Loading...
HomeMy WebLinkAboutW-4275091 \ N k W W V Q Z M v WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BYTHE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. 10. RECYCLED CONCRETE AGGREGATE SHALL NOT BE USED AS BEDDING OR BACKFILL MATERIALS FOR WATER MAINS AND WATER SERVICES ti�Y o STD. PLAN - 300.0 Gn * PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2O10 PLAN a F-------------- ------ - - - - - - - - - - - - - I 6r� I S MIN V C I I I ° 6" E A B D 6" I �IMIN I MIN �I �0 � 0 P��� f I I I I I PIPE SLEEVE a I 12" C 1 K L M N MIN SEE DETAIL, THIS SHEET a L______________-i_________________ ^ a ° d ° F SEE DETAIL MIN PUBLIC WORKS DEPARTMENT 6" PIPE SLEEVE PVC PIPE SLEEVE EPDXY SEALANT EPIPE > EPDM MODULAR SEAL, LINK -SEAL MODEL C WITH 316SS BOLTS AND NUTS 3", 4", AND 6" WATER METER STD. PLAN - 320.4 Sht. 1 of 2 ROVED: 6/28/2023 "wo.'"<n• DATE x: ^emmavror EXISTING WATER MAIN 0 PUBLIC WORKS DEPARTMENT TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING NEW DI WATER MAIN TEMPORARY BLOCKING CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (MJxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (M.) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (2) GATE VALVES (FLxMJ) (1) ADAPTER (FLxMJ) (1) PLUG (M.) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION UPON COMPLETION OF POLYPIGGING HYDROSTATIC TESTING AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3. COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE STD. PLAN - 300.2 CONNECTION TO WATER MAIN CUT -IN TEE AND TWO VALVES NOTES: 1. VAULTS SHOULD NOT BE INSTALLED IN AREAS WITH VEHICLE TRAFFIC. 2. ALL INTERIOR METAL INCLUDING PIPE, VALVES, AND FITTINGS TO BE PAINTED WITH TWO COATS OF EPDXY AS APPROVED BY THE ENGINEER. USE TNEMEC SERIES 135 CHEMBUILD MODIFIED POLYAMIDE EPDXY. APPLY PER MANUFACTURERS INSTRUCTIONS. 3. VAULT AND HATCH MODELS ARE PROVIDED AS REFERENCE. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CITY FOR APPROVAL. 4. FOR 3" AND 4" METERS, USE 2" BYPASS MATERIALS, AND FOR 6" METERS, USE 3" BYPASS MATERIALS, AS INDICATED BELOW. 5. INSTALL WATER METER RADIO & BATTERY UNITS IN ACCESS HATCH PANELS WITH MINIMUM 6" SEPARATION. DATE U METER AMI WATER METER (SENSUS OMNI WITH INTERNAL STRAINER) WITH RADIO AND BATTERY UNIT 2" BRASS NIPPLE (MIPTxMIPT), 6" LONG, CONNECTED TO TEST PORT OF COMPOUND METER 1" BALLCORP (MIPTxFIPT), FORD FB1700-4-NL OR EQUAL, FOR 3" METER O METER TEST PORT OR 1 Y2" BALLCORP (MIPTxFIPT), FORD FB1700-6-NL OR EQUAL, FOR 4" AND 6" METERS 2"X212" ADAPTER (MIPTxMNST) 21/2" CAP (FNST) C ADAPTER FLANGED COUPLING ADAPTER, MEGAFLANGE SERIES 2100, OR EQUAL O PIPE CLASS 53 DI PIPE (PExFL) O VALVE (2) GATE VALVE (FLxFL) WITH HANDWHEEL OPIPE SUPPORT ADJUSTABLE PIPE SADDLE SUPPORT, GRINNELL FIG 264 OR EQUAL, WITH BASE, BOLTED TO FLOOR O SERVICE SADDLE (2) 2" NPT SADDLE, SMITH-BLAIR MODEL 313 OR EQUAL OR (2) 6"X3" TEE (MJxFL) OBYPASS VALVE (2) 2" BRASS GATE VALVE (IPT) OR (2) 3" GATE VALVE (FLxFL) WITH 3" THREADED (IPT) FLANGE OI BEND (2) 2" 90- BEND OR (2) 3" 90° BEND JO BYPASS PIPE 2" GALVANIZED PIPE, EPDXY COATED, OR 3" GALVANIZED PIPE, EPDXY COATED 2" STRAIGHT FLANGE BALL VALVE (FLxFIPT) WITH PADLOCK WINGS, FORD BF31-777W-NL OR EQUAL OK BYPASS METER VALVE OR 3"x2" REDUCER WITH 2" BRASS NIPPLE CL) BYPASS METER 2" AMI BYPASS METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY C) METER FLANGE 2" METER FLANGE (FLxFIPT), FORD CF31-77-NL OR EQUAL, OR 3"x2" REDUCER WITH 2" BRASS NIPPLE CN) UNION 2" TWO-PART UNION OR 3" TWO-PART UNION TEE 2" TEE OR 3" TEE (PJ) BUSHING TN3/4" BUSHING OR 3"0/4" BUSHING WITH 3/4" PLUG CQj WATER MAIN CLASS 52 DI PIPE WITH RESTRAINED JOINTS OR WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 350.7 CONCRETE VAULT OLDCASTLE PRECAST VAULT, MODEL NUMBERS PER TABLE BELOW, OR EQUAL MINIMUM 4" PVC FLOOR DRAIN, SLOPE TO STORM DRAIN OR DAYLIGHTTO DRAINAGE DITCH WITH WIRE OT DRAIN MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC -RATED, WITH SLIP -RESISTANT TREATMENT, MARKED CU 11 ACCESS HATCH "WATER", LW PRODUCTS MODEL NUMBERS PER TABLE BELOW, OR EQUAL. C) LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 350.8 (W) GRAVEL FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS VAULT MODEL NUMBERS METER SIZE VAULT BASE PIECE CENTER PIECE