HomeMy WebLinkAboutT-427515RRFB CONSTRUCTION NOTES LO N 07% CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH ONE 36"X36" W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, ONE RRFB UNIT, ONE CONTROL UNIT, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE T POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE SOUTHWEST PARALLEL TO CROSSWALK. O FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" OCONSTRUCT B W 1 1-2 SIGNS, TWO 21 "X 15" W 16-7P(R) SIGNS, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, AND TWO RRFB UNITS ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. C CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH ONE 36"X36" W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 21 "X 15" W 16-7P(R) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, ONE RRFB UNIT, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE Q NORTHEAST PARALLEL TO CROSSWALK. 1� D CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" `V O W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 21 "X 15" W 16-7P(R) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, TWO RRFB UNITS, ONE CONTROL UNIT, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, Q 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN I� PUSHBUTTON SHALL FACE NORTHWEST PARALLEL TO CROSSWALK. `4 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" V O W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 21 "X 15" W 16-7P(R) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, TWO O RRFB UNITS, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE '� SOUTHWEST PARALLEL TO CROSSWALK. OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH ONE 36"X36" CONSTRUCT FOUNDATION PER CITY O W 1 1-2 SIGNS, ONE 21 "X 15" W 16 7P(L) SIGN, ONE 12 "X 12" W 1 1 501 SIGN, ONE 9 "X 12" R 10 25 SIGN, ONE RRFB UNIT, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE NORTHEAST PARALLEL TO CROSSWALK. G CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" W 1 1-2 SIGNS, TWO 21 "X 15" W 16-7P(R) SIGNS, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, AND TWO RRFB UNITS ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. C CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH ONE 36"X36" W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, ONE RRFB UNIT, ONE CONTROL UNIT, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE SOUTHWEST PARALLEL TO CROSSWALK. OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 21 "X 15" W 16-7P(R) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, TWO RRFB UNITS, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE SOUTHEAST PARALLEL TO CROSSWALK. J CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 141.2 AND 141.3. FURNISH AND INSTALL TYPE FB POLE WITH TWO 36"X36" W 1 1-2 SIGNS, ONE 21 "X 15" W 16-7P(L) SIGN, ONE 21 "X 15" W 16-7P(R) SIGN, ONE 12 "X 12" W 1 1-501 SIGN, ONE 9 "X 12" R 10-25 SIGN, TWO RRFB UNITS, AND ONE PEDESTRIAN PUSHBUTTON ON THE SIGNAL POLE PER CITY OF RENTON STANDARD PLANS 141.1, 141.2, 141.3, 141.4, AND 141.5. SEE POLE DETAILS, SHEET