HomeMy WebLinkAboutT-427509U-) ILLUMINATION CONSTRUCTION NOTES: N 1 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. O FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY SCALE LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE T SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD PLANS 117.1, 119, 120, AND J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF O RENTON STANDARD PLAN 121. O EXISTING STREET LIGHT INSTALLED WITH WSDOT IMPROVEMENTS TO REMAIN. 0 3 FURNISH AND INSTALL NEW SERVICE CABINET PER CITY OF RENTON STANDARD PLANS 122.1, 122.2, 126.1, AND 126.2. OPOWER SOURCE LOCATION UNKNOWN AT TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO CONFIRM A LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION INCLUDING Q COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE 1 , ' POWER SOURCE. CONDUIT SHALL BE CONTINUOUS BETWEEN THE SERVICE `V CABINET AND THE POWER SOURCE. PSE SHALL MAKE THE FINAL CONNECTION TO THE POWER SOURCE. O REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOID. CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. *-4O6 FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER O ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD PLANS 117.1, 119, 120, AND J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD PLAN 121. O REMOVE EXISTING LIGHT POLE AND FOUNDATION. SALVAGE MATERIALS TO THE ,4 CITY OF RENTON. / x r ° PSE1 0 J If IF cy X) SO 02 oe 4\ 4 / 1 2 1 / 2 2 4 o /a / 1 1 ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION. 3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER. 8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER (ERIC CUTSHALL, 425-430-7423) FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING. 13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. PSE STREET LIGHTING SCOPE OF WORK ILLUMINATION POLE SCHEDULE (INSTALLED BY PSE STREET LIGHTING) LUM. STREET STATION OFFSET MOUNTING ARM POLE LUMINAIRE TYPE GE CATALOGUE # WATTAGE /TYPE INITIAL COMMENT POLE N0. HEIGHT LENGTH LUMENS P1 LAKE WASHINGTON EX EX EX 30' EX 14' EX GE EVOLVE GE EVOLVE 59W 8,000 REPLACE EXISTING FIXTURE WITH NEW LUMINAIRE. BLVD N ERL1_08C540 ERL1008C540AGRAYX378 LED TO BE INSTALLED BY PSE STREET LIGHTING. PSE STREET LIGHTING CONSTRUCTION NOTE PSE1 EXISTING UTILITY POLE TO REMAIN. PSE TO REMOVE EXISTING UTILITY POLE MOUNTED ARM AND FIXTURE. EXISTING UTILITY POLE AND ARM TO REMAIN. REPLACE EXISTING UTILITY POLE MOUNTED FIXTURE WITH NEW LUMINAIRE PER ILLUMINATION POLE SCHEDULE, THIS SE2 SHEET. LUMINAIRE SHALL BE INSTALLED BY PSE STREET LIGHTING. PSE STREET LIGHTING GENERAL NOTE 1. PROJECT CONTRACTOR SHALL COORDINATE WITH PSE STREET LIGHTING TO SCHEDULE INSTALLATION, INCLUDING COMPLETING ALL FORMS, PAYMENT OF ALL FEES, ETC. ASSOCIATED WITH THE INSTALLATION. PSE STREET LIGHTING SHALL FURNISH AND INSTALL ALL MATERIALS BY CONTRACT WITH THE DEVELOPER. ILLUMINATION POLE SCHEDULE LUM. POLE ID POLE MOUNT. ARM SERVICE/ WATTAGE INITIAL FIXTURE MODEL DIST. COLOR POLE POLE NO. NUMBER *** STREET STATION * OFFSET * LATITUDE ** LONGITUDE ** HEIGHT HEIGHT LENGTH VOLTAGE CIRCUIT ITYPE LUMENS (OR APPROVED EQUAL) TYPE TEMP. TYPE BASE COMMENT **** 1 LAKE WASHINGTON 65+45.0 38.5' RT 40' 35.5' 2' 240 ILUM A 85W LED 10,302 CYCLONE DOMIA Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N CY55P1B-FCG-T3M-P60-4K ALUMINUM STANDARD