Loading...
HomeMy WebLinkAboutzR-4283setJ ry- 0 LJJ O ry- LLJ TAX PARCEL 112305-9087 736 NILE AVE NE a 0 W ITE LANE ° STRIPE TAX PARCEL 638930-0120 TRACT A I I TAX PARCEL 638930-0110 I 5718 NE 7TH PL LOT 11 I FOUND ° MONUMENT I IN CASE 11113 ~ o FOUND OLYMPUS VILLA I MONUMENT VOL. 260, PG. 26 I 3 IN CASE � a 0 ~ cW W W W W W W — � a � 3 1 FOUND MONUMENT � N IN CASE x SD SD ,SD . SD. Sp SD --- .SD SD. SD SD W W W W . W W 3 S° NE 7T N ADA � _ --- .— _ H P� W W W W W W W W— aR A M P0 0 N F f1° °s s ToP eAOK of C(j .N . . . . . . . . . . . . . . . . . NE 7TH PLACE 3 Q P P —. .. �_° d:.: ,. S v1l�,� S SD SD SD S ° P P In ° 3 W x 71.97' P P. a`CDNCR) T,E.oSIDEWAjK N . I P P ° ° P ./y �8 P P P cv 3 W Z o.I° FOUND F ° W REBAR & CAP F 4 LS #32441 WESTON HEIGHTS NORTH 3 Q 0.2' E. OF LINE SHORT PLAT ° I VOL. 373, PG. 69 G G <r °LILI 36:5'0 1 I LOT 1 z 3 I I 9,214 SF TAX PARCEL 112305-9130 a I 5717 NE 7TH PL , o a. S LOT 2 POWER POLE W 1. a R 00 L�13� I A WITH LIGHT, A a, Q TRANSFORMER LOT 3 & 2 PWR DROPS z a , 10306 SF J (/ I LOT 2 W 4_4 s6 10,165 SF / CONC... ° 3 DRIVE d 3 As L�. / 15.00' 88.50' BSBL 75.00' R ------------ FLOW 3 L I °�. LINE a O Lj s a STORMWATER TRACT I TAX PARCEL TRA112g 05-9136 3 � a 2,312 SF 0 ' o W 1. I A ° 69.99' 70.26' 27. ' 0 22" APL 0 26" APL PPL — 3 TAX PARCEL 112305-9135 �8 — �--- TRACT A ° FOUND °�'----- N REBAR & CAP T.IT a LS #32441 F. 0.2' E. & 0.1' S. OF CORNER 3G' FOUND REBAR & CAP WHITE LANE o STRIPE LS #32441 ° 0 0 0 : CITY OF RENTON DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT. CONDITIONS OF APPROVAL THE SIERRA HOMES SHORT PLAT, FILE NO. LUA22- 000427, SHPL- A, MOD, IS APPROVED AND IS SUBJECT TO THE FOLLOWING CONDITIONS. 1. THE APPLICANT SHALL OBTAIN A DEMOLITION PERMIT AND COMPLETE A FINAL INSPECTION FROM THE CITY FOR THE REMOVAL OF THE RESIDENCE AND GARAGE ON FUTURE LOTS 1, 2, AND 3 IN ORDER TO COMPLY WITH RESIDENTIAL-4 (R-4) SETBACKS OF THE ZONE PRIOR TO FINAL PLAT APPROVAL. 2. THE APPLICANT SHALL INSTALL ONE NEW STREET IN THE ROW ADJACENT TO PROPOSED LOT 1. THE TREE SPECIES SHALL BE SELECTED FROM THE CITY OF RENTON'S APPROVED STREET TREE LIST AND BE APPROVED BY THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF CIVIL CONSTRUCTION PERMIT REVIEW. ALTERNATIVELY, THE APPLICANT MAY RETAIN THE EXISTING STREET TREE LOCATED IN FRONT OF PROPOSED LOT 1. 3. THE APPLICANT SHALL INSTALL REPLACEMENT TREES WITHIN THE TRACT IF FEASIBLE, AND SHALL PLANT SHRUBS AND OTHER GROUND COVER AROUND THE PERIMETER OF THE TRACT WHERE FEASIBLE. AN UPDATED LANDSCAPE PLAN INCORPORATING THE ADDITIONAL VEGETATION SHALL BE SUBMITTED WITH THE CIVIL CONSTRUCTION PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE CURRENT PROJECT MANAGER 4. THE APPLICANT SHALL SUBMIT AN UPDATED TREE RETENTION PLAN, ARBORIST REPORT, AND TREE RETENTION WORKSHEET THAT CORRECTLY IDENTIFY THE NUMBER OF EXISTING TREES ON SITE AND DEMONSTRATE COMPLIANCE WITH THE TREE RETENTION AND LAND CLEARING REGULATIONS IN RMC 4-4-130. THE APPLICANT SHALL UTILIZE THE TREE PRESERVATION PRIORITY TIERS OUTLINED IN RMC 4-4-130.H.2.o TO IDENTIFY THE SPECIFIC TREES TO BE RETAINED. THE APPLICANT SHALL SUBMIT A NARRATIVE DESCRIBING HOW ALL REASONABLE EFFORTS HAVE BEEN TAKEN TO PRESERVE TREES UTILIZING THE HIGHEST PRIORITY TIER POSSIBLE. THE UPDATED DOCUMENTS AND NARRATIVE SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 5. THE APPLICANT SHALL SUBMIT AN UPDATED TREE RETENTION PLAN, ARBORIST REPORT, AND TREE RETENTION WORKSHEET THAT CLEARLY IDENTIFIES THE TREES PROPOSED FOR RETENTION AND DEMONSTRATES COMPLIANCE WITH THE MINIMUM TREE DENSITY REQUIREMENT FOR RESIDENTIALLY ZONED LOTS. THE UPDATED DOCUMENTS SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 6. THE APPLICANT SHALL UTILIZE THE EXISTING CURB CUT OFF OF NILE AVE NE TO ACCESS THE SINGLE-FAMILY HOME ON PROPOSED LOT 3 r EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 - Phone: (509) 674-7433 DISCREPANCIES: IF THERE ARE ANY DISCREPANCIES BETWEEN DIMENSIONS IN DRAWINGS AND EXISTING CONDITIONS WHICH WILL AFFECT THE WORK, THE CONTRACTOR SHALL BRING SUCH DISCREPANCIES TO THE ATTENTION OF THE ENGINEER FOR ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF ALL WORK AND FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND PERSONS ENGAGED UPON THIS CONTRACT. CONTRACTOR RESPONSIBILITY. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. EXISTING UTILITY NOTE: ALL LOCATIONS OF EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. REVISION CJA 03108124 SURVEYED: DBM DESIGNED: SS DRAWN: PS CHECKED: CA BY DATE AP P R APPROVED: CA SCALE: IMPERVIOUS AREAS: ONSI TE LOT 1 MAX PER ZONING =4,607 SF LOT 2 MAX PER ZONING =5,083 SF LOT 3 MAX PER ZONING =5,153 SF TRACT A -GRAVEL DRIVEWAY=710 SF TOTAL ONSITE IMPERVIOUS =15,553 SF OFFSITE DRIVEWAY =551 SF TOTAL IMPERVIOUS=16,104 SF 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M 0 5 10 20 SCALE 1 " = 20' PROJECT TEAM: DEVELOPER: DAN FINKBEINER SIERRA HOMES PO BOX 3069 ISSAQUAH, WA 98027 (425) 471-3472 OWNER: AWESOME YAH CHURCH 702 NILE AVE RENTON, WA 98059 ENGINEER/SURVEYOR: CHAD ALLEN, PE/DAVID B. MATTHEWS, PLS ENCOMPASS ENGINEERING & SURVEYING 165 N.E. JUNIPER STREET, SUITE 201 ISSAQUAH, WA 98027 (425) 392-0250 GE07ECHNICAL ENGINEER: PHILLIP HABERMAN COBALT GEOSCIENCES, LLC PO BOX 82243 KENMORE, WA 98028 (206) 331-1097 ECOLOGIST. • JOHN ALTMANN ALTMANN OLIVER ASSOCIATES, LLC PO BOX 578 CARNATION, WA 98014 (425) 333- 4535 ARBORIST. ROBERT LAYTON LAYTON TREE CONSULTING, LLC PO BOX 572 SNOHOMISH, WA 98291 (425) 220-5711 BSBL DISTANCES: QFRONT YARD: 30' QREAR YARD: 25' QS SIDE YARD: 20' COMBINED (7.5' MIN) QSTREET.• 30' SHEET INDEX NO. TITLE 1 COVER SHEET 2 TOPOGRAPHIC SURVEY 3 TESC DEMOLITION AND TREE PROTECTION PLAN 4 TESC DETAILS 5 UTILITYAND GRADING PLAN 6 INFILTRATION TRENCH DETAILS 7 CONSTRUCTION DETAILS I 8 CONSTRUCTION DETAILS II 9 CONSTRUCTION DETAILS III 10 CONSTRUCTION DETAILS IV Know what's beIow. Call before you dig. • CITY OF PRI RENTON Planning/Building/Public Works Dept. VICINTY MAP NTS ni-rr V%n -rn. SITE ADDRESS. 702 NILE AVE NE RENTON, WA 98059 SITE AREA: 31,998 SF (0.73 ACRES) TOTAL PROPOSED LOTS: 3 TAX PARCEL: 112305-9002 ZONING. R-4 MIN LOT SIZE. 9,000 SF MIN LOT WIDTH: 70 FEET MIN LOT WIDTH (CORNER): 80 FEET MIN LOT DEPTH: 100 FEET MAX BUILDING COVERAGE. 357. MAX IMPERVIOUS COVERAGE: 50% DENSI TY 4 DU/ACRE UTILITY INFORMATION: SEWER: WATER: ELECTRIC/GAS: FIRE. TAX PARCEL: CITY OF RENTON KING COUNTY WATER DISTRICT 90 PSE RENTON REGIONAL FIRE AUTHORITY 112305-9002 HORIZONTAL DATUM: NAD 83189 BASIS OF BEARINGS: N87'27'22"W BETWEEN FOUND MONUMENTS ON NE 7TH PLACE VERTICAL DATUM: NA VD 88 BENCHMARK. CITY OF RENTON CONTROL POINT 1854. 3" BRASS DISK AT THE INTERSECTION OF NE 4TH STREET (SE 128TH STREET) AND 148TH AVENUE SE. ELEVATION = 454.77' INSTRUMENTATION: INSTRUMENT USED: 5 SECOND TOTAL STATION. FIELD SURVEY WAS BY CLOSED TRAVERSE LOOPS, MINIMUM CLOSURE OF LOOPS WAS 1:22,000, IN ACCORDANCE WITH WAC 332-130-090. LEGAL DESCRIPTION: LOT 1, WESTON HEIGHTS NORTH SHORT PLAT, CITY OF RENTON SHORT PLAT NO. LUA 16-000140 LND 20-0630, RECORDED UNDER RECORDING NUMBER 20171026900003, IN KING COUNTY, WASHINGTON. M Wrl'11 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EHHuynh ENT ENGINEERING:0 ESURFACE WATER UTILITY 09/27/2024 arah 09/27/2024 SIERRA HOMES SHORT PLAT L LI A 22-000315 COVER SHEET DATE: 06/19/202 FIELDBOOK: PAGE: 21706 SHEET: 1 OF:1 0 NN L.L N CN L0 O N A, LJ H H N Q J J CD C� LIJ 2E CD L.LJ C,� J O cry LIJ O LIJ C� 10 11 NE 8 TH S TREE T I TAX PARCEL 112305-9087 736 NILE AVE NE a 0 WHITE LANE STRIPE FOUND MONUMENT 0 SIERRA HOMES TOPOGRAPHIC SURVEY A PORTION OF THE NW 114 OF THE SW 114 OF SEC. 11, TWP. 23 N., RING. 5 E., W.M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON i SDMH RIM=518.51 TAX PARCEL 638930-0120 IE 12" ADS (N)=510.71 TRACT A IE 12" ADS (1E)=510.61 IE 15" ADS (W)=510.51 IE 6" PVC (S)=505.61 _ SSMH IN CASE I SDMH RIM=518.17 o RIM=519.67 FOUND IE 8" PVC (E)=512.77 IE 15" ADS (E)=510.17 MONUMENT IE 8" PVC (W)=512.67 3 IE 15" ADS (S)=509.97 SSMH IN CASE SSMH a RIM=518.79 RIM=519.75 IE 8" PVC (E)=512.44 SDCB IE 8" PVC (E)=511.65 N w W W IE 8" PVC (W)=512.34 RIM=518.37 IE 8" PVC (S)=511.75 _ W w w W w ww IE 12" DI (N)=515.37 IE 8" PVC (N)=511.85 - 0 95.23' � (P) 95.30' (M) ` W _ N87'2722"W 8 76 8 J W _SI FOUND MONUM sS. SASIS OF BEARINGS) SS SS . . . . N7 �5�v WIN CASE ~ . 0 SD �- SD SD SD. . SD SD . .SD SD 7.745"w 4^ _ W N W SD I' 19f� Q ADA SS `. . ��. aRAMP. SS TAX PARCEL 638930-0110 5718 NE 7TH PL LOT 11 OLYVPUS VILLA VOL. 260, PG. 26 SDCB RIM=517.87 ENT IE 12" DI (N)=515.62 �n IE 12" DI (E)=515.62 N w W w w w W W w w W W W 7 22"W 542.95� . T sco 3 ° TOP a SS cv ss - A a° . 1 BACK OF ss Ss -NE- T . . . . . CURB. . . . . . . . . . . . . . . . . . . . . . ss sS _ P ° P P P �a S° 1. . S D .SD S SD SD .SD . 1 N N87*27'22"W 222.80' P ° R TE ;SIDEWALK 3 W P 1: CI R=15.00' L=24.15' x 0 W W FOUND . . LLI REBAR &CAP LS #32441 3 Q 0.2' E. OF LINE LLJ a 3 .__j 2 Z.Q 0 II. N �c c c 3 � G G G G G G G G G G -G G G G- 36 5>I 3 TAX PARCEL GRAVEL DRIVE 112305-9002 (LOT 1) o POWER POLE 6' WF WITH LIGHT, 3 P OHP oHP GATE CONIC. TRANSFORMER 0 a °HP OHP OHP x P oHP OHP STEPS & 2 PWR DROPS I (0) a � P OHP oHP OH OHP W W W 14 OHP OHP �. sa'`. ROOF N w 44 S a PEAK FFE=519.11 CONC.=537.40 JDRIVE BARN N C*4 in N 0 Q - e Z FLOW ~. aLd LINE a 12" APL YARD DRAIN RIM=517.06 G G CONC. G STEPS I L_ -EAVE- I - -- - s ROOF I PEAK =535.47 FFE=521.13 ° 702 NILE AVE NE °- - - 3 ° 013" APL 0 23" APL a 0 1 v SSMH ��NW d s 6' WF RIM=516.85 � 0.6' N. IE 8" PVC (S)=507.85 0 s. 15" APL 9 APL W WF OF LINE 6 WF 1`4872722 W 184.74'026" APL p� 0.2' S. 0 22" APL OF LINE TAX PARCEL 112305-9135 �8 P TRACT A FOUND o REBAR & CAP T 6' WF CORNER 3 T . T LS #32441 0.2' E. & 0.1' S. ON LINE OF CORNER 0 N . WHITE LANE 30 0Q FOUND REBAR & CAP STRIPE LS #32441 a x 0 SDCB RIM=515.48 IE 12" DI (E)=513.08 a I z 0 SDCB RIAA ri1d QPOWER POLE =5 CITY OF RENTON CONTROL POINT #1852 3" BRASS DISC ON STREET BENCHMARKFACE NE 4TH STREET 10 11 ELEVATION=454.77 N88'21'22"W 2622.55' 15 14 - - - Z MA OF WASkI� EncomDass ENGINEERING & SURVEYING `� b �O Western Washington Division 36804 w w 165 NE Juniper Street, Suite 201 " Issaquah, WA 98027 " Phone: (425) 392-0250 �SSlO�GISTSg��4� Eastern Washington Division NALLAN0 w 407 Swiftwater Blvd. • Cle Elum, WA 98922 " Phone: (509) 674-7433 08/2024 NO. REVISION U- 010" DEC 77, WESTON HEIGHTS NORTH SHORT PLAT VOL. 373, PG. 69 0 A=67'36'35" R=75.00' L=88.50' SDCB RIM=519.48 IE 12" DI (E)=516.68 wIE-12' wD - X=v51L-4-8W IE 6" PVC (S)=516.68 z m<7 P ..p P 6' WF CORNER 0.2' E. OF LINE TAX PARCEL 112305-9130 5717 NE 7TH PL LOT 2 6' WF CORNER 0. 