Loading...
HomeMy WebLinkAboutT-427510U-) ILLUMINATION CONSTRUCTION NOTES: N 1 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. O FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY SCALE LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE T SCHEDULE, SHEET IL-01, AND CITY OF RENTON STANDARD PLANS 117.1, 119, 120, AND J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-01, AND CITY OF O RENTON STANDARD PLAN 121. O EXISTING STREET LIGHT INSTALLED WITH WSDOT IMPROVEMENTS TO REMAIN. 0 3 FURNISH AND INSTALL NEW SERVICE CABINET PER CITY OF RENTON STANDARD PLANS 122.1, 122.2, 126.1, AND 126.2. OPOWER SOURCE LOCATION UNKNOWN AT TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO CONFIRM A LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION INCLUDING Q COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE 1 , ' POWER SOURCE. CONDUIT SHALL BE CONTINUOUS BETWEEN THE SERVICE `V CABINET AND THE POWER SOURCE. PSE SHALL MAKE THE FINAL CONNECTION TO THE POWER SOURCE. O REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOID. CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1. V O6 FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER O ILLUMINATION POLE SCHEDULE, SHEET IL-01, AND CITY OF RENTON STANDARD PLANS 117.1, 119, 120, AND J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-01, AND CITY OF RENTON STANDARD PLAN 121. O REMOVE EXISTING LIGHT POLE AND FOUNDATION. SALVAGE MATERIALS TO THE W CITY OF RENTON. ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT IZ DUIT ILLUM. #8 SERVICE POWER PHOTO CELL EQUIP. GROUND N0. 1 2" SCH80 PVC 2 1 2 2" SCH80 PVC 2 1 1 3 3" SCH80 PVC 3 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. 1 T� 1 0000. i 5 i �o 7 = 1 XIAo _ P1 .0 S UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 / J G 2 �1 8 / 8 / / el el el 2 � � o j, AIf ���� 'Po �C� A � RIB � i I . O000, o 1 I 6 6 O REVISION 0 10 20 40 60 SCALE IN FEET SURVEYED: SCALE: VERTICAL: NAV1988 BY OTHERS HORIZONTAL: NAD D1983/1991 DESIGNED: AS NOTED VNH D VB TTT DRAWN: VNH DVB ONE INCH DATUM CHECKED: AT FULL SCALE TTT IF NOT ONE INCH BY DATE AP P R APPROVED: SCALE ACCORDINGLY CTB 2 ILLUMINATION LEGEND EX NEW DESCRIPTION E m 0 JUNCTION BOX TYPE 1,2 — '—` LUMINAIRE POLE UTILITY POLE UTILITY OLE MOUNTED LUMINAIR ------ CONDUIT/CONDUCTOR ® SERVICE CABINET OCONSTRUCTION NOTE O LUMINAIRE POLE NUMBER Aowtk CITY OR RENTON Nboav Planning/Building/Public Works Dept. ILLUMINATION WIRING DIAGRAM �SSIDNAL ECG` 5 � P1� PSE SITE LAKE WASHINGTON BLVD N NEW SERVICE 1 ILLUM A I ALUM B SPARE N NOT TO SCALE ►A EN 520 KI RKLAN D WAY, SUITE 100 KIRKLAND, WA, 98033 Q V 1 TREVOR TAKARA, P.E. 05 26 2026 TAKARA@TENW.COM 1 206-914-3843 T-427510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING CBarnes 06/08/2026 yqi 06/09/2026U+ 144 KENNYDALE GA TEWA Y DATE Q 0512612026 4350 LAKE WASHINGTON BL VD N, RENTON, WA 9,9056 FIELDBOOK: O PAGE: ILLUMINATION PLAN DRAWING NO: /L 02 W SHEET: OF: 9 16