HomeMy WebLinkAboutT-427509U-) ILLUMINATION CONSTRUCTION NOTES:
N 1 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1.
O FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE,
ROADWAY SCALE LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE
T SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD PLANS 117.1, 119,
120, AND J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE
ROADWAY SCALE ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF
O RENTON STANDARD PLAN 121.
O EXISTING STREET LIGHT INSTALLED WITH WSDOT IMPROVEMENTS TO REMAIN.
0 3 FURNISH AND INSTALL NEW SERVICE CABINET PER CITY OF RENTON STANDARD
PLANS 122.1, 122.2, 126.1, AND 126.2.
OPOWER SOURCE LOCATION UNKNOWN AT TIME OF PLAN PREPARATION. THE
CONTRACTOR SHALL COORDINATE WITH PSE TO CONFIRM A LOCATION FOR
1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION INCLUDING
Q COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED
FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE
1 , ' POWER SOURCE. CONDUIT SHALL BE CONTINUOUS BETWEEN THE SERVICE
`V CABINET AND THE POWER SOURCE. PSE SHALL MAKE THE FINAL CONNECTION
TO THE POWER SOURCE.
O REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOID.
CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1.
*-4O6 FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE,
ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER
O ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD
PLANS 117.1, 119, 120, AND J013. APPLY DECAL NUMBERING WITH COR POLE
ID PER THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, THIS SHEET, AND
CITY OF RENTON STANDARD PLAN 121.
O REMOVE EXISTING LIGHT POLE AND FOUNDATION. SALVAGE MATERIALS TO THE
,4 CITY OF RENTON.
/ x
r
°
PSE1
0 J
If
IF
cy
X)
SO
02
oe 4\
4 / 1
2
1 /
2
2 4
o /a /
1
1
ILLUMINATION GENERAL NOTES
1.
THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED
BY THE CONTRACTOR
AND CONFIRMED IN THE FIELD BY THE ENGINEER.
2.
ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION.
3.
THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY.
4.
THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE.
5.
ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS
BEFORE COMMENCING
WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
6.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND
THE CITY OF RENTON
IMMEDIATELY UPON DAMAGE.
7.
POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER.
8.
ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION.
9.
CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION.
10.
CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER (ERIC CUTSHALL, 425-430-7423) FOR STREET LIGHTING COMPLIANCE TO STANDARDS
INSPECTION PRIOR TO
ENERGIZING.
11.
FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION.
12.
FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET
LIGHTING.
13.
ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED.
14.
CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY
THE ENGINEER PRIOR TO FOUNDATION INSTALLATION.
15.
THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD
POWER LINES. IF A
CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION.
PSE STREET LIGHTING SCOPE OF WORK
ILLUMINATION POLE SCHEDULE (INSTALLED BY PSE STREET LIGHTING)
LUM.
STREET
STATION
OFFSET
MOUNTING
ARM
POLE
LUMINAIRE TYPE
GE CATALOGUE #
WATTAGE
/TYPE
INITIAL
COMMENT
POLE N0.
HEIGHT
LENGTH
LUMENS
P1
LAKE WASHINGTON
EX
EX
EX 30'
EX 14'
EX
GE EVOLVE
GE EVOLVE
59W
8,000
REPLACE EXISTING FIXTURE WITH NEW LUMINAIRE.
BLVD N
ERL1_08C540
ERL1008C540AGRAYX378
LED
TO BE INSTALLED BY PSE STREET LIGHTING.
PSE STREET LIGHTING CONSTRUCTION NOTE
PSE1 EXISTING UTILITY POLE TO REMAIN. PSE TO REMOVE EXISTING UTILITY POLE MOUNTED ARM AND FIXTURE.
EXISTING UTILITY POLE AND ARM TO REMAIN. REPLACE EXISTING UTILITY POLE MOUNTED FIXTURE WITH NEW LUMINAIRE PER ILLUMINATION POLE SCHEDULE, THIS
SE2 SHEET. LUMINAIRE SHALL BE INSTALLED BY PSE STREET LIGHTING.
PSE STREET LIGHTING GENERAL NOTE
1. PROJECT CONTRACTOR SHALL COORDINATE WITH PSE STREET LIGHTING TO SCHEDULE INSTALLATION, INCLUDING COMPLETING ALL FORMS, PAYMENT OF ALL FEES,
ETC. ASSOCIATED WITH THE INSTALLATION. PSE STREET LIGHTING SHALL FURNISH AND INSTALL ALL MATERIALS BY CONTRACT WITH THE DEVELOPER.
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
POLE
MOUNT.
ARM
SERVICE/
WATTAGE
INITIAL
FIXTURE MODEL
DIST.
COLOR
POLE
POLE NO.
NUMBER ***
STREET
STATION *
OFFSET *
LATITUDE **
LONGITUDE **
HEIGHT
HEIGHT
LENGTH
VOLTAGE
CIRCUIT
ITYPE
LUMENS
(OR APPROVED EQUAL)
TYPE
TEMP.
TYPE
BASE
COMMENT ****
1
LAKE WASHINGTON
65+45.0
38.5' RT
40'
35.5'
2'
240
ILUM A
85W LED
10,302
CYCLONE DOMIA
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
CY55P1B-FCG-T3M-P60-4K
ALUMINUM
STANDARD PLANS 117.1.
