HomeMy WebLinkAboutR-427534O O W W V Q Z L M v FOR EDGE TREATMENT OPTIONS, SEE STD. PLAN 262.20 SEE STD. PLAN TOP OF BANK 262.20 r ROADWAY OR ELEVATION PARKING LOT 2 -1 1 I11 ; 2.5 MIN., TRANSITION ZONE SOIL, //\//,"•,'�',•� - „'.�,--;; SEE STD. PLAN 262.20 �'/\\j/\� ,',iit"••yr."'c p, 2"4' DEPTH ARBORIST DESIGNER TO SPECIFY WATER STORAGE ELEVATION II 1 OVERFLOW STRUCTURE PER STD. PLAN 262.40 UNLESS SPECIFIED OTHERWISE SIDEWALK, LANDSCAPING, BOTTOM WIDTH WAY DRIVE, OR PAVEMENT MIN. 18" SIDE SLOPE AT TREE, SEE NOTE 9 2"-12" PONDING 6" MIN. FREEBOARD SEE STD. PLAN DEPTH 262,20 _ 1.5 1� I -III -III III-'. •: II IIIIII-IIIII I , WOOD CHIP MULCH,=�'•�c• -'< s_';,:; 'i '? .?':"=' ANGLE OF REPOSE SEE NOTE? `�•_ '•Y��='i.. <''��.%1'. *, BIORETENTION SOIL MIX (BSM), r� 1 12" MI SEE NOTE 5 \` UNDERDRAIN AGGREGATE, SEE NOTE 6 OVERFLOW TO STORM MAIN LOW PERMEABILITY LINER \\// SCARIFIED AND UNCOMPACTED SUBGRADE, \/\ /�\ SEE NOTES 1 AND 2 WHEN REQUIRED, SEE NOTE 3 UNDERDRAIN, SEE NOTE 4 NOTES: GRAVEL BASE, SEE STD. PLAN 262.40 1. AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2. SCARIFY SUBGRADE TO A DEPTH OF 3 INCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX AND UNDERDRAIN AGGREGATE, EXCEPT WHEN LINER IS REQUIRED. 3. LINER TO BE INSTALLED ONLY WHEN REQUIRED IN THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). LOW PERMEABILITY LINER TO BE 30 MIL MIN. GEOMEMBRANE LINER OR 12 INCHES MIN. (DRY) CLAY LINER. CLAY LINER TO BE COMPACTED TO 95% MINIMUM DRY DENSITY (ASTM D698), WITH AT LEAST 30 % CLAY PARTICLES PASSING (ASTM D422) AND AT LEAST 15 % PLASTICITY INDEX (ASTM D4318). 4. UNDERDRAIN TO BE 6" MIN. PRIVATE 8" MIN. PUBLIC SLOTTED PVC SDR 35 PER ASTM D3034. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 1/2 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT MIN. PER 100 FEET OF UNDERDRAIN AND AT EACH END. SEE STD. PLAN 226.00. MATCH CROWN ELEVATION OF UNDERDRAIN TO OVERFLOW PIPE UNLESS OTHERWISE SPECIFIED. 5. 18" MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 6. UNDERDRAIN AGGREGATE TO MEET GRAVEL BACKFILL FOR DRAINS PER WSDOT STD. SPECIFICATION SECTION 9-03.12 4 . 7. ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 8. MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6 %. 9. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.511:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2. BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 1/2" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM500 PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON -MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83% (t 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) AomSTD. PLAN - 262.10 URI� UBLIC WORKS BIORETENTION SECTION PPR DEPARTMENT (WITH UNDERDRAIN) Martin Pastucha 11/2/2 Public 609161FD98B449D... DATE CAST IRON BEEHIVE GRATE AND FRAME, SEE NOTE 1 - OPTIONAL 6" OR 8" STREAMBED COBBLES, PER WSDOT 9-03.11(2), SEE NOTE 2 _ 1)Un( SEE NOTE 3 I -III I --I I VARIES, 5' MAX.���r I T� 11' SEE NOTE 4 (TYP_) 6" MIN. - I_ STORM DRAIN PIPE, J jAA' 12" MIN. SUMP DESIGNER TO SPECIFY/�<.; o 6" MIN. - 6" MIN. CATCH BASIN ADJUSTMENT SECTION AS REQUIRED, DESIGNER TO SPECIFY ELEVATION DESIGN PONDING ELEVATION -111-11 7/H,- UNDERDRAIN PIPE, IF REQUIRED, �� SEE STD. PLAN 262.10 CATCH BASIN TYPE 1 PER STD. PLAN 200.00 OR OTHER STRUCTURE WITH APPROVAL CONCRETE BASE GRAVEL BACKFILL FOR DRAINS, COMPACT PER WSDOT STD. SPEC. 9-03.12(4) NOTES: 1. FRAME AND GRATE SHALL BE LOCKING AND GRATE SHALL BE BOLTED TO FRAME. FRAME SHALL CONFORM TO WSDOT STANDARD PLAN B-30.10-03. GRATE TO BE DUCTILE IRON BEEHIVE GRATE FITTING 20"x24" FRAME. OLYMPIC FOUNDRY PART SM60BH OR EQUAL. SEE STANDARD SPECIFICATIONS 9-05.15(2). 2. MINIMUM STREAMBED COBBLE DIAMETER SHALL BE LARGER THAN MAXIMUM GRATE OPENING. 3. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 4. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-NSEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. GENERAL NOTES: 1. PLANT SPACING WITHIN FACILITY TO ALLOW MAINTENANCE ACCESS TO STRUCTURE. 2. 12-INCH MIN. CLEARANCE WITHIN OVERFLOW STRUCTURE SHALL BE PROVIDED FOR MAINTENANCE ACCESS. 3. OVERFLOW PIPES MUST BE LOCATED AT AN ELEVATION HIGHER THAN THE STORM DRAIN HYDRAULIC GRADE LINE TO PREVENT BACKFLOW INTO THE BIORETENTION FACILITY. 4. OVERFLOW STRUCTURE SHALL BE LOCATED WITHIN 10 FEET OF ROAD EDGE FOR MAINTENANCE ACCESS, UNLESS APPROVED OTHERWISE. OVERFLOW STRUCTURE MAY BE LOCATED IN SIDE SLOPES. 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (t` STD. PLAN - 262.40 �• PUBLIC WORKS BIORETENTION -OVERFLOW OUTLET DEPARTMENT STRUCTURE Martin Pastucha 11/2 vbu®i,'Adm Q98B449D_. DATE 20 SEE NOTE 1 TOP OF BANK ELEVATION CONCRETE CURB, SEE STD. PLAN 101 6" MIN. 1" FREEBOARD ROADWAY OR 2 yl PARKING LOT Z T AA TOP OF PONDING o //I 0 TRANSITION ZONE SOIL, SEE NOTES 3 AND 4 + ff .ram" ..'