5' W. & 0.1' S. OF P CORNER OHP TAX PARCEL 112305-9136 6" DEC TRACT B 6' WF CORNER 0.2' E. & 0. 8' N. OF CORNER - CITY OF RENTON CONTROL POINT #2103 FOUND DAMAGED - - - n - MONUMENT T -w SD 4.1 (M) (P) N /01 In 0 Ossco El h ❑T E- 0 -P P - OHP OHP -T T -w W SD SD c c G LEGEND FOUND MONUMENTIN CASE FOUND REBAR & CAP MEASURED PLAT WATER VALVE FIRE HYDRANT WATER METER IRRIGATION CONTROL VALVE SEWER MANHOLE SEWER CLEANOUT STORM MANHOLE CATCH BASIN YARD DRAIN JUNCTION BOX LIGHT POLE LIGHT POST TELEPHONE RISER POWER POLE GUIDE WIRE GAS METER UNDERGROUND POWER LINE OVERHEAD POWER LINE UNDERGROUND COMMUNICATION LINE WATER LINE STORM LINE SEWER LINE GAS LINE WOOD FENCE (WF) DECIDUOUS TREE CONCRETE ASPHALT GRAVEL Know what's beIow. Call before you dig. 0 5 10 20 SCALE 1 " = 20' TAX PARCEL 112305-9002 VERTICAL DATUM NAVD 88 BENCHMARK CITY OF RENTON CONTROL POINT 1854. 3" BRASS DISK AT THE INTERSECTION OF NE 4TH STREET (SE 128TH STREET) AND 148TH AVENUE SE. ELEVATION = 454.77' HORIZONTAL DATUM NAD 83/91 PER CITY OF RENTON SURVEY CONTROL BASIS OF BEARINGS N87'27'22"W BETWEEN FOUND MONUMENTS ON NE 7TH PLACE INSTRUMENTATION INSTRUMENT USED: 5 SECOND TOTAL STATION. FIELD SURVEY WAS BY CLOSED TRAVERSE LOOPS, MINIMUM CLOSURE OF LOOPS WAS 1:22,000, IN ACCORDANCE WITH WAC 332-130-090. LEGAL DESCRIPTION LOT 1, WESTON HEIGHTS NORTH SHORT PLAT, CITY OF RENTON SHORT PLAT NO. LUA 16-000140 LND 20-0630, RECORDED UNDER RECORDING NUMBER 20171026900003,IN KING COUNTY, WASHINGTON. R-428302 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING H' HHuynh 09/27/2024 SURVEYED: DBM SCALE: „, 1 =20 HORZONNTAL: N D 11983/1991 DATU M ' C TY OF VRPS RENTON NOXIV Planning/Building/Public Works Dept. SIERRA HOMES SHORT PLAT LUA 2 2- 0 0 0 31 5 TOPOGRAPHIC SURVEY DATE: 06/19/202 DESIGNED: SS FIELDBOOK: PAGE: DRAWN: ONE INCH DRAWING NO: 21706 CHECKED: CA AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE AP P R APPROVED: SHEET: 2 OF:CA 1 O L.L co N L J O co A, LJ H H N N Q J CY) C0 N I C:) I LU TAX PARCEL 112305-9087 736 NILE AVE NE a 0 WLE LANE STRIPE 3 C ' 3 SDMH o RIM =519.67 IE 15" ADS (E)=510.17 3 IE 15" ADS (S)=509.97 SSMH SSMH RIM=518.79 RIM=519.75 ~ 0 ~ IE 8" PVC (E)=512.44 IE 8" PVC (E)=511.65 w W IE 8" PVC (W)=512.34 IE 8" PVC (S)=511.75 _ w w w w w w w W IE 8" PVC (N)=511.85 0 95.23' (P) 95.30' (M) N8T2T22"W 86.78' ss. 3 . s I. (�3ASIS OF BEARINGS) �' SS SS ro SD SD SD .SD. SD SD .SD SD. o . N ADA 0 sco I^ 3 o AMP n c3 III` P p _ e P N. 4 a=9215'03" R=15.00--s - ------ =24.15' 0 EX. GAS LINE TO BE w w ti _ TREE CUT AND CAPPED UN711 0LLJ PR07ECTIOAI THE S17E IS DEVELOPED Z a , �� TO BE COORDINATED 3 NTH PSE) LEI G c c c c 01 77 I 0 POWER POLE WITH LIGHT, 3 TRANSFORMER 0 & 2 PWR DROPS W w w c� 3 N w � ^ 3 T O Z ' FLOW a LINE � 3 I SSMH 0 RIM=516.85 IE 8" PVC (S)=507.85 0 3 3. WHITE LANE STRIPE SDCB RIM=515.48 IE 12" DI (E)=513.08 z 0 SDCB POWER POLE RIM=514.95 IF 1..5" AnS (NI=.SnR l.5 0 WITH LIGHT, r EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 " Issaquah, WA 98027 " Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 - Phone: (509) 674-7433 SDMH RIM=518.51 IE 12" ADS (N)=510.71 IE 12" ADS (NE)=510.61 IE 15" ADS (W)=510.51 IE 6" PVC (S)=505.61 TAX PARCEL 638930-0120 TRACT A SSMH RIM=518.17 IE 8" PVC (E)=512.77 IE 8" PVC (W)=512.67 OLYMPUS VILLA I VOL. 260, PG. 26 SDCB RIM=517.87 IE 12" DI (N)=515.62 TAX PARCEL 112305-9135 TRACT A TREE PROTECTON FENCE 6' FROM PROPERTY LINE PER ARBORIST MEMO. SEE TREE PROTECTION NOTE 1 1 PER CITY COMMENTS REVISION TAX PARCEL 638930-0110 5718 NE 7TH PL LOT 11 EX. SIDE SEWER TO BE CUT AND CAPPED UN71L THE SITE IS DEVELOPED 0 5 10 20 SCALE 1 " = 20' A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES OR COMPACT THE EARTH IN ANY I WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED. B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING _ THE TREE EQUAL TO ONE AND ONE QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1) OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50') INDICATING THE WORDS 'NO TRESPASSING -PROTECTED TREES, OR ON EACH SIDE OF THE FENCING IF LESS SDCB RIM=519.48 THAN FIFTY FEET (50). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF 11 12" DI (E) = 516.E 8 TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) wIC �2 L4 � SIDES. IN ADDITION THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR W - IE 6" PVC (S)=516.68 TRUCKS ARE MOVING NEAR TREES. C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE - - RETAINED IS TO BE RAISED, THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE TREE'S DRIP LINE. D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE THE APPLICANT MAY NOT INSTALL IMPERVIOUS SURFACE MATERIAL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY. E. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL AROUND ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF THE 7 FOLLOWING AREAS. 1) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR 2) AN AREA �� AROUND THE TREE EQUAL TO ONE AND ONE HALF FEET (1-1/2) IN DIAMETER FOR EACH _ _= ONE INCH (1) OF TREE CALIPER. A LARGER TREE PROTECTION ZONE BASED ON TREE SIZE, SPECIES, SOIL OR OTHER CONDITIONS MAY BE REQUIRED. CATCH BASIN INSERT F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED PR07EC71ON PER COR COMPLETELY AND EVENLY WITHIN A MINIMUM OF THREE INCHES (3") OF BARK MULCH PRIOR S1D PLAN 216.30 (TYP) TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BE APPROVED IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST OR LICENSED LANDSCAPE ARCHITECT TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES OR ROOTS, FERTILIZE AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED. H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFEGUARDS MAY BE USED IF DETERMINED TO PROVIDE EQUAL OR GREATER TREE PROTECTION WITH APPROVAL FROM THE CURRENT PLANNING PROJECT MANAGER. TAX PARCEL 112305-9130 5717 NE 7TH PL LOT 2 0=67'36'35" R=75.00' L=88.50' TAX PARCEL 112305-9136 TRACT B CLEARING AND GRADING LIMITS (TYP) TREE TO BE REMOVED (TYP.) SEE ARBORIST REPORT & LANDSCAPE PLAN FOR ADD17IONAL DETAILS ON TREE REMOVAL & REPLACEMENT CJA 03108124 SURVEYED: DBM DESIGNED: Ss DRAWN: PS CHECKED: CA BY DATE AP P R APPROVED: CP SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Dripline r I I y I i � I I t� I � I I � 6 FLTemporary I Chaln Link Fence coucal -- r -Root Zone _ F!nun ti - . - `, v ROOTS NOb J : One sign per 50 feet n 1' TRESPASSING (misigns) PROTECTED nimum of 2 si ns 1O Ft. TREES Figure 1. TREE PROTECTION FENCE DETAIL. DRIPLINE METHOD VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Know what's beIow. Call before you dig. • CITY OF PRI RENTON • Planning/Building/Public Works Dept. N TESC LEGEND: Ln co X X SILT FENCE O CLEARING LIMITS O o 0 CONSTRUCTION ENTRANCE CNV ® INLET PROTECTION r@1 EROSION PROTECTION NOTE: ALL EXPOSED SOIL AND/OR DISTURBED SURFACES TO BE COVERED WITH MULCH, STRAW, AND/OR PLASTIC SHEETING PER FIG. C.3.4.A AND/OR TABLE C.3.2.A CORSWDM. UNDER NO CIRCUMSTANCES SHALL SOIL STOCKPILES BE LEFT UNCOVERED. CONSTRUCTION SEQUENCE: 1. PRE -CONSTRUCTION MEETING. M 2. POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER N OF ESC SUPERVISOR. N LO J. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. (Z) 5. GRADE AND INSTALL CONSIRUCITON ENTRANCE(S). N 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS. 8. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS. 9. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS (V DURING THE DRY SEASON OR TWO DAY DURING WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT. C) 10. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. C) C) 11. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. N UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE. N 12. UPON COMPLETION OF THE PROJECT. ALL DISTURBED AREAS MUST BE STABILIZED AND BMP'S REMOVED, IF APPROPRIATE. J APPROXIMATE CUT/FILL VOLUMES CUT.• = 550 CY FILL: = 50 CY (CONTRACTOR TO CONFIRM) DISTURBANCE AREA 30,367 SF DEMOLITION NOTE: ALL EXISTING IMPERVIOUS SURFACES AND STRUCTURES TO BE REMOVED PRIOR TO START OF CONSTRUCTION TREE PROTECTION NOTE: TREE PROTECTION FENCING SHALL BE POSITIONED AROUND PROTECTED TREES PRIOR TO SITE DEMOLITION OR BRINGING ANY HEAVY EQUIPMENT ONTO THE SITE. THIS WILL HELP TO DEFINE CLEARING LIMITS AND PROTECT SOILS AND SURFACE ROOTS. SOILS SHALL BE CUT AND PULLED BACK AWAY FROM THE TREES TO AVOID TEARING AND SHREDDING ROOTS INSIDE THE PROTECTION AREA. ANY ROOTS FROM PROTECTED TREES DAMAGED DURING SITE WORK OUTSIDE OF THE TREE PROTECTION AREAS SHALL BE PRUNED CLEAN AT SOUND TISSUE PRIOR TO BACKFILLING OR FINISHING AREAS. SOUND TISSUE IS WHERE THE ROOT IS UNDAMAGED AND THE BARK IS COMPLETELY INTACT WITH THE ROOT. THIS WILL HELP ROOTS TO SEAL OFF POTENTIAL DECAY AND ALLOW THEM TO SPROUT NEW GROWTH. ANY DISTURBED AREAS NEAR PROTECTED TREES SHALL BE WATERED WEEKLY DURING THE DRY SEASON OF MID -MAY THROUGH MID-OCTOBER. THOROUGHLY WATER THE OUTER DRIPLINE AREAS EVERY 7 TO 10 DAYS TO MAINTAIN A FAVORABLE ENVIRONMENT FOR NEW ROOT GROWTH AND TO REDUCE THE DEGREE OF STRESS ASSOCIATED WITH THE SITE CHANGES. EQUIPMENT SHALL BE KEPT OUTSIDE OF TREE PROTECTION AREAS AT ALL TIMES. ANY BRANCHES THAT ARE DAMAGED DURING SITE WORK SHALL BE PROPERLY PRUNED. MAINTAIN THE EXISTING GRADES WITH THE PROTECTION AREAS. FINISH THE LANDSCAPE WITHIN THE DRIPLINES OF PROTECTED TREES BY SIMPLY MAINTAINING THE EXISTING LAWN OR COVERING THE AREA WITHIN THE DRIPLINE WITH A +/- 4-INCH LAYER OF ORGANIC MULCH. KEEP IRRIGATION TRENCHES, LARGE PLANTINGS OR OTHER IMPROVEMENTS OUTSIDE OF THE TREE PROTECTION AREAS. R-428303 J IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERINGCD HHuynh 09/27/2024 = cry Cn w 2E DATE: CD SIERRA HOMES SHORT PLAT 06/19/2024 = L LI A 2 2- 0 0 0 315 FIELDBOOK: PAGE: DRAWING NO: TESC DEMOLITION AND TREE PROTECTION PLAN 21706 SHEET: Z OF:1 O M 00 N I O IT 1 r) W I- LJ Z J Li DocuSign Envelope ID: 6EECF5B6-602A4E4A-6436-A317AA638878 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS USE STAPLES, WIRE RINLIS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2-x2" 14 GAUGE WIRE; OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRK: I --I�------------I�-- I I 6 MAX I I 12, MIN POST SPACING 11,111841 SLED 4•x4' MIN. TRENCH I I I IL�JI TD 8' IF WIRE BACKING 15 48 USED BACKFILLTRENOH WITH NATIVE SOIL L 1 OR "r14" TO 1-112" WASHED GRAVEL 2'k4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP-) NOTES: I CONDITIONS OF USE 1.1. SILT FENCE MAY HE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1-2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 11 THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURERS FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE ADS (ASTM D4751I 30-t00 91EVE SIZE (E3.80-p. &w I FOR SILT FILM 50•tOO SIEVE SIZE (0 304�.