O
LAKE WASHINGTON
66+60.5
41.5' RT
40'
35.5'
2'
240
ILUM A
85W LED
10,302
CYCLONE DOMIA
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
CY55P1B-FCG-T3M-P60-4K
ALUMINUM
STANDARD PLANS 117.1.
O
LAKE WASHINGTON
67+59.5
14.0' RT
40'
35.5'
2'
240
ILUM A
85W LED
10,302
CYCLONE DOMIA CY55P1B-FGC-T3M-P60-4K
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
16.5'
2'
44W LED
5,364
& CY55P1A-FGC-T3M-P30-4K
ALUMINUM
STANDARD PLANS 117.1.
G
LAKE WASHINGTON
68+25.0
49.5' RT
40'
35.5'
2'
240
ILUM A
85W LED
10,302
CYCLONE DOMIA
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
CY55P1B-FCG-T3M-P60-4K
ALUMINUM
STANDARD PLANS 117.1.
OS
N 43RD ST
10+70.5
21.0' RT
40'
35.5'
8'
240
ILUM A
63W LED
7,441
CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
16.5'
2'
44W LED
5,364
& CY55P1A-FGC-T3M-P30-4K
ALUMINUM
STANDARD PLANS 117.1.
O
LAKE WASHINGTON
70+06.5
37.0' RT
40'
35.5'
8'
240
ILUM A
63W LED
7,441
CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K
Ill
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
16.5'
2'
44W LED
5,364
& CY55P1A-FGC-T3M-P30-4K
ALUMINUM
STANDARD PLANS 117.1.
O
LAKE WASHINGTON
69+22
55.5' LT
40'
35.5'
g'
240
ILUM A
63W LED
7,441
CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K
III
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
.5
l6.5'
2'
44W LED
5,364
& CY55P1A-FGC-T3M-P30-4K
ALUMINUM
STANDARD PLANS 117.1.
O
N 43RD ST
8+82.0
26.5' RT
40'
35.5'
8'
240
ILUM A
63W LED
7,441
CYCLONE DOMIA
III
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY55P1B-FCG-T3M-P50-4K
ALUMINUM
STANDARD PLANS 117.1.
O
LAKE WASHINGTON69+94
63.0' LT
40'
�15.5'
g'
240
ILUM A
63W LED
7,441
CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K
III
4000K
DECORATIVE
FIXED
NEW FOUNDATION AND POLE PER RENTON
BLVD N
.0
16 5'
2'
44W LED
5,364
& CY55P1A-FGC-T3M-P30-4K
ALUMINUM
STANDARD PLANS 117.1.
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS.
*** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 121.
**** STRUCTURAL LETTER AND CALCULATIONS TO BE PROVIDED FOR FUTURE SUBMITTALS.
UNDERGROUND LOCATOR SERVICE
CALL BEFOREYOU DIG.
81/q
ILLUMINATION WIRING SCHEDULE
RACEWAY
SIZ DUIT
ILLUM.
#8
SERVICE
PO#WR
PHOTO
CELL
EQUIP.
GROUND
N0.
1
2" SCH80 PVC
2
1
2
r3
2" SCH80 PVC
2
1
1
3" SCH80 PVC
3
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER
THAN THE LARGEST WIRE SIZE IN THE CONDUIT.
SERVICE 1 BREAKER SCHEDULE
(NEW SERVICE ON LAKE WASHINGTON BLVD N)
CIRCUIT
BREAKER
CONTACTOR
MAIN
2P-100 AMP
---
ILLUM A
2P-20 AMP
30 AMP
ILLUM B (SPARE)
2P-20 AMP
30 AMP
RRFB
1 P-15 AMP
30 AMP
"06
REVISION
L�
0 10 20 40 60
SCALE IN FEET
SURVEYED:
BY OTHERS
DESIGNED:
VNH D VB T
DRAWN:
VNH D VS
CHECKED:
TTT
BY DATE AP P R APPROVED:
CTB
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
ILLUMINATION LEGEND
EX NEW DESCRIPTION
E XL JUNCTION BOX TYPE 1,2
' LUMINAIRE POLE
UTILITY POLE
UTILITY OLE MOUNTED
LUMINAIR
------
CONDUIT/CONDUCTOR
®
SERVICE CABINET
OCONSTRUCTION
NOTE
OLUMINAIRE
POLE NUMBER
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
CITY OR
P'Rl RENTON
Planning/Building/Public Works Dept.
� >•oF wasy�.:
'ice;
- EN
520 KI RKLAN D WAY, SUITE 100
KIRKLAND, WA, 98033
Q
V
1
TREVOR TAKARA, P.E.
05 26 2026 TAKARA@TENW.COM 1 206-914-3843
T-427509
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING
CBarnes 06/08/2026'
yqi 06/09/2026 W
KENNYDALE GA TEWA Y DATE 0512612026 Q
4350 LAKE WASHINGTON BL VD N, RENTON, WA 98056 FIELDBOOK: O
PAGE:
ILLUMINATION PLAN DRAWING NO:
/� 01 W
SHEET: OF:
8 16