Loading...
HomeMy WebLinkAboutR-42757124" DIAMETER VEGETATION -FREE ZONE AT BASE OF ALL TREES BACKFILL PLANTING PIT WITH WITH MIX OF 1/2 NATIVE SOIL AND 1/2 IMPORTED SOIL. 1:1 SLOPE ON SIDES OF PLANTING PIT UNDISTURBED OR COMPACTED SUBGRADE. DECIDUOUS TREE PLANTING SCALE: 1 /2" T-0" NOTES 1. EACH TREE MUST BE PLANTED SUCH THAT THE • TRUNK FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. TREES WHERE THE TRUNK FLARE IS NOT VISIBLE WILL BE REJECTED. DO NOT COVER THE TOP OF THE ROOT BALL WITH SOIL. • 2. DO NOT HEAVILY PRUNE THE TREE AT • PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO -DOMINANT LEADERS, AND BROKEN OR • DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER, DO NOT REMOVE THE TERMINAL • BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. • 3. WHERE TREES OCCUR IN TURF AREAS, PROVIDE 3DIAMETER MULCH CIRCLE, 3" DEPTH. 4. SET PLANT PLUMB. • 5. REMOVE UNTREATED BURLAP FROM TOP 2/3 OF ROOTBALL. REMOVE TREATED BURLAP OR WIRE BASKETS COMPLETELY. CONTAINER PLANTS -SCORE ROOTBALL IN 3 PLACES TO 1/2' DEPTH. 6. VERIFY TREES TO BE STAKED WITH PROJECT REPRESENTATIVE. FINISH GRADE OF SOIL PROVIDE WATER SAUCER TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT. TREE PROTECTION ZONE (TPZ) FENCE DETAIL PROTECTION MEASURES DURING CONSTRUCTION: 1. Chain link fencing is required around the drip line of trees required to be retained, or around required tree protection tracts/easements. ` 2. The fence shall be a minimum of 6-feet high. G 3. Steel posts shall be driven at a depth to ensure the fence remains in an upright position for the duration of the development. 4. Tree protection signage shall be placed at intervals of no �. more than 20-feet along the entire fence. See link below for signage specifications. 5. Storage, fill, excavation, earth compaction, or dumping of liquids or materials is prohibited in fenced area. 1 6-FOOT 6. Utilities or impervious surface installation is prohibited REQUIRED �L, CHAIN LINK within the tree drip line. SIGNAGE ` FENCE 7. Grade changes are prohibited within the tree drip line. Ilk 8. Removal of the existing vegetation within the drip line of TREE protected trees is prohibited. PROTECTION 9. All areas within the required fencing shall be covered SIGNAGE evenly with a minimum of 3-inches of bark mulch, except x in areas where mulch will adversely affect protected ) ground cover plants. 10. For protected trees subject to a land use decision, the applicant shall retain an ISA certified arborist or ASCA certified consultant to supervise fence installation, DRIVEN STEEL MAINTAIN UNDISTURBED VEGETATION monitor tree health, and prune trees. POSTS EXISTING WITH 3-INCHES GRADE MULCH Planning Division CITY OF Renton , South Grady Way Rento---���D n, WA 98057 425-430-7200 1 www.rentonwa.gov PAGE 1 OF 3 TREE PROTECTION SIGNAGE INSTRUCTIONS INSTRUCTIONS: 11. Install tree protection signage at intervals of no more than 20-feet along the entire fence. 12. The size of each sign must be a minimum of 18" x 24". 13. Fill in the approved permit number on the front side. 14. Plastic laminate the sign for weather resistance. 15. Affix the filled -in and laminated sign to the tree protection fencing using zip or twist ties, wire, or twine. 16. Place sign on fencing so it is visible to construction personnel and, to the greatest extent possible, from the street. 