HomeMy WebLinkAboutC25003173 Conditions of Approval - SatisfiedDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Conditions for Permit C25003173
Engineering
1 CROSSINGS TABLE SHALL BE REVISED AND RESUBMITTED TO THE DEVELOPMENT ENGINEERING
PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION OF SEWERMAINS
Satisfied
2 PROVIDE DECLARATION OF COVENANT (DOC) UNDER SEPARATE COVER FOR ON-SITE BMPS DRAFT
SHALL BE SUBMITTED TO DEVELOPMENT ENGINEERING PROJECT MANAGER FOR REVIEW AND
APPROVAL PRIOR TO PROJECT CLOSEOUT
Satisfied
3 ELEVATION OF WATERMAIN DOES NOT MATCH ELEVATION SHOWN ON SHEET C7.10
THE APPLICANT SHALL SEND A REVISED PROFILE OF C7.10 AND C7.11 TO THE DEVELOPMENT
ENGINEERING PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION OF
WATERMAINS
Satisfied
4 WATER METER LOCATIONS SHALL BE RELOCATED OUTSIDE OF DRIVE AISLE FOR ALL UNITS
PLANS SHALL BE REVISED AND RESUBMITTED TO THE DEVELOPMENT ENGINEERING PROJECT
MANAGER FOR REVIEW AND APPROVAL PRIOR TO WATER METER INSTALLATION
Satisfied
5 ALL GATE VALVES SHOWN IN RED SHALL BE ADDED TO PLAN VIEW
APPLICANT SHALL SEND A REVISED PLAN TO THE DEVELOPMENT ENGINEERING PROJECT MANAGER
FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION OF WATERMAINS
Satisfied
6 APPLICANT SHALL SUBMIT AN UPDATED SET OF LANDSCAPE PLANS TO THE DEVELOPMENT
ENGINEERING PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION OF THE
PROJECT LANDSCAPING AND UTILITY BOXES
Satisfied
7 APPLICANT SHALL SPECIFY ON THE PLANS IF MH #8 IS AN INSIDE OR OUTSIDE DROP
PLANS SHALL BE REVISED AND RESUBMITTED TO THE DEVELOPMENT ENGINEERING PROJECT
MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION SEWERMAINS
Satisfied
8 APPLICANT SHALL REVISE SEWER TO DRAIN TOWARDS ALLEY C AND RAISE DEPTH OF SEWER AS
HIGH AS POSSIBLE WHILE MAINTAINING 1.5-FT VERTICAL CLEARANCE MINIMUM WITH WATERMAIN
REVISED SHEET C7.15 SHALL BE SUBMITTED TO THE DEVELOPMENT ENGINEERING PROJECT
Page 1 of 2
MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION OF SEWERMAINS
Satisfied
9 APPLICANT SHALL SUBMIT A LANDSCAPE PLAN TO THE DEVELOPMENT ENGINEERING PROJECT
MANAGER FOR REVIEW AND APPROVAL SHOWING UTILITY BOX LOCATIONS (WITH LABELS) TO
ENSURE PROPER SCREENING IS PROPOSED (IE COMPLY WITH LUA CONDITION #13) PRIOR TO
CONSTRUCTION TO CONSTRUCTION OF THE PROJECT LANDSCAPING AND UTILITY BOXES
Satisfied
10 EASEMENTS SHALL BE REVISED TO CORRECT DEFICIENCIES OUTLINED BY CITY OF RENTON PER
EXHIBIT PROVIDED BY THE DEVELOPMENT ENGINEERING PROJECT MANAGER SENT TO APPLICANT VIA
EMAIL ON 12/31/2025
REVISED EASEMENTS SHALL BE PROVIDED TO THE DEVELOPMENT ENGINEERING PROJECT
MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION CLOSEOUT
Satisfied
Planning
11 IF CONDENSER SIZE, LOCATION, OR SCREENING METHOD CHANGES PRIOR TO CONSTRUCTION FOR
ANY UNITS, THE PLANNING REVIEWER SHALL BE NOTIFIED IN ORDER TO REVIEW AND APPROVE THE
CHANGES.
Satisfied
Page 2 of 2