HomeMy WebLinkAboutMFP26001878.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP26001878
IVR Number: 26001878
Permit Information
Permit Name: Puget Sound Energy - Electric
101191179- City PI Project- Highlands Reservoir Water MainAddress/Location:04/13/2026Application Date:0923059061Parcel Number: 1140 EDMONDS AVE NE
Permit Type:05/13/2026Issue Date:Franchise
Permit Work Class:05/13/2027Expiration Date:Major Utility
Job Number: 101191179Franchise Type:Electric
Description: Puget Sound Energy Electric ***RUSH PLEASE*** City PI Project PSE to relocate by beginning of May. Highlands
Reservoir Water Main Project. Crew Trenching to relocate multiple underground electric facilities. Install one new
vault. All restoration to be completed to city standards. ***Per PSE WSDOT PERMIT SPECIALIST SR 900 MP 13.21.
It's within City limits with no restrictions. The city has permitting jurisdiction.***
Contacts
Name Address PhoneTypeBilling
Katie Zimmerman
Puget Sound Energy
1660 Park Lane
Burlington, WA 98233
B: (425) 620-6742
C: (425) 620-6742
ApplicantX
Permits Central 355 110th Ave NE
Bellevue, WA 98004
B: (425) 620-6742
H: (425) 620-6742
C: (425) 620-6742
Applicant
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Katie Zimmerman
Puget Sound Energy
1660 Park Lane
Burlington, WA 98233
B: (425) 620-6742
C: (425) 620-6742
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton codes and ordinances. Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for
ANY work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
PUBLIC WORKS DEPARTMENT
Page 1 of 6 | Published: 2/25/2025
Transportation Systems Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 2/25/2025
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK AND FOR TRAFFIC SIGNAL
WORK WITHIN 150 FEET OF THE INTERSECTION AT LEAST FIFTEEN (15) WORKING DAYS BEFORE THE DATE OF WORK.
FOR PURPOSES OF THIS APPLICATION, WORKING DAYS ARE DEFINED AS MONDAY THRU FRIDAY, AND EXCLUDING
CITY HOLIDAYS.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a Traffic
Control Plan (TCP) and obtain City's approval of that plan when construction, repair, or maintenance work is to be
conducted within the City's right-of-way.
1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2.All TCPs must conform to all attached requirements. Failure to do so may be subject to resubmittal.
3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
4.Resubmittal may be required for TCPs that are incomplete and do not display proper requirements as
described in the guidelines. Additional review time may be needed.
By signing, I certify that the information on this application and within the submittal documents are accurate to the
best of my knowledge and I acknowledge and have read all the requirements and guidelines on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip: ___________
Description of Work:
24 Hour Emergency
Contact Name & Phone:
Approval By: ______________________________________________ Date:____________________
PW/Transportation or CED/Development Engineering Division
Potelco, Inc
6905 S 228th St Kent, WA 98466
Please See Attached
Katie Zimmerman
4/13/2026
101191179-Highlands Reservoir Water Main- City PI Project
1140 Edmonds Ave NE
Dustin Weller (206) 379-4347
Monday Friday 8:00am 3:00pm
Scott Warlick CED 5/13/2026
MFP26001878
Page 2 of 6 | Published: 2/25/2025
This Page Intentionally Left Blank
Page 3 of 6 | Published: 2/25/2025
APPLICANT AGREES TO ALL THE FOLLOWING REQUIREMENTS:
GENERAL
•Applicant is responsible for compliance with all traffic regulations of the City of Renton (City) and the State
of Washington, including codes and regulations not described in this application.
•Work Zone Traffic Control shall be in accordance with Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to Washington State Department of Transportation
(WSDOT) traffic control plans.
•Any lane or street closures not in conformance with the approved Traffic Control Plan (TCP) and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs
or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable
State and City codes.
•Indemnify and hold harmless the City from any and all claims, actions, and judgments, including all costs of
defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved TCPs including claims arising from towing of private vehicles and the acts
of Applicant’s agents and employees.
•Applicant must comply with all conditions of the application.
•The City shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such
event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against City within the scope of this application, Applicant is
responsible to pay for legal counsel chosen by the City to defend against same.
•No more than one TCP shall be in use at any given time for a single project. If multiple TCPs are submitted
for review and approval at the same time, the TCPs shall be clearly labeled as separate plans and include
construction phasing and sequencing.
•Previously approved TCPs cannot be combined into a new TCP without review and approval by the City.
•Expired TCP is not valid and shall not be used. Applicant shall resubmit the expired TCP for approval with
the updated date and time and/or any changes to TCP.
•Applicant must have the approved TCP prior to commencing the work.
•Approved TCP must be at the work site during work hours.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number
at a conspicuous place on the vehicle or equipment.
•At signalized intersections, vehicle detection shall always remain operational, unless approved in this TCP
and notified Transportation Signal Maintenance prior to commencing work. If damage occurs to existing
vehicle detection that is to remain, it is Applicant’s responsibility to replace with video vehicle detection
equipment that meets current City’s standards at Applicant’s expense.
•When not in use, temporary traffic control devices shall be removed or covered immediately. It is the
Applicant’s responsible to cover any temporary traffic control devices when not applicable for the
construction activities. Similarly, when work is suspended for short periods of time, traffic control devices
that are no longer necessary shall be removed or covered. If deemed abandoned, City crews will remove
and may store them at the City’s maintenance shop (3555 NE 2nd Street) for up to sixty (60) days. The City
is not responsible for any private property from City assets and identifying the property owner.
•Applicant is responsible to maintain existing pedestrian accessible routes during work and non-work hours.
At intersections, the work on pedestrian facilities shall be limited to one (1) corner at a time, with the least
possible inconvenience or delay to pedestrians. Pedestrian pushbuttons shall remain accessible at all times,
unless approved pedestrian accessible detour(s) are provided. Accessibility to existing or temporary
Page 4 of 6 | Published: 2/25/2025
pedestrian pushbuttons shall not be impaired. Deficiencies caused by Applicant’s operations shall be
repaired at Applicant’s expense.
•Applicant shall provide complete assistance and accommodation from a dedicated pedestrian escort to all
kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a
work zone.
•Driveway and alley access shall be maintained at all times, also see RMC Chapters 9 and 10 for Street
Closure and Street Excavation for details. Applicant is responsible for coordinating with the property
owners and/or residents prior to commencement of the work.
•Pavement excavation shall be limited to a maximum of one travel lane at a time unless otherwise
approved.
•Accessibility for emergency vehicles shall be maintained at all times.
PUBLIC OUTREACH
•Applicant must notify Transportation Signal Maintenance (425-430-7423) and City inspector (425-430-
7203) at least twenty-four (24) hours before commencing work (lane shift/closure or near a signal)
affecting the vehicle detection.
•Applicant shall notify emergency services (253-852-2121) twenty-four (24) hours before any street closures
or lane closures.
•Applicant shall call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five (5) working days (excluding
weekends and holidays) prior to starting any work.
•Applicant shall coordinate with King County Metro Transit Construction Information Center (206-477-1140
or construction.coord@kingcounty.gov) for any construction or installation activities affecting transit
operations or facilities. Notification information and guidelines can be found at:
https://kingcounty.gov/en/dept/metro/about/contractor-resources/transit-system-impacts.
WORKING DAYS AND TIMES
•Normal working days are Monday through Friday. Work on holidays, weekends or at night shall not occur
without City’s approval. For work times between 10:00 p.m. and 7:00 a.m., see Night Work section below
for details.
•Work time begins when any street or travel lane is fully or partially closed. This includes set up and removal
within the traveled way.
•If the City determines the closure hours adversely affect traffic during the work, the City may require to
adjust or reduce the working hours accordingly. Reduced work hours may be required by the City to
minimize traffic impacts for any work located near a school during pick-up and drop-off times or on an
arterial street. (See WSDOT Functional Classification Map:
https://www.wsdot.wa.gov/data/tools/geoportal/?config=FunctionalClass)
•Applicant may request the City for consideration of extended or modified working hours. Such request
must be approved by the City before changing hours of work.
CLOSURES
•All closure hours and days are subject to local permit and ordinance conditions (such as noise ordinances).
More information can be found on https://www.rentonwa.gov/City-Services/Permit-Center. Total street
closure lasting more than twenty-four (24) hours is subject to City Council authorization per Section 9-9 of
the Renton Municipal Code (RMC).
•Road closure notice – Applicant must install Portable Changeable Message Sign (PCMS) boards no less than
five (5) working days in advance of effective date and time, not including holidays, at location(s) as
identified in the TCP. Other methods of displaying the messages shall be approved by the City.
