HomeMy WebLinkAboutCD-4388GP GP
SD
SD SS
PC
SS
GP
GPGP
GP
GP
GPGP
IRR
SS
IRR IRR
SS GP
GP
P
IRR
GP
GP
IRR
HVACHVAC GP
G
PGP
GP
SD SD
GP
GP
CO
GP
CO
GP
P
CO
GP
GP
GP
GP
HVACHVAC
P
GP
GP
GP
SS
\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\
\
\\\
TOP
TO
P
TO
P
TOP
TO
P
TO
P
TOE
TO
E
T
O
E
TO
E
TO
E
\
\
\
\
\
\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\
\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\\\
W
FO
FO
FO
FOW
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
\\\
GP
GP
PIRRIRRIRR
C C
C
TO
E
TOP
W
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH S
T
INTERSTATE 405
N1
°
2
2
'
4
6
"
E
33
0
.
0
8
'
N77° 27' 4
4
"
E
117.47'
S1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77° 26' 1
0
"
E
119.92'
N1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
N77° 27' 4
4
"
E
29.98'
N77° 27' 4
4
"
E
63.89'
S9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
S77° 26' 10
"
W
84.61'
N1
°
2
2
'
4
3
"
E
10
8
.
1
2
'
S1
°
2
2
'
4
3
"
W
10
8
.
1
2
'
S8
°
5
7
'
1
5
"
E
6
0
.
1
2
'
N77° 24' 3
8
"
E
123.29'
S1
°
2
1
'
0
3
"
W
11
4
.
3
4
'
S86° 20' 10"W
391.52'
BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
BLDG
ADDITION
BASIS OF BEARINGS INITIAL POINT
CITY OF RENTON CONTROL POINT ID 1895
HELD PUBLISHED NAD 83/91 WASHINGTON STATE PLANE
NORTH ZONE COORDINATES
HELD A COMBINED GRID SCALE FACTOR OF
0.999987504615 (GRID TO GROUND) AT THIS POSITION
FND. ENCASED 1 7/8" BRASS DISK WITH PUNCH, DOWN 0.4'
VISITED 11/01/2024
PROJECT PRIMARY BENCHMARK
HELD PUBLISHED CITY OF RENTON ELEVATION:
25.702 FEET NAVD 88
BASIS OF BEARINGS SECONDARY POINT
CITY OF RENTON CONTROL POINT ID 1891
HELD PUBLISHED NAD 83/91 WASHINGTON
STATE PLANE NORTH ZONE COORDINATES
FOR ROTATION ONTO DERIVED GRID BEARING
FND. ENCASED 3" BRASS DISK STAMPED "CITY
OF RENTON BENCHMARK". MONUMENT IS
LOCATED ON TOP OF THE NORTHERLY CONC.
WALL OF BRIDGE OF SW 16TH ST. THAT
CROSSES SPRINGBROOK CREEK
VISITED 11/01/2024
PROJECT SECONDARY BENCHMARK
HELD PUBLISHED CITY OF RENTON
ELEVATION:
24.1568 FEET NAVD 88
OBSERVED ELEVATION:
24.06 FEET NAVD 88
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 40 80
1" = 40 FEET
20
1COVER SHEET
C0.0Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
C
O
V
R
.
d
w
g
NOT TO SCALE
VICINITY MAP
HHJ ARCHITECTS, LLC
601 ST HELENS AVE
TACOMA, WA 98402
PH. (253) 922-4168
CONTACT: JOHN MANUEL
ARCHITECT
OWNER
D&C INVESTMENT, LLC
PO BOX 1657
TACOMA, WA 98401
CELL: (206) 391-0311
CONTACT: DALE WALKER
CIVIL ENGINEER MCINNIS ENGINEERING
202 EAST 34TH STREET
TACOMA, WA 98404
PH. (253) 414-1992
CONTACT: LARRY WALKER, PLS
SURVEYOR
AHBL ENGINEERS, PLANNERS, &
SURVEYORS
2215 NORTH 30TH STREET,
SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
CONTACT: MATT WEBER, PE
3340404265.
SITE ADDRESS
519 SW 12TH ST
RENTON, WA 98057
PARCEL NUMBER
CITY OF RENTON
CITY OF RENTON
PUGET SOUND ENERGY
PUGET SOUND ENERGY
RENTON FIRE
UTILITIES/SERVICES
WATER:
SEWER:
POWER:
GAS:
FIRE:
UTILITY NOTE
TRENCH NOTE
FILL SPECIFICATION
IF WORKERS ENTER ANY TRENCH
OR OTHER EXCAVATION FOUR
OR MORE FEET IN DEPTH THAT
DOES NOT MEET THE OPEN PIT
REQUIREMENTS OF WSDOT
SECTION 2-09.3(3)B, IT SHALL BE
SHORED AND CRIBBED. THE
CONTRACTOR ALONE SHALL BE
RESPONSIBLE FOR WORKER
SAFETY AND AHBL ASSUMES NO
RESPONSIBILITY. ALL TRENCH
SAFETY SYSTEMS SHALL MEET
THE REQUIREMENTS OF THE
WASHINGTON INDUSTRIAL
SAFETY AND HEALTH ACT,
CHAPTER 49.17 RCW.
THE LOCATIONS OF EXISTING UNDERGROUND
UTILITIES ARE APPROXIMATE ONLY AND HAVE
NOT BEEN INDEPENDENTLY VERIFIED BY THE
OWNER OR ITS REPRESENTATIVE. THE
CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES BEFORE
COMMENCING WORK AND AGREES TO BE FULLY
RESPONSIBLE FOR ANY AND ALL DAMAGES THAT
HAPPEN DUE TO THE CONTRACTOR'S FAILURE
TO LOCATE EXACTLY AND PRESERVE ANY AND
ALL UNDERGROUND UTILITIES. AHBL ASSUMES
NO LIABILITY FOR THE LOCATION OF
UNDERGROUND UTILITIES.
