HomeMy WebLinkAboutR-43280613"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, NC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE RON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS, INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 9" MIN 12" MAX FINISH GRADE 11 gIw 36" MIN! COVER,, - o N o L) _ -W DUCTILE IRON WATERMAIN CITY PRIVATE PIPING PIPING z I IN UNIMPROVED RIGHT OF � z I J WAY INSTALL METER BOX AT PROPERTY LINE WITH 12" w' LONG COPPER TAILPIECE. w SIDEWALK aI a I I TOUCHREAD WATER METER TO BE 12 SUPPLIED BY THE z a CITY TYPE "K" SOFT ` > o / COPPER TUBING 17 IF SERVICE LINE TO HOUSE IS TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR 44 FIPT x COMPRESSION COUPLING � LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8"x3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WC0033, OR MUELLER: 3/4-8-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2 (3/4" F61000-3-Q) OR AY MCDONALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" FB1000-4-0) OR AY MCDONALO 4701B INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. A- A DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID TYPICAL RIB 3/4" OR 1" GALVANIZED PLUG NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. 34" AND 1" WATER SERVICE STD. PLAN - 320.1 L 3 M 0 ¢ 0 INSIDE HOUSE PREFERRED CONFIGURATION 5 �2 3 10 8 10 4 2 FLOW # ITEM AMT 1 90• GALVANIZED STEEL ELBOW 4 EA. 2 3/4" PACKING JOINT COUPLING W/MALE IRON PIPE 2 EA. THREAD FOR COPPER PIPE SERVICE: FORD C84-33 OR EQUIVALENT FOR GALVANIZED PIPE SERVICE:FORD C85-33 OR EQUIVALENT 3 PRESSURE REDUCING VALVE W/STRAINER - 3/4" 1 EA. WITH UNION COUPLINGS AT INLET AND OUTLET, WILKINS 600 SERIES OR EQUAL (WITH INTERNAL BYPASS AND STRAINER) 4 3/4" CLOSE UNION - BRASS (M X F) 1 EA. 5 3/4" BRASS VALVE VARIABLE 6 12" STANDARD METER BOX W/SOLID COVER 1 EA. CONCRETE: 17 1/4 X 28 5/8 INSIDE DIMENSIONS, EQUAL TO FOG TITS METER SEAL CO. +2 PLASTIC: 13 X 24 j INSIDE DIMENSIONS, EQUAL TO BROOKS METER BOX 7 3/4" GALVANIZED STEEL PIPE. THREADED. LENGTH AS VARIABLE REQUIRED 8 3/4- X 1/4" X 3/4" STD. BRASS TEE 1 EA. 9 1/4" PETCOCK (M X F) 1 EA. 10 3/4" BRASS NIPPLE VARIABLE PROPERTY 7 ADJACENT TO WATER METER LINE 5 6 9 5 SAWDUST FILL 7 7FROM JMIN P ATYp L WATERMETER 3 10 B 10 4 2 O FLOW FUNCTION THE FUNCTION OF A PRESSURE REDUCING VALVE IS TO REDUCE HIGH-WATER PRESSURES IN THE SERVCE CONNECTION TO AN ACCEPTABLE RANGE OF 55 TO 75 PSI INSTALLATION OF A PRESSURE REDUCING VALVE IS REQUIRED WHERE THE SERVICE CONNECTION PRESSURE EXCEEDS 80 POUNDS PER SQUARE INCH IN ACCORDANCE TO THE UNIFORM PLUMBING CODE. INSTALLATION THE PRESSURE REDUCING VALVE SHALL BE LOCATED ON THE CUSTOMER'S PROPERTY "DOWNSTREAM" OF THE METER BOX. RESPONSIBILITY FOR PROPER INSTALLATION, OPERATION, AND MAINTENANCE OF THE VALVE SHALL BE ASSUMED BY THE CUSTOMER, THREE POSSIBLE CONFIGURATIONS FOR INSTALLATION OF THE VALVE ARE SHOWN ABOVE. A BUILDING DEPARTMENT PLUMBING PERMIT IS REQUIRED PRIOR TO INSTALLATION ,-� 34" & 1" INDIVIDUAL PRESSURE REDUCING STD. PLAN - 340.5 0 VALVE ASSEMBLY DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET, ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY. THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY. STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING. AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5, A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS, 7, VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK. DATUM. AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14w - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS. ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION, WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10. AND 220.20. 13, STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1. 2. OR 5 INSIDE AND OUTSIDE. 