UNIT ID: SOUTH BioPod 2
BPU-12241B-PV
WQ Flow Rate
0.74 cfs
Max Peak Flow
17.3 cfs
PIPE ANGLES IMMEDIATLY OUTSIDE
• OF THE STRUCTURE, BY OTHERS. M
14'-6" 'I T-6" 12'-0"
FOOTING WALL OD WALL ID
2" MULCH.
71
.sYYrs�
18" StormMixT" MEDIA
r
12" DRAIN ROCK.
3X 06" SLOTTED PVC
UNDERDRAIN PIPE.
SECTION B-B
INTERIOR
BAFFLE WALL,
EL: 31.87'
BYPASS WEIR,
EL:30.20'`
018" DOGHOUSE `
OPENINGIN BAFFLE i
WALL.
2X DRAIN DOWN DEVICE, J
SK-0962
INLET, 016" OPENING
FOR 012" SD, NEARSIDE.
OUTLET, 016" OPENING J I--4'4'----� I--6" L 5X 6"x24" INLET
A
FOR 012" SD, IE: 26.87' 018" DOGHOUSE OPENING WINDOW, IE: 29.54' IN BAFFLE WALL. D
13'-3" 13'-3"
TOP SLAB #1 TOP SLAB #2
PLAN VIEW
2X 024" TRAFFIC RATED CAST IRON COVERS. TOP SLAB NOT SHOWN IN THIS VIEW.
FIELD GROUT AS NEEDED TO MEET GRADE,
BY OTHERS.
2X 036" ACCESS COVERS.
FIELD GROUT AS NEEDED TO MEET GRADE,
BY OTHERS. VARIES
RIM: 33.70'-34.76' ADJUST TO GRADE
RIM: 33.70'-34.76'r
V-0" TOP
55" T-3"
10" BASE
I
1
�I
L 10"x98" OPENING FOR
3X 06" UNDERDRAIN.
5X COBBLES FOR
ENERGY DISSIPATION.
5X 6"x24" INLET WINDOW,
I E: 29.54'
SECTION D-D
(OUTLET PIPE NOT SHOWN FOR CLARITY)
BYPASS WEIR
3-
EL: 30.20'
ES VARIES
3.33'
[40.00"]
t�
IE: 26.87'
EL: 26.04' OUTLET, 016" OPENING
FOR 012" SD.
2X DRAIN DOWN DEVICE,
SK-0962
INTERIOR WALL,
EL: 31.87', 10"x98" OPENING FOR 3X 06"
UNDERDRAIN, IE: 26.87'.
INTERIOR/EXTERIOR JOINT SEALANT REQUIRED,
(CONSEAL CS-231 OR EQUIVALENT),
BY THE CONTRACTOR.
SECTION A -A
(MEDIA NOT SHOWN FOR CLARITY)
INTERIOR
BAFFLE WALL,
EL: 31.87'
NOTES:
1. DESIGN LOADINGS:
A. AASHTO HS-20-44 (WITH IMPACT)
B. DESIGN SOIL COVER: 5'-O" MAXIMUM
C. ASSUMED WATER TABLE: BELOW BASE OF PRECAST
(ENGINEER -OF -RECORD TO CONFIRM SITE WATER
TABLE ELEVATION)
D. LATERAL EARTH PRESSURE: 60 PCF (DRAINED)
E. LATERAL LIVE LOAD SURCHARGE: 80 PSF (APPLIED
TO 8'-0" BELOW GRADE)
F. NO LATERAL SURCHARGE FROM ADJACENT
BUILDINGS, WALLS, PIERS, OR FOUNDATIONS.
2. CONCRETE 28-DAY MINIMUM COMPRESSIVE
STRENGTH: 5,000 PSI MINIMUM.
3. REINFORCING: REBAR, ASTM A6151A706, GRADE 60
4. MESH REINFORCEMENT: ASTM A1064, S12, GRADE 80
5. CEMENT: ASTM C150
6. REQUIRED ALLOWABLE SOIL BEARING CAPACITY:
2,500 PSF
7. REFERENCE STANDARD:
INTERIOR
A. ASTM C890
BAFFLE WALL,
B. ASTM C913
EL: 31.87'
C. ACI 318-14
8. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS
5X COBBLES
NOTED HEREIN. ENGINEER -OF -RECORD SHALL VERIFY
FOR ENERGY
THAT NOTED PARAMETERS MEET OR EXCEED PROJECT
DISSIPATION.
REQUIREMENTS. IF DESIGN PARAMETERS ARE
INCORRECT, REVIEWING ENGINEERIAUTHORITY SHALL
NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW.