- - �'• 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 7 •" z:ti ; iA_;: BIORETENTION SOIL MIX, SEE NOTE 5 BIORETENTION ADJACENT TO CURB SEE NOTE 2 SIDEWALK, LANDSCAPING, 6" MIN. 1" DRIVEWAY, OR PAVEMENT FREEBOARD 2% TOP OF PONDING - _T TRANSITION ZONE SOIL, SEE NOTES 3 AND 4 ••- +�'� 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 Sv' BIORETENTION SOIL MIX, SEE NOTE 5 BIORETENTION ADJACENT TO SIDEWALK, LANDSCAPING, DRIVEWAY OR PAVEMENT WITH FLUSH CURB OR NO CURB NOTES: ' 1. THE FOLLOWING MINIMUM SETBACKS SHALL BE PROVIDED FOR FACILITIES WITH SLOPED SIDES ADJACENT TO CURB: 1.1. 4-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO MAJOR ARTERIAL STREET. 1.2. 2-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO MINOR ARTERIAL AND COLLECTOR ARTERIAL STREET. 1.3. 1-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO NON -ARTERIAL STREET OR PARKING LOT WITH NON -FLUSH CURB. 2. THE FOLLOWING MINIMUM SETBACKS SHALL BE PROVIDED FOR FACILITIES WITH SLOPED SIDES ADJACENT TO FLUSH CURB OR NO CURB: 2.1. 2-FOOT MIN. FROM EDGE OF DRIVEWAY OR PAVEMENT TO TOP OF SLOPE ADJACENT TO DRIVEWAY OR PAVEMENT. 2.2. 1-FOOT MIN. FROM EDGE OF SIDEWALK OR LANDSCAPING TO TOP OF SLOPE ADJACENT TO SIDEWALK OR LANDSCAPING. 3. COMPACT TRANSITION ZONE SOIL IMMEDIATELY BEHIND CURB TO 90 % MAX. STANDARD PROCTOR DENSITY (ASTM D698). 4. TRANSITION ZONE SOIL SHALL BE BIORETENTION SOIL MIX OR AMENDED SOIL PER GENERAL NOTE 1. 5. 18" MINIMUM BIORETENTION SOIL MIX PER STD. PLAN 262.60 TO TOP OF PON DING DEPTH. GENERAL NOTES: 1. SOIL AMENDMENT: SCARIFY OR TILL SUBGRADE TO 3-INCH DEPTH. PLACE 3-INCHES OF TOPSOIL ON SURFACE AND TILL INTO 5-INCHES OF SITE SOIL. SCARIFICATION DOES NOT APPLY TO LINED FACILITIES. TOPSOIL SHALL HAVE A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN PLANTING BEDS AND 5 % IN TURF AREAS, AND A pH FROM 6.0 TO 8.0 OR MATCHING THE pH OF THE ORIGINAL UNDISTURBED SOIL. 2. SEE STD. PLAN 262.30 FOR CURB CUTS. 3. FOR FACILITIES WITH LINERS, PROVIDE LINER ANCHOR PER WSDOT SPECIFICATIONS 8-29.3(2). 4. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 262.20 PUBLIC WORKS RPBcRfb4€Redby: DEPARTMENT BIORETENTION -EDGE TREATMENTS 8/13/2020 artin Pastucha DATE �988POMF6998B4N9D.. PLANTING ZONES, T SEE BELOW I I I I I I O � 4) O 4) 2"4" DEPTH ARBOIRIST I I I I I WOOD CHIP MULCH, SEE STD. PLAN 262.60 BOTTOM WIDTH SIDE SLOPE AT MIN. 18" TREE, SEE NOTE 1 ROADWAY �.. A SIDEWALK OR LANDSCAPING v 2"-12" PONDING J - '* DEPTH - 1 1=1I 1=1II-1 I I1=1 I T y 1 III-1 i \ /G ! 71 T. TRANSITION ZONE SOIL,;'•'q,,., _ ''•<�,L:,, v ,.•, - SEE STD. PLAN 262.20 '')., 4 r6" MIN. t • A \/ r. BIORETENTION SOIL MIX, SEE STD. PLAN 262.60 "v/�/'IV,- /Y/�' � \- SCARIFIED AND UNCOMPACTED SUBGRADE NOTES: 1. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAYBE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6" MIN. AND INCREASE SIDE SLOPE TO 1.5HAV ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. ALL PLANTS SHALL BE SELECTED WITH A MAXIMUM MATURE HEIGHT NOT GREATER THAN 30-INCHES ABOVE THE TOP OF THE FACILITY, WITH THE EXCEPTION OF TREES AND ACCENT SHRUBS. 2. SEE STD. PLANS 262.00, 262.10, AND 262.20 FOR SECTION VIEWS OF BIORETENTION FACILITIES. 3. SEE THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) TABLE C.2.6.A FOR A SELECTION OF APPROVED WATER TOLERANT PLANTS. ADDITIONAL SPECIES ARE ALLOWED WITH CITY APPROVAL. 4. SELECT A MINIMUM OF 50% EVERGREEN PLANTS. 5. PLANTS ADJACENT TO STREET, DRIVEWAY, OR SIDEWALK SHALL BE SELECTED AND SPACED TO ALLOW ACCESS TO VEHICLES AND NOT IMPEDE PEDESTRIANS. 6. PLANTS SHALL BE SPACED TO ENSURE CLEAR ACCESS AND UNIMPEDED FLOW FROM INLETS, OUTLETS, AND OVERFLOWS. 7. CONTINUE MULCH FOR A MINIMUM OF 2-FEET PAST THE TOP OF BANK ELEVATION OR INSTALL LANDSCAPE EDGING IF FACILITY IS ADJACENT TO TURF. B. PLANTING DESIGN SHOULD MINIMIZE COMPACTION OF BIORETENTION SOIL MIX THROUGH PLANNED MAINTENANCE ACCESS. ANNUAL PLANTS REQUIRING SOIL DISTURBANCE FOR HARVESTING (E.G., CARROTS) OR ANNUAL REPLANTING ARE NOT PERMITTED. 9. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. TABLE: PLANTING ZONES ZONE PLANT TYPE LOCATION EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS O THAT CAN TOLERATE STANDING WATER) FACILITY BOTTOM PERENNIALS & LOW SHRUBS (PLANTS OEMERGENTS, `Z THAT CAN TOLERATE OCCASIONAL STANDING LOWER SLOPE TO TOP OF PONDING WATER) OGROUNDCOVERS / SHRUBS UPPER SLOPE / SIDEWALK GRADE OOO ACCENT SHRUB AAPPROPRIATE SHRUB SIDEWALK GRADE / LOWER SLOPE / FACILITY BOTTOM SED ON ZONE) OTREE UPPER SLOPE, SEE NOTE 1 UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) Aoft STD. PLAN - 262.50 PRIPUBLIC WORKS BIORETENTION PLANTING - APPR ED: DEPARTMENT SECTION VIEW GAZ 9/28/2018 Public Wort, Administrator DATE UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 MAT&H1 MATCH GUTTER CURB WIDTH WIDTH ' ) STREAMBED 6" COBBLES, 12" MIN. m a( < SEE NOTE 3 O OOOOO�oO O O O ° • • < 6" 18"-24" DESIGNER TAPER, (TYP.) • •< IT TO SPECIFY. SEE NOTE 2 . d d" • < MFLOW d -� oOfff����O�oO�O��Oo 12" y"�^ j I-) xv A d • ° dtl •• < oO �OOoO �OOO T-6" MIN. Ol d 6" MIN. TAPER UTTER AT CURB CUT TO MATCH GUTTER SLOPE UPSLOPE AND DOWNSLOPE OF CURB CUT PLAN 2" GUTTER DEPRESSION AT FLOWLINE GUTTER UPSLOPE AND TYPICAL SIDE SLOPE DOWNSLOPE OF CURB CUT 2"-4" ARBORIST WOOD CHIP SLOPE \ 2 5 MULCH, SEE STD. PLAN 262.60 ­J\ INFLOW 6" MIN. FREEBOARD \�1 ROADWAY ° \ d• a \ d • 18" a \ • 1" DROP TO COBBLES D • � 1 4" CRUSHED SURFACING ��/��/��/��/�\/��/�\/�\/� ' • I�; .,'"- 7'_,:1--� „,_J�> A`'ik,.