Loading...
HomeMy WebLinkAboutR-432804DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 EO REIY 651 WA"RAWSi vAIIKS 15EE NOTE 71 PB NOR E1 iEE TOR ti I so LF OF PAV_w ORNE WAY 11 _ rCNHN11'ExPAINS" [SEE araOuNw lati %1 y J RAl?w"Um1Y I $LOPE (TW i - :1FFEREk[f $4 SLOW IJAx - L»L JL NAY OV MATTVE .EGA-,Wt SLOPE ($LOPE -- SHOWN ExAGGEMTEC. 5" NOTE MOW . - CONSTRUCTION Jaw -t--- an ITOTE I - i U ENR CONGETE 18' CCNTRACT4N JOT4T (f" ; i IEEE S70 PUN Na21 . PLAY VIEW IIAOU -NO - a.)% 11M11 i SEE NOTE a ITYP} r aNw L r NIN CEUENT CONCIETE °• hw `. SAP EXPANSION JOW MO.) [lPNESSEO CL 6 a GUT" ISISS TOTE II S6!*Atx SECTION OA - (WE STD PUN IOa �-_ N7IL R1i►J alOHti►xYMJM_ i - - OaP/i1MT Mk rNF S: (PE IS 0"SH;YhN ExwzIRATEO) _ T s* _ ',• +- �_:� fMOvlWAV -- r w _ I coNcGh"te EREVWtK CELENT CONCRETE CNN $ ouTTER SEE NOTE 7, TES sae S'U PiA%)UJ- 1 i o� STD. PLAN — 104.1 + PUBLIC WORKS CEMENT CONCRETE DRIVEWAY MITT ED �- ? DEPARTMENT ENTRANCE - TYPE R1 Z� FN O w z Ld w 3 0 c� z V) !n X w 00-A " TAPPING TEE (MJxFL) TAPPING GATE VALVE (FL XMJ) TEMPORARY PLUG (MJ) WITH 2-INCH TAP AND 2-INCH BLOW -OFF ASSEMBLY CONCRETE BLOCKING TESTING DETAIL w Z w 3 IEW D.I. WATER LINE VERTICAL CROSS(MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) WITH 2"TAP & 2" BLOW -OFF TEMPORARY BLOCK FINAL CONNECTION DETAIL ' O NEW D.I. WATER LINE (AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTION BY CITY FORCES NOTES: 1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY -COATED STEEL. BOLTS AND NUTS SHAL BE COR-TEN. ALL TEES AND VALVES SHALL BE WATER TESTED BEFORE TAP 2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. 3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4. WET -TAPPING OF EXISTING CITY OF RENTON WATER MAINS WILL BE DONE BY SPEER TAP OR SUPERIOR TAPPING INC. 5. CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF EXISTING LINE OR STUB AND SHALL START LAYING THE NEW LINE AT THE SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE EXISTING STUB. 6. CITY FORCES WILL PERFORM THE FINAL CONNECTION FROM THE WATER LINE TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL. uti�Y C CONNECTION TO WATER MAIN WITH STD. PLAN — 300.1 es + PUBLIC WORKS � LIN DEPARTMENT TAPPING TEE & VALVE MARCH 2O10 -r---------- f� EX. SEWER MAW I I I I l PROPERTY LINE SPOOL I I I z I I 1 I 1 (LENGTH AS NEEDED) i i i - I 3'-O" MIN O 6" SEWER STUB !s'tif' FUTURE 4" SIDE SEWER I I 1 I I I 1 I I I 1 SEWER MAIN TEE X 6" TEE SIDEWALK I I I I I J COUPLING (TYP ) JI -LI ----------) Q r>J > 13 1 L 0 II I� ' I � rT--------- 'i: '` -----------------------r-_j r L --- J BEND AS �` g" REQUIRED �G`C--� \-------- f2"x 4" STUD MARKING POST PAINTED 6" CAP J WHITE WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WARE WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH EXISTING SANITARY _ SEWER MAIN r2 Dy" MIN SLOPE t`FUTURE a" SIDE SEWER \\-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) 0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES• 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT 6ACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN -406.1 �� PUBLIC WORKS APP "�'%NDEPARTMENT INSTALLATION Martin PastuCKW26/202 (SEWER MAIN TO PROPERTY LINE) , . ,. , �, „ „ ,. DATE 1 12: "It P A R K W E S T ❑ E S I G N v / J U Uj LO W 0 O r n� v / MO W 00) 0� Z> N > p z LU M z z Q 0CoO U) QIV— 0z W �n W V Q O Z > 0 0. LL Revision Revision Description Revision Number Date Revision Schedule Client: 1302 N 30TH ST RENTON WA 98056 Drawn By: Sheet Date: F 3 Scale: R-432804