PIPE ANGLE,
`BY OTHERS.
9. OVERSIZED HOLES TO ACCOMMODATE SPECIFIC PIPE
TYPE MUST BE CONCENTRIC TO PIPE ID. AFTER PIPES
ARE INSTALLED, ALL ANNULAR SPACES SHALL BE FILLED
WITH A MINIMUM OF 3,000 PSI CONCRETE FOR FULL
THICKNESS OF PRECAST WALLS.
1
A
2X 1'-2"
10. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES,
LOCATIONS, AND ELEVATIONS OF OPENINGS.
2.95°
11. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE
BEARING SURFACE IS PROVIDED ILE. COMPACTED AND
INLET, 016" OPENING
LEVEL PER PROJECT SPECIFICATIONS).
FOR 012" SD, IE: 28.30'
12. ADAPTORS/ANGLES AND EXTERNAL PIPING BY OTHERS.
13. SECTION HEIGHTS, THICKNESSES, AND
KEYWAYS ARE SUBJECTECT TO CHANGE AS REQUIRED FOR
SITE REQUIREMENTS AND/OR DUE TO PRODUCT
•
AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS.
14. MAXIMUM PICK WEIGHTS: TOP SLAB #1 = 27,900 LBS
15. INTERNALS SHALL CONSIST OF UNDERDRAIN PIPE,
ROCK, STORMMIX'"' MEDIA, MULCH, DIVIDER WALLS,
BAFFLE WALLS, BYPASS WEIR AND OPTIONAL DRAIN
DOWN.
16. SYSTEM SHIPPED EMPTY. INTERNALS INSTALLED BY
CONTRACTOR.
17. CONTRACTOR RESPONSIBLE FOR OFF-LOAD AND
INSTALLATION. OLDCASTLE REPRESENTATIVE TO BE ON
SITE TO OVERSEE THE INSTALLATION OF ALL INTERNAL
COMPONENTS.
T RIM: 33.70'-34.76'
18. CUSTOMER TO INSTALL GASKET AT TOP, BOTTOM AND
BETWEEN ALL WALLS, AND GROUT ALL SEAMS & WALL
1
CONNECTIONS PRIOR TO BACKFILLING (GROUT TO BE
NON -SHRINK, 5,000 PSI MINIMUM BEFORE BACKFILLING).
F�
IE:28.30'
INLET, 016" OPENING
FOR 012" SD.
5X 6"x24" INLET WINDOW,
IE: 29.54'
f�� 1
Bioretention/
Blofiltralion
- PRELIMINARY -
NOT FOR CONSTRUCTION
CRANE HOOK SPREADER BAR
00 00000 00000 00
CABLE
(8) PLACES
ROLLING BLOCK CRANE HOOK
(4) PLACES
CABLE
(4) PLACES
4-TON'BURKE' RING CLUTCH
'BURKE' LIFT ANCHORZL 4-TON'BURKE' RING CLUTCH
'BURKE' LIFT ANCHOR
PRECAST PANEL
PRECAST PANEL
SLING ANGLE
SLING ANGLE
DUNNAGE
DUNNAGE
(2)PLACES
8-POINT FLAT PICK DETAIL (2)PLACES 4-POINT FLAT PICK DETAIL
SLING ANGLE MUST BE AT LEAST 60' SLING ANGLE MUST BE AT LEAST 60'
CRANEHOOK
CABLE
(4) PLACES
CRANE HOOK
ROLLING BLOCK
(2)PLACES CABLE
(2) PLACES
4-TON'BURKE' RING CLUTCH 4-TON'BURKE' RING CLUTCH
'BURKE' LIFT ANCHOR
SLINGANGtE 'BURKE' LIFT ANCHOR SING,%GLE
PRECAST PANEL
PRECAST PANEL
DUNNAGE (2)PLACES DUNNAGE Olcicastle Infrastructure
0
(2) PLACES AawcoLwwv
Ph: 800.879.8819 wws.olCwslklnhasWCNre st AaWr
F OLDCASTLE INFRASTRUCTURE, INC.
SHALLNOTIT IS NOTMBENUSEDHINU ANYTTED FOR WAYY INJURIOUS TOCTHEURPOSES OLY ND
INTERESTS OF, A0 R
FA0R
WITHOUNFRA TRUCTURE, INC.
COPYR GTHT C iB 2THE I OLDCASTLE GCAST EEN I SNFRASTR CTURSION OF E IN C.TLE I ALL RIGHTS RESERVED.
