B ELEVATIONS
1 " = 10'-0"
FINISHED GRADE 9" TO 12"
o
a
24" TO 30"
221/2° i
MAIN
LOOP DOWN TO CENTERLINE OF WATER MAIN
TO PROVIDE SLACK IN SERVICE LINE TO METER
MATERIALS
Z
r /- IN UNIMPROVED ROW,
it w INSTALL METER BOX
n AT PROPERTY LINE WITH
1" COPPER TAILPIECE
SIDEWALK
w CITY PRIVATE
a-
O
a PIPING PIPING
d 12"
21" TO 30"
1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET,
OA
CORPORATION STOP
FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ
OB
TUBING
1" TYPE "K" SOFT COPPER TUBING
1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK
OC
METER SETTER
VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER
B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS
OD
WATER METER
AM] WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY
O
METER BOX
METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ
"RENTON WATER"
O
COUPLER AND PLUG
COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO
PROPERTY IS TO BE INSTALLED IN THE FUTURE
OG
GRAVEL
11/4" WASHED GRAVEL
•;� PUBLIC WORKS
DEPARTMENT
1" WATER SERVICE
STD. PLAN - 320.1
APPROVED:6/28/202'
Martin Pastucha DATE
Public Works Administrator
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
2Q 2p,
S
5
2", 4", 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
�0,,6
#3 BAR EACH CORNER
#3 BAR EACH SIDE
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
URIPUBLIC WORKS
DEPARTMENT
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
CONCRETE
12"
ALL METAL PIPE
15"
CPSSP',
STD. SPEC. 9-05.20
12"
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9-05.12(2)
15"
' CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN,
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
111:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (r
STD. PLAN - 200.00
CATCH BASIN TYPE 1
GAZ
i
9/28/2018
DATE
6 1/2"--
5 1/2` y 1"
r
FACE OF CURB
TOP OF
ROADWAY
r
1' 6"
CEMENT CONCRETE
TRAFFIC CURB AND GUTTER
FACE OF ADJACENT CURB
6 112`
- FLUSH WITH GUTTER
PAN AT SIDEWALK
RAMP ENTRANCE
1.12 1:24
TOP OF
1/2" R. ROADWAY
ico
DEPRESSED CURB SECTION
AT SIDEWALK RAMPS
318"
PREMOLDED
JOINT FILLER
E FULL -DEPTH
EXPANSION JOINT
6" CEMENT CONCRETE
112" R. 1"R. SIDEWALK RAMP
VARIES
OR LANDING
� i
FROM
6"TOO
r
3/8" PREMOLDED
JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
AT SIDEWALK RAMPS AND LANDINGS
FACE OF ADJACENT CURB
6 1/2"
SEE DEPRESSED CURB DETAIL THIS SHEET
1:24
TOP OF
1/2' R. ROADWAY
2"
Y
f
I
DEPRESSED CURB SECTION
AT RESIDENTIAL DRIVEWAYS ONLY.
FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2
FACE OF ADJACENT CURB
GUTTER SURFACE
FACE OF CURB
6 1/2"
5 1/2" _ 1"
112" R. ' 1" R.
TOP OF
cO ROADWAY
r
8114"
CEMENT CONCRETE
TRAFFIC CURB
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101 A for curb expansion and contraction joint spacing.
2. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler.
3. For Depressed Monolithic Driveway Curb 8 Gutter Section, see Standard Plan 104.2
STD. PLAN - 101
• PUBLIC WORKS CEMENT CONCRETE CURBS 411p;
DEPARTMENT
DEVELOPMENT ENGINEERING
H H uyn h 01 /23/2025
P A R K W E S T ❑ E S I G N
O
U)
U)
LU
_J
c�
Q
OU)
LO
�
w
oCY)
o
M
>
�
LL
Q
LU
z
z
Z
C�
<
Z
>_
UJ
0�
UJ
o
CD
Z
0
Revision Revision Description Revision
Number Date
(Client-
Revision Schedule
1302 N 30TH ST
RENTON WA 98056
Drawn By: Sheet
Date:
F2
Scale:
1 " = 1 0'-0"
R-432803