Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CO6 - Sheet C7.5_20260528_Revision_Approved
8''W 8''W10''W PRD 8''W PRD 8''W PRD 8''W 8''W 8''W 12 ' ' W 12 ' ' W 1 2 ' ' W P R D 12''W PRD 12''W P R D 12''W P R D 12''W 12''W 12''W 12''W 12''W 12''W 12''W 16 ' ' W 16 ' ' W 16 ' ' W 6' ' W P R D 1. 5 ' ' W - P R D BOEING FUEL FARM BUILDING BOEING FUEL FARM SECURED AREA. SEE NOTE 4, THIS SHEET 0+ 0 0 BP: 0+00.00 0+0 0 / / / / / / / / / / / / / / / ////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / EX WATER/FIRE WATERLINE (PER SURVEY) EX WATER/FIRE WATERLINE (PER RCD DWG) EX ISOLATION VALVE EX WATER MANHOLE EX BELOW GRADE FIRE HYDRANT EX ABOVE GRADE FIRE HYDRANT EX WATER METER ABANDON EX FIRE WATERLINE PROPOSED FIRE WATERLINE PROPOSED CAP PROPOSED GATE VALVE PROPOSED ABOVE GRADE FIRE HYDRANT PROPOSED TAPPING TEE PROPOSED THRUST BLOCK X''W X''W PRD /////////// X''W 1 7/9/2025 JA SMT CONFORMED SET 2 5/28/2026 JA SMT CO #6 JULY 2025 35022.008.02 1" = 40' DSW JA SMT WATER IMPROVEMENTS PLAN 5 OF 5 C7.5 91 OF 116 R MBX KEYPLAN © 2025 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS - PHASE Pl o t t e d B y : Ag u d e l o , J u l i a n S h e e t S e t : RN T _ T A X I W A Y A R E H A B L a y o u t : C7 . 5 Ma y 2 8 , 2 0 2 6 0 1 : 3 4 : 3 7 p m K: \ S E A _ P u b l i c S e c t o r \ 0 9 0 1 1 9 0 0 0 . 3 - R e n t o n A i r p o r t - T a x i w a y A \ 0 8 C A D D \ P l a n S h e e t s \ P h a s e 1 - 2 0 2 4 B i d P a c k a g e \ C 7 . 0 - P h a s e 1 W A T R - 0 9 0 1 1 9 0 0 0 . d w g WT R - 2 7 - 4 3 1 3 LU A 2 4 - 0 0 0 2 0 8 C2 4 0 0 3 6 8 1 EX CITY OF RENTON 12" DI W EX CITY OF RENTON HYDRANT HYD-N-00233 EX CITY OF RENTON HYDRANT HYD-N-00497 EX CITY OF RENTON HYDRANT HYD-N-00216 EX ABOVE GRADE FIRE HYDRANT H328B AND BOLLARDS (TYP 4) EX ABOVE GRADE FIRE HYDRANT H320C 1.CLOSING OF VALVES & REMOVAL OF FIRE HYDRANTS TO BE COORDINATED AND SCHEDULED WITH BOEING FIRE DEPARTMENT, RENTON AIRPORT & CITY OF RENTON WATER DEPARTMENT PER SPECIFICATIONS. 2.NOT USED 3.SEE DETAIL 300.0, SHEET C7.6 FOR CITY OF RENTON GENERAL WATER PLAN NOTES. 4.BOEING'S FUEL FARM IS A SECURED AREA WITH RESTRICTED ACCESS. CONTRACTOR WILL NOT HAVE ACCESS TO EXISTING FIRE WATERLINE WITHIN THE FUEL FARM AREA. 5.EXISTING FIRE WATERLINE DIGITIZED FROM RECORD DRAWING. LOCATIONS ARE APPROXIMATE AND HAVE NOT BEEN CONFIRMED THROUGH UTILITY LOCATES. 6.NOT USED 7.SAWCUT AND REMOVE EXISTING 8" TO 10" THICK REINFORCED CONCRETE PANELS UP TO THE EXISTING NORTHERN HMA PAVEMENT EDGE. EX BOEING 6" DI W FUEL FARM BUILDING FIRE SERVICE SEE NOTE 5, THIS SHEET EX BOEING 1.5" DI W FUEL FARM BUILDING WATER SERVICE SEE NOTE 5, THIS SHEET EX 12" DI W SEE NOTE 5, THIS SHEET EX 8" DI W SEE NOTE 5, THIS SHEET PROTECT EX WATER METER AND SERVICE MATCHLINE, SEE SHEET C7.2 MA T C H L I N E , S E E S H E E T C7 . 2 LEGEND LEGEND CONT. 0 SCALE 1" = 20 40 20' N MA T C H L I N E , S E E S H E E T C7 . 2 PROTECT EX 7.5' TALL SECURITY FENCE PROTECT EX CITY OF RENTON 16" WATER MAIN W. PERIMETE R R D . W-431305 428 LF 111 LF 29 LF FIRE WATERLINE NOTES NOTES RESTORATION NOTES 1 REMOVE & RESTORE CONC W/ HMA PER CITY OF RENTON STD PLAN 220.20, SHT C7.6. SEE NOTE 7, THIS SHEET. RESTORE DISTURBED CONC PER CITY OF RENTON STD PLAN 102, SHEET C7.6. ABANDON EX FIRE WATERLINE IN PLACE, FILL W/ CLSM PER P-153. EX VALVE TO BE ABANDONED IN PLACE. CONTRACTOR TO OPEN VALVE, REMOVE OPERATING NUT & VALVE CAN. LOCATIONS WITHIN PAVED AREAS TO BE BACKFILLED WITH CLSM, LOCATIONS OUTSIDE OF PAVED AREAS TO BE BACKFILLED PER P-209 OR SUITABLE NATIVE MATERIAL, AS APPROVED BY THE RPR. DEMOLISH & REMOVE EX ABOVE GRADE FIRE HYDRANT & GATE VALVE. REMOVE EX HYDRANT TO 90° BEND & CAP FIRE WATERLINE. BACKFILL WITH CLSM & RESTORE SURFACE. DEMOLISH & REMOVE EX BOLLARDS. 2 2 2 2 5/28/2026 DEVELOPMENT ENGINEERING yqi 05/29/2026