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM P8491) O.D2 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM 134532) 1BULBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAS TENSILE ELONGATION (ASTM 64632) 309E MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM 04355) 70%MIN 2.2 STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTIi OF THE FENCE WIRE BACKING OR CLOSER POST SPACING MAYBE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE, 2,3- WHERE THE FENCE IS EN5TALLE3, THE SLOPE SHALL NOT BE STEEPER THAN 2H_1V 2.4- IF ATYPICAL SILT FENCE IS USED. THE STANDARD 4'X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 81NCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE- 2.5, FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE, 3- MAINTENANCE STANDARDS 3.1- ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 8.2, IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. S.3, IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A HARRIER TO FLOW AND THEN CAUSING CHANNELLZATEON OF FLOWS PARALUEL TO THE FENCE- IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED? SEDIMENT. 3-4- SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS S INCHES HIC4 I. 3.5. IF THE FILTER FABRIC (GECTEXTILEy HAS DETERIORATET7 DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHE; F W 15E NOAA. pIw W ING IS hOf tO SCALE LFTTSI STD. PLAN - 214.00 a PUBLIC WORKS SILT FENCE FGAZ R 9/29/2019 1 DEPARTMENT PWeh Wool P,ImN.vuiu DATE EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Hum, WA 98922 • Phone: (509) 674-7433 :45 AP OccuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 S'MAX DRAINAGE GRATE TRIM GRATE FRAME _ OVERFLOW BYPASS Y BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN} RETRIEVAL SYSTEM (TYP.y OVERFLOW BYPASS (TYP 1 9ELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: 1. PROTEC;TION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 5011 FE-ET OF A DISTURBED OR CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OF TRY,F 2, INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3, THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE IBIGM FOR THE STORMWATER STRUCTURE IT WILL SERVICE- S. THE MOD SHALL HAVEA BUILY-IN HIGH-FLDW RELIEF SYSTEM (OVERFLOW BYPASS). S. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION "I.3(15), 8. ANY SEDIMENT IN THE CATCH BASIN INSERT $HALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS 01HERWI5E ra"O, PI AWING IS NOT TO SCALE IkT51 STD. PLAN - 216.30 �a PUBLIC WORKS APP rD- 1` DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 P„inPATE 1 1 PER CITY COMMENTS 11[0i IG42011 ` 10101 CJA :4S All DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA538878 �KISAI�O¢O� R • 25' MKJ. �0 INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS 4%6" QUARRY SPALLS GEOTEXTIL E 12' MIN. THICKNESS 1q0' MIN CONSTRUCTION ENTRANCE NOTES: 1 DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TD AVOID DAMAGING OF THE ROADWAY. 2. IT M RECOMMENDED THAT THE ENTRANCE HE CROWNED SO THAT fiUNOFF DRAINS OFF THE PAD 15' MIN. PROVIDE FULL WIDTH OF INGRESEPEGRESS AREA NOTES: t- caNDTTH}N OE Us1E 1-1, CONSTRUCTION ENTRANCE SHALL BE STABILZEV WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE BITE 1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MA114 SUBDIVISION ENTRANCE STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTWWIDTIi 74 PROVIDE VEHICLE ACCESS4PARKING, BASED ON LOT SIZEICONFIGURATION, 2, D€SIGN AND INSTALLATION SPECIFICATION6 2.1. A SEPARATION GEOTE:CTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROC1C PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM 04632) 200 LBS. MIN GRAB TENSILE ELONGATION (ASTM 04632) SO% MAX. (WOVEN) CBRPUNCTURE STRENGTH (ASTM D6241) 4M LBS. MIN AM (ASTM 04T5T) 2M5 (U.S-STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE W LEVELS IN STORMWATER AND CONCRETE DISCHARGE 70 SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3- HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL LS REINS CARRIEO OWTD PAVEMENT- 2.4- FENCING 58ALL BE INSTALLED AS NECESSARY TD RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE 2.6. WHENEVER POS91BLE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM- COMPACTED SUBGRADE THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. E MAINTENANCE STANDARDS 3.1- OUARRV SPALLS SHALL BE ADDED IF THE PAD 15 NO LONGER IN ACCORDANCE WITH THE SPECIPECATLONS. 3.2- IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES 70 KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE; STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WMA CRUSHED ROCK. AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET- EXCEPT VMEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTIF0. THE SEDIMENT WOULD THEN BE WASHED 1NTG THE SUMP WHERE It CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST AF PUMPM HACK ONTO THE SITEA NO CANNOT DISCHARGE TO SYSTEMS TRIBUTARY to SURFACE WATERS. 3.4. ANY QUARRY SPALLS THATARF LOOSEN€P FROM THE PAP AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDJATEI_Y. 3.5 IF VEHICLES ARE ENTERING ON EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUGTIO14 ENTRANCE(S}, FENCING SHALL BE INSTALLED TG CONTROL TRAFFIC. rJNLfSS CINERwISI NOTED, DRAWING 15 NOt tO StALi (NT'! STD. PLAN - 215.10 PUBLIC WORKS aP 50vEP' DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 I - n:wwwnninn DATE i �� 0 1ja- SURVEYED: DBM VERTICAL: NAVD 1988 DESIGNED: HOHORIZONTALNAD 1983/1991 SS DRAWN: PS DATU M CHECKED: APPROVED: SCALE CA SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY :45 Al DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1 ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1 ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 PRIft PUBLIC WORKS EROSION AND SEDIMENT CONTROL PPR D: DEPARTMENT GAZ 9/28/2018 1 STANDARD PLAN NOTES P ft Works AEminisVabr DATE Know what's below. Call before you dig. 0�� CITY OF RENTON e Planning/Building/Public Works Dept. :45 AN R-428304 I-6 A I, , �J im, N N Q J IN COMPLIANCE WITH CITY OF RENTON STANDARDS � DEVELOPMENT ENGINEERING O HHuynh 09/27/2024 = cn cry w DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = L U A 2 2- 0 0 0 31 5 FIELDBOOK: PAGE: DRAWING N0: TESC DETAILS 2170E SHEET: OF: 4 10 SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY :45 Al DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1 ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1 ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 PRIft PUBLIC WORKS EROSION AND SEDIMENT CONTROL PPR D: DEPARTMENT GAZ 9/28/2018 1 STANDARD PLAN NOTES P ft Works AEminisVabr DATE Know what's below. Call before you dig. 0�� CITY OF RENTON e Planning/Building/Public Works Dept. :45 AN R-428304 I-6 A I, , �J im, N N Q J IN COMPLIANCE WITH CITY OF RENTON STANDARDS � DEVELOPMENT ENGINEERING O HHuynh 09/27/2024 = cn cry w DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = L U A 2 2- 0 0 0 31 5 FIELDBOOK: PAGE: DRAWING N0: TESC DETAILS 2170E SHEET: OF: 4 10 Co M 0 N 00 N 'zt LU i.i Z J U_ I I W ITE LANE 0 STRIPE 3 � REPAIR\REPLACE CONCRETE SIDEWALK PER COR STD PLAN 102 (TYP) SSMH RIM=519.75 IE 8" PVC (E)=511.65 IE 8" PVC (S)=511.75 IE 8" PVC (N)=511.85 . . . ss. s N SANITARY SEWER STUB W/ I 3 N SSCO PER COR STD PLAN 406.1 (TYP) TYPE 1 CB W/SOLID LOCKING LID RIM=51 &80f IE=514.20 (SE) 6" . W z3 W � W N Q . . .LU N RE -USE EXISTING WATER METER AND SERVICE FOR LOT 3 (SEE WATER NOTE) POWER POLE WITH LIGHT, TRANSFORMER & 2 PWR DROPS w w USE EXISTING DRIVEWAY ENTRANCE ON NILE AVE. FOR LOT 3 22 LF 12" I . . .I PVC ® 3 0.59 PUBLIC TYPE 2 CB FL RIM=517.14t I LINE IE=509.62, (E) 12" IE=509.37, (N,S) 15" 3 15' RESIDENTIAL 3 DRIVEWAY PER COR STD PLAN 104.3 SSMH / RIM=516.85 IE 8" PVC (S)=507.85 � 3 WHITE LANE STRIPE I SDCB RIM=514.95 IF 1.5" Arlo (N)=.5nR q.5 TAX PARCEL 112305-9087 736 NILE AVE NE CONNECT TO EXISTING 'EWER MAIN PER COR STD SDCB RIM=515.48 IE 12" DI (E)=513.08 M POWER POLE WITH LIGHT, 0 DRIVEWAY AS NEEDED FOR ACCESS TO NEW ACCESS RISERS. SDMH RIM=518.51 IE 12" ADS (N)=510.71 IE 12" ADS (NE)=510.61 IE 15" ADS (W)=510.51 IE 6" PVC (S)=505.61 TAX PARCEL 638930-0120 TRACT A SSMH RIM=518.17 IE 8" PVC (E)=512.77 IE 8" PVC (W)=512.67 I I OLYMPUS VILLA VOL. 260, PG. 26 I SDCB RIM=517.87 IF 1?" nI (0=51.5 6? LOT 9.�14 SF TAX PARCEL 638930-0110 5718 NE 7TH PL LOT 11 I I -PAVEMENT RESTORATION PER COR STD PLAN 110, 110.1, 110.2 (TYP) I- WATER METER SERVICE (TYP) (SEE WATER NOTE) SDCB RIM=519.4 IE 12" DI " W w I E 12' '' wDa- IE RETAIN EX / 6" PVC 5' SIDEWALK =515.00,V 6" (SW) STONy1EIGHTS NORTH SHOK PLAT VOL. 373\ PG. 69 3 z \ I EA 1 NA B ch \ cr 88.50' 75.00' R LIMITED INFILTRATION PER DETAIL SHEET 5 (TYP.) OCA71ON TO BE M&WtHISINGLE FAMILY PERMIT TAX PARCEL 112305-9130 5717 NE 7TH PL LOT 2 I _ TAX PARCEL 112305-9136 TRACT B 5.