Page 5 of 6 | Published: 2/25/2025
•Road closure notice messages must include at least the following:
ROAD WILL BE CLOSED
MONTH/DAY – MONTH/DAY
_AM - _PM
•Road and/or sidewalk closure must be evaluated by the City with respect to both the necessity as well as
the impact of the closure to the public. Applicant shall submit detour plans for road closures to
accommodate both motorized and non-motorized users, including accessible pedestrian route(s). Road
closures shall require additional temporary traffic control including advance notification, approach and
detour signage.
•Applicant is responsible to temporarily remove the flags and install bags over the flag holders for any work
requiring the temporary closure of a crosswalk equipped with pedestrian flags. Applicant shall ensure the
bags remain intact and shall replace damaged bags as needed or determined necessary by the City of
Renton inspector. For any misplaced or lost flags, Applicant is responsible to replace at Applicant’s own
expense. Upon restoration of the crosswalk, Applicant shall remove the bags and return all flags to the
holders. Inventory of pedestrian flags must be submitted to the City inspector and reported to City of
Renton Transportation Signal Maintenance (425-430-7423) prior to removal.
UNIFORMED POLICE OFFICERS (UPO) / FLAGGERS
•Any construction activities within one hundred and fifty (150) feet of a signalized intersection shall require
Uniformed Police Officer(s) (UPO) at the traffic signal, unless otherwise approved in this TCP and evaluated
by City Transportation for the impacts of traffic signal operations and safety.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic
or pedestrian safety or travel.
•For TCPs that require the presence of UPO to manage vehicular traffic and pedestrians at signalized
intersections, Applicant shall coordinate with Transportation Signal Maintenance (425-430-7423) at least
twenty-four (24) hours in advance for any signal that will be placed in red flashing mode. Applicant shall
notify Transportation Signal Maintenance when the intersection is back to the normal traffic signal
operations.
TEMPORARY TRAFFIC SIGNALS OR TRAFFIC SIGNAL MODIFICATION
•Temporary traffic signal programming or modification requires a minimum fifteen (15) working days for
each traffic signal controller to be programmed and tested by City Transportation staff before starting the
work. The Start Date on this TCP shall reflect the time for temporary traffic signal programming or
modification.
TEMPORARY NO-PARKING
•Applicant must post notice of date(s) and time(s) of Temporary No Parking Zone with signs at every
hundred (100) feet at least seventy-two (72) hours in advance of effective date and time.
•Applicant is responsible to show on the TCP the limits of Temporary No Parking Zone, identifying barricade
locations for vacate parking or curb lane usage. The cover sheet of this approved TCP form must be
attached to each Temporary No Parking Sign on the project site.
•Two travel lanes (one for each approach) must be open at all times on arterial streets unless approved in
this TCP.
NIGHT WORK
•Between the hours of 10 p.m. and 7 a.m., approved Noise Variance shall be required (See Section RMC 8-7-
8)for night work. Process may take up to twelve (12) weeks. More information can be found at
https://www.rentonwa.gov/City-Services/Permit-Center/Land-Use-Development/Noise-Variance.
•City may require night work for TCPs that have severe traffic impacts on arterial streets.
Page 6 of 6 | Published: 2/25/2025
•Night work shall always be required if two lanes of traffic (One for each approach) cannot be maintained
on an arterial street.
•Night work shall be required if an evaluation of existing traffic volumes and patterns finds that any TCP will
functionally reduce an arterial or high-volume collector street to only one lane of traffic.
•The following configurations may require night work:
Work at traffic signals that requires shifting one direction of traffic into a left turn pocket where a high
volume of left turns occur.
Work at traffic signals that requires shifting two directions of traffic into left turn pockets.
Work at traffic signals that requires shifting high-volume left-turn movement into a through lane on a
single approach to the intersection.
Work at signals that requires shifting left-turning traffic into a through lane on multiple approaches to
the intersection.
•If City’s initial TCP review finds that night work is required, a pre-construction meeting is mandatory to
confirm the extents of the work required, the duration of work, anticipated noise levels, and any potential
alternatives to mitigate the impact of night work to adjacent residents prior to review and approval of the
TCP.
TRAFFIC CONTROL PLAN (TCP) FORMAT
•TCP must be site and project specific. The TCP shall clearly indicate all existing transportation facilities
impacted by work including roads, bike lanes, sidewalks, transit stops, and driveways. Typical drawings,
taper tables and MUTCD illustrations, by themselves, are insufficient.
•Each construction phase shall be provided with appropriate work zone traffic control. The impacts of utility
relocation, traffic delays, detours and capacity restrictions must be considered and addressed. A suitable
sequence of construction activities must be discussed with City Staff prior to fully developing TCPs based on
the complexity of a project.
•TCPs shall be clearly labeled as separate plans to identify the construction sequencing during each phase
when more than one TCP layout is submitted.
•TCP must be submitted with an electronic copy of TCP layout(s), on 11” X 17” paper size PDF format, which
consist of:
Map(s) showing the location of the project and work area.
All fonts shall be legible and a minimum 10-point font size.
All symbols of viewing or printing shall be clear and contrasting.
All streets shall be labeled, and layout must include a north arrow and scale.
Must show channelizing devices, signing, flagger locations, barricades, PCMS boards, etc.
Show locations where the standard traffic control plans are applied.
1140 Edmonds Ave NE
Renton
WA 98056
USA
DA
Y
T
O
N
P
L
N
E
ED
M
O
N
D
S
A
V
E
N
E
1515
12
12
2121
1010
ED
M
O
N
D
S
P
L
N
E
15
15
101121
20
20
20
20
NE 12TH ST
NE 12TH ST PV1
IP1
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥X'≥
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5RW1-4L
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥
W1-4R
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
FRO
M
TO
TO
W
A
W
A
Y
A
R
E
A
PH
O
N
E
6
8
4
-
5
4
4
4
NAM
E
O
F
F
I
R
M
X
X
X
-
X
X
X
-
X
X
X
X
NO
P
A
R
K
I
N
G
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
IP2 IP3
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
1 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRONARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
MFP26001878
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
20
20
1515
BU
S
ST
O
P
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 13
T
H
S
T
1
2
1
2
1010
IP4 V02
NE 12TH ST
CO
N
E
TO
P
P
E
R
maintain (2) 11' lanes
CO
N
E
TO
P
P
E
R
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥X'≥
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5RW1-4L
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥
W1-4R
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
CO
N
E
TO
P
P
E
R
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
2 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
MFP26001878
1616
17
17
NE 12TH ST
JE
F
F
E
R
S
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
20
20
1515
HA
R
R
I
N
G
T
O
N
P
L
N
E
17
17
IP5 IP6
IP8NE 12TH ST
20
20
20
20 CO
N
E
TO
P
P
E
R
maintain (2) 11' lanes
CO
N
E
TO
P
P
E
R
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥X'≥
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5RW1-4L
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥
W1-4R
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
W20
-
1
RO
A
D
W
O
R
K
AH
E
A
D
X'≥
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
3 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
1616
17
17
1818
NE 12TH ST
KI
R
K
L
A
N
D
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
NE 12TH ST
JE
F
F
E
R
S
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
P
L
N
E
17
17
J03
IP7
NE 12TH ST
IP8J02
FRO
M
TO
TO
W
A
W
A
Y
A
R
E
A
PH
O
N
E
6
8
4
-
5
4
4
4
NAM
E
O
F
F
I
R
M
X
X
X
-
X
X
X
-
X
X
X
X
NO
P
A
R
K
I
N
G
W20-1
RO
A
D
WO
R
K
AH
E
A
D
W21-5
SH
O
U
L
D
E
R
WO
R
K
X'≥X'≥
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
W20
-
1
R
O
A
D
W
O
R
K
AH
E
A
D
X'≥
W2
0
-
1
ROAD
WORK
AHEAD
X'
≥
20
20
J04
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
4 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
1616
17
17
1818
NE 12TH ST
KI
R
K
L
A
N
D
A
V
E
N
E
K
I
R
K
L
A
N
D
A
V
E
N
E
NE 12TH ST
JE
F
F
E
R
S
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
P
L
N
E
17
17
J03
IP7NE 12TH ST
20
20
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥X'≥X'≥
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5R W1-4L
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
maintain (2) 11' lanes
W20-1
RO
A
D
WO
R
K
AH
E
A
D
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
CO
N
E
TO
P
P
E
R
CO
N
E
TO
P
P
E
R
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
5 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
10
10
10
10
10
10
10
10
10 11
11 11 11
10 11
11
11 11
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
1818
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
1616
1818
LY
N
N
W
O
O
D
A
V
E
N
E
NE 12TH ST
KI
R
K
L
A
N
D
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
NE 12TH ST
JE
F
F
E
R
S
O
N
A
V
E
N
E
100'
IP9
V03
W20-1
RO
A
D
WO
R
K
AH
E
A
D
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5R W4-2R
X'≥X'≥X'≥
W20-1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
W20
-
1
RO
A
D
W
O
R
K
AH
E
A
D
X'≥
ARRW-BRD
POLICEUPO
W21-1
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
6 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
N
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
10
10
10
10
10
10
10
10
10
11
11
11
11
10
11
11 11
11
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
1818
22 11 11
5
1
3
1
1
1
0
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
11
1
1
1
2
1
1
1
1
1818
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
NE 12TH ST
KI
R
K
L
A
N
D
A
V
E
N
E
1
0
0
'
IP9
ARRW-BRD
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
RIG
H
T
L
A
N
E
CL
O
S
E
D
AHE
A
D
W20
-
5
R
W4-
2
R
X'≥
X'≥
X'≥
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
IP13
IP12
ARRW-BRD
W20-1
RO
A
D
WO
R
K
AH
E
A
D
RIG
H
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5RW4-2R
X'≥X'≥X'≥
C/WCLOSE
D
R9
-
3
DETOU
R
M4
-
9
B
S/
W
C
L
O
S
E
D
R9-9
CROSSWALK REMAIN OPEN
D
E
T
O
U
R
M4-9
B
W2
0
-
1
ROAD
WORKAHEAD
X'
≥
W2
0
-
1
ROAD
WORKAHEAD
X'
≥
POLICEUPO
BEPR
E
P
A
R
E
D
TO
ST
O
P W3-
4
X'≥
X'≥
W20
-
7
A
BE
PR
E
P
A
R
E
D
TO
ST
O
P
W3-4
X'≥X'≥
W20-7A
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
BE PR
E
P
A
R
E
D
TOSTO
PW3-
4
X'≥
X'≥
X'≥
W20
-
7
A
W20-1
RO
A
D
WO
R
K
AH
E
A
D
BE
PR
E
P
A
R
E
D
TO
ST
O
P
W3-4
X'≥X'≥X'≥
W20-7A
W
2
0
-
1
ROAD
WORK
AHEAD
W2
0
-
1
ROAD
WORK
AHEAD
SET SIGNAL INTO A FLASH MODE.