IMPORTED FILL MATERIAL SHALL NOT CONTAIN
PETROLEUM PRODUCTS, OR SUBSTANCES
WHICH ARE HAZARDOUS, DANGEROUS, TOXIC,
OR WHICH OTHERWISE VIOLATE ANY STATE,
FEDERAL, OR LOCAL LAW, ORDINANCE, CODE,
REGULATION, RULE, ORDER, OR STANDARD.
TOPOGRAPHIC NOTE
THE EXISTING CULTURAL AND TOPOGRAPHIC
DATA SHOWN ON THESE DRAWINGS HAS BEEN
PREPARED, IN PART, BASED UPON INFORMATION
FURNISHED BY OTHERS. WHILE THIS
INFORMATION IS BELIEVED TO BE RELIABLE,
AHBL CANNOT ENSURE ACCURACY AND THUS IS
NOT RESPONSIBLE FOR THE ACCURACY OF
THAT INFORMATION OR FOR ANY ERRORS OR
OMISSIONS WHICH MAY HAVE BEEN
INCORPORATED INTO THESE DRAWINGS AS A
RESULT.
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE,
GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE
INTERSECTION OF LIND AVE. SW AND SW 16TH ST., BEING CITY OF
RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK, BEING CITY OF RENTON CONTROL ID. 1891,
RESPECTIVELY.
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY
THE CITY OF RENTON PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND)
WAS HELD AT CITY OF RENTON CONTROL ID. 1895
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
BASIS OF BEARING
HORIZONTAL DATUM
VERTICAL DATUM
PROJECT PRIMARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1895
PUBLISHED ELEVATION: 25.702' NAVD 88
DESCRIPTION:
ENCASED 3" BRASS DISK W/PUNCH
LOCATED AT THE INTERSECTION OF LIND
AVE. SW AND SW 16TH ST.
PROJECT SECONDARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1891
PUBLISHED ELEVATION: 24.1568' NAVD 88
OBSERVED ELEVATION: 24.06' NAVD 88
DESCRIPTION:
MONUMENT FOUND ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A
BRIDGE CROSSING OF SPRINGBROOK
CREEK.
SITE BENCHMARK
OBSERVED ELEVATION: 27.41' NAVD 88
DESCRIPTION:
ENCASED 1 7/8" BRASS DISK W/PUNCH AT THE INTERSECTION OF SW GRADY WAY AND SENECA AVE. SW
SITE BENCHMARK
LEGAL DESCRIPTIONS
SOUTHW
E
S
T
G
R
A
D
Y
W
A
Y
INTERSTATE 405
LI
N
D
A
V
E
S
W
MA
P
L
E
A
V
E
S
W
SW 12TH
S
T
SW 10TH
S
T
SW 16TH ST
E V
A
L
L
E
Y
RD
LI
N
D
A
V
E
S
W
SOUTHWE
S
T
G
R
A
D
Y
W
A
Y
SW 12TH S
T
SE
N
E
C
A
A
V
E
S
W
SW 13TH
S
T
SITE
Sheet List Table
Sheet Sheet
No.Sheet Title
1 C0.0 COVER SHEET
2 SV-01 LEGAL DESCRIPTIONS AND NOTES
3 SV-02 BLOCK CALCULATIONS DIAGRAM
4 SV-03 BOUNDARY SURVEY
5 SV-04 BOUNDARY SURVEY
6 SV-05 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
7 SV-06 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
8 SV-07 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
9 SV-08 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
10 SV-09 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
11 SV-10 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
12 SV-11 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
13 SV-12 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
14 SV-13 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
15 C1.1 SITE DEMOLITION PLAN
16 C1.2 TEMPORARY EROSION AND SEDIMENT CONTROL PLAN
17 C1.3 TESC NOTES AND DETAILS
18 C1.4 TESC NOTES AND DETAILS CONT.
19 C2.1 SITE PLAN AND HORIZONTAL CONTROL
20 C2.2 SURFACING DETAILS
21 C3.1 GRADING PLAN
22 C3.2 SITE CROSS SECTIONS
23 C3.3 STORM PLAN
24 C3.4 STORM RUN PROFILES
25 C3.5 STORM SYSTEM NOTES AND DETAILS
26 C3.6 STORM SYSTEM NOTES AND DETAILS
27 C3.7 CITY OF RENTON STANDARD STORM NOTES
28 C4.1 SEWER PLAN AND PROFILE
29 C4.2 EXISTING SEWER PLAN AND PROFILE
30 C4.3 SEWER NOTES AND DETAILS
31 C4.4 SEWER NOTES AND DETAILS
32 C4.5 SEWER NOTES AND DETAILS
33 C4.6 SEWER NOTES AND DETAILS
34 C5.1 WATER PLAN
35 C5.2 FIRE SYSTEM PLAN
36 C5.3 WATER NOTES AND DETAILS
37 C5.4 WATER NOTES AND DETAILS
38 C5.5 WATER NOTES AND DETAILS
39 C6.1 COMPOSITE UTILITY PLAN
40 L1 LANDSCAPE PLAN
41 L2 LANDSCAPE DETAILS AND NOTES
42 L3 IRRIGATION PLAN
43 CR1.1 SENECA AVE SW FRONTAGE IMPROVEMENTS
44 CR1.2 SW 12TH ST FRONTAGE IMPROVEMENTS
45 CR1.3 FRONTAGE DRIVEWAYS ENLARGEMENTS
46 CR1.4 SW 12TH ST PLAN AND PROFILE
47 CR1.5 CITY OF RENTON FRONTAGE IMPROVEMENT DETAILS
48 CR1.6 CITY OF RENTON FRONTAGE IMPROVEMENT DETAILS
49 CR1.7 CITY OF RENTON FRONTAGE IMPROVEMENT DETAILS
50 CR1.8 CITY OF RENTON FRONTAGE IMPROVEMENT DETAILS
51 CR1.9 CITY OF RENTON FRONTAGE IMPROVEMENT DETAILS
52 E1 ELECTRICAL SITE PLAN
53 E2 ELECTRICAL SITE LIGHTING PLAN
54 E3 SITE LIGHTING PHOTOMETRIC PLAN
55 E4 PRELIMINARY POWER RISER DIAGRAM
LEGEND
EXISTING PROPOSED
MONUMENT
FENCE
ASPHALT
CONCRETE
SANITARY SEWER MANHOLE
FIRE HYDRANT
STREET LIGHT
SANITARY SEWER MAIN
STORM LINE
STORM MANHOLE TYPE 2
CATCH BASIN TYPE 1
WATER LINE
WALL
CONTOURS
ROW
EASEMENT
XXXXXX
EX. CHAINLINK FENCE AS NOTED
EX. WOOD FENCE AS NOTED
ADDRESS: 505 SW 12TH ST
LEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL SERVICES,
SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025 AT 7:30 A.M.