� APPROXIMATELY 2,800 SF OF LAWN AREA IN THE SOUTHEAST PORTION OF THE SITE TO BE GRADED TOWARDS OFF -SITE 7' S19 / WETLAND TO THE SOUTHEAST. NO A - - 70.26' _ PORTION OF ANY BUILDING CAN BE 22" APL WITHIN THE HATCHED AREA. 26" APL-- TAX PARCEL 112305-9135 �b _ TRACT A _518 L 2' COVER MIN OVER 54'x15'x84"0 CONTECH CMP S TER DETENTION TANK PER FACCILITYILITY DETAIL SHEET 5 IE=509.73 BOTTOM=509.23 MAX WATER EL=516.23 TOTAL STORAGE=4,168 CF STORM NOTE: ALL STORM FEATURES ARE PRIVATE IF NOT SPECIFIED. FIRE SPRINKLER NOTE: FUTURE HOMES MUST BE EQUIPPED WITH DISTRICT APPROVED FIRE SPRINKLER SYSTEM. ACCESS OPENING NOTES: • ACCESS OPENINGS ARE REQUIRED WITHIN 50 FEET FROM ANY LOCATION IN THE FACILITY AND WITHIN 5 FEET OF EACH TERMINAL END. • ALL ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES PER SECTION 5.1.8 OF THE 2022 RSWDM. EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 0- M E S V WAS, 4 CROSSING KEYNOTES: TOSS=513.48 VERTICAL SEPARATION=3.61' O2 BOW=517.48 TOSS=513.82 VERTICAL SEPARATION=3.66' *PROVIDE ETHAFOAM FOR VERTICAL SEPARATIONS UNDER 1.5' 1 I PER CITY COMMENTS 2 SITE PLAN & DRAINAGE PER CITY COMMENTS I SO 201164to] II CJA 03108124 SURVEYED: DBM NEM 08/21/18 DESIGNED: SS DRAWN: PS CHECKED: CA BY DATE APPR APPROVED: CA 0 5 10 20 SCALE 1 " = 20' SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M ELEV=518.00 OVERFLOW RISER ELEV=516.73 0 23/32" DIA ORIFICE PIPE SUPPORT: 3"x.090 GAGE BOLTED OR INBEDDED 2" IN WALL AT MAX. 12" S.D. 3' SPACING. MIN OUTLET PIPE ONE SUPPORT. 1 INV=509.73 0 1' SECTION OF PIPE I ATTACHED BY GASKETED `V BAND TO ALLOW REMOVAL z_ RESTRICTOR PLATE L21/32"DIA ORIFICE N MAX. W.S. = 516.73 HANDHOLDS, STEPS OR LADDER CLEANOUT GATE � 12" S.D. INLET PIPE \INV=509.73 54" DIA CONTROL MANHOLE, TYPE 11, 54" N. T. S. Know what's belOW. Call before you dig. CITY OF • RENTON Planning/Building/Public Works Dept. N LO M0 I N A, LJ H H R-428305 S-428301 J IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPMENT ENGINEERING SURFACE WATER UTILITY CD HHuynh 09/27/2024 JFarah 09/27/2024 _ cn WASTEWATER UTILITY cn jstowell 09/27/2024W1 DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = L LI A 2 2- 0 0 0 31 5 FIELDBOOK: PAGE: DRAWING NO: UTILITY AND GRADING PLAN 21706 SHEET: OF: 5 10 V) CM 00 N ti N w z w J L� N N ry n CM N N LO C) C:) C'7 N A, u H H N N Q J ry- CD cry cn w 75 CD Q w ME co 00 N I O W 6i m Z Ld C RAISED EDGE DETAIL SIDEWALK LEVEL IR' iiTFJ.b S1tllWAUC 1RANSVEASE 1'-Ir i'•ff r(M PREMOLDED.VW7 F13LEJR trti - n1'1}rL JOWTS To INCLUDE R ISM E77GE rYPicAL 12•rN'rl++ lrml WHERE APPLICAllLE Raul ING zo'L i FOR CURB OITTAILS •. ��, : I-af SEE STC IR.w 16, rr t• tlNj R • ... kW. N r •� • N rTF-" 'irk' tiK9AfiVAY . �� Rfl 4Ck SEE FWSEA Ef7GE ,• • d' SIDiSgALK DETAIL - Tk n35HEET �TYpIOµ eNPF7Y » CRUSHED SURFACING TOP COURSE (CSTC} ALL CUT 9,i,iWAL1( i'At( ILL 951E LrppIF10 PROCTOR SLOPE 7AIN vwTHRAIseDEIIGE (UNLESS REQUIRETAENTWANED8Y ENGINEER]TYPr{.ALLWaTO UNDFA ) r? (rN1 R [TT'Pi G,Tt1'ER& E7DEWAxR [SIC DHDER FOR CURE DETAILS CURB a OUSTER TO BE ♦'THX>cr 33 OR SEE STO WEAN 10 I BATCH LrD.4T]NO ROADWAY CRUSHED ROCK vat r.-.T {tV/ BA9- WHICHEVER IS GREATER 9" FOR 6µ 5r ALL CURB &GUTTER) F _ `4 1 TOP O COINC ZIPE SURFACE rqp of W1rCRETE sURFAC11 2-P aJ EwuK ADJACENT TO CURB I. B, 1, ¢ FAIN IlrON)R . TTYP 1 RoiH PIA FOR CURD OEIAILS I �?.�-' } t.'+% SEE OTC PLAN 101 _ .__-. _ F BWOGE OR PEDFSTRVJR 5�''.ri . ADJACENT TO CURB RAWER -SCE S,nEWALK FOR cuae DETAILS SEF SrD PLAN lot (STEEP FILL S(GPESJ CO-YTRACT PLANS j•--W N.L CR BA WER PLUS" 1$'A - SIDE1Yr11Jt VERTICAL WALL- •ti-- V ;•j,:,,r _ SEE DETAIL 2W IIN]PREMRCEP -.- JOINT FILLER ADJACENT TO CUR(3 AND RAILING QR VVAI L 'er ELKS PFIE7JOLOED JOINT FriLER FOR SIDE SIDEWALK rM STRIP SI LMWALK ADJACENT TO WAIL DETAIL (511E ROTE 10) SIMWALK sIBEWALK 1)7(114R O'h' 1 FOR CURB DETAILS tEk '5X MW. SEE Sip PLAN 101 BRDaMEP FINISH OIR MATCH OC ITTIN12 5 s•rnDF-SMOOTH qc] L� TROWEL® PERMITTER FINISHpO GRADE 1' pRl BELCH' iOPl]F CONCRETE SURFACE FOR PL AtrTrNO-FLUSH IV PAVED f ADJACENT TO BUFFER STRIP jd Yj' ti .ti �, jCLJ ft T D GUT ETZ CURB (Luw1ANDDurrTRSHORNI FOR CURB DETAILS 5,Q zv SEE STO PLAN 1B1 ! 11W TO 1W NOTES 1. Four feet of the skit-plk width Shan minimum pedestrian COMPACTION JO 7 . • • •, E be the r P� t� IN SIDEWALK ONLY T erc@ea7hfe r6,e1@ ww Leo of YcrtlCel ,•R • Rto •� and horizontal Cowers. JUM L'on B. Gratlngs, Access zontal Iziru do BgGr FULL-0" 0WANSIOR JOINT IN BOTH • ' Cable Vault, Pull Boxes and other OVfI6 AND SIPETNJILI(6tL STe lkAB 7DL71 a, punoaanom wl:hln the Sldenralk 21W C CONTRACTION JOINT must be flush wldl Surface, and with g radio of the sidexrak. JOINT AND FINISH ` DETAJL 2. Monetithl r Cem"T Concrete Curls and f. • '•`'{:'. O': Sddewalk It not permlued In rlew For other referenced NOTES see 'E R censtructien. When replacamentwmk Da $TU PLAN 104 2 COM1CrEteCulWldperV5DDT PaEMCt-DE Staod■rd Prue F-30.I0-03. Paved Surfaces must Comply with JOINT FILLER E FULL DEPTH 3. Concrete tobe4,o00PSI, STD PLAN 102-1 as applicable. EXPANSION JOINT a PUBLIC WORKS CEMENT CONCRETE PLAN - 102 ''I' DEPARTMENT SIDEWALK � 1I(I?•??� r Mem IMLLL7 I. ANE 'I LANE 'f LANE : I I r i I r I I } I I. I I rr I ') INITIAL 2" DEEP SAWCUT OR GRIND., AND LIMIT OF FINAL OVERLAY. GRIND AND PAVE I FULL STREET WIDTH OVERLAY REOUIRED. I r ! I f J i t/.� �I m /r f ]{ 1 I I r it J f I, �. } I+ I rl I ' E I EDGE OF EXISNNG PAVEMENT Jrr J{ k EDGE OF TRAVELED LANE (EDGE STRIPE) f} ! re i .. .. 1: I J 7 L VARIES: 4.5' MIN (SEE STD PLAN 110.1) CENTER OF ANY MARKED LANE LINE, PROVIDE NEW CHA14NELIZATION I AFTER OVERLAY + I SECONOARY FULL DEPTH SAWCUT FOR d } PROPOSEIS TRENCH + i i INITIAL 2" DEEP SAWCUT QR GRIND, AND 1 i LIMIT OF FINAL OVERLAY. GRIND AND PAVE FULL STREET WIDTH OVERLAY REQUIRED O LANE LANE. LANE FOR TYPICAL SECTION AND NOTES SEE STANDARD PLAN 110.1 STD. PLAN - 110.2 PU13LIC WORKS REQUIRED SAWCUT, GRIND AND DEPARTMENT OVERLAY FOR LONGITUDINAL TREIIICHES r EncoMD,ass r GTE ENGINEERING SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 - Phone: (509) 674-7433 tIq ICY IT,RiWEa'Jp:LwiN RW�i E 11A Y/,T :1xi N61E r 4Fk . - - P1EclIOTE■ �- - tliTkNgTSH 'J tl aFP&YEa I r pwar.r+r redlDlrlN ar darMvoNJGr, [,4}� CVA♦ I1FE.,C Im G,fICICR6 7L1E1.A-ti 'g / # R C 1 j .FF krtir t L A s R oH.sfn aLerq,Ef .f CdkdRiF a.,•r,Kk.,M,Y � Nraorsrrl■ iL OFE1TL4, LEER NB,E] r.• Wr, I-, SM M 1AN M PLAN VIEW ] m C YaI 4'MI GENtA: UA�11E1i ii� 1�E�IF4■IOr brr Tr'rTl ISM tCJTrLA SOEWY.. E d1R RAN le]i SEL1l0++ LJf A 3 - 14 Am+: . r Imlw,u■raeT. . u,"EPEr�F ti5l�El IUA `` _ )� fRIKR1Lo p��R1�tCOPi iS[OR 1k1DNiTi7.LLV,[MSFBI `- f _ �1 FIT, a4AwaE r,rrl BILNLYIAE W pugX,VE 'rE4A,kYE BLDTF I>•�r'1. J/ 1 t4luriu'1 C6�r1E (E cure OUT37a Jul NOTE ]r TYPE R113 - ISOMETRIC VIEW (rZESIC)ENTIAG WITH BUFFER) For NOTES STD PLAN 104.2 . o STD. PLAIT - 104.3 PUBLIC WORKS CEMENT CDEI+ICRETE DRIVIEVIIAY Pr'Ft ED + L DEPARTMENT ENTRANCE - TYPE IR1fS f La.r.'ri1JMJIr�_ u�vll DDCuSign E.rivelope ID: 6EECF5B6.602A4E4A-B436-A317AA638878 FRAME AND VARIED GRATE •,6,1r,OR2a- ONE *3 BAR HOOP FOR or HEIGHT tNCRZMENT (SPACED EQNUALLYI, SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION N3 84R EACH CORNER x3 BAR EACH SIDE Y' 43 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP 4313AR EACH CORNER 1B, MIN SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION GrrKK tlrnrrterman, Peb1kE Wor4] AdminhSrilur PIPE ALLOWANCES MAXNaUM PIPE MATERIAL INSDE DIAMETER REINFORCED OR PLAIN 12., CONCRETE ALL METAL PIPE l5" CPSSP', 12' STD. SPEC 9•P5.N SOLID WALL PVC, STD SPEC-StS-1201 15" PROFILE WALL PVC, 15, STD. SPEC. 9I15.12(2} ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1 AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION. FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-45.500)), OR WIRE MESH HAVING A MINIMUM AREA OF 1112 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REOUIRED RESAR SHOWN IN THE ALTERNATNE PRECAST BASE SEC71 ON. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION. WIRE MESH HAVING A MINIMUM AREA OF (1.12 SQUARE INCHES PER fOOT MAY BE USED 2. THE KNOCKOUT DIAMETER S HALL NOT HE GREATER THAN 2d'. KN0CKOLITS SHALL HAVE A WALL TH3CKNFSS OF 2- MINIMUM TO 2.5- MAXIMUM. PROVIDE A 1.57 MtNIMUM GAP BETWEEN THE KNOCKOUT WALL ANO THE OUTSIDE OF THE PIPEAFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3_ THE MAXWUM DEPTH FROM THE FINISHED GRAOE TO THE LOWEST PIPE INVERT SHALL HE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DDW N. 5_ THE PRECAST BASE SECTION MAY HAVE A ROUNDED fL0OR_ AND THE WALLS MAY BE SLOPED AT A RATE OF , H:24V DR STEEPER, fi, THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BAst SECTION. 7• ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-$HR INK APPLI CATION$ 9N ACCORDANCE WITH STANDARD SPECIFICATION 9129.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET W MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 4-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIRE D AND APPLIED PER MANUFACTURER'S DIRECTIONS, 1D. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPNG UNTIL FRAME 15 FLUSH W17H PRVE.MENT AS DETERMINED WITH A STRAIGilT EDGE OF SUFFICIENT LENGTH 11. ALL MORTAR JOINTS SHALL HE TRIMMED FU51-1 AND REMAIN VISIBLE LIF'ON COMPLETION_ SM, PLAN - 200.00 PUBLIC WORKS APPIR ED DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 Io ua wakx a Jn, niai.io, DATE PER CITY COMMENTS SITE PLAN & DRAINAGE PER CITY COMMENTS REVISION :45 A 1 MIN 1 VARIES MIN MIN f MIN �zEClal_N_R� � I I` IN 111E EVENT TRANSVERSE PATCHES E,CIST I W NIN THE AFFECtILD STREET, THE LENGTH ICI OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN M FEET OF THE EDGE OF THE PATCH RFQUInE6 FOR THE NEW CROSSING AND ANY SUBSEOUENT PATCH EDGE WITHIN IQ FEET OF THE EDGE OF THE SECOND PATCH AND i { SO ON UP TO A TOTAL OF 300 FEET. 1 I I I TRAFFIC FLOW I I! 2" HMA + I ) 2' TO V HMA I I �I 8.