(ALL WAY STOP)
(2 ) UPO shall control the intersection
POLICEUPO
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
7 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
N
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
10
10
10
10
10
10
10
10
10
11
11
11
11
10
11
11 11
11
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
1818
22 11 11
5
1
3
1
1
1
0
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
11
1
1
1
2
1
1
1
1
1818
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
NE 12TH ST
NE
S
U
N
S
E
T
B
L
V
D
KI
R
K
L
A
N
D
A
V
E
N
E
1
0
0
'
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
IP10
IP11
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
STOP
STOP
BEPREPARED
TOSTOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W2
0
-
1
ROAD
WORK
AHEAD
CENTER LANE
CLOSEDAHEAD
W9
-
3
X'
≥
W2
0
-
1
ROAD
WORK
AHEAD
BE
PREPARED
TO
STOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W20-1
RO
A
D
WO
R
K
AH
E
A
D
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
STOP
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
STOP
W20-1
RO
A
D
WO
R
K
AH
E
A
D
LE
F
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5L W4-2L
X'≥X'≥X'≥
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
8 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
N
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
10
10
10
10
10
10
10
10
10
11
11
11
11
10
11
11 11
11
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
1818
22 11 11
5
1
3
1
1
1
0
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
11
1
1
1
2
1
1
1
1
1818
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
NE 12TH ST
NE
S
U
N
S
E
T
B
L
V
D
KI
R
K
L
A
N
D
A
V
E
N
E
1
0
0
'
IP10
IP11
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
STOP
STOP
BEPREPARED
TOSTOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W2
0
-
1
ROAD
WORK
AHEAD
CENTER LANE
CLOSEDAHEAD
W9
-
3
X'
≥
W2
0
-
1
ROAD
WORK
AHEAD
BE
PREPARED
TO
STOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
W20-1
RO
A
D
WO
R
K
AH
E
A
D
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
STOP
STOP
W20-1
RO
A
D
WO
R
K
AH
E
A
D
LE
F
T
L
A
N
E
CL
O
S
E
D
AH
E
A
D
W20-5L W4-2L
X'≥X'≥X'≥
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
X'≥
W20
-
1
RO
A
D
W
O
R
K
AH
E
A
D
X'≥
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
9 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
N
Fire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
10
10
10
10
10
10
10
10
10
11
11
11 11
10
11
11 11
11
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
1818
22 11 11
5
1
3
1
1
1
0
1717
10
1
0
1
0
1
0
10
1
0
1
0
1
0
11
1
1
1
2
1
1
1
1
1818
LY
N
N
W
O
O
D
A
V
E
N
E
MO
N
R
O
E
A
V
E
N
E
NE 12TH ST
NE 12TH ST
KI
R
K
L
A
N
D
A
V
E
N
E
1
0
0
'
BE
PREPAREDTO
STOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W2
0
-
1
ROAD
WORKAHEAD
W2
0
-
1
ROAD
WORK
AHEAD
BE
PREPARED
TOSTOP
W3
-
4
X'
≥
X'
≥
X'≥
W2
0
-
7
A
W20-1
RO
A
D
WO
R
K
AH
E
A
D
W20-4
ON
E
L
A
N
E
RO
A
D
AH
E
A
D
X'≥X'≥X'≥
W20-7A
STOP
STOP
P01A
STOP
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
BEPR
E
P
A
R
E
D
TOST
O
P W3-
4
X'≥
X'≥
X'≥
W20
-
7
A
W20-1
RO
A
D
WO
R
K
AH
E
A
D
BE
PR
E
P
A
R
E
D
TO
ST
O
P
W3-4
X'≥X'≥X'≥
W20-7A
CO
N
E
TO
P
P
E
R
KE
E
P
R4
-
7
B
RI
G
H
T
W20
-
1
RO
A
D
WO
R
K
AH
E
A
D
BE PR
E
P
A
R
E
D
TO
ST
O
PW3-
4
X'≥
X'≥
X'≥
W20
-
7
A
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
jaber Tofan
425-424-7701
Jaber.tofan@pse.com
10 OF 101140 Edmonds Ave NE, Renton, WA 98056
2
12090664
05/06/2026
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. All signs shall be sized as outlined in sections 6G and 6H
of the MUTCD unless otherwise specified.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
VALVE LOCATIONv
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound EnergyTraffic Control Supervisor:Jaber Tofan
Card No. ES2 000434
Card Exp. 02/18/2028
Jaber.Tofan@pse.com
(425)424-7701
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
45/65
20/40
10-20
10-20
80
40
2-Way, 1-Lane Alternating Traffic
NFire Station #12.
Coordinate this work
with the fire
department and
ensure that
emergency vehicles
are able to enter and
exit the firestation.
MFP26001878
N
Vicinity Map
10
1
1
9
1
1
7
9
R
1
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
HIGHLANDS RESERVOIR WATER MAIN
PI RELOCATION
PSE CAPITAL PROJECT
GENERAL SPECIFICATIONS
Scope of Work
The city of Renton is installing new water and storm drain structures along NE 12th St,
starting from its intersection with Edmonds Ave NE and ending at Queen Ave NE. In
support of this work, PSE will be relocating the UG power, where possible, to avoid
any conflicts with the water main and storm drain structures.
General
-All work is to be completed per PSE Standards & Practices. Copies of all PSE
Standards are available upon request.
-Work sites shall be kept clear of debris and all construction materials; equipment
and packing shall be removed daily.
-Return all unused and removed poles, transformers and hardware to PSE,
storeroom. All copper shall be coiled and returned the day it is removed from the
poles. Remove all unused pins and insulators.
-Return all streetlights, area lights and floodlights to Sumner yard.
Preconstruction
- Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by
permitting agency, in advance of starting work in Right-of-way involving a Permit.
- All system switching shall be approved by System Operations (425-882-4652) a
minimum of 48 hours in advance.
- Notify customers of all outages 48 hours in advance.
Work Drawings & Documents
- Field design changes shall be approved by PSE Project Manager or Engineer.
- Mark all field changes, equipment ID numbers and Underground cable information in
red on Foreman's copy of worksketch.
- Return one Foreman's copy of worksketch to Project Manager at completion of job.
- When permits are required, a copy shall be available on work site at all times.
Safety
- Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements.
- Refer to PSE standards 6275.9050 for personal protective grounding requirements.
- Refer to PSE standards 6275.9150 for vehicle grounding and barricading
requirements.