LOTS 20, 21 AND 22, BLOCK 26, C. D. HILLMAN'S EARLINGTON GARDENS ADDITION TO THE CITY OF
SEATTLE, DIVISION NO. 1 AS PER PLAT RECORDED IN VOLUME 17 OF PLATS, PAGE 74, RECORDS OF KING
COUNTY, WASHINGTON;
EXCEPT THAT PORTION OF SAID LOT 20 LYING EASTERLY OF A LINE DESCRIBED AS FOLLOWS:
BEGINNING AT THE NORTHWEST CORNER OF LOT 22 OF SAID BLOCK 26;
THENCE EASTERLY ALONG THE NORTH LINE OF LOTS 22, 21 AND 20 A DISTANCE OF 63.89 FEET TO THE TRUE
POINT OF BEGINNING;
THENCE SOUTH 9°46"43' EAST 97.06 FEET TO THE SOUTH LINE OF SAID LOT 20 AT A POINT 83.03 FEET
EASTERLY OF THE SOUTHWEST CORNER OF SAID LOT 22 AND THE TERMINUS OF SAID LINE;
TOGETHER WITH THAT PORTION OF VACATED ALLEY DESCRIBED UNDER ORDINANCE NO. 4914 RECORDED
SEPTEMBER 6, 2001 UNDER RECORDING NO. 20010906002177.
(TPN 3340404148)
ADDRESS: 519 SW 12TH ST
LEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL SERVICES,
SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025 AT 7:30 A.M.
LOT 1, CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-02-105-LLA, RECORDED NOVEMBER 26, 2002 UNDER
RECORDING NO. 20021126900014, IN KING COUNTY, WASHINGTON.
(TPN 3340404265)
EVA ROUTE THROUGH SITE
R-438801
RENTON CONTROL
MONUMENTS
05/15/2026
AMorganroth
06/03/2026
CURRENT PLANNINGWASTEWATER UTILITY
Mbenoit 06/03/2026
REGIONAL FIRE AUTHORITY
cthomas 06/03/2026
APPROVEDWATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE INTERSECTION OF LIND AVE. SW
AND SW 16TH ST., BEING CITY OF RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG
THE NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF SPRINGBROOK CREEK, BEING
CITY OF RENTON CONTROL ID. 1891, RESPECTIVELY.
SURVEYORS NOTES
1.DATE OF SURVEY NOVEMBER 1ST THROUGH NOVEMBER 26TH, 2024 AND SUPPLEMENTED WITH
ADDITIONAL TOPOGRAPHIC DATA FOR THE NORTHERLY PORTION OF SW 12TH STREET,
FEBRUARY 3RD OF 2025 THROUGH FEBRUARY 6TH OF 2025.
2.NO DEED CORNERS WERE SET THIS SURVEY.
3.THE PURPOSE OF THIS SURVEY FOR CONTEMPLATED DEVELOPMENT OF THE SUBJECT PARCELS
FOR COMMERCIAL USES. TOGETHER WITH RIGHT OF WAY INFORMATION FOR SW 12TH STREET
FOR A CONTEMPLATED WATER MAIN REPLACEMENT.
4.THIS SURVEY DOES NOT PURPORT TO SHOW ANY OR ALL EASEMENTS OF RECORD. THERE MAY
EXIST MATTERS OF TITLE OR EASEMENTS NOT SHOWN HEREON. FULL RELIANCE WAS PLACED
UPON THE TITLE REPORTS PROVIDED TO THIS SURVEYOR.
5.IN ACCORDANCE WITH REVISED CODE OF WASHINGTON (R.C.W.) 58.09 AND THE WASHINGTON
ADMINISTRATIVE CODE (W.A.C.) 332-130, THIS SURVEY MAY DEPICT OCCUPATIONAL
INDICATORS THAT DIFFER FROM THE DEEDED LOT LINES (SUCH AS FENCES, WALLS, TREES,
SHRUBS, BUILDINGS, DECKS, ETC.). THESE INDICATORS, IF AT ALL PRESENT, MAY REPRESENT
A POTENTIAL FOR CLAIMS OF UNWRITTEN TITLE. THIS SURVEY DOES NOT PURPORT TO
RESOLVE SUCH MATTERS. DO NOT REMOVE SUCH ITEMS WITHOUT OWNERS CONSENT
AND/OR LEGAL COUNCIL.
6.THE CONTOUR INTERVAL AS SHOWN ON SHEETS 6 THROUGH 14 IS 1 FOOT AND ARE DERIVED
AND COMPUTED FROM DIRECT FIELD OBSERVATIONS.
7.THE UTILITIES SHOWN HEREON, IF ANY, ARE BASED UPON SURFACE EVIDENCE FIELD
OBSERVATIONS AS DISCOVERED DURING THE PROCESS OF CONDUCTING THE FIELD SURVEY.