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES. 8-5, MIN, 1 1' V 1' MIN I IMN VARIES I I MIN MIN 2 OR PLANE, SEAL WITH SAWCUT AND REMOVE AR - 4000W (EACH SIDE) 2" HMA SAWCUT AFTER BACKFILL - (EACH SIDE) 'MATH OF TRENCH AS OTSTANDARD REQUIRED BY SIZE CF PROPOSED PLUSAN ENTAL-L (SEE E FOR 5TANDARD SPECIFICATION 2-09.4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF WEEDED, SHALL MEET THE REOUIREMENM OF WSDOT STANDARD SPECIFICATION 7-M.XIl 8 TRENCH ,BOTH FACE OF GUTTER OR EOCE OF PAVEMENT CENTER UNE OR LANE LINE DEPTH OF EXISTING PAVEMENT 2" - 5" MIN. (SEE NOTE 2) 5' CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROC TOIL, CSTC, SANK RUN GRAVEL. FOR TRENCH BACKFILL GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINFER BASED ON CEOTECH REPORT, COMPACTED 7D 95% MODIFIED PROCTOR. PIPE ZONE BEDDING. MATERIAL- SEE STANDARD PLAN 110.1. FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR SM. PLAN - liD PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID i:' DEPARTMENT PAVEMENT WITH OVERLAY DocuSign E.rivelope ID: 6EECF5B6.602A4E4A-B436-A317AA638878 CLEAN SURFACE AND SOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECT[UN FRAME AND VANED GRATE ADJUSTMENT SECTION I � I � I I I I I � r BASE SECTION SEE NOTE A NOTES: I. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT. GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS C7VEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSOOTIAPWA STANDARD SPECIE IGATION 7.05.3. Z. SHIMS SHALL NOT 9E USED TO SET FRAME TO GRADE THE USE OF SHIM$ IS PROHIBITED, 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY SY APPROVAL OF THE CITY. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Yr SOND. 5_ BASE SECTION SHALL BE SEALED TO THE BOTTOM AREAOF THE ADJUSTMENT SECTION WITH MORTAR- 6- MORTAR SHALL MEET THE RIMUIREMENTS OF WSDOTIAPWA STANDARD SPECIFICATION 9,64.3. T PICK I LIFTING BOLES ARE TO BE GROUTED WATER TIGHT, USE GROUT TYPE 2 FOR NON•SHRINW APPLICATIONS JN ACCORDANCE WITH STANDARD SPECIFICATION 9.20.3(2) E. MORTAR SHALL BE MEXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. R- FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME iB FLUSH WITH PAVEMENT AE DETERMINED WITH A STRAIGHT EDGE OF SUFPICI ENT LENGTH. 10. ALL MORTAR JOINTS SWILL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. STI7, PLAN - 202.00 PRIPUBLIC WORKS jpsom; DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/29/2018 1 9 %67ivu;:waIx Jn.......... PATF CJA 03108124 SURVEYED: DBM NEM 08121118 DESIGNED: SS DRAWN: PS CHECKED: CA BY DATE AP P R APPROVED: CA SCALE: 1 "=201 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M :45 A VARIES; 4,5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EASTING PAVEMENT 2" - $" HMA (SEE NOTE 2} 1' E OF PAVEMENT, EDGE J EDGE 1' OF CURE & GUTTER, OR -j MIN. MIN. CENTER OF LAME MARKING 2" HMA {SEE NOTE 2} 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVESPECIFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-400OW CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03-19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEEI,' BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 95% MODIFIED PROCTOR. 0 PROPOSED IMPROVEMENT (SEE WSDOT 5TANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPAC IION A5 ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSDOT STANDARD SPECIFICATION 7•-08.3(1)B • rOR STORM AND WATER PIPE, PER STD PLAN 220.0 FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH FOR JOINT UTILITY TRENCH, SAND WITH 957. PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES: 1. WHEN EXISTING PAVEMENT IN A LANE RECUIRINC A FULL WIDTH REPLACEMENT IS 19ROKEN pR DE7ERICRATED TO A PAVEMENT CONDITJON INDEX RATING OF 7D OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2. PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL 4" PG 54-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS - HMA CL }" PG 64-22. THE: THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4"- 1 WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, 0LJR9 dr GUTTER OR SHOULDER, THE AFFECTED LANE SHALL 113E PLANED AND OVERLAID WITH HMA FULL WIDTH" THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK A.NO/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION ,JOINT TO EXPANSION JOINT_ 5, IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. - TYPICAL. LONGITUDINAL PATCH STD. PLAN 110.1 PUBLIC WORM FOR F'LEXiBLE PAVEMENT OR DEPARTMENT RIGID PAVEMENT WITH OVERLAY �� l Know what's beIow. Call before you dig. • CITY OF R EN TON • Planning/Building/Public Works Dept. CN/ 0. N N Q J R-428307 J IN COMPLIANCE WITH CITY OF RENTON STANDARDS EHHuy:nh ENT ENGINEERING 09/27/2024 'V Ji v i w 2E DATE: CD SIERRA HOMES SHORT PLAT 06/19/2024 = L U A 2 2- 0 0 0 31 5 FIELDBOOK: PAGE: DRAWING NO: CONSTRUCTION DETAILS I 21706 °LJ SHEET: 7 OF:10 C40 M w N I O W I- L:i m z Ld - DocuSign Envelope ID; 6EECF5B6-602A-4E4A-B43S-A317AA638878 CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204,00 HE OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4• MIN.7 28' MAX 16' MAX. FLAT SLAB TOP 48", SC 60•, 72 96", 120" OR 144E SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE _ STEPS OR LADDER 1T(rYP_y o I. MIN. 2 'O" RING r 2.5' MAX. T REINFORCING STEEL, (TYP.) MIN . 12" MAX 1T GRAVEL BACKFILL FQR PIPE ZONE 12' BEDDING PER WSOOT STD. SPEC: DH SECTION 9.03.12(3) S. 0. SEPARATE BASF INTEpRAL BASE PRECAST PRECAST WITH RISER NOTES- 1. NO STEPS ARE REQUI RED WHEN HEIGHT IS 4' DR LESS. L THE BOTTOM OF THE PRECAST CATCn BASIN MAY BE SLOPED TO FACILITATE CLEANING 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTME HT SECTION. 4 KNOCKOUTS SHALL HAVE A WALL THICKNESS OF T MINIMUM TO 2.5E MAXIMUM. PROVIDE A 1.6MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JDINT MORTARIN ACCORDANCE WITH STANDARD SPECIFICATION 9L04.3 5. ALL GRADE RINGS, RISERS, ANO CASTINGS SHALL BE SET IN MORTAA IN ACCORDANCE WITH STANDARD SPECIFICATION 5-N-3 6. WHEN CONNECTING TO A NEOV PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL 1300T WITH COR RUGATEO PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TD AN EXISTING PIPE, 115E A FABRJCATEO SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7 MORTAR SHALL BE MJXEDANDAPPLIED PER MANUFACTURER'S DIRECTIONS. B. FRAME 5HALL BE ADJuSTE0 TO PAVEMENT GRADE BY TAPPING UNTI L FRAME IS FLUSH WITA PAVEMENT AS DETERMINED WITH A STFWCHT EDGE OF SUFFICIENT LENGTH. 9_ ALL MORTAR JOINTS SHALL BE TRIMMED PLusH AND REMAIN VISIBLE UPON COMPLETEON. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48' 4- 6• 86" 6" 5V 4.5" 8• 42" V 60" 5" a" 48" a• 7T 67 Ie" 90' 17' &C a' IV- 1-12' 12' 12• 1 1. 12• 120" IT 1T W. 12' 144' 12" 1T 10R• 12' PIPE ALLOWANCES CATCH WIN PIPE MATERIAL WITK MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP' SOLID WALL PVC' PROFILE WALL PVC' As' 24" 30" 24' 30' 30' 64" 3T 36' 30" 36, 36" 60' 36" 42' 3V 42' 42" 72" 1 42" se 42' 48• 48" 54' 54' 61r 54' 48' 48" 96' W.1 72' 60- 48' 4a" 12T 1. Ew 60' 46. 48" 144' 79" 56" 60' 48" 48" 'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-OS 2a) - STD. SPEC. 9-05.i2S1 i ' STO. SPEC. 9-M.12(21 UNLESS (11W RVIISE NOTED, DRAwrNG 15 NOT TO $CALP I NYSI STD, PLAN - 201.00 PUBLIC WORKS PR DEPARTMENT CATCH BASIN TYPE 2 GAZ 9/28/2018 �e6[ wab ean,nloraim DAT F DocuSign Envelope ID: 3B1B34D3-7EDA-476C-ADB3-4329FFEOC108 PRIVATE ROOF DRAIN COLLECTOR PIPE; 6" DIA MIN. ROOF DRAIN STUB WITH CLEANOUT (TYP.) LOT LINE, TYP. 6" DIA MIN., PRIVATE TYPE 1 0.5 % MIN. SLOPE, 5' MIN. CATCH BASIN 2 FT MIN. COVER ITyP.) HOUSE (TYP.) S MIN. PRIVATE JOINT SD ® SO SD SO UTILITY EASEMENT CURB, SIDEWALK CITY STORM DRAIN (SD) SYSTEM 5' MIN. WIDTH R.O.W. LINE PRIVATE STORM DRAIN (SD) SYSTEM, 8" MIN. DIA. PIPE, SEE NOTE 1 ROOF DRAIN TO CONNECT INTO CITY CATCH BASIN (CB), MIN. SIZE TYPE I CLEANOUT, TYP AT EVERY 90°, OR 2ND 45' BEND, AND AT 100' MAX. SPACING ON STRAIGHT SECTIONS NOTES: 1. SEE STD. PLANS 220.00 AND 220.10 FOR PIPE MATERIALS AND MINIMUM COVER REQUIREMENTS. 2. THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED. 3. FLOW PATTERN SHOULD BE TO THE NEAREST CB IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CB. 4. ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY, SIZED FOR 25-YEAR PEAK FLOW. 5. PVC PIPE MUST BE SDR 35 OR THICKER AND MEET THE REQUIREMENTS OF ASTM D3034. 6. PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR. 7. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 8. AREA DRAIN WITHIN CRAWL SPACE IS ALLOWED TO CONNECT INTO THE STORM DRAINAGE SYSTEM WITH THE FOLLOWING CONDITIONS: A. THE CONNECTION IS TO BE TIGHT LINED A MINIMUM OF 10' OUTSIDE OF THE FOUNDATION, AND IN NO CASE CONNECTED UPSTREAM OF THE FOOTING DRAIN SYSTEM FOR THE HOUSE. B. THE AREA DRAIN MUST BE ROUTED THROUGH A SUMP PUMP SYSTEM PRIOR TO CONNECTION TO THE PUBLIC STORM DRAINAGE SYSTEM TO HELP PREVENT BACKUP DURING SURCHARGE CONDITIONS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 225.00 PUBLIC WORKS TYPICAL PRIVATE STORM DRAIN ��40edby: _O�• �I� DEPARTMENT L8/13/20 COLLECTION SYSTEM Aartipn Pastucha &�Y�J.d��`yQawAD... DATE VASIV :4' A 0 18 A EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 DocuSign Envelope ID 345EI6810-914F-4F2D-AS69-7C192fl3B78A3 {� EX. SEWER MAIN r I I I i i I PROPERTY LINE SPOOL I I Z �(LENG7H I AS NEEDED) I i I II o J'-O' I MIN fi" SCWER STUB I I I 1 I 1 � FUTURE 4" SIDE SEWER I I I I I I T'm 4" STUD MARKING POST PAINTED I I I I ! 6' CAP J "iITE WTH THE WORD 'SEWER' STENCILED SEWER MAIN TEE x 6" TEE I I I I IN 3" HIGH BLACK LETTERS ANp $6 WIRE SIDEWALK WRAPPED AROUND THE STUD AND i { 7 EXTENDED TO THE TOP OF THE .STVD COUPLING (TYP ) 'L --------- t 6"X6"X5" SURFACE CLEANOUT WTH CAST IRON RING AND COVER (EAST JORGAN IRON WORKS PRODUCT NO 00367502 OR .'- APPROVED EQUAL, SPECIFY "SEYr'ER- ON uq). [7 CLEANOUT TO BE CENTERED IN A 2'x7' CONCRETE PAID I az CONCRETE PAD TO BE 9' IN DEPT++ rT- L___1 BE�+Q As �_ a. REQUIRED EXISTING SANITARY 01f, yM SEWER MAIN ^� SLOPE +l lj ♦ ` L-UTURE 4' SIDE SEWER SEWER STUB �fi"x 8"X6' WYE LFUTURE B"x 4" REDUCER SEWER MAIN SIZE X 8" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTioNS TO EMSTING SEWER MAIN A VITRIFIED CLAY A1AIN - CUT IN A NEW PVC "TEE` USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). 