Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-427573
G C 1X k1 ���!�► ,IWAor _10 I 1\ IIIIIIIIIIoI 0 20 40 .0 feet NORTH IRRIGATION SCHEDULE �,11!�� I_IT 1� 11� ilk ill ilk rI I'll .. 0 SYMBOL MANUFACTURER/MODEL/DESCRIPTION SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER ICV-G HUNTER PROS-06-PRS30-CV SR SERIES 11N., 1-1/21N., 21N., AND 31N. PLASTIC © 0 o O o 4 SHRUB SPRAY, 30 PSI REGULATED 61N. 30 ELECTRIC REMOTE CONTROL VALVES, zQ zH 4Q 4H 6Q 6H POP-UP. WITH FACTORY INSTALLED DRAIN GLOBE CONFIGURATION, WITH NPT CHECK VALVE. CO -MOLDED WIPER SEAL THREADED INLET/OUTLET, FOR WITH UV RESISTANT MATERIAL. COMMERCIAL/MUNICIPAL USE. HUNTER PROS-06-PRS30-CV STRIP SERIES HUNTER HQ-44LRC-AW � � � � � SHRUB SPRAY, 30 PSI REGULATED 61N. 30 QUICK COUPLER VALVE, YELLOW RUBBER ES LCS RCS CS SS POP-UP. WITH FACTORY INSTALLED DRAIN 0 LOCKING COVER, RED BRASS AND CHECK VALVE. CO -MOLDED WIPER SEAL STAINLESS STEEL, WITH 11N. NPT INLET, WITH UV RESISTANT MATERIAL. 2-PIECE BODY. ACME KEY WITH HUNTER PROS-06-PRS30-CV STRIP SERIES ANTI -ROTATION WINGS. SHRUB SPRAY, 30 PSI REGULATED 61N. 30 LANDSCAPE PRODUCTS INC. BGV SST POP-UP. WITH FACTORY INSTALLED DRAIN 1 /21N., 3/41N., 11N., 1-1 /41N., 1-1/21N., CHECK VALVE. CO -MOLDED WIPER SEAL 21N., 2-1/21N., 31N., 41N. BRASS GATE WITH UV RESISTANT MATERIAL. VALVE. THREADED BONNET, NON -RISING HUNTER PROS-06-PRS30-CV 10 SERIES STEM, PRESSURE RATED TO 200 PSI. (4440 SHRUB SPRAY, 30 PSI REGULATED 61N. 30 SAME SIZE AS MAINLINE. Q T H F POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO -MOLDED WIPER SEAL HUNTER ICV-G 2" WITH UV RESISTANT MATERIAL. 11N., 1-1/21N., 21N., AND 31N. PLASTIC My ELECTRIC MASTER VALVE, GLOBE HUNTER PROS-06-PRS30-CV 12 SERIES CONFIGURATION, WITH NPT THREADED 1 C� �O SHRUB SPRAY, 30 PSI REGULATED 61N. 30 INLET/OUTLET, FOR Q T H F POP-UP. WITH FACTORY INSTALLED DRAIN COMMERCIAL/MUNICIPAL USE. CHECK VALVE. CO -MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. PRESSURE REDUCING VALVE HUNTER PROS-06-PRS30-CV 15 SERIES 1-1/2" WILKENS 600 SERIES PRESSURE 4440 4• SHRUB SPRAY, 30 PSI REGULATED 61N. 30 REDUCING VALVE. SET AT 75 PSI Q T H F POP-UP. WITH FACTORY INSTALLED DRAIN PRESSURE REQUIRED DOWNSTREAM IS CHECK VALVE. CO -MOLDED WIPER SEAL 80.5 PSI WITH UV RESISTANT MATERIAL. BF ZURN 950XLT 2" HUNTER PROS-06-PRS30-CV ADJ SERIES DOUBLE CHECK VALVE ASSEMBLY ® © ® to iz i5 1, SHRUB SPRAY, 30 PSI REGULATED 61N. 30 POP-UP. WITH FACTORY INSTALLED DRAIN HUNTER HC-150-FLOW CHECK VALVE. CO -MOLDED WIPER SEAL 1-1/21N. FOR USE WITH HYDRAWISE WITH UV RESISTANT MATERIAL. ENABLED CONTROLLER TO MONITOR FLOW FS AND PROVIDE SYSTEM ALERTS. ALSO HUNTER MP CORNER PROS-06-PRS40-CV FUNCTIONS AS STAND ALONE FLOW SHRUB ROTATOR, POP-UP WITH FACTORY TOTALIZER/SUB METER ON ANY O INSTALLED CHECK VALVE, PRESSURE 40 RESIDENTIAL OR COMMERCIAL IRRIGATION REGULATED TO 40 PSI, MP ROTATOR SYSTEM. NOZZLE. T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. SENSUS OMNI 1-1/2" HUNTER MP STRIP PROS-06-PRS40-CV SHRUB ROTATOR, 61N. POP-UP WITH IRRIGATION LATERAL LINE: PVC SCHEDULE FACTORY INSTALLED CHECK VALVE, 40 © 0 0 LST SST RST PRESSURE REGULATED TO 40 PSI, MP 40 ROTATOR NOZZLE. LST=IVORY LEFT STRIP, IRRIGATION MAINLINE: PVC SCHEDULE 40 SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP ON PRS40 BODY. - PIPE SLEEVE: DUCTILE IRON PIPE - ^ - ^ CLASS 52 HUNTER MP1000 PROS-06-PRS40-CV SHRUB ROTATOR, 61N. POP-UP WITH CHECK - - - - - - - - PIPE SLEEVE: PVC SCHEDULE 40 VALVE, PRESSURE REGULATED TO 40 PSI, 40 MP ROTATOR NOZZLE. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO Valve Callout 270 ARC, O=OLIVE 360 ARC ON PRS40 Valve Number BODY. $� t _ Valve Flow # Valve Size HUNTER MP2000 PROS-06-PRS40-CV SHRUB ROTATOR, 61N. POP-UP WITH c O o FACTORY INSTALLED CHECK VALVE, 40 IRRIGATION SYSTEM PRESSURE 40 PSIMP BACK ROTATOR NOZZ ELATED ADJ' ARC DESIGN INTENT: 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC ON PRS40 BODY. IRRIGATION SYSTEM HAS BEEN DESIGNED WITH THE INTENT HUNTER MP800SR PROS-06-PRS40-CV TO OPERATE MULTIPLE IRRIGATION ZONES AT A TIME. THE SHRUB ROTATOR, 61N. POP-UP WITH CHECK OVERALL SYSTEM IS DESIGNED TO RUN AT A MAXIMUM FLOW 0 ® VALVE, PRESSURE REGULATED TO 40 PSI, 40 50 GPM. IF OPERATOR SCHEDULES IRRIGATION CONTROLLER 8 $ F MP ROTATOR NOZZLE ON PRS40 BODY. TO IRRIGATE MORE THAN 50 GPM AT A TIME SYSTEM ADJ=ORANGE AND GRAY ( ARC 90-210), PRESSURE WILL DECREASE & CREATE OPERATING & 360=LIME GREEN AND GRAY (ARC 360) COVERAGE DEFICIENCIES. HUNTER MP815 PROS-06-PRS40-CV SHRUB ROTATOR, 61N. POP-UP WITH CHECK <8> 40 VALVE, PRESSURE REGULATED TO 40 PSI, 40 MP ROTATOR NOZZLE. M=MAROON AND GRAY ADJ ARC 90 TO 210, L=LIGHT BLUE AND GRAY 210 TO 270 ARC, O=OLIVE AND GRAY 360 ARC ON PRS40 BODY. lip „ter I�. i ii IRRIGATION NOTES: 1. PROVIDE AND INSTALL ALL IRRIGATION IN CONFORMANCE WITH THE CITY OF RENTON STANDARDS. IN THE EVENT OF CONFLICT BETWEEN NOTES OR DETAILS AND THESE DOCUMENTS, THE STANDARDS SHALL TAKE PRECEDENCE. 2. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND APPROPRIATE SAFETY REGULATIONS. 3. IRRIGATION DRAWINGS ARE SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO UTILITIES OR EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR LOCATING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 4. ALL IRRIGATION EQUIPMENT SHALL BE LOCATED WITHIN PROJECT PROPERTY LINES & WITHIN LANDSCAPE BEDS WITH THE EXCEPTION OF ITEMS IN THE RIGHT OF WAY. ITEMS SHOWN OFF PROPERTY OR IN HARDSCAPE ARE FOR CLARITY ONLY. 5. EXISTING SYSTEM PRESSURE IS 125 PSI. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EXISTING P.S.I. NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES BETWEEN THE DESIGN P.S.I. PRIOR TO PROCEEDING W/ WORK. 6. SEE IRRIGATION SCHEDULE FOR HEAD DESIGN PRESSURES. 7. LOCATE QUICK COUPLING VALVE & AUTOMATIC CONTROL VALVES AT POINT OF EASY ACCESS. OWNER'S REPRESENTATIVE TO REVIEW & APPROVE FINAL LOCATION OF ALL QUICK COUPLERS & AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 8. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY W/ EXISTING SITE CONDITIONS AND PLANT MATERIALS. ADJUST SPRAY PATTERN FOR MAXIMUM COVERAGE. 9. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & LOCATED ON DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE. 10. ALL IRRIGATION SLEEVES SHALL BE TWICE THE DIAMETER OF THE INSERT PIPE(S). SLEEVES SHALL NOT EXCEED 6" DIAMETER. 11. PVC MAINLINE LOCATIONS ARE SCHEMATIC. NO BENDING OF MAINLINE PIPE. 12. NO VALVE MANIFOLDS. GROUP VALVES TOGETHER W/ TEES 3' APART. VALVE BOXES SHALL OPEN THE SAME DIRECTION. 