- Proper line clearances shall be taken at the beginning, and released at the end, of
each work day, or as otherwise instructed by the System Operator.
- Provide signs, barricades, and traffic control in conformance with permit regulations.
- Utilize flagging and other vehicle traffic control as necessary and in conformance with
local traffic regulations.
- Maintain traffic flow as required by permitting agency.
Erosion & Sediment Control
- Refer to PSE standards 0150.3200 for minimum requirements.
- Comply with all requirements of permitting agency.
- Installed erosion & sediment devices shall be maintained until vegetation has been
re-established or disturbed soil has been otherwise permanently stabilized.
Joint Facilities
- Coordinate with Communication Companies for transfers.
OVERHEAD CONSTRUCTION
Poles & Structures
- Poles are to be installed or relocated as staked. Unless otherwise noted, all pole
location measurements are from the center of the pole.
- All new poles set shall be the class indicated on the sketch, or better. Do not set a
lower class pole than specified.
- Install ground plate assembly on all new poles. Install Switch Ground Assembly per
standard specification 6014.1000 at new gang operated switch locations.
- Install grid numbers on all new and existing poles as shown on sketch.
- Straighten existing poles as indicated or as necessary.
- Treat all field-drilled poles with copper napthenate wood preservative.
- Remove old poles after communication companies have transferred off and return to
PSE storeroom. Fill and crown pole holes and restore area similar to adjacent
landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors
and guys to new poles set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all
transformers. Install at all sites being worked within the scope of the project where
they are currently missing.
- Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600
amp switch jumpers. Install tree wire conductor for jumpers on all poles that are
double deadended with tree wire.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise
shown on the drawing.
- All neutral connections to be made with solid compression connectors. Connect all
pole grounds to common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and
underground taps with fused protection above 40T.
- Install Wildlife Protectors on all transformers.
UNDERGROUND CONSTRUCTION
Excavation
-Trenching outside of the Right-of-way shall be of sufficient depth to provide a
minimum of 36” of cover for primary conductors and 24” of cover for secondary
conductors.
-Road crossings and all trenches within the Right-of-way shall be of sufficient depth
to provide a minimum of 36” of cover for all conductors or as required by the
permitting Agency.
-All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand
cover.
-No rocks larger than 6” shall be included in backfill.
-Backfill in road crossings and within the Right-of-way shall be compacted to 95%
density or as required by the permitting Agency.
-Restore all excavated areas to original condition.
- If four or more six inch conduits are installed in a trench, fluidized thermal backfill
(FTB) shall be installed around the conduits to a depth of six inches above and to
the sides of the conduit, and two inches underneath, per PSE Standard 6790.0140.
Vaults & Handholes
- Refer to PSE standard 6775.0040 “Vault and Handhole Installation”
- Vaults shall be placed level and 2” above final grade in landscaped areas and flush
with final grade when placed in hard surface areas.
- A minimum 6” bed of 5/8” crushed rock shall be placed under all vaults.
- All conduit entrances shall be grouted.
Conductors & Conduit
- Refer to PSE standard 6800.6000 “PVC Conduit Installation”.
- Unless splices are called for, or otherwise noted or approved, conduit risers shall be
plumbed directly to road crossing conduits.
- Install insulating caps on all unused primary bushings.
- All “spare” conduits shall be capped at each end.
Owner / Developer Contact Info
officeATTN:
CITY OF RENTON
N/A
N/A
KEN SRILOFUNG 425-430-7247PHONE
CABLE TV
12090664 101191179
N/A 583....
N/A 584....
N/A
N/A
N/A 108169567
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
UG Expense
Removal
OH Expense 593270739
594170973
UG Expense
OH Expense
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:DUSTIN WELLER
206-379-4347
DUSTIN.WELLER@PSE.COM
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 1 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
LEGEND
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
EXISTING SECONDARY HANDHOLE
EXISTING CONDUCTOR AND/OR CONDUIT TO BE
REMOVED OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
PRIMARY METERING POINT
OR
OR
EXIST. 1Ø WIRE
EXIST. 3Ø WIRE
EXIST SECONDARY SERVICE LINE
EXISTING RIGHT OF WAY
EXISTING PROPERTY LINE
EXISTING CENTER LINE
EXISTING UG RISER
NEW UG RISER
PROPOSED SECONDARY HANDHOLE
PROPOSED PADMOUNT TRANSFORMER
PROPOSED TOTAL UNDERGROUND TRANSFORMER
No
No
Yes
Yes
"Joint Trench Coord Required"
"Vegetation Mgmnt Required"
N. LANIER 253-273-0625 5/8/26
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
POLE REMOVAL
MFP26001878
T98506
T98507
65T
T98505
ED
M
O
N
D
S
A
V
E
N
E
ED
M
O
N
D
S
A
V
E
N
E
T98506
T98507
65T
T9
8
5
0
5
31
8
6
5
0
-
1
6
6
8
4
8
10
1
1
9
1
1
7
9
R
1
SCALE: NONE
UNDERGROUND CIRCUIT MAP
OVERHEAD CIRCUIT MAP
SCALE: NONE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 2 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
MA
T
C
H
L
I
N
E
SE
E
T
H
I
S
P
A
G
E
X
X
MA
T
C
H
L
I
N
E
SE
E
T
H
I
S
P
A
G
E
X
X
JOB SITEJOB SITE
JOB SITE
SCALE: NONE
UNDERGROUND CIRCUIT MAP
N. LANIER 253-273-0625
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
2607 & 2609 NE 12TH ST
TPN: 7227801340
1" LATERAL 3/4" METER
ACCNT #003067
JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
2601 & 2603 NE 12TH ST
TPN: 7227801335
1" LATERAL 3/4" METER
ACCNT #003066
NA
TPN: 0923059102
NO METER
2527 NE 12TH ST
TPN: 0923059062
1" LATERAL 3/4"
METER ACCNT
#140025
1140 EDMONDS AVE NE
TPN: 0923059061
METER ON EDMONDS
1190 EDMONDS PL NE
TPN: 2270000020
1194 EDMONDS PL NE
TPN: 2270000010
TPN: 2309200060
2430 NE 12TH ST
TPN: 2309200010 JR HIGH SCHOOL
1416 EDMONDS AVE NE
TPN: 0423059048
50
A
8
00
A
9
10
00
A
11
00
A
12
00
A
13
00
A
14
1210
1204
2430
1194
1190 2607
2601
ED
M
O
N
D
S
A
V
E
N
E
ED
M
O
N
D
S
A
V
E
N
E
NE 12TH STNE 12TH ST
EXISTING
318652-166604
EXISTING
318652-166606
EXISTING
318648-166624
EXISTING
318648-166642
25kVA 120/240V
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ32104
BØ32105
CØ32106
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ32104
BØ32105
CØ32106
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ32107
BØ32108
CØ32109
HIG
13
HIG
13
60'
30'
30'
60'
60'
EXISTING
AØ43278
BØ43279
CØ43280
EXISTING
AØ13979
BØ13980
CØ13981
EXISTING
AØAGH975
BØAGH976
CØAGH977
EXISTING
AØ43943
BØ43944
CØ43945
EXISTING
AØ43934
BØ43935
CØ43936
EXISTING
AØ43937
BØ43938
CØ43939
EXISTING
AØAGH978
BØAGH979
CØAGH980
EXISTING
BØACG927
EXISTING
AØ42464
BØ42465
CØ42466
SITE PLAN
10
1
1
9
1
1
7
9
R
1
SCALE: 1" = 20'
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
4
O
F
9
A
A
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 3 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SITE NOTES
IP1 (INTERCEPT POINT 1)
-LOCATED 23' N OF NE 12TH ST C/L & 223'6" EAST OF EDMONDS AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
PV01 TO IP1
-LOWER POWER CONDUITS TO 36” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION FROM OTHER UTILITIES.
- RELOCATE POWER 4' NORTH OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
IP2 (INTERCEPT POINT 2)
-LOCATED 22' N OF NE 12TH ST C/L & 391' EAST OF EDMONDS AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
IP3 (INTERCEPT POINT 3)
-LOCATED 21'6" N OF NE 12TH ST C/L & 416' EAST OF EDMONDS AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
IP2-IP3
-LOWER POWER CONDUITS TO 54” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION FROM OTHER UTILITIES.
