HomeMy WebLinkAboutR-432804DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
EO REIY 651 WA"RAWSi
vAIIKS 15EE NOTE 71
PB NOR E1
iEE TOR ti
I
so LF OF PAV_w
ORNE WAY 11
_
rCNHN11'ExPAINS"
[SEE araOuNw
lati %1
y
J
RAl?w"Um1Y I
$LOPE (TW i -
:1FFEREk[f $4 SLOW IJAx -
L»L JL NAY OV MATTVE
.EGA-,Wt SLOPE ($LOPE --
SHOWN ExAGGEMTEC.
5" NOTE
MOW
.
- CONSTRUCTION Jaw -t---
an ITOTE I -
i
U ENR CONGETE
18' CCNTRACT4N JOT4T (f" ; i
IEEE S70 PUN Na21 .
PLAY VIEW
IIAOU
-NO
- a.)% 11M11
i
SEE NOTE a ITYP}
r aNw
L r NIN
CEUENT CONCIETE
°• hw
`. SAP EXPANSION JOW MO.)
[lPNESSEO CL 6 a GUT"
ISISS TOTE II
S6!*Atx
SECTION OA
- (WE STD PUN IOa
�-_
N7IL R1i►J
alOHti►xYMJM_
i - - OaP/i1MT Mk rNF
S: (PE IS 0"SH;YhN ExwzIRATEO) _
T s* _
',•
+-
�_:�
fMOvlWAV
--
r w
_ I
coNcGh"te
EREVWtK
CELENT CONCRETE
CNN $ ouTTER
SEE NOTE 7,
TES sae S'U PiA%)UJ-
1 i o� STD. PLAN — 104.1
+ PUBLIC WORKS CEMENT CONCRETE DRIVEWAY MITT ED
�- ? DEPARTMENT ENTRANCE - TYPE R1 Z�
FN O
w
z
Ld
w
3
0
c�
z
V)
!n
X
w
00-A "
TAPPING TEE (MJxFL)
TAPPING GATE VALVE (FL XMJ)
TEMPORARY PLUG (MJ) WITH 2-INCH TAP
AND 2-INCH BLOW -OFF ASSEMBLY
CONCRETE BLOCKING
TESTING DETAIL
w
Z
w
3
IEW D.I. WATER LINE
VERTICAL CROSS(MJxFL) FOR POLYPIGGING
1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG
1-BLIND FLANGE ON BOTTOM
1-PLUG(MJ) WITH 2"TAP & 2" BLOW -OFF
TEMPORARY BLOCK
FINAL CONNECTION DETAIL
' O NEW D.I. WATER LINE
(AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING
AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF
AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS
FINAL CONNECTION BY CITY FORCES
NOTES:
1. TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR
EPDXY -COATED STEEL. BOLTS AND NUTS SHAL BE COR-TEN. ALL TEES
AND VALVES SHALL BE WATER TESTED BEFORE TAP
2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. TAP SHALL BE AT
LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN.
3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE
4. WET -TAPPING OF EXISTING CITY OF RENTON WATER MAINS WILL BE DONE BY
SPEER TAP OR SUPERIOR TAPPING INC.
5. CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL
ALIGNMENT OF EXISTING LINE OR STUB AND SHALL START LAYING THE NEW
LINE AT THE SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE EXISTING
STUB.
6. CITY FORCES WILL PERFORM THE FINAL CONNECTION FROM THE WATER LINE
TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL.
uti�Y C CONNECTION TO WATER MAIN WITH STD. PLAN — 300.1
es + PUBLIC WORKS
� LIN DEPARTMENT TAPPING TEE & VALVE MARCH 2O10
-r----------
f� EX. SEWER MAW
I I I I
l PROPERTY LINE
SPOOL I I I z I
I 1 I 1
(LENGTH AS NEEDED) i i i - I 3'-O" MIN
O
6" SEWER STUB !s'tif' FUTURE 4" SIDE SEWER
I I 1
I I I 1
I I I 1
SEWER MAIN TEE X 6" TEE
SIDEWALK
I I I I I J
COUPLING (TYP ) JI -LI ----------) Q
r>J >
13 1
L
0
II
I�
' I
�
rT--------- 'i: '`
-----------------------r-_j
r
L --- J
BEND AS �`
g"
REQUIRED
�G`C--�
\--------
f2"x 4" STUD MARKING POST PAINTED
6" CAP J WHITE WITH THE WORD "SEWER" STENCILED
IN 3" HIGH BLACK LETTERS AND #6 WARE
WRAPPED AROUND THE STUD AND
EXTENDED TO THE TOP OF THE STUD
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8" IN DEPTH
EXISTING SANITARY _
SEWER MAIN r2 Dy" MIN SLOPE
t`FUTURE a" SIDE SEWER
\\-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER
`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
NOTES•
1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT 6ACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB STD. PLAN -406.1
�� PUBLIC WORKS APP
"�'%NDEPARTMENT INSTALLATION Martin PastuCKW26/202
(SEWER MAIN TO PROPERTY LINE) ,
. ,. , �, „ „ ,. DATE
1 12:
"It
P A R
K W
E S T ❑ E
S I G N
v /
J
U
Uj
LO
W
0
O
r n�
v /
MO
W
00)
0�
Z>
N
>
p
z
LU
M
z
z
Q
0CoO
U)
QIV—
0z
W
�n
W
V
Q
O
Z
>
0
0.
LL
Revision
Revision Description
Revision
Number
Date
Revision
Schedule
Client:
1302 N 30TH ST
RENTON WA 98056
Drawn By: Sheet
Date: F 3
Scale:
R-432804