8 CONCRETE MAIN - CUT IN A NEW PVC "TEE' USING "STRDNQ-$ACK' FLEXIBLE COUPLINGS ("NCO OR APPROVED EQUAL) C PVC k C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE-ORRLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTiON TO SEWER MAINS THAT HAVE BEEN LINE[) (CIPP, ETC ), CUT IN A NEW PVC 'FEE" US1NC '$TRONG-BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HOPE - CORE-DRILLEID WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12' DIAMETER OR I-ARCER G MANHOLE CONNEC'nON - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -CUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL 80015 OR APPROVE[) EQUAL WITES- 1 PRIOR TO INSTALLAThON OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST K PURCHASED FROM THE ❑TY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWSE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5• CODER AT PROPERTY LINE OR 3-5' LONER 7ifAN THE LOWEST HOUSE ELEVATION, WICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 R SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTIOk Or THE SIDE SEWER STUB, CAUL 2+ HOURS IN ADVANCE. THE INSPECTION PRONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTEE) TIME DO NOT BACKFILL THE TRE:gCII UNTIL APPROVAL 15 OWN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2 8 THE SIDE SEWER STUB SHALL HAVE PIPE 8E00'NC IN ACCORDANCE- WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS S1•ALL BE INSTALLEE; EY A CONTRACTOR LICENSED AND BONDED IN THE STATE Or WASHINCTON SIDE SEWER STUB STD. PLAN •406.1 APP� PUBLIC DEPARTMENT INSTALLATION DEPARTh7€NT Martin PastuchOV26/20" (SEWER MAIN TO PROPERTY LINE) DAT' DocuSign Envelope ID: 3B1B34D3-7EDA-476C-ADB3-4329FFEOC108 3/4" FLAT FACE GOTHIC ♦MP'" 9" DIA 5l " ❑❑ y❑ ❑ ❑ ❑ STORM ❑ 4" ❑❑❑❑ q ❑❑ 1/a" DIA h. 418.-, 1/2" DIA (2) 3/8"-16 SS SOCKET HEAD CAP 5" DIA (1) OPEN PICKHOLE 1" SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE PLAN VIEW FRAME SECTION CAST IRON FRAME AND COVER, SEE NOTE 3 - 8" CLASS "B" ASPHALT. SEE NOTE 4 CLEANOUT RISER, SEE NOTE 2 SOIL TIGHT 45° BEND WYE SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 � r� TO OVERFLOW STRUCTURE OR STORM MAIN 8-13/16" DIA PAVED AREA (TYP.) EXTEND CLEANOUTRISER 2" ABOVE DESIGNSIGNPONDING . a ELEVATION OR PER PLAN FERNCO GASKETED DESIGN PONDING QUIK CAP OR SIMILAR %V ELEVATION 4"STREAM13ED COBBLES PER WSDOT 9-03.11(2) 4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) F (_�-� III=111-III-Ili.- II III lEi i l l- I` CLEANOUT RISER, I I - SEE NOTE 2 -'- - ,.�IF III Ell ll B-I _ j:=7i i itti I I � I I � CLEANOUT RISER LOCATED WITHIN "'�k'/,�/✓/� -MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION BIORETENTION PONDING AREA NOTES: 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME, CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 226.00 off" PUBLIC WORKS ORO%h dby: ' DEPARTMENT STORM SYSTEM CLEANOUT Aart�iin Pastucha 8/13/20 6Fpy.1'',rpb,y,Q9D... DATE I PER CITY COMMENTS SITE PLAN & DRAINAGE PER CITY COMMENTS REVISION 0 I 8: DocuSign Envelope ID: 3B1B3403-7EDA-476C-AD83-4329FFEOCiOB ROOF DOWNSPOUT WITH OVERFLOW WYE AND SPLASH BLOCK PERFORATED PIPE TO BE LEVEL FLEXIBLE GA9iiETEO CLEANOUT CAP PER ASTM DFi928 PER STD. PLAN ZMLOO B' MIN fl" MIN. L TWIN 12D 0.. 12, SDR 35 PER ASTM 03034 2f4-T01-112- WAS1+Ep DRAIN ROCK 6. OIA. MIN. PERFORATED PVC. OR GRAVEL BACKFILI, FOR SOR 35 PER ASTM 0_14YJ4 ORYWELLS PER WSOOT STD FINE MESH SCREEN. SS304 1 OX10 DR 51MILAR SPECIFICATION SECTKA 84)3.12(5) ELEVATION COMPACTED BACKFILL G'r�si IH' 6" DIA. MIN PERFORATED PVC. �__ SDR. 35 PER ASTM D3034ON G MI N. NONWOVEN GEOTF][TILE FOR SEPARATION ON TOP AND SIOfS OF 7RENQH PER WSDOT SPECIFICATIONS SECTION 9-" �(1) TABLE 3 12• MIN 12" MIN. ABOVE SEASONAL H ISM 2d' MIH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER SECTIdN A NOTES: 1. 15' h41NIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS. OR ELEVATIONS BELOW THEOVERFLOW POINT. 2. REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 1W MAX. WHEN LOCATED IN COARSE SANDS OR CODDLES. INFILTRATION TRENCHES MUST BE AT LEAST 2e IN LENGTH PER 1.000 SQUARE FEET Of IMPERVrwS SURFACE SEIRVW. WHEN LOCATED IN MEDIUM SANDS. I NF I LTRATION TRENCHES MUST HE AT LEAST 30' IN LENGTH PER LOUD SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REOUIREMENITS, UNLESS OTHERWISE NOTED. DRAWING 6 NOT TO SCALE INTS) STD. PLAN - 225.20 ti PUBLIC WORKS SINGLE FAMILY ROOF DOWNSPOUTjame"mcd"Y: 8j13/2a2 DEPARTMENT INFILTRATION TRENCH Wartin Pastucha BATi DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3678A3 WASTEWATER UTILITY STANDARD NOTES 1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION 2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS 3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS, INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION 4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY 5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES 7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). 8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35, C90O/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY 9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC) UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412 10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY 11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS 8 SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405 12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL 13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR ST ,PLAN - 413 �p PUBLIC WORKS WASTEWATER UTILITY APPROVED S DEPARTMENT Martin PastuchaLO/26/2 STANDARD NOTES DATE CJA 03108124 SURVEYED: DBM NEM 08121118 DESIGNED: SS DRAWN: CHECKED: CA BY DATE APPR APPROVED: CA SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL NAD 1983/1991 DATU M 18: M N L^ NJ CM) \' J N R-428308 S-428302 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING O HHuynh 09/27/2024 V J Know what's below. WASTEWATER UTILITY I� Call before you dig. jstowell 09/27/2024 DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = CITY OF L U A 22-00031 5 Q 0 FIELDBOOK: RENTON PAGE: DRAWING N0: Planning/Building/Public Works Dept. CONSTRUCTION DETAILS II 21706 W SHEET: Q OF: 10 V) 0 C'7 CD N W c•••r� Iy Z J L, PROJECT SUMMARY CALCULATION DETAILS • LOADING = HS20/HS25 • APPROX. LINEAR FOOTAGE = 111 LF STORAGE SUMMARY • STORAGE VOLUME REQUIRED = 4,095 CF • PIPE STORAGE VOLUME = 3,138 CF • BACKFILL STORAGE VOLUME = 1,029 CF • TOTAL STORAGE PROVIDED = 4,168 CF PIPE DETAILS • DIAMETER = 72" • CORRUGATION = 5xl GAGE = 16 • COATING =ALT2 • WALL TYPE = PERFORATED • BARREL SPACING = 36" BACKFILL DETAILS • WIDTH AT ENDS = 12" • ABOVE PIPE = 0" • WIDTH AT SIDES = 12" • BELOW PIPE = 0"-0" 4 NOTES LA I • ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER OF RECORD PRIOR TO RELEASING FOR FABRICATION. • ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998. • ALL RISERS AND STUBS ARE 2%" x )/2" CORRUGATION AND 16 GAGE UNLESS OTHERWISE NOTED. • RISERS TO BE FIELD TRIMMED TO GRADE. • QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR. • BAND TYPE TO BE DETERMINED UPON FINAL DESIGN. • THE PROJECT SUMMARY IS REFLECTIVE OF THE DYODS DESIGN, QUANTITIES ARE APPROX. AND SHOULD BE VERIFIED UPON FINAL DESIGN AND 5 APPROVAL. FOR EXAMPLE, TOTAL EXCAVATION DOES NOT CONSIDER ALL VARIABLES SUCH AS SHORING AND ONLY ACCOUNTS FOR MATERIAL WITHIN THE a ESTIMATED EXCAVATION FOOTPRINT. • THESE DRAWINGS ARE FOR CONCEPTUAL PURPOSES o AND DO NOT REFLECT ANY LOCAL PREFERENCES OR ASSEMBLY REGULATIONS. PLEASE CONTACT YOUR LOCAL CONTECH REP FOR MODIFICATIONS. SCALE: 1" _ 10' PROJ31062 : SE45IN DATE: ® \I//�uTCwu® ..- .-� DY045199 Sierra Homes Short Plat "DB2 45,99 are2024 DESIGNED: DYO DRAWN: Dvo w inM N, h�mdua'm:awSealm°%tin•^• v CONTECH"' ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS Detention System G n� •"nq��.a i„I°,mne^upn Mi'A www.ContechES.com CONTECH Issaquah, WA CHECKED: DVG A➢PROVED: DYO o ' 9025 Centre Pointe Dr., Suite 400, West Chester, OH 4506' DYODS DRAWING DETENTION SYSTEM DATE REVISION DESCRIPTION BY 38-1122 513-645-7000 513-645-7 eooa as3FAX SHEET NO: 1 TEMPORARY COVER FOR CONSTRUCTION LOADS HEIGHT OF COVER FINISHED GRADE CONSTRUCTION LOADS FOR TEMPORARY CONSTRUCT ON VEHICLE LOADS, AN EXTRAAMOUNT OF COMPACTED COVER MAY BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT -OF -COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED GRADE COVER MINIMUMS FOR NORMAL HIGHWAY TRAFFIC. PIPE SPAN, AXLE LOADS (kips) INCHES 18-50 50-75 1 75-110 110-150 MINIMUM COVER (FT) 2.0 2.5 3.0 3.0 12-42 48-72 3.0 3.0 3.5 4.0 78-120 3.0 3.5 4.0 4.0 126-144 3.5 4.0 4.5 4.5 "MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM SCALE: N.T.S. A ACCESS CASTING TO BE PROVIDED AND INSTALLED BY CONTRACTOR. q 1O d a d GASKET MATERIAL °CMP RISER J SUFFICIENT TO PREVENT a SLAB FROM BEARING ON o RISER TO BE PROVIDED BY a - CONTRACTOR. GB 11"TYP. rn SECTION VIEW O eA #4 DIAGONAL TRIM BAR (TYP. 4 PLACES), SEE NOTE 7. l O G c OPENING IN PROTECTION SLAB FOR CASTING SCOPE PIPE THIS SPECIFICATION COVERS THE MANUFACTURE AND INSTALLATION OF THE PIPE SHALL BE MANUFACTURED IN ACCORDANCE TO THEAPPLICABLE THE DESIGNED DETENTION SYSTEM DETAILED IN THE PROJECT PLANS. REQUIREMENTS LISTED BELOW: MATERIAL ALUMINIZED TYPE 2: AASHTO M-36 OR ASTM A-760 THE MATERIAL SHALL CONFORM TO THE APPLICABLE REQUIREMENTS LISTED BELOW: GALVANIZED: AASHTO M-36 OR ASTM A-760 ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE POLYMER COATED: AASHTO M-245 OR ASTM A-762 REQUIREMENTS OF AASHTO M-274 OR ASTM A-92. ALUMINUM: AASHTO M-196 ORASTM B-745 THE GALVANIZED STEEL COILS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS OF AASHTO M-218 OR ASTM A-929. HANDLING AND ASSEMBLY SHALL BE IN ACCORDANCE WITH NCSP'S (NATIONAL CORRUGATED STEEL THE POLYMER COATED STEEL COILS SHALL CONFORM TO THE PIPE ASSOCIATION) FOR ALUMINIZED TYPE 2, GALVANIZED OR POLYMER REQUIREMENTS OF AASHTO M-246 OR ASTM A-742. COATED STEEL. SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS FOR ALUMINUM PIPE. THE ALUMINUM COILS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS OF AASHTO M-197 OR ASTM B-744. INSTALLATION SHALL BE IN ACCORDANCE WITH AASHTO STANDARD SPECIFICATIONS FOR CONSTRUCTION LOADS HIGHWAY BRIDGES, SECTION 26, DIVISION II DIVISION II OR ASTM A-798 (FOR CONSTRUCTION LOADS MAY BE HIGHER THAN FINAL LOADS. FOLLOW THE ALUMINIZED TYPE 2, GALVANIZED OR POLYMER COATED STEEL) OR ASTM MANUFACTURER'S OR NCSPA GUIDELINES. B-788 (FORALUMINUM PIPE)AND IN CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. IF THERE ARE ANY INCONSISTENCIES OR CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE WITH THE SITE ENGINEER. NOTE: THESE DRAWINGS ARE FOR CONCEPTUAL IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW OSHA PURPOSES AND DO NOT REFLECT ANY LOCAL GUIDELINES FOR SAFE PRACTICES. PREFERENCES OR REGULATIONS. PLEASE CONTACT YOUR LOCAL CONTECH REP FOR MODIFICATIONS. Encomr)ass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 It Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 It Phone: (509) 674-7433 INTERRUPTED BAR REPLACEMENT, SEE NOTE 6. #4 DIAGONAL TRIP BAR (TYR 4 PLACES SEE NOTE-, 2" COVER (TYP) �I t OPENING I PROTECTIO SLAB FOI CASTINI REINFORCING TABLE —BEARING 0 CMP RISER A 0 B REINFORCING PRESSURE (PSF) 24" 0 4' 26" #5 @ 12" OCEW 2,410 4'X4' #5 @ 12" OCEW 1,780 o 4'1" 32 #5 @ 12" OCEW 2,120 4'-6" X 4'-6" #5 @ 12" OCEW 1,530 36 .5' 5' 38 #5 @ 10" OCEW 1,890 X 5' ifs @ 10" OCEW 1,350 42" 0 V-6" 5'-6" 44" #5 @ 10" OCEW 1,720 X 5'-6" #5 @ 9" OCEW 1,210 48" e 6' 6' S06' #5 @ 9" OCEW 1,600 X #5@8"OCEW 1,100 "" ASSUMED SOIL BEARING CAPACITY \\ STANDARD STANDARD \t v— REINFORCING, REINFORCING, y eB INTERRUPTED BAR SEE TABLE SEE TABLE REPLACEMENT, SEE NOTE 6. ROUND OPTION PLAN VIEW SQUARE OPTION PLAN VIEW NOTES: 1. DESIGN IN ACCORDANCE WITH AASHTO, 171h EDITION. 7. TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND BARS MINIMUM OF 12" BEYOND OPENING, BEND 2. DESIGN LOAD HS25. BARS AS REQUIRED TO MAINTAIN BAR COVER. 3. EARTH COVER = 1' MAX. 8. PROTECTION SLAB AND ALL MATERIALS TO BE PROVIDED AND INSTALLED BY CONTRACTOR. 4. CONCRETE STRENGTH = 3,500 psi 9. DETAIL DESIGN BY DELTA ENGINEERING, BINGHAMTON, NY. 5. REINFORCING STEEL= ASTM A615, GRADE 60. 6. PROVIDE ADDITIONAL REINFORCING AROUND MANHOLE CAP DETAIL OPENINGS EQUAL TO THE BARS INTERRUPTED, HALF EACH SIDE. ADDITIONAL BARS TO BE IN THE SAME PLANE. SCALE: N.T.S. IL CMP DETENTION SYSTEMS CONTECH DYODS DRAWING r I PER CITY COMMENTS 2 SITE PLAN & DRAINAGE PER CITY COMMENTS REVISION CJA 03108124 SURVEYED: DBM NEM 08121118 DESIGNED: SS DRAWN: PS CHECKED: CA BY DATE AP P R APPROVED: CA TABLE 1: DIAMETER, D MIN. COVER CORR. PROFILE W-10" 12" 1 1/2" x 114" 12"-48" 12" 2 2/3"x 1/2" >48"-96" 12" 3" x 1", 5" x 1" >96" D/8 3" x 1", 5" x 1" • STRUCTURAL BACKFILL MUST EXTEND TO LIMITS OF THE TABLE • TOTAL HEIGHT OF COMPACTED COVER FOR CONVENTIONAL HIGHWAY LOADS IS MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT. TRENCH 1�FILL ENVELOPE EMBANKMENT MINIMUM WIDTH DEPENDS ON SITE CONDITIONS AND ENGINEERING JUDGEMENT INSTALLATION NOTES 1. WHEN PLACING THE FIRST LIFTS OF BACKFILL IT IS IMPORTANT TO MAKE SURE THAT THE BACKFILL IS PROPERLY COMPACTED UNDER AND AROUND THE PIPE HAUNCHES. 2. OTHERALTERNATE BACKFILL MATERIAL MAY BE ALLOWED DEPENDING ON SITE SPECIFIC CONDITIONS, AS APPROVED BY SITE ENGINEER. 3. AN HDPE MEMBRANE LINER WILL BE PLACED ON THE CROWN OF EACH PIPE TO PROVIDE AN IMPERMEABLE BARRIER AGAINST ENVIRONMENTAL CHANGES THAT MAYADVERSELY AFFECT THE SYSTEM OVER TIME. PLEASE REFER TO THE CORRUGATED METAL PIPE DETENTION DESIGN GUIDE FOR ADDITIONAL TECHNICAL DETAILS. CMP RETENTION STANDARD BACKFILL SPECIFICATIONS MATERIAL LOCATION MATERIAL SPECIFICATION DESCRIPTION MINIMUM TRENCH WIDTH MUSTALLOW ROOM FOR PROPER COMPACTION OF MINIMUM EMBANKMENT WIDTH (IN FEET) FOR INITIAL FILL ENVELOPE: HAUNCH MATERIALS UNDER THE PIPE. PIPE <24": 3.OD FILL ENVELOPE WIDTH PER ENGINEER OF RECORD THE SUGGESTED MINIMUM TRENCH WIDTH, OR FOR RECOMMENDATION: .OD PIPE 24"- 144": PIPE15 12": D + 16" PIPE > 144" D + 10'0" PIPE > 12": 1.5D + 12" FOUNDATION AASHTO 26.5.2 - PER ENGINEER OF RECORD PRIOR TO PLACING THE BEDDING, THE FOUNDATION MUST BE CONSTRUCTED TO A UNIFORM AND STABLE GRADE. IN THE EVENT THAT UNSUITABLE FOUNDATION MATERIALS ARE ENCOUNTERED DURING EXCAVATION THEY SHALL BE REMOVED AND FOUNDATION BROUGHT BACK TO GRADE WITH A FILL MATERIAL APPROVED BY THE ENGINEER OF RECORD. ENGINEER OF RECORD TO DETERMINE IF BEDDING IS REQUIRED. PIPE MAY BE PLACED ON THE TRENCH BOTTOM OF A RELATIVELY LOOSE, NATIVE SUITABLE WELL GRADED GRANULAR BEDDING AASHTO M 43: 3, 357, 4, 467, 5, 56, 57 MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE BOTTOM OF THE PIPE, 2" MIN DEPTH. THE BEDDING MATERIAL MAY BE SUITABLE OPEN GRADED GRANULAR BEDDING CONFORMING TO AASHTO SOIL CLASSIFICATIONS Al, A2, ORA3 WITH MAXIMUM PARTICLE SIZE OF 3" PER AASHTO 26.3.8.1 CORRUGATED METAL PIPE HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION WITHOUT SOFT SPOTS. BACKFILL SHALL BE PLACED IN 8" -1- NI AN LA A SE LIFTS AND COMPACTED TO 90% STANDARD PROCTOR PER AASHTO T 99. BACKFILL SHALL BE PLACED SUCH THAT THERE IS NO MORE THAN A TWO LIFT (16") DIFFERENTIAL BETWEEN BACKFILL M 3, , 4, 5, 57 OR APPROVED NY OF THE PIPES AT ANYTIME DURING THE BACKFILL PROCESS. THE BACKFILL SHOULD BE ADVANCED ALONG THE LENGTH OF THE SYSTEM TO AVOID DIFFERENTIAL LOADING. WHERE EQUAL" CONVENTIONAL COMPACTION TESTING IS NOT PRACTICAL, THE MATERIAL SHALL BE MECHANICALLY COMPACTED UNTIL NO FURTHER YIELDING OF MATERIAL IS OBSERVED UNDER THE COMPACTOR. "IN AREAS WITH HIGH WATER TABLE FLUCTUATIONS THAT INTERACT WITH THE PIPE ZONE, CONSIDER INSTALLING A GEOTEXTILE SEPARATION LAYER TO PREVENT SOIL MIGRATION. COVER MATERIAL UP FO MIN. COVER -AASHTO M 145: A-1, A-2, A3 ABOVE COVER MATERIAL MAY INCLUDE NON -BITUMINOUS, GRANULAR ROADBASE MATERIAL WITHIN MIN COVER LIMITS MIN. COVER - PER ENGINEER OF RECORD RIGID OR FLEXIBLE PAVEMENT (IF PER ENGINEER OF RECORD FLEXIBLE PAVEMENT SHOULD NOT BE COUNTED AS PART OF THE FILL HEIGHT OVER THE CMP. FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS SHALL FOLLOW THE APPLICABLE) PROJECT PLANS AND SPECIFICATIONS PER THE ENGINEER OF RECORD. OPTIONAL SIDE GEOTEXTILE NONE GEOTEXTILE LAYER IS RECOMMENDED ON SIDES OF EXCAVATION TO PREVENT SOIL MIGRATION. GEOTEXTILE BETWEEN LAYERS NONE IF SOIL TYPES DIFFER ATANY POINTABOVE PIPE INVERT, A GEOTEXTILE LAYER IS RECOMMENDED TO BE PLACED BETWEEN THE LAYERS TO PREVENT SOIL MIGRATION. NOTES: • FOR MULTIPLE BARREL INSTALLATIONS, THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE RUNS SHALL BE THE PIPE DIAMETER /2 BUT NO LESS THAN 12" FOR DIAMETERS <72". FOR 72" AND LARGER DIAMETERS, THE MINIMUM SPACING IS 36". CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING. " APPROVED REGIONAL EQUIVALENTS FOR SECTION 5 INCLUDE CA-7, MIDOT 6AA, 6A, OR 5G, PROVIDED THEY MEET THE PARTICLE SIZES INDICATED. MANUFACTURER RECOMMENDED BACKFILL NOT TO SCALE �I7� • w I/�VTCwV® PROs1G.: SE45IN DAE: _ V DY045199 Sierra Homes Short Plat NEE: 45199 382024 C� NTECH DESIGNED DRAWN ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS Detention System DYO Dvo www.ContechES.com Issaquah, WA CHECKED: A➢PROVED: po„"nm CONTECH DVG DYO 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 DYODS 800-338-1122 513-645-7000 513-645-7993 FAX DRAWING DETENTION SYSTEM SHEET NO: DATE REVISION DESCRIPTION BY 1 CMP DETENTION SYSTEM INSPECTION AND CMP DETENTION INSTALLATION GUIDE IN -SITU TRENCH WALL MAINTENANCE WHEN FLOWABLE FILL IS USED, YOU MUST PREVENT PIPE FLOATATION. PROPER INSTALLATION OF A FLEXIBLE UNDERGROUND DETENTION SYSTEM IF EXCAVATION IS REQUIRED, THE TRENCH WALL NEEDS TO BE CAPABLE OF TYPICALLY, SMALL LIFTS ARE PLACED BETWEEN THE PIPES AND THEN UNDERGROUND STORMWATER DETENTION AND INFILTRATION SYSTEMS MUST WILL ENSURE LONG-TERM PERFORMANCE. THE CONFIGURATION OF THESE SUPPORTING THE LOAD THAT THE PIPE SHEDS AS THE SYSTEM IS LOADED. IF ALLOWED TO SET-UP PRIOR TO THE PLACEMENT OF THE NEXT LIFT. THE BE INSPECTED AND MAINTAINED AT REGULAR INTERVALS FOR PURPOSES OF SYSTEMS OFTEN REQUIRES SPECIAL CONSTRUCTION PRACTICES THAT SOILS ARE NOT CAPABLE OF SUPPORTING THESE LOADS, THE PIPE CAN DEFLECT. ALLOWABLE THICKNESS OF THE CLSM LIFT IS A FUNCTION OF A PROPER PERFORMANCE AND LONGEVITY. DIFFER FROM CONVENTIONAL FLEXIBLE PIPE CONSTRUCTION. CONTECH PERFORM A SIMPLE SOIL PRESSURE CHECK USING THE APPLIED LOADS TO BALANCE BETWEEN THE UPLIFT FORCE OF THE CLSM, THE OPPOSING WEIGHT OF THE PIPE, AND THE EFFECT OF OTHER RESTRAINING INSPECTION ENGINEERED SOLUTIONS STRONGLY SUGGESTS SCHEDULING A DETERMINE THE LIMITS OF EXCAVATION BEYOND THE SPRING LINE OF THE MEASURES. THE PIPE CAN CARRY LIMITED FLUID PRESSURE WITHOUT PRE -CONSTRUCTION MEETING WITH YOUR LOCAL SALES ENGINEER TO OUTER MOST PIPES. PIPE DISTORTION OR DISPLACEMENT, WHICH ALSO AFFECTS THE CLSM INSPECTION IS THE KEY TO EFFECTIVE MAINTENANCE OF CMP DETENTION DETERMINE IF ADDITIONAL MEASURES, NOT COVERED IN THIS GUIDE, ARE LIFT THICKNESS. YOUR LOCAL CONTECH SALES ENGINEER CAN HELP SYSTEMS AND IS EASILY PERFORMED. CONTECH RECOMMENDS ONGOING, IN MOST CASES THE REQUIREMENTS FOR ASAFE WORK ENVIRONMENT AND DETERMINE THE PROPER LIFT THICKNESS. ANNUAL INSPECTIONS. SITES WITH HIGH TRASH LOAD OR SMALL OUTLET APPROPRIATE FOR YOUR SITE. PROPER BACKFILL PLACEMENTAND COMPACTION TAKE CARE OF THIS CONCERN. CONTROL ORIFICES MAY NEED MORE FREQUENT INSPECTIONS. THE RATE AT BACKFILL- WELLGRADED WHICH THE SYSTEM COLLECTS POLLUTANTS WILL DEPEND MORE ON SITE FOUNDATION LIVE LOAD t..UTARANDSMALLER STAGE POURSAS REQUIREDTO SPECIFIC ACTIVITIES RATHER THAN THE SIZE OR CONFIGURATION OF THE CONSTRUCTA FOUNDATION THAT CAN SUPPORT THE DESIGN LOADING CO NTROLFLOATATIONAND PIPE SYSTEM. \ APPLIED BY THE PIPE AND ADJACENT BACKFILL WEIGHT AS WELL AS MAINTAIN EMBANKMENT DISTORTIONMISPLACEMENT \ cLSM ITS INTEGRITY DURING CONSTRUCTION. INSPECTIONS SHOULD BE PERFORMED MORE OFTEN IN EQUIPMENT GEOTEXTILE SERA ON EMBANIOAENT WASHDOWN AREAS, IN CLIMATES WHERE SANDING AND/OR SALTING IF SOFT OR UNSUITABLE SOILS ARE ENCOUNTERED, REMOVE THE POOR SOILS \.