TOGETHER WITH SUBCONTRACTED UTILITY LOCATES OF CONDUCTIBLE NATURAL GAS,
SUBTERRANEAN POWER, SUBTERRANEAN TELECOMMUNICATIONS, AND SUBTERRANEAN
WATER AS DEMARCATED AT THE SURFACE VIA PAINT LINES BY MT. VIEW LOCATES ON
11/01/2024 THROUGH 11/12/2024. AND FIELD LOCATED BY MCINNIS ENGINEERING ON
11/01/2024 AND 11/18/2024. SAID UTILITY LOCATES WERE ADDED ON TO BY MOUNTAIN VIEW
ON 02/06/2025 FOR THE NORTHERLY HALF OF SW 12TH STREET. AND FIELD LOCATED BY
MCINNIS ENGINEERING ON 02/06/2025. THE AGREEMENT BETWEEN MCINNIS ENGINEERING
AND MT. VIEW LOCATES WERE FOR CONDUCTIBLE UTILITIES ONLY. THIS SURVEY HAS ALSO
BEEN SUPPLEMENTED WITH RECORD INFORMATION FOR THE STORMDRAIN AND SANITARY
SEWER SYSTEMS WITH DATA FROM THE CITY OF RENTON GIS (GEOGRAPHICAL INFORMATION
SYSTEM) ASBUILT FILES AS HELD BY SAID CITY OF RENTON. SAID RECORD LINES AS DEPICTED
ON THIS SURVEY SHOULD BE TREATED AS APPROXIMATE IN NATURE. UTILITIES MAY EXIST
THAT ARE NOT SHOWN HEREON.
8.THE LIMITS AS AGREED UPON BETWEEN MCINNIS ENGINEERING AND THE CLIENT FOR THIS
SURVEY:
(A) BOUNDARY SURVEYS ONLY FOR KING COUNTY TAX PARCELS 3340404470, 3340404845,
3340404855, 3340404870, AND 3340404865. THE BOUNDARY SURVEY BEING SEARCHING FOR
CORNERS SET BY OTHERS AND LOCATING ANY LINES OF OCCUPATION ALONG THE BOUNDARY
LINES THEREOF.
(B) BOUNDARY AND TOPOGRAPHIC SURVEY FOR KING COUNTY TAX PARCELS 3340404265 AND
3340404148. THE BOUNDARY SURVEY BEING SEARCHING FOR CORNERS SET BY OTHERS AND
LOCATING ANY LINES OF OCCUPATION ALONG THE BOUNDARY LINES THEREOF. TOGETHER
WITH A SURFACE TOPOGRAPHIC SURVEY WITH MEASURED INVERTS OF STORMWATER AND
SANITARY SEWER STRUCTURES ONLY.
(C) TOPOGRAPHIC SURVEY OF HALF WIDTH OF THE ABUTTING RIGHT OF WAY OF SENECA AVE
SW TO KING COUNTY TAX PARCELS 3340404265 AND 3340404148. TOGETHER WITH THE
NORTHEAST QUADRANT OF THE INTERSECTION OF SENECA AVE SW AND SW 12TH ST.
9.THIS SURVEY WAS PREPARED FOR THE EXCLUSIVE USE OF HHJ ARCHITECTS, PLLC AND DOES
NOT EXTEND TO ANY UNNAMED PERSON OR PERSONS WITHOUT EXPRESS CERTIFICATION BY
SURVEYOR NAMING SAID PARTY.
METHODOLOGY
THIS SURVEY WAS PERFORMED VIA CONVENTIONAL AND RADIAL TRAVERSE METHODS WITH A
GEOMAX ZOOM95 3" SECOND TOTAL STATION AND TOGETHER WITH RTK METHODS WITH A
CARLSON BRX7 GPS RECEIVER ROVER INCORPORATING EPOCH CORRECTIONS FROM THE
WASHINGTON STATE REFERENCE NETWORK (WSRN) BASE NAMED "PRNVRS_MSM" THAT MEET OR
EXCEED ACCURACY REQUIREMENTS CONTAINED IN WAC 332.130.090
BASIS OF BEARINGS
REFERENCES
1.PLAT OF C.D. HILLMAN'S EARLINGTON GARDENS ADD'N TO THE CITY OF SEATTLE DIVISION NO.1
2.RECORD OF SURVEY AFN 9404079012
3.CITY OF RENTON LOT LINE ADJUSTMENT LUA-02-105-LLA AFN 20021126900014
4.RECORD OF SURVEY AFN 9511139007
HORIZONTAL DATUM
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY THE CITY OF RENTON
PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND) WAS HELD AT CITY OF
RENTON CONTROL ID. 1895
VERTICAL DATUM
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
PROJECT PRIMARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1895
PUBLISHED ELEVATION: 25.702' NAVD 88
DESCRIPTION:
ENCASED 3" BRASS DISK W/PUNCH LOCATED AT THE INTERSECTION OF LIND AVE. SW AND SW 16TH ST.
PROJECT SECONDARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1891
PUBLISHED ELEVATION: 24.1568' NAVD 88
OBSERVED ELEVATION: 24.06' NAVD 88
DESCRIPTION:
MONUMENT FOUND ALONG THE NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK.
SITE BENCHMARK
OBSERVED ELEVATION: 27.41' NAVD 88
DESCRIPTION:
ENCASED 1 7/8" BRASS DISK W/PUNCH AT THE INTERSECTION OF SW GRADY WAY AND SENECA AVE. SW
01/29/2026
I HEREBY CERTIFY THAT THIS MAP ACCURATELY REPRESENTS A BOUNDARY AND
TOPOGRAPHIC SURVEY THAT WAS PERFORMED BY ME OR UNDER MY DIRECT
SUPERVISION IN CONFORMANCE WITH THE REQUIREMENTS OF WAC 332-130-145..
DURING THE MONTH OF NOVEMBER OF 2024 AT THE REQUEST OF HHJ ARCHITECTS,
PLLC.
______________________________________________________________
LARRY O. WALKER P.L.S. WASH. REG. NO. 49921 DATE
01/29/2026
SURVEYORS CERTIFICATE
49921 DERETSIGER
N
O
T
G
N
IHSAWFOETATS
P
R
O
FESSIONAL L AN D S U RVEYOR
L A R R Y O.WALKE
R
ADDRESSES: 603 SW 12TH ST, 608 SW 12TH ST, AND 611 SW 12TH ST
LEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL
SERVICES, OWNER'S POLICY OF TITLE INSURANCE, POLICY NUMBER 1229154,
FILE NUMBER NCS-1229154-WA1, DATE OF POLICY: OCTOBER 23, 2024
LOTS 29 THROUGH 32, INCLUSIVE, BLOCK 28 AND LOTS 1, 2, 3, 4 AND 5, BLOCK 29, C.D. HILLMAN'SEARLINGTON GARDENS ADDITION TO THE CITY OF SEATTLE, DIVISION NO. 1, ACCORDING TO THE
PLAT THEREOF, RECORDED IN VOLUME 17 OF PLATS, PAGE 74, IN KING COUNTY, WASHINGTON.