- RELOCATE POWER 4'6” NORTH OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Install Primary Bushings
Transformer
ID Numbers
(Company ID)
DESIGN INFORMATION
ENGINEER TO COMPLETE
AS BUILT INFORMATION
Foreman-Complete CONSTRUCTION UNITSLB
ELB10J
Per STD
6041.1000
DC
MID 7630600
V01 318648
166642 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS J-BUS
25 kVA TUT XFMR 120/240V EXISTING 6 -AG7762 REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x6
PV1 318648
166624 EXISTING PULL VAULT EXISTING PULL VAULT
N. LANIER 253-273-0625
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
1175 HARRINGTON PL NE2825 NE 12TH ST
TPN: 7227802045
2801 NE 12TH ST
TPN: 7227801680
1" METER ACCNT #003069
1174 HARRINGTON AVE NE
TPN: 7227801675
METER SERVICE ON HARRINGTON
1177 HARRINGTON AVE NE
TPN: 7227801355
METER SERVICE ON HARRINGTON
2613 & 2615 NE 12TH ST
TPN: 7227801345
1" LATERAL 3/4" METER
ACCNT #003069
NA
TPN: 7227801860
METER SERVICE ON HARRINGTON
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
2810 NE 12TH ST
TPN: 7227801685
EXISTING 3/4" METER ACCNT
2902 NE 12TH ST
TPN: 7227802040
2800 NE 12TH ST
TPN: 7227801690
EXISTING 3/4" METER
00
A
16
00
A
17
00
A
18
00
A
19
00
A
20
00
A
21
2804
2808
1208
1204
1200 2812
2800
2801
1170 1175
2613
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
NE 12TH ST
EXISTING
318648-166666
EXISTING
318643-166669
37.5kVA 120/240V
EXISTING
318648-166685
25kVA 120/240V
EXISTING
318642-166677
100kVA 120/240V
EXISTING
318648-166704
50kVA 120/240V
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ32110
BØ32111
CØ32112
EXISTING
BØ32113
EXISTING
BØ25972
EXISTING
AØ23657
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
BØ23647
HIG
13
HIG
13
50'
25'
25'
60'
60'
EXISTING
AØ23724
BØ23725
CØ23726
60'
NEW
318652-166678
SITE PLAN
10
1
1
9
1
1
7
9
R
1
SCALE: 1" = 20'
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
5
O
F
9
B
B
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 4 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SITE NOTES
IP4 (INTERCEPT POINT 4)
-LOCATED 24' N OF NE 12TH ST C/L & 109'6” WEST OF HARRINGTON AVE NE C/L
- INTERCEPT EXISTING 1-4” CONDUIT
IP4 TO V02
-INSTALL POWER CONDUITS TO 36” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION
FROM OTHER UTILITIES.
- RELOCATE POWER 6'4” NORTH OF EXISTING.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
IP5 (INTERCEPT POINT 5)
-LOCATED 21'6" N OF NE 12TH ST C/L & 246'9" EAST OF HARRINGTON AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
IP6 (INTERCEPT POINT 6)
-LOCATED 21'9" N OF NE 12TH ST C/L & 304'9" EAST OF HARRINGTON AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
IP5-IP6
-LOWER POWER CONDUITS TO 66” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION
FROM OTHER UTILITIES.
- RELOCATE POWER 13' SOUTH OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
- FOR THE ASBESTOS PIPE REMOVAL, THE CITY MUST BE NOTIFIED AT LEAST FIVE (5) WORKING DAYS PRIOR
TO THE PLANNED RELOCATIONS SO THAT THE APPROPRIATE TEAM CAN PLAN AND SCHEDULE THE
WORK ACCORDINGLY.
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Install Primary Bushings
Transformer
ID Numbers
(Company ID)
DESIGN INFORMATION
ENGINEER TO COMPLETE
AS BUILT INFORMATION
Foreman-Complete CONSTRUCTION UNITSLB
ELB10J
Per STD
6041.1000
DC
MID 7630600
J01 318648
166666 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE CREW TO INSTALL
CABLE NUMBERS.2-57x3
V02 318648
166685 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS J-BUS
25 kVA TUT XFMR 120/240V EXISTING 3 -AG7761 REPLACE ELBOW & CONDUCTORS. WIRE CREW TO INSTALL
CABLE NUMBERS.2-57x3
PV2 318648
166624
HH 5'x11'x5'
w/ ADJ A/S LID
MAT ID: 9996167
3-750kCMIL SPLICES
(6041.2000, SPL750)--
INSTALL NEW 5106 PULL VAULT (SHORT) & SPLICES
INSTALL NEW GRID NUMBER
(CAP ALL EMPTY CONDUIT)
INSTALL ANTI-SKID LID AND SET FLUSH WITH THE EXISTING
SIDEWALK
2-60A, 2-59x2, 2-58x3
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
3
O
F
9
A
A
N. LANIER 253-273-0625
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
FIRE STATION #12
1209 KIRKLAND AVE NE
TPN: 7227801450
4" DCDA W/ 3/4" METER
ACCNT #61583-001
1-1/2" IRR METER ACCNT
#61583-002
2" DOM METER ACCNT
#61583-000
1171 KIRKLAND AVE NE
TPN: 7227801406
975 HARRINGTON PL NE
TPN: 7227801405
1175 HARRINGTON PL NE
TPN: 3122000000
2902 NE 12TH ST
TPN: 7227802040 2908 NE 12TH ST
TPN: 7227801776
EXISTING 1-1/2" METER
ACCNT #3168-000
00
A
22
00
A
23
00
A
24
00
A
25
00
A
26
00
A
27
2908
1209
JE
F
F
E
R
S
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
P
L
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
EXISTING
318650-166734
150kVA 120/208V
EXISTING
318648-166735
EXISTING
318641-166736
EXISTING
318647-166745
167kVA 120/140V
EXISTING
318656-166757
X3310, 100T
EXISTING
318648-166756
EXISTING
318641-166756
U86912DA
EXISTING
318642-166756
U86913DA
EXISTING
318641-166758
EXISTING
318642-166758
EXISTING
318650-166771
U1925DA
EXISTING
318649-166772
25kVA 120/240V
EXISTING
318649-166771
EXISTING
318648-166782
EXISTING
AØ23727
BØ23728
CØ23729
EXISTING
AØ18258
BØ18259
CØ18260
EXISTING
AØ43940
BØ43941
CØ43942
EXISTING
AØ32119
BØ32120
CØ32121
EXISTING
AØ30484
BØ30485
CØ30486
EXISTING
AØUNK
EXISTING
AØEHN539
BØEHN540
CØEHN541
EXISTING
AØACT564
BØACT565
CØACT566
EXISTING
AØEIX352
BØEIX353
CØEIX354
EXISTING
AØ32128
BØ32129
CØ32130
EXISTING
AØEJN738
BØEJN739
CØEJN740
EXISTING
AØEGH000
BØEGH001
CØEGH002
EXISTING
AØ32131
BØ32132
CØ32133
EXISTING
AØ18035
BØ18036
CØ18037
EXISTING
AØACA994
BØACA995
CØACA996
EXISTING
AØACA997
EXISTING
AØACT561
BØACT562
CØACT563
HIG
13
HIG
13
NE 12TH ST
NE 12TH ST
50'
25'
25'
50'
50'
60'
50'
3-PHASE FEEDER PASSES
THROUGH JBOX IN 6" CONDUIT
LOWER ELEVATION TO 36"
FROM TOP OF CONDUIT
SITE PLAN
10
1
1
9
1
1
7
9
R
1
SCALE: 1" = 20'
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
6
O
F
9
C
C
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 5 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SITE NOTES
J02-J03
-INSTALL POWER CONDUITS IN PLACE TO 36” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 10” VERTICAL SEPARATION
FROM EXISTING 8” CI WATER & ABANDONED 8” AC WATER.
- MAINTAIN AT LEAST 12” VERTICAL SEPARATION FROM OTHER UTILITIES.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
IP7 (INTERCEPT POINT 7)
-LOCATED 19' N OF NE 12TH ST C/L & 199'6” WEST OF JEFFERSON AVE NE C/L
- INTERCEPT EXISTING 1-6” CONDUIT
IP8 (INTERCEPT POINT 8)
-LOCATED 20'6" N OF NE 12TH ST C/L & 132' WEST OF JEFFERSON AVE NE C/L
- INTERCEPT EXISTING 1-4” AND 1-6” CONDUIT
IP7-IP8
-INSTALL POWER CONDUITS TO 70” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION FROM OTHER
UTILITIES.
- RELOCATE POWER 13' SOUTH OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
- FOR THE ASBESTOS PIPE REMOVAL, THE CITY MUST BE NOTIFIED AT LEAST FIVE (5) WORKING DAYS PRIOR TO THE PLANNED
RELOCATIONS SO THAT THE APPROPRIATE TEAM CAN PLAN AND SCHEDULE THE WORK ACCORDINGLY.
