HomeMy WebLinkAboutR-427535O O W W V Q Z Unit ID: North BioPod 1 BPU-10241B-PV WADOE GULD WQ Flow Rate 0.658 cfs WQ Flow Rate (100-Yr) 3.3 cfs Max Peak Flow 20 cfs 2.00" MULCH. 18.00" StormMix- MEDIA 6.00" DRAIN ROCK.r��"ry 3X 04.00" SLOTTED PVC UNDERDRAIN PIPE. CCr`TIlIAI Q Q INTERIOR/EXTERIOR JOINT SEALANT REQUIRED, (CONSEAL CS-231 OR EQUIVALENT), BY OTHERS. 12'-6" 11'-6" 101-0" PIPE ANGLES IMMEDIATELY OUTSIDE • STRUCTURE, BY OTHERS. 2X 036" ACCESS COVERS. FIELD GROUT AS NEEDED TO MEET GRADE, BY OTHERS. TOS: 33.05' - RIM: RIM: 2" SLOT L 33.46'-34.24' , 33.46'-34.24' TYPICAL BAFFLE WALL, - -- EL: 30.88'. IE: 28.75' INLET, 016" OPENING FOR 012" SD. ACCESS CAP FOR OPTIONAL DRAIN -DOWN DEVICE 2X 6"x24" INLET WINDOW, IE: 29.05'. SECTION D-D 26'-6" SLAB OD 25'-6" WALL OD -24'4' WALL ID- 9" TYPICAL LL THICKNESS - 2X ACCESS CAP FOR OPTIONAL DRAIN -DOWN DEVICE ,. Iy t 6X 04" SLOTTED PVC UNDERDRAIN PIPE. L—D OUTLETI }� COBBLES FOR ENERGY DISSIPATION , 0J16" OPENING 2X 6"x24" INLET WINDOW IE: 29.05'. FOR 012" ' SD IE: 2 . 6 88 BYPASS WEIR, EL: 29.71'. PIPE ANGLE, BY OTHERS. • 10'-0.1 6-6" 101-01, TOP SLAB #1 TOP SLAB #2 TOP SLAB #1 29.71' VARIES 2.83' [34.00"] IE: 26.88' 2" --- cc 0OPENING.- 111111 •�� 1 907,V BAFFLE WALL, EL: 30.88'. 2X 6"x24" INLET WINDOW, IE: 29.05. 77 2X 024" ACCESS COVERS. FIELD GROUT AS NEEDED TO MEET GRADE, BY OTHERS. VARIES ADJUST TO GRADE RIM: 33.46'-34.24' 1'-0" TOP EL- 1 5'- :h;, 10" B OUTLET, 016" OPENING I INLET, 016" OPENING I 6X 04" SLOTTED PVC FOR 012" SD. INTERIOR/EXTERIOR JOINT FOR 012" SD, FARSIDE. UNDERDRAIN PIPE. 06" PVC OUTLET ORIFICE SEALANT REQUIRED, BYPASS WEIR, EL: 29.71'. I COBBLES FOR ENERGY DISSIPATION CAP INTO OUTLET CHAMBER. (CONSEAL CS-231 OR TREATED OUTLET ORIFICE OUTLET, 016" OPENING EQUIVALENT), BY OTHERS. CAP INTO OUTLET CHAMBER. FOR 012" SD, NEARSIDE. 9'-0" 8'-6" 9'-0" BOTTOM SLAB #1 BOTTOM SLAB #2 BOTTOM SLAB #1 SECTION A -A �� mJ BiOre[enfiON 340fil1ra1i0n NOTES: 1. DESIGN LOADINGS: A. AASHTO HS-20-04 W/IMPACT. B. DESIGN FILL: 1' MAXIMUM. C. ASSUMED WATER TABLE =S'BELOW GRADE. D. DRY LATERAL EARTH PRESSURE (EFP) = 45 PCF. E. LATERAL LIVE LOAD SURCHARGE =80 PSF (APPLIED TO 8' BELOW GRADE). F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 26 DAY COMPRESSIVE STRENGTH SHALL BE 5,000 PSI MINIMUM. 3, STEEL REINFORCEMENT: REBAR, ASTM A-8150R A-708, GRADE 60. 4. MESH REINFORCEMENT: ASTM A-1064, 57.2, GRADE 80. 