LEGAL DESCRIPTIONS
(TPN 3340404845, 3340404855, 334040470, AND 3340404865)
ADDRESS: 505 SW 12TH ST
LEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIALSERVICES, SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025
AT 7:30 A.M.
LOTS 20, 21 AND 22, BLOCK 26, C. D. HILLMAN'S EARLINGTON GARDENS ADDITION TO THE CITY OF
SEATTLE, DIVISION NO. 1 AS PER PLAT RECORDED IN VOLUME 17 OF PLATS, PAGE 74, RECORDS OF
KING COUNTY, WASHINGTON;
EXCEPT THAT PORTION OF SAID LOT 20 LYING EASTERLY OF A LINE DESCRIBED AS FOLLOWS:
BEGINNING AT THE NORTHWEST CORNER OF LOT 22 OF SAID BLOCK 26;
THENCE EASTERLY ALONG THE NORTH LINE OF LOTS 22, 21 AND 20 A DISTANCE OF 63.89 FEET TO THE
TRUE POINT OF BEGINNING;THENCE SOUTH 9°46"43' EAST 97.06 FEET TO THE SOUTH LINE OF SAID LOT 20 AT A POINT 83.03
FEET EASTERLY OF THE SOUTHWEST CORNER OF SAID LOT 22 AND THE TERMINUS OF SAID LINE;
TOGETHER WITH THAT PORTION OF VACATED ALLEY DESCRIBED UNDER ORDINANCE NO. 4914
RECORDED SEPTEMBER 6, 2001 UNDER RECORDING NO. 20010906002177.
(TPN 3340404148)
ADDRESS: 555 SW GRADY WAYLEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL
SERVICES, SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025
AT 7:30 A.M.
LOTS 17 THROUGH 31, INCLUSIVE, BLOCK 27, C. D. HILLMAN'S EARLINGTON GARDENS ADDITION TO
THE CITY OF SEATTLE, DIVISION NO. 1, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17OF PLATS, PAGE 74, IN KING COUNTY, WASHINGTON.
EXCEPT THAT PORTION OF LOT 17 DEEDED FOR HIGHWAY BY RECORDING NUMBER 5429708;
TOGETHER WITH NORTH HALF OF ALLEY ADJOINING VACATED BY CITY OF RENTON UNDER
ORDINANCE NO. 5772,RECORDED OCTOBER 27, 2015 AS RECORDING NO. 20151027000955.
(TPN 3340404470)
ADDRESS: 555 SW GRADY WAYLEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL
SERVICES, SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025
AT 7:30 A.M.
LOTS 32 THROUGH 39, INCLUSIVE, BLOCK 27, C. D. HILLMAN'S EARLINGTON GARDENS ADDITION TO
THE CITY OF SEATTLE, DIVISION NO. 1, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17OF PLATS, PAGE 74, IN KING COUNTY, WASHINGTON;
TOGETHER WITH SOUTH HALF OF ALLEY ADJOINING VACATED BY CITY OF RENTON UNDER
ORDINANCE NO. 5772, RECORDED OCTOBER 27, 2015 AS RECORDING NO. 20151027000955.
(TPN 3340404470)
ADDRESS: 519 SW 12TH ST
LEGAL DESCRIPTION PER FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL
SERVICES, SUBDIVISION GUARANTEE ORDER NUMBER NCS-1252965-WA1, DATED FEBRUARY 27, 2025AT 7:30 A.M.
LOT 1, CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-02-105-LLA, RECORDED NOVEMBER 26, 2002
UNDER RECORDING NO. 20021126900014, IN KING COUNTY, WASHINGTON.
(TPN 3340404265)
LEGAL DESCRIPTIONS AND NOTES
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438802
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
02
SV-01
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
N77°28'05"
E
9
8
8
.
2
8
'
(
M
)
524.50'(M)
463.78'(M)
S0
1
°
2
3
'
1
8
"
W
3
0
0
.
6
5
'
(
C
)
S0
1
°
2
2
'
3
7
"
W
8
9
6
.
4
2
'
S0
1
°
2
2
'
4
9
"
W
2
7
7
.
4
2
'
(
C
)
N77°27'44"E
9
8
8
.
6
6
'
(
C
)
N77°27'51"
E
5
4
6
.
0
8
'
(
M
)
S0
0
°
3
2
'
0
1
"
W
2
9
9
.
6
2
'
N77°27'26"E
5
6
1
.
3
2
'
(
M
)
551.06'(C)
S0
1
°
2
7
'
1
4
"
W
3
0
0
.
8
4
'
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
S0
1
°
2
2
'
4
1
"
W
6
8
8
.
0
6
'
N0
0
°
3
7
'
4
5
"
E
8
5
1
.
4
9
'
(
C
)
27
8
.
2
1
'
(
C
)
57
3
.
2
8
'
(
C
)
510.55'
N89°34'35"E 1029.70'N89°33'27"E 449.61'
N77°23'13"
E
5
4
2
.
4
8
'
(
C
)
N77°24'38"
E
9
8
8
.
9
1
'
(
C
)
N0
1
°
2
0
'
0
1
"
E
30
0
.
7
1
'
(
M
)
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
S0
1
°
2
2
'
4
8
"
W
1
4
7
4
.
5
0
'
(
M
)
(
M
O
N
T
O
M
O
N
)
79
8
.