J02-IP8
-INSTALL POWER CONDUITS TO 70” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION FROM OTHER
UTILITIES.
- RELOCATE POWER 21' SOUTH OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Install Primary Bushings
Transformer
ID Numbers
(Company ID)
DESIGN INFORMATION
ENGINEER TO COMPLETE
AS BUILT INFORMATION
Foreman-Complete CONSTRUCTION UNITSLB
ELB10J
Per STD
6041.1000
DC
MID 7630600
J02 318648
166735 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 9 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x9
J03 318641
166736 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
J04 318648
166756 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
SW1 318641
166756 EXISTING VISTA SWITCH EXISTING VISTA 422 3 -
REMOVE 3Ø FEEDER TO REROUTE CONDUIT.
PULL NEW FEEDER THROUGH CONDUIT AND
INSTALL NEW ELBOWS. WIRE CREW TO
INSTALL CABLE NUMBERS.
2-58x1
SW2 318650
166771 EXISTING VISTA SWITCH EXISTING VISTA 422 3 -
REMOVE 3Ø FEEDER TO REROUTE CONDUIT.
PULL NEW FEEDER THROUGH CONDUIT AND
INSTALL NEW ELBOWS. WIRE CREW TO
INSTALL CABLE NUMBERS.
2-58x1
1 2 3 4
AØ
A
C
T
5
6
4
1 2 3 4
Cable
Connection
Side
Operator
Side
SW2
Vista 422
2-600 Amp
2-200 Amp 1Ø
T
r
i
p
15
0
E
1Ø
T
r
i
p
15
0
E
BØ
A
C
T
5
6
5
CØ
A
C
T
5
6
6
AØ
E
J
N
7
3
8
BØ
E
J
N
7
3
9
CØ
E
J
N
7
4
0
AØ
A
C
T
5
6
1
BØ
A
C
T
5
6
2
CØ
A
X
T
5
6
3
AØ
E
H
G
0
0
0
AØ
E
K
H
6
0
0
BØ
E
H
G
0
0
1
BØ
E
K
H
6
0
1
CØ
E
H
G
0
0
2
CØ
E
K
H
6
0
2
N. LANIER 253-273-0625
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
4
O
F
9
B
B
1 2 3 4
AØ
4
3
9
4
0
A
Ø
E
K
H
3
3
4
1 2 3 4
Cable
Connection
Side
Operator
Side
SW1
Vista 422
2-600 Amp
2-200 Amp 1Ø
T
r
i
p
15
0
E
1Ø
T
r
i
p
15
0
E
BØ
4
3
9
4
1
B
Ø
E
K
H
3
3
5
CØ
4
3
9
4
2
C
Ø
E
K
H
3
3
6
AØ
E
J
N
7
3
2
BØ
E
J
N
7
3
3
CØ
E
J
N
7
3
4
AØ
E
J
N
7
3
5
BØ
E
J
N
7
3
6
CØ
E
J
N
7
3
7
AØ
(
O
P
E
N
)
BØ
(
O
P
E
N
)
CØ
(
O
P
E
N
)
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
NA
TPN: 7227900018
3011 NE SUNSET BLVD
TPN: 7227900019
METER SERVICE ON NE
SUNSET BLVD
NA
TPN: 722790UNKN
3218 NE 12TH ST
TPN: 0423059182
1-1/2" METER
ACCNT #17721-00
3123 NE SUNSET BLVD
TPN: 0423059155
1" METER ACCNT
#157203-000
1" IRR METER ACCNT
#57203
3116 NE SUNSET BLVD
TPN: 0423059095
3/4" IRR METER ACCNT
#19835-000
3002 NE SUNSET BLVD
TPN: 7227800285
METER SERVICE ON
NE SUNSET BLVD
3116 SUNSET BLVD NE
TPN: 0423059095
3002 NE SUNSET BLVD
TPN: 7227800285
00
A
28
00
A
29
00
A
30
00
A
31
00
A
32
00
A
33
3116
3002
3155
3218
3123
NE 12TH ST
NE
S
U
N
S
E
T
B
L
V
D
NE
S
U
N
S
E
T
B
L
V
D
J
EXISTING
318648-166790
EXISTING
318649-166787
X1506, 65T
EXISTING
318644-166805
50kVA 120/240V
EXISTING
318641-166821
3x15kVA 277/480V
Wye/Wye
EXISTING
318638-166846
150kVA 120/208V
EXISTING
318644-166833
EXISTING
318650-166340
45kVA 277/480V
318642-166834
X7554 T98506 (S)
X429 T98507 (N)
100T 65T
EXISTING
318644-166846
EXISTING
AØ18038
BØ18039
CØ18040
EXISTING
AØAEB811
BØAEB812
CØAEB813
EXISTING
AØEGH000
BØEGH001
CØEGH002
EXISTING
AØADW139
BØADW140
CØADW141
EXISTING
AØEGH000
BØEGH001
CØEGH002
EXISTING
AØACA986
BØACA987
CØACA988
EXISTING
AØAEB807
BØAEB808
CØAEB809
336.4 MCMACSR CB
A
CBA
HIG
13
HIG
13
HIG
13
HIG
13
EXISTING
318660-166830
LY
N
N
W
O
O
D
A
V
E
N
E
60'
30'
30'
50'
100'
88'
50'
EXISTING
318655-166831
300kVA 120/208V
EXISTING 1/0
AØAEB814
BØAEB815
CØAEB816
EXISTING 1/0
AØAEB820
BØAEB821
CØAEB822
EXISTING 1/0
AØAEB817
BØAEB818
CØAEB819
318649-166825
33
6
.
4
M
C
M
A
C
S
R
J
SITE PLAN
10
1
1
9
1
1
7
9
R
1
SCALE: 1" = 20'
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
7
O
F
9
D
D
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 6 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SITE NOTES
IP9 (INTERCEPT POINT 9)
-LOCATED 91'6" N OF NE 12TH ST C/L & 35' SOUTHEAST OF NE SUNSET BLVD C/L
-INTERCEPT EXISTING 4” CONDUITS
V03-IP9
-LOWER POWER CONDUITS TO 36” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12” SEPARATION FROM OTHER UTILITIES.
-RELOCATE POWER 36' EAST OF EXISTING TO ENSURE 5' HORIZONTAL SEPARATION FROM CATCH BASIN.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
IP11 (INTERCEPT POINT 11)
-LOCATED 20'6" N OF NE 12TH ST C/L & 20'9" EAST OF NE SUNSET BLVD C/L
-INTERCEPT EXISTING 1-4” AND 1-6” CONDUITS
IP12 (INTERCEPT POINT 12)
-LOCATED 20'6" N OF NE 12TH ST C/L & 50'3" EAST OF NE SUNSET BLVD C/L
-INTERCEPT EXISTING 1-4” AND 1-6” CONDUITS
IP11-IP12
-LOWER POWER CONDUITS TO 95" BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 12" SEPARATION FROM OTHER UTILITIES
-RELOCATE POWER 3' SOUTH OF EXISTING.
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION.