PLANS 117.1. O LAKE WASHINGTON 66+60.5 41.5' RT 40' 35.5' 2' 240 ILUM A 85W LED 10,302 CYCLONE DOMIA Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N CY55P1B-FCG-T3M-P60-4K ALUMINUM STANDARD PLANS 117.1. O LAKE WASHINGTON 67+59.5 14.0' RT 40' 35.5' 2' 240 ILUM A 85W LED 10,302 CYCLONE DOMIA CY55P1B-FGC-T3M-P60-4K Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N 16.5' 2' 44W LED 5,364 & CY55P1A-FGC-T3M-P30-4K ALUMINUM STANDARD PLANS 117.1. G LAKE WASHINGTON 68+25.0 49.5' RT 40' 35.5' 2' 240 ILUM A 85W LED 10,302 CYCLONE DOMIA Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N CY55P1B-FCG-T3M-P60-4K ALUMINUM STANDARD PLANS 117.1. OS N 43RD ST 10+70.5 21.0' RT 40' 35.5' 8' 240 ILUM A 63W LED 7,441 CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON 16.5' 2' 44W LED 5,364 & CY55P1A-FGC-T3M-P30-4K ALUMINUM STANDARD PLANS 117.1. O LAKE WASHINGTON 70+06.5 37.0' RT 40' 35.5' 8' 240 ILUM A 63W LED 7,441 CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K Ill 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N 16.5' 2' 44W LED 5,364 & CY55P1A-FGC-T3M-P30-4K ALUMINUM STANDARD PLANS 117.1. O LAKE WASHINGTON 69+22 55.5' LT 40' 35.5' g' 240 ILUM A 63W LED 7,441 CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K III 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N .5 l6.5' 2' 44W LED 5,364 & CY55P1A-FGC-T3M-P30-4K ALUMINUM STANDARD PLANS 117.1. O N 43RD ST 8+82.0 26.5' RT 40' 35.5' 8' 240 ILUM A 63W LED 7,441 CYCLONE DOMIA III 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON CY55P1B-FCG-T3M-P50-4K ALUMINUM STANDARD PLANS 117.1. O LAKE WASHINGTON69+94 63.0' LT 40' �15.5' g' 240 ILUM A 63W LED 7,441 CYCLONE DOMIA CY55P1B-FGC-T3M-P50-4K III 4000K DECORATIVE FIXED NEW FOUNDATION AND POLE PER RENTON BLVD N .0 16 5' 2' 44W LED 5,364 & CY55P1A-FGC-T3M-P30-4K ALUMINUM STANDARD PLANS 117.1. * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 121. **** STRUCTURAL LETTER AND CALCULATIONS TO BE PROVIDED FOR FUTURE SUBMITTALS. UNDERGROUND LOCATOR SERVICE CALL BEFOREYOU DIG. 81/q ILLUMINATION WIRING SCHEDULE RACEWAY SIZ DUIT ILLUM. #8 SERVICE PO#WR PHOTO CELL EQUIP. GROUND N0. 1 2" SCH80 PVC 2 1 2 r3 2" SCH80 PVC 2 1 1 3" SCH80 PVC 3 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. SERVICE 1 BREAKER SCHEDULE (NEW SERVICE ON LAKE WASHINGTON BLVD N) CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B (SPARE) 2P-20 AMP 30 AMP RRFB 1 P-15 AMP 30 AMP "06 REVISION L� 0 10 20 40 60 SCALE IN FEET SURVEYED: BY OTHERS DESIGNED: VNH D VB T DRAWN: VNH D VS CHECKED: TTT BY DATE AP P R APPROVED: CTB SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ILLUMINATION LEGEND EX NEW DESCRIPTION E XL JUNCTION BOX TYPE 1,2 ' LUMINAIRE POLE UTILITY POLE UTILITY OLE MOUNTED LUMINAIR ------ CONDUIT/CONDUCTOR ® SERVICE CABINET OCONSTRUCTION NOTE OLUMINAIRE POLE NUMBER VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OR P'Rl RENTON Planning/Building/Public Works Dept. � >•oF wasy�.: 'ice; - EN 520 KI RKLAN D WAY, SUITE 100 KIRKLAND, WA, 98033 Q V 1 TREVOR TAKARA, P.E. 05 26 2026 TAKARA@TENW.COM 1 206-914-3843 T-427509 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING CBarnes 06/08/2026' yqi 06/09/2026 W KENNYDALE GA TEWA Y DATE 0512612026 Q 4350 LAKE WASHINGTON BL VD N, RENTON, WA 98056 FIELDBOOK: O PAGE: ILLUMINATION PLAN DRAWING NO: /� 01 W SHEET: OF: 8 16