13. VALVE BOXES SHALL BE LEVEL & OPEN SAME DIRECTION. 14. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM. 15. PIPES TO SHARE TRENCHES WHERE POSSIBLE. SEPARATE COMMON PIPING BY 6" MIN. 16. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL BE SIZED TO THE NEXT LARGEST PIPE SIZE SHOWN UPSTREAM ON THE PLAN. 17. LETTERS ON PIPING SHALL BE ROTATED TO FACE UP. 18. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL CONDUIT TO CONTROLLER LOCATIONS & POINTS OF CONNECTION. 19. GENERAL CONTRACTOR TO PROVIDE POWER SOURCE FOR IRRIGATION CONTROLLER. (VERIFY LOCATION W/ OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK) 20. IRRIGATION CONTROLLER REQUIRES SECURE WIFI CONNECTION. 21. INSTALL FLOW SENSOR PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 22. LAY OUT MAINLINE AND LATERALS WITH 8' OF CLEARANCE FROM NEW TREES. 23. CONTRACTOR IS TO USE A BRANDING IRON TYPE OF TOOL TO IMPRINT VALVE BOX LIDS WITH NUMBERS. (CHARACTERS TO BE 2" IN HEIGHT). USE NUMBERING SYSTEM AS INDICATED ON PLANS. CURRENT PLANNING IIFO..,N Clark Close 06/02/2026 VALVE SCHEDULE NUMBER MODEL SIZE TYPE GPM DESIGN PSI FRICTION LOSS VALVE LOSS PSI PSI (aD- POC PRECIP 1 HUNTER ICV-G 1-1/2" SHRUB ROTARY 34.71 40 7.95 1.59 49.5 64.2 0.87 in/h 2 HUNTER ICV-G 1-1/2" SHRUB ROTARY 34.39 40 6.6 1.59 48.2 62.9 0.44 in/h 3 HUNTER ICV-G lot SHRUB ROTARY 17.11 40 6.9 3 49.9 64.6 0.88 in/h 4 HUNTER ICV-G 1-1/2" SHRUB ROTARY 24.11 40 2.76 1.5 44.3 60.8 0.47 in/h 5 HUNTER ICV-G 1-1/2" SHRUB ROTARY 26.06 40 4.58 1.5 46.1 62.6 0.51 in/h 6 HUNTER ICV-G lip SHRUB ROTARY 18.69 40 2.31 3 45.3 61.9 0.47 in h 7 HUNTER ICV-G 1 " SHRUB ROTARY 16.0 40 5.24 3 48.2 64.8 0.5 in h 8 HUNTER ICV-G lot SHRUB SPRAY 9.7 30 4.99 2.97 38.0 54.0 2.94 in/h 9 HUNTER ICV-G 1-1/2" SHRUB ROTARY 32.19 40 6.4 1.54 47.9 63.9 0.66 in/h 10 HUNTER ICV-G 1-1/2" SHRUB ROTARY 38.16 40 5.29 1.66 47.0 63.5 0.44 in/h 11 HUNTER ICV-G 1-1/2" SHRUB ROTARY 33.59 40 7.39 1.57 49.0 64.4 0.92 in/h 12 HUNTER ICV-G 1 it SHRUB ROTARY 17.16 40 7.03 3 50.0 65.4 0.51 in/h 13 HUNTER ICV-G lot SHRUB ROTARY 20.43 40 4.34 3.26 47.6 69.4 0.98 in/h 14 HUNTER ICV-G 1-1/2" SHRUB ROTARY 47.94 40 7.66 2.1 49.8 71.5 0.49 in/h 15 HUNTER ICV-G lip SHRUB ROTARY 19.12 40 5.34 3 48.3 68.1 0.88 in/h 16 HUNTER ICV-G 1-1/2" SHRUB ROTARY 38.21 40 5.62 1.66 47.3 67.2 0.78 in/h 17 HUNTER ICV-G 1-1/2" SHRUB ROTARY 22.48 40 7.95 1.5 49.4 69.3 0.47 in/h 18 HUNTER ICV-G 1-1/2" SHRUB ROTARY 41.84 40 5.8 1.79 47.6 56.6 0.42 in/h ■ HENSLEY LAMKIN RACHEL, INC. DALLAS • HOUSTON • SEATTLE WWW.HLRINC.NET PH: 972.726.9400 PROJECT MGR: LL DRAWN BY: LZ CHECKED BY: JA REVISIONS NOT FOR CONSTRUCTION a 0 0 = 0_ o W CO Co Z Na Q co C\1 C/)o - C0 QQ co 0 rCD CV CD �U) Of WAS A No P � M . z r ►- o oti v ti 2OSC36 EXP.O8�2G�j.�� q PE AR ©2020 HENSLEY LAMKIN RACHEL, INC. DOCUMENTS AS INSTRUMENTS OF SERVICE ARE GIVEN IN CONFIDENCE AND REMAIN THE PROPERTY OF HENSLEY LAMKIN RACHEL, INC. THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT WRITTENM CONSENT OF HENSLEY LAKIN RACHEL, INC. Project Title: KENNYDALE GATEWAY 4350 LAKE WASHINGTON BLVD. N. RENTON, WA .011111110 go VULCAN rI. DID Issue: 03.23.22 IPermit Issue: 12.07.22 Permit Resubmittal Issue: 12.22.23 Project ID Drawing No. IRRIGATION PLAN L5.02