BioPodTm Biofilter Underground
o\� 10'x24' Panel Vault with Internal Bypass
4-POINT EDGE PICK DETAIL 2-POINT EDGE PICK DETAIL CUSTOMER
SLING ANGLE MUST BE AT LEAST 60' SLING ANGLE MUST BE AT LEAST 60' Core Design Inc.
PROJECT NAME
Kennydale Gateway - Renton, WA
DATE MFG DRAWN ENGINEER CHECKED SALES ORDER
.W22 010-AU PPS AFD ARID
REVISION SHEET
LIFT DETAILS REVDATE 3 OF 3
REV DESCRIPTION I BY I DATE
UNDERGROUND LOCATOR SERVICE
CALL BEFORE YOU DIG!
811
GASKET (2 ROWS)
(AT EDGES OF END WALLS)
GASKET (2 ROWS)
(IN END WALL KEYWAY)
WRAP GASKET
ONTO BASE 6"
GASKET (2 ROWS)
(IN BASE KEYWAY)
GASKET SHOULD BE
CONTINUOUS AROUND CORNERS
r BUTT JOINT AT SPLICE
/ (DO NOT OVERLAP)
GASKET INSTALLATION DETAIL
VAULT WALL
FILL RECESS
WITH GROUT
a �
a'
TOP / BASE SEAM DETAIL
GASKET (2 ROWS)
(AT EDGES OF SIDE WALLS)
1
1ST SUBMITTAL CORRECTIONS
DJL
9/23/25
SURVEYED:
OTHERS
SCALE:
2
2ND SUBMITTAL CORRECTIONS
DJL
4 20 26
DESIGNED:
DE
DAN/EL ✓. LARSON, P.E.
3
95% CD'S
DJL
5/15/26
4
3RD SUBMITTAL CORRECTIONS
DJL
5/26/26
DRAWN:
CHUCK FEML/NG
ONE INCH
CHECKED.
KATIE LANE, E.l. T"
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NO.
REVISION
BY
DATE
AP P R
APPROVED:
DANY ✓" LARSON, P.E.
WALL CONNECTION POCKET J
GALVANIZED CHANNEL WASHER
1.0 FLAT WASHER (2' O.D.)
MAY DETAIL 1 "O x 3Y" COIL BOLT
WALL CONNECTION DETAIL
BOLT CONNECTIONS ARE USED TO COMPRESS CONSEAL GASKET
AND HOLD WALLS DURING ASSEMBLY;
BOLT CONNECTIONS ARE NOT STRUCTURAL
SEAM GROUT DETAIL
OUT ALL
ULT SEAMS
VAULTWALL
VAULT WALL
CONSEAL GASKET
2 ROWS
PLACE IN 3" x %B RECESSES PLACE WALL IN
CENTER OF KEYWAY
GENERAL NOTES
1. CUSTOMER TO:
VERIFY ALL VAULT FEATURES
VAULTBASE SUPPLY CRANE TO OFF-LOAD AND SET PANELS
ALL SUPPLY PERSONNEL AND TOOLS NEEDED FOR INSTALLATION
SEAMS INSTALL GASKET AT TOP, BOTTOM AND BETWEEN ALL WALLS
' RECESSES 10" GROUT ALL SEAMS & WALL CONNECTIONS PRIOR TO BACKFILLING
3" x
(GROUT TO BE NON -SHRINK, 5,000psi MINIMUM BEFORE BACKFILLING)
.�On KEYWAY DETAIL SUPPLY , INSTALL &GROUT -IN ALL PIPING & SAMPLING TEES
2. OLDCASTLE PRECAST TO:
CONSEAL GASKET LOCATIONS PROVIDE PRECAST PANELS
VAULT WALL LOCATION PROVIDE CONSEAL GASKET & WALL CONNECTION HARDWARE
3. TOP SECTION NOT REMOVABLE AFTER VAULT IS BACKFILLED
O
O
O
N
N
Ilk
j 111_0�
?�•oF'wq'sy�yso CIVIL ENGINEERING
�• P `' �� LANDSCAPE ARCHITECTURE
PLANNING
'Con
-o'• P, 21018929 '� DESIGN SURVEYING
Fss/ONAL ENG\ 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
5126l26 R-4 2 7 53 6
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING Q
yqi 06/09/2026 I�I,''
�V1-7
VERTICAL- DATE: V
HORI ONTAL- N D 1983/1991 CITY O F `(ENNYDAL E GATEWAY 5115126 Q
1310, 1321 & 1331 NE 43RD ST, RENTON, WA 98056 FlELDBOOK:
RENTON PAGE:
DATUM 14111111111111W DRAWING NO:
Planning/Building/Public Works Dept. Cdo 37 W
STORM DRAINAGE DETAILS SHE: 36 OF: 48