8
4
'
(
C
)
525.46'(C)
463.45'(C)
519.15'
(BASIS OF BEARINGS)
N89°43'16"W 2274.52'(M)
3
0
'
3
0
'
30
'
30
'
30
'
30
'
3
0
'
3
0
'
30
'
30
'
20'
20'
20'
20'
20'
20'
30'30'
30'30'
50
'
5
0
'
16
'
16
'
1
6
'
16
'
1
6
'
8'
16
'
16
'
30'
30'
30
'30
'
30'30'
60'60'
80'
80'
60'60'
80'80'
90'90'
90'90'
431.89'
10
9
.
1
2
'
N0
1
°
2
6
'
1
4
"
E
10
9
.
1
8
'
237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L16
L2
0
L2
1
N77°24'38"E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L13
L1
4
L8
L1
2
L9
L1
0
L11
L6 L4
L3
L2
L5
L7
L1
L1
9
10
9
.
2
0
'
10
9
.
2
0
'
S77°27'54"W
4
3
2
.
1
3
'
237.33'
8'
8'8
'
75
.
2
0
'
LINE TABLE
LINE NO.
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L20
L21
DISTANCE
60.03'
65.09'
100.95'
65.11'
100.95'
60.00'
100.94'
120.00'
34.96'
100.04'
34.99'
100.07'
120.04'
100.16'
29.98'
63.89'
84.61'
108.12'
108.12'
216.24'
60.12'
BEARING
S77° 27' 38"W
S77° 27' 38"W
N01° 27' 14"E
N77° 27' 51"E
S01° 27' 51"W
N77° 27' 51"E
S01° 27' 00"W
S77° 27' 51"W
N77° 27' 51"E
S01° 23' 10"W
S77° 25' 32"W
N01° 24' 02"E
N77° 25' 32"E
S01° 24' 45"W
N77° 27' 44"E
N77° 27' 44"E
S77° 26' 10"W
N01° 22' 43"E
S01° 22' 43"W
S01° 22' 43"W
S08° 57' 15"E
LEGEND
CALCULATED SUBJECT PARCELS DEED LINE
MEASURED/OR CALCULATED RIGHT OF WAY CENTERLINE
CALCULATED RIGHT OF WAY MARGIN
CALCULATED EASEMENT MARGIN
(SEE SHEET 2 THROUGH 11 OF 11 FOR FURTHER INFORMATION)
FOUND MONUMENT AS NOTED
FOUND REBAR AND CAP AS NOTED
FOUND TACK IN LEAD AS NOTED
MEASURED(M)
SEE REFERENCED DOCUMENT LIST(RX)
CALCULATED(C)
PLAT DIMENSION(P)
MEASURED/OR CALCULATED VACATED RIGHT OF WAY CENTERLINE
CALCULATED VACATED RIGHT OF WAY MARGIN
CALCULATED PLATTED LOT LINE PER LAT OF C.D. HILLMAN'S
EARLINGTON GARDENS ADD'N TO THE CITY OF SEATTLE DIVISION NO.1
CALCULATED EASEMENT AREA
A
MONUMENT DESCRIPTIONS
FOUND ENCASED 2" BRASS DISK W/PUNCH 0.9' BELOW CASE RIM
HELD FOR A POINT ON THE CENTERLINE OF SW GRADY WAY AND
10.26 FEET SOUTHWEST OF THE CENTERLINE INTERSECTION OF
SW GRADY WAY AND RAYMOND AVE. SW
VISITED 11/01/2024
B FOUND ENCASED 1 7/8" BRASS DISK W/PUNCH 0.9' BELOW CASE RIM
HELD FOR THE CENTERLINE INTERSECTION OF SW GRADY WAY AND
SENECA AVE. SW. MONUMENT IS THE EASTERLY OF TWO MONUMENT LOCATED
IN THE AFOREMENTIONED INTERSECTION.
VISITED 11/04/2024
SITE BENCHMARK:
ELEV: 27.41' NAVD 88
C FOUND ENCASED 3/8" BRASS PLUG SET IN CONC W/PUNCH 0.8' BELOW CASE RIM
HELD FOR THE CENTERLINE ALIGNMENT OF LIND AVENUE SW
VISITED 11/04/2024
D FOUND ENCASED 3/8" BRASS PLUG SET IN CONC W/PUNCH 0.8' BELOW CASE RIM
HELD FOR THE CENTERLINE INTERSECTION OF SW GRADY WAY AND MAPLE AVENUE SW
VISITED 11/09/2024
E FOUND TACK IN LEAD SET CONC. BASE, 1.0' BELOW ROAD GRADE
HELD FOR THE CENTERLINE INTERSECTION OF SW 12TH STREET AND RAYMOND AVENUE SW
VISITED 11/01/2024
F FOUND TACK IN LEAD SET CONC. BASE, 1.0' BELOW ROAD GRADE
HELD FOR THE CENTERLINE INTERSECTION OF SW 12TH STREET AND RAYMOND AVENUE SW
VISITED 11/04/2024
G FOUND ENCASED 1 7/8" BRASS DISK W/PUNCH 0.9' BELOW CASE RIM
HELD FOR THE CENTERLINE ALIGNMENT OF LIND AVENUE SW ONLY
VISITED 11/04/2024
H FOUND 1/2" REBAR AND NO CAP, 0.3' BELOW ROAD GRADE
HELD FOR THE CENTERLINE INTERSECTION OF SENECA AVENUE SW AND SW 13TH STREET
VISITED 11/04/2024
I FOUND ENCASED 1 7/8" BRASS DISK W/PUNCH 0.7' BELOW CASE RIM
POSITION NOT HELD
VISITED 11/01/2024
J FOUND ENCASED 1 7/8" BRASS DISK W/PUNCH 1.8' BELOW CASE RIM
HELD FOR THE CENTERLINE INTERSECTION OF RAYMOND AVENUE SW AND SW 16TH STREET
VISITED 11/01/2024
K FOUND ENCASED 1 7/8" BRASS DISK W/PUNCH 0.4' BELOW CASE RIM
HELD FOR THE CENTERLINE INTERSECTION OF MAPLE AVENUE SW AND SW 16TH STREET
VISITED 11/01/2024
L PLEASE SEE SHEET 4 OF 42 FOR DESCRIPTION AND DISPOSITION
M PLEASE SEE SHEET 4 OF 42 FOR DESCRIPTION AND DISPOSITION
N PLEASE SEE SHEET 4 OF 42 FOR DESCRIPTION AND DISPOSITION
O FOUND 5/8" REBAR AND CAP STAMPED "CRONES LS 20537"
REBAR BEARS N32°48'06"E, 0.27' FROM CALCULATED RIGHT OF WAY
ANGLE POINT.