-��,`_*•,�.f --.+U' • <_ _���., t�' �4BIORETENJION FACILITY COMPACT SOIL BELOW \ ..((gg , a <iA . ^f C y COBBLES, SEE NOT. \//�jj�jj�%j�j/\�j\ jj�-�;s",>�;��1 1�M?�G�Y ^�,� 1',-•'�','i•` 18" MIN. NOTES: SECTION A UNCOMPACTED BIORETENTION SOIL MIX (BSM), SEE STD. PLAN 262.60 1. SEE STD. PLAN 262.20 FOR EDGE TREATMENT OUTSIDE INLET AREA. 2. INLET CURB CUT WIDTH SHALL BE 24" ON GUTTER SLOPES >_ 5 % AND 18" ON GUTTER SLOPES < 5 %. 3. STREAMBED COBBLES SHALL BE 6" COBBLES PER WSDOT 9-03.11 2 . COBBLE PAD TO BE 8" THICK WITH 1:1 SIDE SLOPES TAPERING TO 12" WIDE AT FACILITY BOTTOM. 4. COMPACT BIORETENTION SOIL MIX UNDER COBBLES TO 90 % MAX STANDARD PROCTOR DENSITY (ASTM D698). GENERAL NOTES: 1. BOND NEW CURB AND GUTTER TO EXISTING CURB AND GUTTER WITH EPDXY AND DOWEL CONNECTION, IF RETROFITTING INTO EXISTING CURBLINE. REFER TO STD. PLAN 101.10 FOR EXPANSION JOINT DETAIL. 2. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) Aoft STD. PLAN - 262.30 • PUBLIC WORKS PPR D: `�1NDEPARTMENT BIORETENTION -CURB CUT INLETS GAZ 9/2s/2ols 1 Public Wortz Adm iztr DATE BIORETENTION SOIL MIX BIORETENTION SOIL MIX (BSM) SHALL BE A WELL -BLENDED HOMOGENEOUS MIXTURE OF 60 TO 65 PERCENT BY VOLUME MINERAL AGGREGATE FOR BIORETENTION SOIL AND 35 TO 40 PERCENT BY VOLUME COMPOST AS DETAILED IN THE TABLES BELOW. MINERAL AGGREGATE FOR BIORETENTION SOIL TABLE: MINERAL AGGREGATE GRADATION SIEVE SIZE PERCENT PASSING 3/8-INCH 100 PERCENT U.S. NO.4 95 TO 100 PERCENT U.S. NO. 10 75 TO 90 PERCENT U.S. NO. 40 25 TO 40 PERCENT U.S. NO. 100 4 TO 10 PERCENT U.S. NO. 200 2 TO 4 PERCENT MINERAL AGGREGATE FOR BIORETENTION SOIL MUST BE FREE OF WOOD, WASTE, COATING, OR ANY OTHER DELETERIOUS MATERIAL, AND ALL AGGREGATE PASSING THE NO. 200 SIEVE SIZE MUST BE NON -PLASTIC. MINERAL AGGREGATE MUST BE ANALYZED BY AN ACCREDITED LAB USING THE SIEVE SIZES NOTED IN THE TABLE TO THE LEFT, AND MUST MEET THE REQUIRED GRADATIONS. COMPOST TABLE: COMPOST GRADATION SIEVE SIZE MIN. PERCENT PASSING 2-INCH 10O PERCENT 1-INCH 99 PERCENT 5/8-INCH 90 PERCENT 1/4-INCH 75 PERCENT COMPOST MUST ORIGINATE A MINIMUM 65 PERCENT BY VOLUME FROM RECYCLED PLANT WASTE COMPRISED OF YARD DEBRIS, CROP RESIDUES, AND BULKING AGENTS, AND MEET THE DEFINITION OF "COMPOSTED MATERIAL" IN WAC 173-350-100. COMPOST SHALL HAVE A MOISTURE CONTENT THAT HAS NO VISIBLE FREE WATER OR DUST PRODUCED WHEN HANDLING THE MATERIAL. COMPOST SHALL HAVE AN ORGANIC