Loading...
HomeMy WebLinkAboutT-427516LO N T O W W V Q Z RRFB POLE MOUNTING AND ATTACHMENT DETAILS POLE C& F POLE B& G POLE A& H CARMANAH SC315-G CONTROLLER A CABINETW11-2 111-? W11-2 36"x36" 36 x36 36"x36RRFB F4 & F7RRFB F2 & F3, o RRFB F 1 & F 1 F2 & F8 0 0 W121 X1(5� W16 �7P(L� W 16 - 7P(R » Fk� 21"X15 21 X15 W 1 1-501 W 1 1-501, 12" X 12" NEW ISLAND. 12" X 12' Q W PEDESTRIAN ❑ v PUSHBUTTON -L8--T 0 Lf) r< LOOKING NORTH OF INTERSECTION NOT TO SCALE POLE E & I POLE D & J CARMANAH SC315-G CONTROLLER CABINET • • W 1 1-2 W11-2 3611x36" 36"x36" RRFB F 16 & F13 W 16 - 7P(R) 21 "X15 ' W11-501 12" X 12" RRFB F11 & F LOOKING WEST OF INTERSECTION NOT TO SCALE RRFB & SIGN ATTACHMENT INFORMATION 1. RRFB UNITS SHALL BE MOUNTED PER MANUFACTURERS RECOMMENDATIONS. 2. ALL SIGNAL POLE MOUNTED SIGNS SHALL BE INSTALLED WITH MOUNTING BRACKET AND STEEL STRAP PER WSDOT G-24.10 AND SIGN BRACE PER WSDOT G-50.10. UNDERGROUND LOCATOR SERVICE CALL BEFOREYOU DIG. 81/q TIN REVISION SURVEYED: BY OTHERS DESIGNED: VNH D VB T DRAWN: VNH D VB CHECKED: TTT AP P R APPROVED: CTB W 16 - 7P(R) 21 "X15 ' W11-501 12" X 12" PEDESTRIAN PUSHBUTTON SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY n VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M w J 0 0- L` 0 a_ 0 0 a w J 0 0- Ll- 0 CL 0 0 a SIGNAL GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION AND ITS AMENDMENTS, WSDOT STANDARD PLANS, CITY OF RENTON STANDARD PLANS, AND THE NATIONAL ELECTRICAL CODE, ALL CURRENT AS OF THE APPROVAL DATE ON THESE DOCUMENTS. 2. THE LOCATIONS OF EXISTING FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 3. THE CONTRACTOR SHALL SUBMIT MATERIAL APPROVAL REQUESTS TO THE ENGINEER AT THE EARLIEST POSSIBLE DATE. 4. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND CITY OF RENTON IMMEDIATELY UPON DAMAGE. 6. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10—FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 7. ALL TRAFFIC SIGNAL AND PEDESTRIAN HEADS AND PUSH BUTTONS SHALL BE SECURELY AND COMPLETELY COVERED WHILE NOT IN OPERATION. 8. EXISTING FEATURES TO REMAIN UNLESS OTHERWISE NOTED. 9. ALL SIGNALIZED CROSSWALKS SHALL BE OPERATIONAL AT ALL TIMES UNLESS FLAGGERS/POLICE ARE PRESENT TO ASSIST PEDESTRIANS. 10. CONTRACTOR SHALL PROVIDE TENW WITH REDLINE MARKUPS SHOWING ANY AND ALL CHANGES FROM THESE APPROVED PLANS FOLLOWING CONSTRUCTION. 11. ALL TRAFFIC SIGNAL EQUIPMENT AND SIGNS SHALL BE IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) 12. SIGNAL POLES AND FOUNDATIONS SHALL BE EQUIPPED WITH IDENTIFICATION TAGS PER STD. PLAN 139. CITY OR RENTON Planning/Building/Public Works Dept. -w/ 05 26 2026 T �w EN 520 KI RKLAN D WAY, SUITE 100 KIRKLAND, WA, 98033 TREVOR TAKARA, P.E. TAKARA@TENW.COM 1 206-914-3843 T-427516 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LTRANSPORTATION OPERATION + CBarnes 06/08/2026 Q V 1 DEVELOPMENT ENGINEERING F yq i 06/09/2026 l� KENNYDALE GA TEWA Y 4350 LAKE WASHINGTON BL VD N, RENTON, WA 9,9056 RRFB DETAILS W w-I Q\ DATE: 0512612026 FIELDBOOK: PAGE: DRAWING NO: FB- 02 W SHEET: OF: 15 16