TOP PIECE ACCESS HATCH 3" 676-WA NO.676-BL NO. 676-MLW NO. 676-TL-2-332P HHD-1C 4" 676-WA NO.676-BL NO. 676-MLW NO. 676-TL-2-332P HHD-1C 6" 4484-LA NO.4484-BL NO.4484-ML NO.4484-TL-2-332P HHD-2D 0 0PUBLIC WORKS DEPARTMENT UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 3", 4", AND 6" WATER METER STD. PLAN - 320.4 Sht. 2 of 2 DATE 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. MATERIALS COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 %4" MVO, OA HYDRANT 1 V4" PENTAGON OPERATING NUT, TWO (2) 2 %" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. OB TEE MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET OC VALVE 6" GATE VALVE (FLxMJ) OD VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 OE PIPE CLASS 52 DI, LENGTH TO FIT OF JOINT RESTRAINT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING OR (2) 3/4" CORTEN STEEL TIE RODS OG GRAVEL 1 V4" WASHED DRAIN ROCK, MINIMUM V ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL OH CONCRETE BLOCK MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE OBLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 O SHEAR BLOCK 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 OPAVEMENT MARKER BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 PUBLIC WORKS APPROVED: ID FIRE HYDRANT ASSEMBLY DEPARTMENT y 6/28/2023 arcl" P11-h, Public W-,Ad-ist -, DATE METERED BACKFLOW ASSEMBLY (TO BE OBTAINED FROM CITY) (1) 2'2" CONTROL VALVE (1) CONSTRUCTION METER (1) RPBA I METER SUPPORT (BY CONTRACTOR) NSF 61 SUPPLY HOSE i HYDRANT ON EXISTING WATER MAIN TEMPORAo (1) 2" GAL (1) 2" 90- (1) 2" GAT POLYPIG STATION (1) VERTICAL CROSS (MJxFL), SIZE TO MATCH WATER MAIN (1) BLIND FLANGE WITH 2" TAP ON TOP OF CROSS (1) TEMPORARY BLOW -OFF ASSEMBLY (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY THRUST BLOCKING NOTES: 1. THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY HOSE MUST BE DISCONNECTED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. 2. POLYPIG AND ALL DEBRIS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS VIA SANITARY METHOD PRIOR TO DISINFECTION OF NEW WATER MAIN. 3. UPON REMOVAL OF POLYPIG, REMOVE TEMPORARY BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG. 4. THE NEW WATER MAIN SHALL BE CONNECTED TO THE EXISTING SYSTEM ONLY AFTER NEW WATER MAIN IS POLYPIGGED, DISINFECTED AND SATISFACTORY BACTERIOLOGICAL SAMPLE RESULTS ARE OBTAINED. 5. THE INTERIORS OF ALL PIPES AND FITTINGS TO BE USED IN FINAL CONNECTION MUST BE SWABBED OR SPRAYED WITH A 5-6%AVAILABLE CHLORINE SOLUTION. Av STD. PLAN - 300.7 • -r- PUBLIC WORKS APPROVED: DEPARTMENT POLYPIGGING NEW WATER MAINS 6/28/2( 1 1ST SUBMITTAL CORRECTIONS DJL 9/23/25 SURVEYED: SY OTHERS SCALE: 2 2ND SUBMITTAL CORRECTIONS DJL 4 20 26 DE DESIGNED: DAN/EL ✓. LARSON, P.E. 3 95% CD'S DJL 5/15/26 4 3RD SUBMITTAL CORRECTIONS DJL 5/26/26 DRAWN:CHUCK FEML/NG ONE INCH CHECKED: KATIE LANE, E.l. T. AT FULL SCALE SCALE NOT ONE INCH ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: DAN/EL ✓. LARSON, P.E. Martin P-0, DATE n,Mi� worms Aem�mso-m VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.7 - (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING 10'± EXISTING WATER MAIN TEMPORARY BLOCKING EXISTING TEE, CAP, PLUG, OR DEAD END LINE, DO NOT DISTURB BLOCKING CITY OF RENTON (D Planning/Building/Public Works Dept. PUBLIC WORKS DEPARTMENT FINAL CONNECTION NEW DI WATER MAIN iDn N) COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING TEMPORARY BLOW -OFF ASSEMBLIES CONNECTION (BY CITY FORCES) SPOOL )NG BODY DI SLEEVE (MJ) 0Oo :NEW DI WATER MAIN DIY ° ° NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3. LONG BARREL COUPLING FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE STD. PLAN - 300.4 CONNECTION TO WATER MAIN EXISTING TEE OR END LINE CAP DATE O N v O O O O �q ?�•oF'wq'sy�yso CIVIL ENGINEERING �• P `' �� LANDSCAPE ARCHITECTURE PLANNING 'Con o'• 21018929 '� DESIGN SURVEYING 1 ;P;�C/STE9; Fss/ONAL ENG\ 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 /2(o 5o W-427509 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 06/09/2026 Lmm W 17 I\ aDOAB�IULER UTILITY , 7 GAFOUR 06/09/2026 !(ENNYDALE GA TEWA Y DATE 5115126 Q 1310, 1321 & 1331 NE 43RD ST, RENTON, WA 98056 FIELDBOOK: O PAGE DRAWING NO: C5.33 Z WA TER DETAILS SHEET ° 46 OF, 48