�/ \ \ \ \,\ �, \ \' �; \r \ (ABOVE ABOADBELOWWITH UNIFORMLY / OPERATIONS TAKE PLACE, AND IN OTHER VARIOUS INSTANCES IN WHICH ONE DOWN TO A SUITABLE DEPTH AND THEN BU ILD UP TO THE APPROPRIATE�i��i ��i��i/T�/i///% BEDDING)\� �\ GRADED BEDDING LAYER. ./ /j '' WOULD EXPECT HIGHER ACCUMULATIONS OF SEDIMENT OR ABRASIVE/ ELEVATION WITH A COMPETENT BACKFILL MATERIAL. THE STRUCTURAL FILL BEDDING-WELLGRADED� / \i/ - \ CORROSIVE CONDITIONS. A RECORD OF EACH INSPECTION IS TO BE MATERIAL GRADATION SHOULD NOTALLOW THE MIGRATION OF FINES, WHICH GRANULARAND SMALLER \ //\T \ MAINTAINED FOR THE LIFE OF THE SYSTEM CAN CAUSE SETTLEMENT OF THE DETENTION SYSTEM OR PAVEMENT ABOVE. WEIGHTED PIPE WITH MOBILE IF THE STRUCTURAL FILL MATERIAL IS NOT COMPATIBLE WITH THE CONCRETE BARRIERS UNDERLYING SOILS AN ENGINEERING FABRIC SHOULD BE USED AS BACKFILL PLACEMENT (OR OTHER REMOVABLE WEIGHTS) MAINTENANCE SEPARATOR. IN SOME CASES, USING ASTIFF REINFORCING GEOGRID REDUCES OVER EXCAVATION AND REPLACEMENT FILL QUANTITIES. CMP DETENTION SYSTEMS SHOULD BE CLEANED WHEN AN INSPECTION MATERIAL SHALL BE WORKED INTO THE PIPE HAUNCHES BY MEANS OF REVEALS ACCUMULATED SEDIMENT OR TRASH IS CLOGGING THE DISCHARGE GEOGRID USEDTO REDUCE BACKFILL COVER SHOVEL -SLICING, RODDING, AIR TAMPER, VIBRATORY ROD, OR OTHER EFFECTIVE THEAMOUNTOF UNDERCUT GEOGRIDWASNTUSED METHODS. CONSTRUCTION LOADING ORIFICE. / �\\E.EANKMENT MAXIMUM UNBNANCE LIMITED ACCUMULATED SEDIMENTAND TRASH CAN TYPICALLY BE EVACUATED T021-1—(APPROX.1s) TYPICALLY, THE MINIMUM COVER SPECIFIED FORA PROJECTASSUMES H-20 THROUGH THE MANHOLE OVER THE OUTLET ORIFICE. IF MAINTENANCE IS NOT EMBANKMENT LIVE LOAD. BECAUSE CONSTRUCTION LOADS OFTEN EXCEED DESIGN LIVE PERFORMED AS RECOMMENDED, SEDIMENTAND TRASH MAY ACCUMULATE IN \ IPEPIPPIPED PIPE D \ LOADS, INCREASED TEMPORARY MINIMUM COVER REQUIREMENTS ARE FRONT OF THE OUTLET ORIFICE. MANHOLE COVERS SHOULD BE SECURELY NECESSARY. SINCE CONSTRUCTION EQUIPMENT VARIES FROM JOB TO JOB, SEATED FOLLOWING CLEANING ACTIVITIES. CONTECH SUGGESTS THAT ALL SYSTEMS BE DESIGNED WITH AN ACCESS/INSPECTION MANHOLE SITUATED AT \ \ GEOGRI IT IS BEST TO ADDRESS EQUIPMENT SPECIFIC MINIMUM COVER \ \ \ \ OR NEAR THE INLET AND THE OUTLET ORIFICE. SHOULD IT BE NECESSARY TO BEDDING UNSUTABLESOILSPLACE \ \/\ \//\ \ REQUIREMENTS WITH YOUR LOCAL CONTECH SALES ENGINEER DURING GET INSIDE THE SYSTEM TO PERFORM MAINTENANCE ACTIVITIES, ALL GRADE THE FOUNDATION SUBGRADE TO A UNIFORM OR SLIGHTLY SLOPING R. LOOSE LIFTS BEDDING YOUR PRE -CONSTRUCTION MEETING. APPROPRIATE PRECAUTIONS REGARDING CONFINED SPACE ENTRYAND OSHA GRADE. IF THE SUBGRADE IS CLAY OR RELATIVELY NON -POROUS AND THE REGULATIONS SHOULD BE FOLLOWED. CONSTRUCTION SEQUENCE WILL LAST FORAN EXTENDED PERIOD OF TIME, ANNUAL INSPECTIONS ARE BEST PRACTICE FOR ALL UNDERGROUND SYSTEMS. IT IS BEST TO SLOPE THE GRADE TO ONE END OF THE SYSTEM. THIS WILL IF AASHTO T99 PROCEDURES ARE DETERMINED INFEASIBLE BY THE DURING THIS INSPECTION, IF EVIDENCE OF SALTING/DE-ICING AGENTS IS ALLOW EXCESS WATER TO DRAIN QUICKLY, PREVENTING SATURATION OF THE GEOTECHNICAL ENGINEER OF RECORD, COMPACTION IS CONSIDERED ADDITIONAL CONSIDERATIONS OBSERVED WITHIN THE SYSTEM, IT IS BEST PRACTICE FOR THE SYSTEM TO BE SUBGRADE. ADEQUATE WHEN NO FURTHER YIELDING OF THE MATERIAL IS OBSERVED RINSED, INCLUDING ABOVE THE SPRING LINE SOON AFTER THE SPRING THAW UNDER THE COMPACTOR, OR UNDER FOOT, AND THE GEOTECHNICAL BECAUSE MOST SYSTEMS ARE CONSTRUCTED BELOW -GRADE, RAINFALL AS PART OF THE MAINTENANCE PROGRAM FOR THE SYSTEM. ENGINEER OF RECORD (OR REPRESENTATIVE THEREOF) IS SATISFIED WITH CAN RAPIDLY FILL THE EXCAVATION; POTENTIALLY CAUSING FLOATATION THE LEVEL OF COMPACTION. MAINTAINING AN UNDERGROUND DETENTION OR INFILTRATION SYSTEM IS GEOMEMBRANE BARRIER AND MOVEMENT OF THE PREVIOUSLY PLACED PIPES. TO HELP MITIGATE EASIEST WHEN THERE IS NO FLOW ENTERING THE SYSTEM. FOR THIS A SITE'S RESISTIVITY MAY CHANGE OVER TIME WHEN VARIOUS TYPES OF FOR LARGE SYSTEMS, CONVEYOR SYSTEMS, BACKHOES WITH LONG POTENTIAL PROBLEMS, IT IS BEST TO STARTTHE INSTALLATION AT THE REASON, IT IS A GOOD IDEA TO SCHEDULE THE CLEANOUT DURING DRY SALTING AGENTS ARE USED, SUCH AS ROAD SALTS FOR DEICING AGENTS. IF REACHES OR DRAGLINES WITH STONE BUCKETS MAY BE USED TO PLACE DOWNSTREAM END WITH THE OUTLETALREADY CONSTRUCTED TO ALLOW WEATHER. BACKFILL. ONCE MINIMUM COVER FOR CONSTRUCTION LOADING ACROSS A ROUTE FOR THE WATER TO ESCAPE. TEMPORARY DIVERSION MEASURES SALTING AGENTS ARE USED ON OR NEAR THE PROJECT SITE, A GEOMEMBRANE THE ENTIRE WIDTH OF THE SYSTEM IS REACHED, ADVANCE THE EQUIPMENT MAY BE REQUIRED FOR HIGH FLOWS DUE TO THE RESTRICTED NATURE OF THE FOREGOING INSPECTION AND MAINTENANCE EFFORTS HELP ENSURE BARRIER IS RECOMMENDED WITH THE SYSTEM. THE GEOMEMBRANE LINER IS TO THE END OF THE RECENTLY PLACED FILL, AND BEGIN THE SEQUENCE UNDERGROUND PIPE SYSTEMS USED FOR STORMWATER STORAGE CONTINUE INTENDED TO HELP PROTECT THE SYSTEM FROM THE POTENTIAL ADVERSE AGAIN UNTIL THE SYSTEM IS COMPLETELY BACKFILLED. THIS TYPE OF THE OUTLET PIPE. TO FUNCTION AS INTENDED BY IDENTIFYING RECOMMENDED REGULAR EFFECTS THAT MAY RESULT FROM THE USE OF SUCH AGENTS INCLUDING CONSTRUCTION SEQUENCE PROVIDES ROOM FOR STOCKPILED BACKFILL INSPECTION AND MAINTENANCE PRACTICES. INSPECTION AND MAINTENANCE DIRECTLY BEHIND THE BACKHOE, AS WELLAS THE MOVEMENT OF CATCH BASIN RELATED TO THE STRUCTURAL INTEGRITY OF THE PIPE OR THE SOUNDNESS PREMATURE CORROSION AND REDUCED ACTUAL SERVICE LIFE. CONSTRUCTION TRAFFIC. MATERIAL STOCKPILES ON TOP OF THE INLET OF PIPE JOINT CONNECTIONS IS BEYOND THE SCOPE OF THIS GUIDE. THE PROJECTS ENGINEER OF RECORD IS TO EVALUATE WHETHER SALTING BACKFILLED DETENTION SYSTEM SHOULD BE LIMITED TO 8- TO 10-FEET HIGH WATER —WATER vAvsD PARKING LOT AGENTS WILL BE USED ON OR NEAR THE PROJECT SITE, AND USE HIS/HER AND MUST PROVIDE BALANCED LOADING ACROSS ALL BARRELS. TO \\ BEST JUDGEMENT TO DETERMINE IF ANYADDITIONAL PROTECTIVE DETERMINE THE PROPER COVER OVER THE PIPES TO ALLOW THE MEASURES ARE REQUIRED. BELOW IS ATYPICAL DETAIL SHOWING THE MOVEMENT OF CONSTRUCTION EQUIPMENT SEE TABLE I, OR CONTACT YOUR PLACEMENT OF A GEOMEMBRANE BARRIER FOR PROJECTS WHERE SALTING LOCAL CONTECH SALES ENGINEER. WATER ELEVATION IN DETENTION SYSTEM AGENTS ARE USED ON OR NEAR THE PROJECT SITE. FINISHED FUNCTIONING SYSTEM ry TYPICALSACKFILLSEQUENCE TROL i iur OUTLET CON -1r ar Tr Tr' \ BAN KME Nr IMM -1 / \ remaeoo;°°� PROJECT- So. DY045199 Sierra Homes Short Plat No.: DATE: A��I/�„TCwu® 31062 45IN 318/2024 wmmWv meeue wnows` µam �1►,i\ r=r� DESIGNED: DRAWN: C�1INTECH® (N"I,aNm,""yINNIm°«.n�n.•dII�N, ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS Detention System DYO Dvo www.ContechES.com Issaquah, WA CHECKED: A➢PROVED: CONTECH DVG DYO 9025CentrePointeDr.,Suite400, West Chester, OH45069 DYODS BooJ38-„22 5,3E48-7o00 513-645-7993 FAX DRAWING DETENTION SYSTEM SHEET NO: DATE REVISION DESCRIPTION BY 1 SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Know what's beIow. Call before you dig. • CITY OF PRI RENTON • Planning/Building/Public Works Dept. A N 'CN 0— CM N �N''� O / O/�\ co N , On N N Q J I— R-428309ii J IN COMPLIANCE WITH CITY OF RENTON STANDARDS I— DEVELOPMENT ENGINEERING -. O HHuynh 09/27/2024 = cry cn LIJ 2E DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = L LI A 2 2- 0 0 0 315 FIELDBOOK: PAGE: DRAWING NO: CONSTRUCTION DETAILS III 21706 L.Lj SHEET: 9 OF: 10 V) MCM W (N 17 I N Cy) co N I C) I LLI Q I� ry- 0 Z v J LJJ G O ry- Q /LLJ V J DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY. THE APPLICANT. AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL RENTON SWDM RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10, ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 13, STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE. 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, 204.30, 204,40, AND 204,50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM 16. LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) Adn'STD. PLAN - 267.00 ,�.�• PUBLIC WORKS SURFACE WATER STANDARD PLANLWEE19W[Wby. ' DEPARTMENT NOTES (1 OF 2) lartin Pastucha8/13/2020 m,rc Pa: hm DATE B&1,a3RD88B44®D... r EncoMDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • Issaquah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 - Phone: (509) 674-7433 8:48 DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4-8INCH ROCK /40-70%PASSING; • 2-4INCH ROCK/30-40%PASS ING; AND • LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00, 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) A11011STD. PLAN - 267.10 �,,�• PNOTES (2 OF 2) artin PastuchJ PUBLIC WORKS SURFACE WATER STANDARD PLANEMUM61idby: ' DEPARTMENT/13/2020 mama, Pa hm DATE i8B8A8kF.D9S D... 0 SITE PLAN & DRAINAGE 8:48 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 WASTEWATER_ UTILITY STANDARD NOTES 1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION 2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS 3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS, INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION 4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY 5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES 7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). 8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35, C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY 9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC) UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412 10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY 11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS & SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405 12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL 13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR i S PLAN - 413 • PUBLIC WORKS WASTEWATER UTILITY A 1RR00VED �l� DEPARTMENT STANDARD NOTES Martin PastuchaLO/26/z r•eua Wan.,waaNaN.a, DATE CJA 03108124 SURVEYED: DBM NEM 08121118 DESIGNED: SS DRAWN: PS CHECKED: CA BY DATE AP P R APPROVED: CA SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Know what's beIow. Call before you dig. • CITY OF RENTON • Planning/Building/Public Works Dept. A CM N �N''� Ui ) O O 1170 , LJ N Q J R-428310 S-428303 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERINGIL Q HHuynh 09/27/2024 _ cry WASTEWATER UTILITY c� jstowell 09/27/2024 LLJ DATE: O SIERRA HOMES SHORT PLAT 06/19/2024 = L LI A 2 2- 0 0 0 315 FIELDBOOK: PAGE: DRAWING NO: CONSTRUCTION DETAILS IV 217 0 6 °Lj SHEET: 10 OF: 10 V)