VISITED 11/11/2024
P FOUND 5/8" REBAR AND CAP STAMPED "CRONES LS 20537"
REBAR BEARS S03°17'18"E, 2.89' FROM CALCULATED RIGHT OF WAY
INTERSECTION.
VISITED 11/11/2024
Q PLEASE SEE SHEET 10 OF 42 FOR DESCRIPTION AND DISPOSITION
R PLEASE SEE SHEET 5 OF 42 FOR DESCRIPTION AND DISPOSITION
S PLEASE SEE SHEET 5 OF 42 FOR DESCRIPTION AND DISPOSITION
BLOCK CALCULATIONS DIAGRAM
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 100'
100500 200
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 27
123
31
30 29
626160
32
33 34
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 26
123
31 30 29
626160
32 33 34
28
23 22 21
20
1718
39
40
40 41
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 25
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 22
15 14 13
3 2 1
43
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 30
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 29
16 15 14
17 18 19
3 2 1
5 46
323130
PLAT OF C.D. HILLMAN'S
EARLINGTON ADD'N TO THE
CITY OF SEATTLE DIVISION
NO. 1
BLOCK 28
16 15 14
17 18 19
3 2 1
3231302928
BASIS OF BEARINGS INITIAL POINT
CITY OF RENTON CONTROL POINT ID 1895
HELD PUBLISHED NAD 83/91 WASHINGTON STATE PLANE
NORTH ZONE COORDINATES
HELD A COMBINED GRID SCALE FACTOR OF
0.999987504615 (GRID TO GROUND) AT THIS POSITION
FND. ENCASED 1 7/8" BRASS DISK WITH PUNCH, DOWN 0.4'
VISITED 11/01/2024
PROJECT PRIMARY BENCHMARK
HELD PUBLISHED CITY OF RENTON ELEVATION:
25.702 FEET NAVD 88
BASIS OF BEARINGS SECONDARY POINT
CITY OF RENTON CONTROL POINT ID 1891
HELD PUBLISHED NAD 83/91 WASHINGTON
STATE PLANE NORTH ZONE COORDINATES
FOR ROTATION ONTO DERIVED GRID BEARING
FND. ENCASED 3" BRASS DISK STAMPED "CITY
OF RENTON BENCHMARK". MONUMENT IS
LOCATED ON TOP OF THE NORTHERLY CONC.
WALL OF BRIDGE OF SW 16TH ST. THAT
CROSSES SPRINGBROOK CREEK
VISITED 11/01/2024
PROJECT SECONDARY BENCHMARK
HELD PUBLISHED CITY OF RENTON
ELEVATION:
24.1568 FEET NAVD 88
OBSERVED ELEVATION:
24.06 FEET NAVD 88
A
B
C
D
E
F
G
I J
K
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
(SECOND A
V
E
N
U
E
)
SW 12TH ST
R
E
E
T
LI
N
D
A
V
E
N
U
E
S
W
(THIRD AVE
N
U
E
)
SW 13TH ST
R
E
E
T
LI
N
D
A
V
E
N
U
E
S
W
(R
I
C
E
A
V
E
N
U
E
)
MA
P
L
E
A
V
E
N
U
E
S
W
(M
A
I
N
S
T
R
E
E
T
)
RA
Y
M
O
N
D
A
V
E
N
U
E
S
W
(M
O
R
R
I
S
O
N
A
V
E
N
U
E
)
(FIRST AVE
N
U
E
)
SW GRADY
W
A
Y
ALLEY (VAC
A
T
E
D
)
ALLEY
ALLEY
ALLEY (VAC
A
T
E
D
)
SW 13TH ST
R
E
E
T
(VACATED)
SW 16TH STREET
(FOURTH AVENUE)
L
M
N
O
P
Q
R
CALCULATED
NORTH RIGHT
OF WAY MARGIN
I-405
CALCULATED
NORTH RIGHT
OF WAY MARGIN
I-405
S
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438803
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
03
H
SV-02
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU OHU
GP
GP
GP
GP
GP
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\
N77°27'51"E
5
4
6
.
0
8
'
(
M
)
S0
1
°
2
7
'
1
4
"
W
3
0
0
.
8
4
'
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
OHU
OHU
OHU
OHU
OHU
OHU
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
OH
U
OH
U
OH
U
OH
U
OHU
OHU
117.44'
25
4
.
8
8
'
L13
L1
4
L8
L1
2
L9
L1
0
L11
L6
L4
L3
L2
L5
L7
L1
10
9
.
2
0
'
LEGEND
CALCULATED SUBJECT PARCELS DEED LINE
MEASURED/OR CALCULATED RIGHT OF WAY CENTERLINE
CALCULATED RIGHT OF WAY MARGIN
FOUND MONUMENT AS NOTED
FOUND REBAR AND CAP AS NOTED
FOUND TACK IN LEAD AS NOTED
CHAINLINK FENCECLF
MEASURED/OR CALCULATED VACATED RIGHT OF WAY CENTERLINE
CALCULATED VACATED RIGHT OF WAY MARGIN
CALCULATED PLATTED LOT LINE PER LAT OF C.D. HILLMAN'S
EARLINGTON GARDENS ADD'N TO THE CITY OF SEATTLE DIVISION NO.1
BACK CONCRETE WALKB/W
EXTRUDED CURBE/C
WOOD FENCEWDF
LINE TABLE
LINE NO.