P02 318644-166846 (1975, 45' CL-2,∠0⁰, AVG SPAN 80')
-EXISTING POLE TO REMAIN
P03 318642-166834 (1970, 40' CL2)
-REPLACE EXISTING POLE WITH 45' CL-1 POLE (6010.1000, PD451)2-23
INSTALL POLE 1' EAST OF EXISTING POLE
-INSTALL 3Ø DEADEND 1/0 & LARGER (6033.1042, DE3310)
INSTALL ARM 8P DOUBLE HD 9', 12KV (MID: ARD2H09)
-INSTALL 3Ø 200A & 600A DOUBLE TERM (6043.1022, TSU6D31)2-57x3, 2-58
FOR 600A FEEDER TERM: INSTALL NEW SB CUTOUT STYLE SWITCHES
INSTALL (3) SB C/O COVERS (MID: 9947360)
INSTALL (3) LA COVERS (MID: 9998115)
INSTALL SW BD #T98506
ACTUAL 3Ø____UG PRI ADDED L=____BATCH YEAR____
ACTUAL TRENCH L=____'
FOR 200A 1/0 TERM: INSTALL NEW LI C/O'S & 65T FUSE (MID: 3412600)
INSTALL (3) LI C/O COVERS (MID: 9947626)
INSTALL (3) LA COVERS (MID: 9998115)
INSTALL SW BD #T98507
ACTUAL 3Ø____UG PRI ADDED L=____BATCH YEAR____
ACTUAL TRENCH L=____'
-INSTALL 6'' PRI RISER (6042.1000, RIS6CSS)2-44
-INSTALL 4'' PRI RISER (6042.1000, RIS4CSS)2-45
-INSTALL SPAN GUYS EAST TOWARDS P04 1-8E
INSTALL 7/16" DISTRIBUTION SPAN GUY (6013.0170, GYD7OW)
INSTALL 3/8" NEUTRAL SPAN GUY (6013.0170, GYD3OW)
-TOP POLE 1' ABOVE COMMS, REMOVE STUB AFTER COMMS TRANSFER 2-129
P04 318649-166825
-INSTALL NEW 35' CL-2 STUB POLE (MID: 8973502)2-23
INSTALL POLE 7' WEST OF DRIVEWAY
-INSTALL 24" PLATE ANCHOR LL=25' W (MINIMUM), BACKFILL______(6012.1000, ANDP24)2-10A
INSTALL BETWEEN TWO WEST-MOST TREES EAST OF INTERSECTION
INSTALL DBL 7/16" DOWN GUY TO ANCHOR (W) (LL=25')(6013.0100, GYDD71A)
-INSTALL NEW GRID NUMBERS 318649-166825
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Install Primary Bushings
Transformer
ID Numbers
(Company ID)
DESIGN INFORMATION
ENGINEER TO COMPLETE
AS BUILT INFORMATION
Foreman-Complete CONSTRUCTION UNITSLB
ELB10J
Per STD
6041.1000
DC
MID 7630600
J05 318660
166830 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
J06 318644
166833 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS J-BUS
EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
V03 318641
166821 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS J-BUS
3X 15 kVA TUT XFMR 277/480V EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
V07 318644
166805 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS J-BUS
50 kVA TUT XFMR 120/240V EXISTING 3 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x3
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
5
O
F
9
C
C
N. LANIER 253-273-0625
UNITS OF PROPERTY
INSTALL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARM - DISTRIBUTION
CROSSARM - TRANSMISSION
UNITS OF PROPERTY
REMOVAL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARMS - DISTRIBUTION
CROSSARMS - TRANSMISSION
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P03 318642-166834 45 1
P04 318649-166825 35 2 SET POLE 7' WEST OF P03
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P03 318642-166834 40 2 1970
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
3233 NE 12TH ST
TPN: 7801300000
METER SERVICES ON
LYNNWOOD
00
A
34
00
A
35
3232
MO
N
R
O
E
A
V
E
N
E
336.4 MCMACSR
EXISTING
CØAEP270
EXISTING
BØAEP269
EXISTING
AØAEP268
HIG
13
EXISTING
318631-166853
100kVA 120/240V
EXISTING
318623-166853
50kVA 120/240V
EXISTING
318608-166853
100kVA 120/240V
60'
30'
30'
NE 12TH ST
EXISTING
318643-166853
37.5kVA 120/240V
X11078, 100T
318650-166848
37.5kVA 120/240V
T98505
100T
SITE PLAN
10
1
1
9
1
1
7
9
R
1
SCALE: 1" = 20'
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 7 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SITE NOTES
IP10 (INTERCEPT POINT 10)
-LOCATED 18'6" S OF NE 12TH ST C/L AND 119'3" E OF LYNWOOD AVE NE C/L
- INTERCEPT EXISTING 3-2” CONDUITS
P01A-IP10
-LOWER POWER CONDUITS TO 28” BELOW GRADE MINIMUM, TOP OF CONDUIT, TO ENSURE 11” SEPARATION FROM
EXISTING 10” CI WATER AND AT LEAST 12” SEPARATION FROM OTHER UTILITIES.
RELOCATE POWER 3' WEST OF EXISTING
UTILIZE SCHEDULE 80 WITH 90°, 45°, 22°, OR 11° BENDS TO ACHIEVE REQUIRED ELEVATION
P01 318643-166853 (1960, 40', CL1, ∠0⁰, 120' AVE SPAN)
-REMOVE EXISTING 40' CL1 POLE
P01A 318650-166848 (2026, 40', CL1, ∠0⁰)
-INSTALL NEW 40' CL1 POLE (6010.1000, PD451)2-23
SET POLE 25' WEST OF EXISTING P01
-INSTALL 3Ø TANGENT PTP (6033.1012, TAN313)
INSTALL 8P SINGLE STD 9' ARM (MID: ARD1S09)
-INSTALL 3Ø 200A TERM, WITH TRANSFORMER (6043.1003, TSU3LTW)2-57x3, 2-24
INSTALL LB C/O'S & 100T FUSES (MID: 3412500)
INSTALL (3) LI C/O COVERS (MID: 9999109)
INSTALL (3) LA COVERS (MID: 9998115)
ACTUAL 3Ø____UG PRI ADDED L=____ BATCH YEAR____
ACTUAL TRENCH L=____'
INSTALL SW BD #T98505
-XFER EXIST 37.5kVA 7-120/240V XFMR (6025.1000, TRFPXF)2-24
REPL LB C/O, 15T FUSE, & STIRRUP; TAP BØ (MID: 3412300)
INSTALL LB C/O COVER (MID: 9999530)
INSTALL XFMR BUSHING COVER (MID: 9996101)
-INSTALL (3) 2'' PRI RISER (6042.1000, RIS2CSS)2-45
-INSTALL BRIDLE SERVICE 25' EAST OF POLE, ATTACHING TO NEUTRAL (6024.1000, BSTPX)
-XFER OH SVC, ____TPLX (N) SERVING ADDRESS 3224 NE 12TH ST RENTON, 98056, ACTUAL____'
-XFER OH SEC,____TPLX (W), ATTACHED TO P02 (SPAN=90') ACTUAL____'
-INSTALL NEW GRID NUMBER 318650-166848
-TOP POLE 1' ABOVE COMMS, REMOVE STUB AFTER COMMS TRANSFER 2-129
Vault & Equipment Table
Site Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Install Primary Bushings
Transformer
ID Numbers
(Company ID)
DESIGN INFORMATION
ENGINEER TO COMPLETE
AS BUILT INFORMATION
Foreman-Complete CONSTRUCTION UNITSLB
ELB10J
Per STD
6041.1000
DC
MID 7630600
V04 318631
166853 EXISTING PM 100 kVA PM XFMR 120/240V EXISTING 1 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x1
V05 318623
166853 EXISTING PM 50 kVA PM XFMR 120/240V EXISTING 1 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x1
V06 318608
166853 EXISTING PM 100 kVA PM XFMR 120/240V EXISTING 1 -REPLACE ELBOW & CONDUCTORS. WIRE
CREW TO INSTALL CABLE NUMBERS.2-57x1
MA
T
C
H
L
I
N
E
SE
E
P
A
G
E
6
O
F
9
D
D
N. LANIER 253-273-0625
UNITS OF PROPERTY
INSTALL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARM - DISTRIBUTION
CROSSARM - TRANSMISSION
UNITS OF PROPERTY
REMOVAL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARMS - DISTRIBUTION
CROSSARMS - TRANSMISSION
New pole at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER TRANSFER
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P01A
318650-166848
37.5 kVA
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01A 318650-166848 40 1 SET POLE 25" WEST OF P01