MATTER CONTENT OF 40 PERCENT TO 65 PERCENT BY DRY WEIGHT, A CARBON TO NITROGEN RATIO BELOW 25:1, AND A pH BETWEEN 6.0 AND 8.0 ABORIST WOOD CHIP MULCH TABLE: ARBORIST WOOD CHIP MULCH GRADATION SIEVE SIZE PERCENT PASSING 6-INCH 10O PERCENT 2-INCH 95 TO 100 PERCENT 1-INCH 70 TO 100 PERCENT 5/8-INCH 0 TO 50 PERCENT U.S. NO.4 0 TO 30 PERCENT ARBORIST WOOD CHIP MULCH SHALL BE COARSE GROUND WOOD CHIPS (APPROXIMATELY 1/2" TO 6" ALONG THE LONGEST DIMENSION) DERIVED FROM THE MECHANICAL GRINDING OR SHREDDING OF THE ABOVE -GROUND PORTIONS OF TREES. IT MAY CONTAIN WOOD, WOOD FIBER, BARK, BRANCHES, AND LEAVES, BUT MAY NOT CONTAIN WEEDS, WEED SEEDS, OR VISIBLE AMOUNTS OF SOIL. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 262.60 V'R] PUBLIC WORKS BIORETENTION SOIL MIX, COMPOST ISRN4dby: DEPARTMENT AND MULCH SPECIFICATIONS lartin Pastucha 8/13/20 ( 8B81B1FD�98B449D.__ DATE 1 1ST SUBMITTAL CORRECTIONS DJL 9 23 25 SURVEYED: SCALE: BY OTHERS VERTICAL NAVD 1988 83/1 2 2ND SUBMITTAL CORRECTIONS DJL 4 20 26 HORIZONTAL NAD 193/1991 DESIGNED: 3 95% CD'S DJL 5/15/26 DAN/EL ✓. LARSON, P.E. 4 3RD SUBMITTAL CORRECTIONS DJL 5/26/26 DRAWN:CHUCK FENCING ONE INCH DATUM CHECKED: AT FULL SCALE KA I L LANE, L T. SCALE NOT ONE INCH ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: DAN/EL ✓. LARSON, P.E. 24" L 2 1/2" DIA. HOLE 20" A 4�4dG� O�O�O�O�O TOP m ISOMETRIC I � I 1/2" I BOLT -DOWN SLOT, 3I4" SEE DETAIL AND NOTE 1 1 11/4" 5/8" I I I 1 BOLT -DOWN SLOT DETAIL SEE NOTE 1 �3.,1 r4 3/4" 1 1/2" 1 5/8l R39", SEE NOTE 2 SECTION A SECTION B R26", SEE NOTE 2 '2" 5„ NOTES: 3 1/2" r 3/4" i 518" 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN 4" I HEAD CAP SCREW BY BEING TAPPED, OR OTHER II _ 3/4" DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 1 /2" DIA. HANDLE 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. SECTION C 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.10 URI •PUBLIC WORKS DEPARTMENT RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 1 NMI,, Worts Ad---, DATE % CITY OF RENTON Planning/Building/Public Works Dept. O O O O I N N J Lq ?�•oF•WAsyyso CIVIL ENGINEERING �• P `' �� LANDSCAPE ARCHITECTURE PLANNING o�;o•,pF�o�as2�s�o•.�� DESIGN SURVEYING Fss/ONAL ENG\ 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 5/26/26 R-4 2 7 53 4 IN COMPLIANCE WITH CITY OF RENTON STANDARDS \ DEVELOPMENT ENGINEERING Q yqi 06/09/2026 1u�1 1� LAJ V !(ENNYDALE GA TEWA Y DATE 5115126 Q 1310, 1321 & 1331 NE 43RD ST, RENTON, WA 98056 FIELDBOOK: O PAGE DRAWING NO: C4.35 Z STORM DRAINAGE DETAILS SHEET: 34 OF: 48