renton, WA EXHIBIT A Vicinity Map, courtesy of COR Map Docusign Envelope ID: 85515A60-0856-8EA6-8102-3141314330A5 Varma 3-Lot Short Plat Renton, WA EXHIBIT C DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT DENSITY WORKSHEET 1. Gross area of property 45872 square feet 2. Deductions: Certain areas are excluded from density calculations. These include: Public Streets* 0 square feet Private access easements* 4198 square feet Critical Areas** square feet Total excluded area: 4198 square feet 3. Subtract line 2 (total excluded area) from line 1 for net area 41,674 square feet 4. Divide line 3 by 43,560 for net acreage 0.96 acres 5. Number of dwelling units or lots planned 3 units/lots 6. Divide line 5 by line 4 for net density 3.1 = dwelling units/acre *Alleys (public or private) do not have to be excluded. **Critical Areas are defined as “Areas determined by the City to be not suitable for development and which are subject to the City’s Critical Areas Regulations including very high landslide areas, protected slopes, wetlands, or floodways.” Critical Areas buffers are not deducted/excluded. Docusign Envelope ID: 85515A60-0856-8EA6-8102-3141314330A5