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P01 318643-166853 40 1 1960
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
NE
S
U
N
S
E
T
R
D
LY
N
N
W
O
O
D
A
V
E
N
E
EXISTING
318641-166756
U86912DA EXISTING
318642-166756
U86913DA
EXISTING
318641-166758
EXISTING
318656-166757
X3310, 100T
EXISTING
318648-166756
EXISTING
318650-166771
U1925DA
EXISTING
318641-166821
3x15kVA 277/480V
Wye/Wye
EXISTING
318638-166846
150kVA 120/208V
EXISTING
318644-166833
EXISTING
318660-166830
EXISTING
318655-166831
300kVA 120/208V
EXISTING
318663-166824
EXISTING
318676-166831
25kVA 120/240V
EXISTING
318651-166604
U317
EXISTING
318652-166606
EXISTING
318648-166624
EXISTING
318648-166642
25kVA 120/240V
EXISTING
318648-166666
EXISTING
318643-166669
37.5kVA 120/240V
EXISTING
318648-166685
25kVA 120/240V
NEW
318652-166678
EXISTING
318622-166681
X5116
EXISTING
318659-166687
T77560, 65T
EXISTING
318648-166735
EXISTING
318641-166736
EXISTING
318638-166736
225kVA 120/208V
NEW 1-6"
NEW 1-4"
EXIST 1-6"
EXIST 1-4"
EXIST 1-6"
EXIST 1-4"
NEW 1-6"
NEW 1-4"
NEW 1-4"
NEW 1-6"
NEW 1-4"
EXIST 1-6"
EXIST 1-4"
NEW 1-6"
NEW 1-4"
NEW 1-4"
NEW 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
MO
N
R
O
E
A
V
E
N
E
NEW 1-2"
EXIST 1-2"
NEW 1-2"
NEW 1-2"
EXIST 1-2"
EXIST 1-2"
EXIST 1-2"EXIST 1-4"
EXIST 1-2"
EXIST 1-4"
EXIST 1-4"
EXIST 1-4"
EXIST 1-6"
EXIST 1-6"
EXISTING
318648-166704
50kVA 120/240V
EXIST 1-2"
EXISTING
318647-166745
167kVA 120/140V
EXIST 1-2"
EXISTING
318631-166853
100kVA 120/240V
EXISTING
318623-166853
50kVA 120/240V
EXISTING
318608-166853
100kVA 120/240V
EXIST 1-6"EXIST 1-4"
NEW
318642-166834
T98506
T98507
65T
EXIST 1-6"
NEW 1-4"
EXISTING
318644-166805
50 kVA 120/240V
NEW 1-6"
EXIST 1-4"
NEW
318650-166848
T98505
100T
CONDUIT DIAGRAM
10
1
1
9
1
1
7
9
R
1
SCALE: NONE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 8 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N. LANIER 253-273-0625
2-35 x 270' & 2-36 x 745'
2-54 x 1050', 2-55 x 2340', & 2-56 x 2275'
2-49 x 645' & 2-63 x 287 yd
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
HA
R
R
I
N
G
T
O
N
A
V
E
N
E
JE
F
F
E
R
S
O
N
A
V
E
N
E
KI
R
K
L
A
N
D
A
V
E
N
E
NE
S
U
N
S
E
T
R
D
MO
N
R
O
E
A
V
E
N
E
LY
N
N
W
O
O
D
A
V
E
N
E
REMOVE 750MCM
AØ43940
BØ43941
CØ43942
REMOVE 1/0
AØ32104
BØ32105
CØ32106
REMOVE 1/0
AØ32107
BØ32108
CØ32109
REMOVE 1/0
AØ32110
BØ32111
CØ32112
REMOVE 1/0
AØ32116
BØ32117
CØ32118
NEW 750MCM
AØEKH334
BØEKH335
CØEKH336
NEW 1/0 AL JKT
AØEKH337
BØEKH338
CØEKH339
NEW 1/0 AL JKT
AØEKH340
BØEKH341
CØEKH342
NEW 1/0 AL JKT
AØEKH343
BØEKH344
CØEKH345
NEW 1/0 AL JKT
AØEKH346
BØEKH347
CØEKH348
NEW 1/0 AL JKT
AØEKH402
BØEKH403
CØEKH404 NEW 1/0 AL JKT
AØEKH405
BØEKH406
CØEKH407
NEW 1/0 AL JKT
CØEKH410
NEW 1/0 AL JKT
BØEKH409
NEW 1/0 AL JKT
AØEKH408
REMOVE 1/0
AØ32116
BØ32117
CØ32118
NEW 1/0 AL JKT
AØEKH349
BØEKH400
CØEKH401
REMOVE 1/0
AØAEB807
BØAEB808
CØAEB809
REMOVE 1/0
CØAEB270
REMOVE 1/0
BØAEB269
REMOVE 1/0
AØAEB268
NEW 750MCM
AØEKH334
BØEKH335
CØEKH336
EXISTING
318641-166756
U86912DA EXISTING
318642-166756
U86913DA
EXISTING
318641-166758
EXISTING 1/0
AØEJN735
BØEJN736
CØEJN737
EXISTING 1/0
AØEJN732
BØEJN733
CØEJN734
EXISTING
318656-166757
X3310, 100T
EXISTING
318648-166756
EXISTING
318650-166771
U1925DA
EXISTING
AØEHN539
BØEHN540
CØEHN541
EXISTING
AØACT564
BØACT565
CØACT566
REMOVE 1/0
AØ32119
BØ32120
CØ32121
EXISTING
318641-166821
3x15kVA 277/480V
Wye/Wye
EXISTING
318638-166846
150kVA 120/208V
EXISTING 1/0
AØAEB804
BØAEB805
CØAEB806
EXISTING 1/0
AØAEB801
BØAEB802
CØAEB803
EXISTING 1/0
AØACA986
BØACA987
CØACA988
EXISTING
318660-166830
EXISTING
318655-166831
300kVA 120/208V
EXISTING
318663-166824
EXISTING
318676-166831
25kVA 120/240V
EXISTING 1/0
AØAEB814
BØAEB815
CØAEB816
EXISTING 1/0
AØAEB820
BØAEB821
CØAEB822
EXISTING 1/0
AØAEB817
BØAEB818
CØAEB819
EXISTING
318651-166604
U317
EXISTING 750MCM
AØ43940
BØ43941
CØ43942
RE-LABEL AT SW U317 TO
AØEKH334
BØEKH335
CØEKH336
EXISTING 1/0
AØ32104
BØ32105
CØ32106
RE-LABEL AT J-BOX TO
AØEKH337
BØEKH338
CØEKH339
EXISTING
318652-166606
EXISTING
318648-166624
EXISTING
318648-166642
25kVA 120/240V
EXISTING 1/0
AØUNK
EXISTING
318648-166666
EXISTING 1/0
BØ32113
EXISTING
318643-166669
37.5kVA 120/240V
EXISTING
318648-166685
25kVA 120/240V
NEW
318652-166678
EXISTING 1/0
AØUNK
EXISTING
318622-166681
X5116
EXISTING
318659-166687
T77560, 65T
EXISTING 1/0
AØ23724
BØ23725
CØ23726
EXISTING 1/0
AØ23657
EXISTING
318648-166735
EXISTING
318641-166736
EXISTING 1/0
AØ30484
BØ30485
CØ30486
EXISTING
318638-166736
225kVA 120/208V
EXISTING
318631-166853
100kVA 120/240V
EXISTING
318623-166853
50kVA 120/240V
EXISTING
318608-166853
100kVA 120/240V
EXISTING
318648-166704
50kVA 120/240V EXISTING
318647-166745
167kVA 120/140V
EXISTING 1/0
AØUNK
EXISTING 1/0
BØ23647
EXISTING
318644-166833
EXISTING
318644-166805
50kVA 120/240V
NEW 750MCM
AØEKH600
BØEKH601
CØEKH602
NEW 1/0 AL JKT
AØEKH422
BØEKH423
CØEKH424
REMOVE 1/0
AØADW139
BØADW140
CØADW141
REMOVE 750MCM
AØEHG000
BØEHG001
CØEHG002
EXISTING 1/0
AØADW142
BØADW143
CØAEB800
NEW
318642-166834
T98506
T98507
65T
NEW
318650-166848
T98505
100T
CABLE DIAGRAM
10
1
1
9
1
1
7
9
R
1
SCALE: NONE
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
DUSTIN WELLER 206-379-4347 5/8/26
ARIELLE JOVEN 702-482-5886 5/8/26
N/A N/A N/A
J. YATES -5/8/26
N/A RENTON
HIGHLANDS RESERVOIR WATER MAIN
UG POWER RELOCATION
1140 EDMONDS AVE NE, RENTON, WA 98056
N/A N/A
N/A 101191179
AS NOTED 9 / 9
KING N/A N/A CSPSKEPI
S04 T23N R05E N/A N/A
2305E015,016 2305E040 2305E015,016 HIG-13
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
LSG317
PULL VAULT CABLE ENTRY DETAIL
SCALE: NONE
1-2", 1-4", or 1-6" Power Conduits
Excavated Dirt Pile
Final Grade
24" Min
6" Min Sand Cover Over Power Conduits
36"
Min
Cover
(Typ.)48"
Max
(Typ.)
Backfill
(No rocks over 6" diameter)
NOTE: Install 12" shading
if the backfill contains rocks
greater than 10" dia.
3" Sand Bedding
VEHICLE
ACCESS
SIDE
6"4"
12" Typical
(6" Min)
NOT TO SCALE
TRENCH EXCAVATION DETAIL
Excavation - 31 cubic yards
SIDE VIEW
5'-4"
Crushed
6"
Rock
TOP VIEW
10'
16'
5'-0"
8"
6'-2"
Cover
6,540 lbs
11,600 lbs
Base
5'-10"
11'-4"
Final Grade
Adjustable Cover
(See NOTE Below)
2"
6,140 lbs
8" Riser
Three 3' Sq Diamond
or Anti-SkidPlate Doors
Adjustable Bolts (4)
5106 PULL VAULT EXCAVATION DETAIL
SCALE: NONE MID # 7906630 OR 9996167
N. LANIER 253-273-0625
2"
4/30/26 A. JOVEN UPDATED SCOPE AND SITE NOTES
5/8/26
MFP26001878