17. Keep the sign in readable condition for the entire REQUIRED duration of the project. SIGNAGE 18. For protected trees subject to a land use decision, the applicant shall retain an ISA certified arborist or ASCA certified consultant to supervise fence installation, monitor tree health, and prune trees. DRIVEN STEEL POSTS MAINTAIN EXISTING GRADE 6-FOOT CHAIN LINK FENCE UNDISTURBED VEGETATION WITH 3-INCHES MULCH CITY OF Planning Division i 1055 South Grady Way enton Renton, WA98057 425-430-7200 1 www.rentonwagov PAGE 2 OF 3 EXISTING TREE PROTECTION SCALE: 1 /2" - V-0" o N LU LU LL O cD w FINISH GRADES co DECIDUOUS TREE STAKING SCALE: 1/2" - 1'-0" TREE TIES PER SPECIFICATIONS (2) WOODEN STAKES, REFER TO SPECIFICATIONS. CONFIRM TREES TO BE STAKED WITH OWNER'S REPRESENTATIVE. ::• -I � �-III ,III 1 DECIDUOUS L5.01 TREE PLANTING SHRUB PLANTING AREAS �MULCH LAYER PER PLANTING DETAILS REMOVE ALL MATERIAL LARGER TI �I THAN 1" IN TOP 3" OF PROFILE AMEND SOILS WITH 3" T TOPSOIL TYPE A INTO 5" OF EXISTING ROUGH GRADED SOIL PROFILE FOR A TOTAL -I1 IMPROVED DEPTH OF 8" UNDISTURBED EXISTING SOIL TURF AREAS* REMOVE ALL MATERIAL LARGER THAN 1" IN TOP 3" OF PROFILE TIII TllI T AMEND SOILS WITH 3" 1T� TOPSOIL TYPE B INTO 5" OF 00 EXISTING ROUGH GRADED SOIL PROFILE FOR A TOTAL IMPROVED DEPTH OF 8" -I - UNDISTURBED EXISTING SOIL * AT AREAS INDICATED TO RECEIVE HYDROSEED THAT ARE NOT IMPACTED BY CONSTRUCTION ACTIVITY, DO NOT AMENDMLL. HARD RAKE PRIOR TO HYDROSEEDING. FIELD AREA 12" MIN TOPSOIL TYPE C ...... ....... ...... . ...... . ...... �d SCARIFY SUBGRADE 4" MIN. " • •" •' •' •' • REMOVE ALL MATERIAL LARGER THAN 1 " - II UNDISTURBED EXISTING SOIL SOIL AMENDMENTS SCALE: 1" = 1'-0" CONIFER TREE PLANTING AND STAKING SCALE: 1 /2" = 1'-0" INSTALL 1 " ABOVE CONTAINER DEPTH 2" LAYER OF SPECIFIED MULCH BACKFILL _ _ PLANTING PIT WITH SPECIFIED MIX OF NATIVEAND IMPORTED SOIL lil i MOUND CENTER OF PLANTING PIT COMPACT TO SUBGRADE DENSITY SHRUB PLANTING SCALE: 1 /2" = T-0" 1.5 D ROOTBALL DIAMETER (D) 2-STRANDS #10 GAUGE WIRE W/ VINYL HOSE GUY AT 3 EQUALLY SPACED POINTS PER TREE FLAG WIRES FINISH GRADE OF MULCH TREE GUY STAKE AS SPECIFIED PROVIDE WATER SAUCER FINISH GRADE OF SOIL REMOVE UNTREATED III_ III=III= BURLAP FROM TOP 2/3 OF ROOTBALL. REMOVE -III_ TREATED BURLAP OR WIRE BASKETS COMPLETELY. III -I I I- CONTAINER PLANTS: SCORE ROOTBALLS IN 3 PLACES TO 1/2" DEPTH. PROVIDE PLANT TABS, QUANTITY ACCORDING TO MANUFACTURER'S SPECIFICATIONS NOTES: 1. INSTALL GROUNDCOVER AS SPECIFIED 2. INSTALL FERTILIZERS PER MANUFACTURER'S RECOMMENDATIONS 3. SCORE ROOTBALL 3 PLACES TO %2" DEPTH 4. INSTALL 1" ABOVE CONTAINER DEPTH TOP DRESSING 2D FERTILIZER AS SPECIFIED TYPICAL FINISHED GRADE D W/ 2" LAYER SPECIFIED MULCH. VERIFY SAUCER 11`Illli►'!��i��►�rr�:`' �i1►1��llli�'!��iui►`��i►��aw `'�illl��lll GROUNDCOVER PLANTING SCALE: 1" = 1'-0" CURRENT PLANNING NAT Clark Close 06/02/2026 HENSLEY LAMKIN RACHEL, INC. DALLAS • HOUSTON • SEATTLE WWW.HLRINC.NET PH: 972.726.9400 PROJECT MGR: ILL DRAWN BY: ILL CHECKED BY: GB REVISIONS NOT FOR CONSTRUCTION a E 0 U ,2 N� Cn w CO CO Z NQ 2' Q N � a� N (i OF W A SN OFtY E. gR r � CJ 2OS S�6 EX P.1p11�\ PE ARG ©2020 HENSLEY LAMKIN RACHEL, INC. DOCUMENTS AS INSTRUMENTS OF SERVICE ARE GIVEN IN CONFIDENCE AND REMAIN THE PROPERTY OF HENSLEY LAMKIN RACHEL, INC. THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT WRITTEN CONSENT OF HENSLEY LAMKIN RACHEL, INC. roject Title: KENNYDALE GATEWAY 4350 LAKE WASHINGTON BLVD. N. RENTON, WA s VULCAN DD Issue: 03.23.22 Permit Issue: 12.07.22 Permit Resubmittal Issue: 04.20.26 1 Project ID Drawing No. PLANTING DETAILS L5.01