6_ CEMENT: ASTM C-150 SPECIFICATION_ 8. REFERENCE STANDARD: A. ASTM C 890 B. ASTM C 913 7, THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. PLEASE VERIFY THAT THESE PARAMETERS MEET PROJECT REQUIREMENTS (I.E. LIVE LOAD, FILL RANGE, WATER TABLE). IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEER/AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW OF THIS SUBMITTAL. 8. OVERSIZED HOLES TO ACCOMMODATE SPECIFIC PIPE TYPE MUST BE CONCENTRIC TO PIPE ID. AFTER PIPES ARE INSTALLED, ALL ANNULAR SPACES SHALL BE FILLED WITH A MINIMUM OF 3000 PSI CONCRETE FOR FULL THICKNESS OF PRECAST WALLS. PIPES ARE TO BE FLUSH WITH THE INSIDE SURFACE OF THE CONCRETE STRUCTURE. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. MEDIA, DRAIN ROCK, MULCH, AND INTERNAL COMPONENTS SHIPPED SEPARATELY. INSTALLER RESPONSIBLE FOR PLACEMENT OF THESE MATERIALS IN THE STRUCTURE. 12. OLDCASTLE REPRESENTATIVE TO BE ON SITE TO OVERSEE INSTALLATION. 13. CONTRACTOR TO ENSURE UNIT IS PROTECTED FROM CONSTRUCTION DEBRIS/RUNOFF AFTER INSTALLATION. 14. CONTRACTOR RESPONSIBLE FOR SUPPLYING CRANE TO OFF-LOAD AND SET PANELS; SUPPLY PERSONNEL AND TOOLS NEEDED FOR INSTALLATION; INSTALL GASKET AT TOP, BOTTOM AND BETWEEN ALL WALLS; GROUT ALL SEAMS 8 WALL CONNECTIONS PRIOR TO BACKFILLING (GROUT TO BE NON -SHRINK, 5000 PSI MINIMUM BEFORE BACKFILLING). 15. SECTION HEIGHTS, SLAB/WALL THICKNESSES AND KEYWAYS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY AND PRODUCTION PLANT CAPABILITY. 18. ADAPTORS/ANGLES AND EXTERNAL PIPING BY OTHERS. 17. MAXIMUM PICK WEIGHT: TOP SLAB #1 = 17,000 CBS. - PRELIMINARY - NOT FOR CONSTRUCTION AMCOMOF OLDCASTLE INFRASTRUCTURE, INC. THE SION OF I CRANE HOOK SPREADER BAR 00 00000 00000 00 CABLE (8) PLACES ROLLING BLOCK CRANE HOOK (4) PLACES CABLE (4) PLACES 4-TON'BURKE RING CLUTCH 'BURKE' LIFT ANCHOR 4-TON'BURKE' RING CLUTCH 'BURKE LIFT ANCHOR PRECAST PANEL PRECAST PANEL ANGLE SLING ANGLE SLING DUNNAGE DUNNAGE (2) PLACES (2) PLACES 8-POINT FLAT PICK DETAIL 4-POINT FLAT PICK DETAIL SLING ANGLE MUST BE AT LEAST 60° SLING ANGLE MUST BE AT LEAST 60° CRANE HOOK CABLE (4) PLACES CRANE HOOK ROLLING BLOCK (2)PLACES CABLE (2) PLACES 4-TON'BURKE' RING CLUTCH 4-TON'BURKE' RING CLUTCH 'BURKE' LIFT ANCHOR S(//yGgNGtf 'BURKE'LIFT ANCHOR SUNGq,VGL f PRECAST PANEL PRECAST PANEL DUNNAGE 0.OldcaStle Infrastructure' (2)PLACES DUNNAGE (2) PLACES UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/g GASKET (2 ROWS) (AT EDGES OF END WALLS) GASKET (2 ROWS) (IN END WALL KEYWAY) WRAP GASKET ONTO BASE 6' GASKET (2 ROWS) (IN BASE KEYWAY) GASKET SHOULD BE CONTINUOUS AROUND CORNERS r BUTT JOINT AT SPLICE (DO NOT OVERLAP) GASKET INSTALLATION DETAIL F/_`IgANdG1q1 FILL RECESS WITH GROUT TOP /BASE SEAM DETAIL GASKET (2 ROWS) (AT EDGES OF SIDE WALLS) 0 E 0 WALL CONNECTION POCKET GALVANIZED CHANNEL WASHER 1"0 FLAT WASHER (2" O.D.) (WAY DETAIL 1"0 x 3Y�" COIL BOLT WALL CONNECTION DETAIL BOLT CONNECTIONS ARE USED TO COMPRESS CONSEAL GASKET AND HOLD WALLS DURING ASSEMBLY; BOLT CONNECTIONS ARE NOT STRUCTURAL SEAM GROUT DETAIL Ilk 1 1ST SUBMITTAL CORRECTIONS DJL 9/23/25 SURVEYED: BY OTHERS SCALE: 2 2ND SUBMITTAL CORRECTIONS DJL 4 20 26 DESIGNED: DAN/EL ✓. CARBON, P.E. 3 95% CD'S DJL 5/15/26 4 3RD SUBMITTAL CORRECTIONS DJL 5/26/26 DRAWN: CHUCK FEML/NG ONE INCH CHECKED: KATIE LANE, E.l. T. AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE AP P R ^PPft°VE°: DAN/EL ✓. CARBON, P.E. DUT ALL JLT SEAMS VAULT WALL ALL SEAMS A CONSEAL GASKET 2 ROWS PLACE IN 3' x %" RECESSES VAULT WALL PLACE WALL IN CENTER OF KEYWAY 3' x %" RECESSES J k °' 10" KEYWAY DETAIL CONSEAL GASKET LOCATIONS VAULT WALL LOCATION GENERAL NOTES 1. CUSTOMER T0: VERIFY ALL VAULT FEATURES VAULT BASE SUPPLY CRANE TO OFF-LOAD AND SET PANELS SUPPLY PERSONNEL AND TOOLS NEEDED FOR INSTALLATION INSTALL GASKET AT TOP, BOTTOM AND BETWEEN ALL WALLS GROUT ALL SEAMS &WALL CONNECTIONS PRIOR TO BACKFILLING (GROUT TO 8E NON -SHRINK, 5,000psi MINIMUM BEFORE BACKFILLING) SUPPLY, INSTALL &GROUT -IN ALL PIPING &SAMPLING TEES 2. OLDCASTLE PRECAST TO: PROVIDE PRECAST PANELS PROVIDE CONSEAL GASKET &WALL CONNECTION HARDWARE 3. TOP SECTION NOT REMOVABLE AFTER VAULT IS BACKFILLED old O N N v O O O N LAJ VERTIipNA1988 .R i •oF WAsyyso CIVIL ENGINEERING • �' `' �� LANDSCAPE ARCHITECTURE PLANNING -o'• 21018929 DESIGN SURVEYING TONAL 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 512rol2ro R-4 2 7 53 5 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING � I Q yq 06i09i2026 '.� � _ DATE: V HORI ONTAL• NADw 983/1991 CITY 0 F `(E/V/V YDAL E GA TEWA Y 5/>5/26 Q 1310, 1321 & 1331 NE 43RD ST, RENTON, WA 980515 FlELDBOOK: RENTON PAGE: DATUM DRAWING N0: Planning/Building/Public Works Dept. C4 36 STORM DRA/IVAGE DETA/LS SHEET: 35 OF, 48 ,