FB-02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. NEW PEDESTRIAN PUSHBUTTON SHALL FACE NORTHWEST PARALLEL TO CROSSWALK. CDNEW SERVICE CABINET, SEE ILLUMINATION PLANS. CONTRACTOR SHALL UTILIZE SPARE 15 AMP BREAKER (30 AMP CONTACTOR) FOR RRFB CIRCUIT. LAKE WA BLVD SIGNAL DISPLAY �=1 0 RECTANGULAR RAPID FLASHING BEACON NEW: F 1, F2, F3, F4 F5, F6, F7, F8 F9,F10,F11,F12 F13,F14,F15,F16 SIGNAL STANDARD POLE SCHEDULE STD. NO. O REFERENCE ROADWAY FIELD LOCATION TYPE REMARKS STATION OFFSET LT RT A LK WA BLVD 68+82.5 35.0' X FB FDN PER WSDOT J-21.10 B LK WA BLVD 68+89.5 4.5' X FB FDN PER WSDOT J-21.10 C LK WA BLVD 68+72.0 30.5'1 X FB FDN PER WSDOT J-21.10 D N 43RD ST 9+ 13.5 24.5' X FB FDN PER WSDOT J-21.10 E N 43RD ST 8+99.0 29.0' X FB FDN PER WSDOT J-21.10 F LK WA BLVD 70+28.5 43.5' X FB FDN PER WSDOT J-21.10 G LK WA BLVD 70+ 15.5 5.5' X FB FDN PER WSDOT J-21.10 H LK WA BLVD 70+36.0 32.5' X FB FDN PER WSDOT J-21.10 I N 43RD ST 10+87.0 20.5' X FB FDN PER WSDOT J-21.10 J N 43RD ST 10+98.0 21.5' X FB FDN PER WSDOT J-21.10 SIGNAL WIRING SCHEDULE RACEWAY CONDUIT SIZE FLASH/ PPB 5C CONT. PWR. #6 EQUIP. GRND.* CONDUIT FILL ALLOW. FILL NO. 1 2" SCH40 PVC 1 1 0.28 0.86 2 2" SCH80 PVC 1 1 0.28 0.75 3 2" SCH40 PVC 1 2 1 0.43 0.86 4 2" SCH80 PVC 1 2 1 0.43 0.75 5 2" SCH40 PVC 2 2 1 0.57 0.86 6 12" SCH80 PVC 2 1 2 1 0.57 0.75 7 2" SCH80 PVC 2 1 0.42 0.75 8 2" SCH40 PVC 2 1 0.22 0.86 9 2" SCH40 PVC 4 1 0.37 0.86 10 2" SCH40 PVC 1 8 1 1 0.66 1 0.86 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. SERVICE 1 BREAKER SCHEDULE (NEW SERVICE ON LAKE WASHINGTON BLVD N) CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B (SPARE) 2P-20 AMP 30 AMP RRFB 1 P-15 AMP 30 AMP SIGN LEGEND < > W 16-7P(L) 21 "x 15" CROSS TRAFFIC S2 MAY NOT STOP USE CAUTION WHEN CROSSING W11-2 � W11-501 36"x36„ 12"x12" W 16-7P(R) S4 S1 21 "x15" S3 AFFIX NEW PUSH BUTTON R 10-25 PLAQUE FOR WARNING TO PEDESTRIAN LIGHTS PUSHBUTTON WAIT FOR GAP ASSEMBLIES IN TRAFFIC NEW BACKGROUND : WHITE R10-25 9 "x 12" TEXT/SYMBOL BLACK SEE PLAN SHEET FB-02 FOR ADDITIONAL SIGNING REQUIREMENTS. UNDERGROUND LOCATOR SERVICE CALL BEFOREYOU DIG. 81/q TO 61 REVISION - ME N 0 10 20 40 60 SCALE IN FEET SURVEYED: BY OTHERS DESIGNED: VNH D VB T DRAWN: VNH D VB CHECKED: TTT AP P R APPROVED: CTB SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ILLUMINA 1IUN LLCat NU EX NEW DESCRIPTION E XL JUNCTION BOX TYPE 1,2 0---):� " LUMINAIRE POLE UTILITY POLE UTILITY OLE MOUNTED LUMINAIR ------ CONDUIT/CONDUCTOR ® SERVICE CABINET OCONSTRUCTION NOTE OLUMINAIRE POLE NUMBER VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OR RENTON Planning/Building/Public Works Dept. 05-26 2026 40 SF T �w EN 520 KI RKLAN D WAY, SUITE 100 KIRKLAND, WA, 98033 TREVOR TAKARA, P.E. TAKARA@TENW.COM 1 206-914-3843 T-427515 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION CBarnes 06/08/2026 Q V 1 DEVELOPMENT ENGINEERING yqi 06/09/2026 Ar IL �E W KENNYDALE GA TEWA Y 4350 LAKE WASHINGTON BL VD N, RENTON, WA 9,9056 RRFB PLAN DATE: w-I 0512612026 Q\ FIELDBOOK: PAGE: DRAWING NO: FB-o1 W SHEET: OF: 14 16