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.1D. 204.20, 204,30. AND 204.50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. • ROUND. SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16, LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLEICATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESSOTHERWISE NOTED, DRAWING ISNOTTO SCALE (NTS) STD. PLAN - 267.00 UR)PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR D: DEPARTMENT NOTES (1 OF 2) GAZ 9/28/2018 1 o"ee, won. nem ",,,,,.o, DATE REVISION UoCuz5ign tnvelope BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) ---\ FOUNDATION LEVEL LIMITS OF PIPE ZONE V-10" O.D. OF PIPE 6" BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 URIPUBLIC WORKS PIPE BEDDING rrs � EI DEPARTMENT FOR SANITARY SEWERS GAZ 9/11/2019 1 DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT, THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT. MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT, HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18, ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOI AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4 - 81NCH ROCK 140 - 70% PASSING; • 2 - 4 INCH ROCK 130 - 40% PASSING; AND • LESS THAN 2 INCH ROCK 110 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM' SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266-00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS. GUTTERS AND/OR PAVEMENT, 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7.04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANDIOR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS. AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC. AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT N6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3.050). 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS. CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES. BIKE LANES, SIDEWALKS. AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29, CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2-1.A2 OF THE RENTON SWDM. 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE. THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G.. PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST, PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERW ISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.10 o PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR D: DEPARTMENT NOTES (2 OF 2) GAZ 9/28/2018 I 1 e, won. nem„e..o, DATE ocuSion Envelope ID: 7CDD88BC-C843439E-9366-C6DBBOF8BB87 :12 Ph :4S Ar rya r--i-r---------- _� EX. SEWER MAIN l PROPERTY LINE POOLLENGTH AS NEEDED) 3'-0" MIN. 6" SEWER STUB FUTURE 4" SIDE SEWER J�SEWER __________2"x 4" STUD MARKING POST PAINTED 6" CAP WHITEWITH THE WORD "SEWER" STENCILED MAIN TEE X 6" TEE IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK WRAPPED AROUND THE STUD AND � 1 I II EXTENDED TO THE TOP OF THE STUD. I COUPLING (TYP.) >j L_JI_L_-_______. : Q 3 LL 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER 1 (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD. I CONCRETE PAD TO BE 8" IN DEPTH. ------------------------ T-------- L---J BEND AS g" REQUIRED EXISTING SANITARY / SEWER MAIN -2 0% MIN. SLOPE \\ `\ ` FUTURE 4" SIDE SEWER �6" SEWER STUB L6"X6"XV WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL), 8. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -GRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC.); CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F. HDPE - CORE -DRILLED WITH A ROMAC SADDLE. "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER. G. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. OVA 3000 PSI MIX />«� CONCRETE BLOCKING 7 4 15 /�A� e�oGK�N ,pI,�N CO _ C_ 2% MIN SLOPE HORIZONTAL 6" TEE 6" MIN. SEWER MAIN SEWER MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN BETWEEN 25' AND 45• TYPICAL SIDE SEWER NQTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5- LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. SIDE SEWER STUB STD. PLAN -406.1 PUBLIC WORKS APPR VEf� INSTALLATION DEPARTMENT GAZ 9/11/2019 I VfttV (SEWER MAIN TO PROPERTY LINE) DATE CITY OF RENTON P, _'I nrling/B ji d r1y/r`UUh(_, Aur, _ Dept. E E PPS " Is I P A R K W E 5 T D E S I G N I W ILI U) J Uj � � w Lo o 0 0 Oo� Q �M� Z LU z z � :12 c't) 0 QoZ w 0 Z i LL Color Codes The utilities will be identified by painted rnarks or flags within twenty-four inches on either $Ile Revision Revision Description Revision of the utility line. Number Date RED Electric Revision Schedule YELLOW U Gas, CA, Fuel ORANGE j Cable. TV. Talephone BLUE pmliinij vVatar 1 . GREEN R-413002 W-413004 IN COMPLIANCE WITH CITY OF FZcv I viv z-3 I HNDARDS JUNG RESIDENCE 1008 N 28TH PL RENTON, WA 98056 TYPICAL STANDARD DETAILS FI 6/ 1 /2022 LiL_Dec PAcc DRAWING C3 3 3 Client: 1302 N 30TH ST RENTON WA 98056 Drawn By: Sheet Date: F 5 Scale: R-432801