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
L13
L14
DISTANCE
60.03'
65.09'
100.95'
65.11'
100.95'
60.00'
100.94'
120.00'
34.96'
100.04'
34.99'
100.07'
120.04'
100.16'
BEARING
S77° 27' 38"W
S77° 27' 38"W
N01° 27' 14"E
N77° 27' 51"E
S01° 27' 51"W
N77° 27' 51"E
S01° 27' 00"W
S77° 27' 51"W
N77° 27' 51"E
S01° 23' 10"W
S77° 25' 32"W
N01° 24' 02"E
N77° 25' 32"E
S01° 24' 45"W
TAX PARCELS 3340404845, 3340404855, 3340404870, AND 3340404865
BOUNDARY SURVEY
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 20'
20100 40
TAX
PARCEL
3340404845
TAX
PARCEL
3340404855
TAX
PARCEL
3340404865
TAX
PARCEL
3340404870
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
(SECOND A
V
E
N
U
E
)
SW 12TH S
T
R
E
E
T
ALLEY
GATE
GATE
GATE
GATE
FND. 5/8" IRON ROD,
0.5' BELOW GRADE
ROD BEARS
N46°21'53"E, 0.55'
FROM THE
CALCULATED LOT
CORNER
VISITED 11/05/2024
FND. 4" SQUARE CONC. POST WITH 1/2"
O.D. STEEL PLUG WITH PUNCH
WHICH BEARS N25°03'21"E, 0.33' FROM
THE CALCULATED LOT CORNER
VISITED 11/18/2024
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF ANGLE POINT BEARS
N26°43'E, 0.9' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT BEARS
S51°13'E, 0.6' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT BEARS
S08°04'W, 1.1' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT/GATE POST
BEARS N32°00'W, 0.6' FROM
THE CALCULATED LOT CORNER
6' CLF ANGLE POINT BEARS
S07°34'W, 1.1' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT BEARS
N20°11'W, 0.6' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT BEARS
N20°11'W, 0.6' FROM THE
CALCULATED LOT CORNER
ALLEY
GATE
GATE
6' CLF ANGLE POINT BEARS
S86°17'W, 0.3' FROM THE
CALCULATED LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
FND. 1/2" REBAR AND CAP STAMPED
"C&C LS 18077" WHICH BEARS
S35°12'00"E, 0.06' FROM THE
CALCULATED LOT CORNER
VISITED 11/18/2024
16
'
16
'
30
'
30
'
30
'
30
'
30'
30'
30'
30'
30'30'
30'30'
16
'
16
'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438804
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
04
SV-03
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
OH
U
OH
U
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
O
H
U
O
H
U
GP
GP
GP
GP
GP
GP GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\
\
\\\\\
\\\\\\
\\
\
\
\
\
\
\
\\\\\\\\\
\
\
\
\
\
\
\
\\\\\
N77°28'05"
E
9
8
8
.
2
8
'
(
M
)
524.50'(M)
N77°27'44"
E
9
8
8
.
6
6
'
(
C
)
S0
1
°
2
7
'
1
4
"
W
3
0
0
.
8
4
'
N0
1
°
2
0
'
0
1
"
E
30
0
.
7
1
'
(
M
)
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
O
H
U
O
H
U
431.89'
10
9
.
1
2
'
N0
1
°
2
6
'
1
4
"
E
10
9
.
1
8
'
237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L16
L2
0
L9
L4
L3
L2
L5
\
\\\\
GP
GP
T
O
E
TO
P
TO
POHU
OHU
OHU
OHU
OHU
10
9
.
2
0
'
10
9
.
2
0
'
S77°27'54"W
4
3
2
.
1
3
'
237.33'
WATER LINE AND APPURTENANCES
EASEMENT TO THE CITY OF RENTON
PER AFN 9411141062
LEGEND
CALCULATED SUBJECT PARCELS DEED LINE
MEASURED/OR CALCULATED RIGHT OF WAY CENTERLINE
CALCULATED RIGHT OF WAY MARGIN
CALCULATED EASEMENT MARGIN AS NOTED
FOUND MONUMENT AS NOTED
FOUND REBAR AND CAP AS NOTED
FOUND TACK IN LEAD AS NOTED
CHAINLINK FENCECLF
MEASURED/OR CALCULATED VACATED RIGHT OF WAY CENTERLINE
CALCULATED VACATED RIGHT OF WAY MARGIN
CALCULATED PLATTED LOT LINE PER LAT OF C.D. HILLMAN'S
EARLINGTON GARDENS ADD'N TO THE CITY OF SEATTLE DIVISION NO.1
EXISTING CHAINLINK FENCE AS NOTED
BACK CONCRETE WALKB/W
EXTRUDED CURBE/C
EXISTING WOOD FENCE AS NOTED
WOOD FENCEWDF
EXISTING CONCRETE SURFACE
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
EXISTING ASPHALT SURFACE
CALCULATED EASEMENT AREA
TAX PARCEL 3340404470
BOUNDARY SURVEY
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 30'
30150 60
TAX
PARCEL
3340404470
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
(SECOND A
V
E
N
U
E
)
SW 12TH S
T
R
E
E
T
(FIRST AV
E
N
U
E
)
SW GRADY
W
A
Y
LI
N
D
A
V
E
N
U
E
S
W
FND. 1/2" REBAR AND CAP
STAMPED "D.G. 13401"
WHICH BEARS
S44°47'38"E, 0.15' FROM
THE CALCULATED LOT
CORNER
VISITED 11/15/2024
FND. MAGNETIC ASPHALT NAIL AND
WASHER STAMPED "CEI 28101" WHICH
BEARS S00°59'26"E, 9.13' FROM THE
CALCULATED LOT CORNER
ALSO BEING 0.05' EASTERLY OF THE
CALCULATED RIGHT OF WAY MARGIN OF
LIND AVE. SW
VISITED 11/26/2024
ALLEY (VA
C
A
T
E
D
-
C
I
T
Y
O
F
R
E
N
T
O
N
O
R
D
I
N
A
N
C
E
N
O
.
5
7
7
2
)
50
'
30
'
50
'
8'
8'
8'
8'
30
'
30
'
30
'
30'
30'
30'
30'
30'
30'
60'
60'
B/W
E/C
E/C
DRIVEWAY
B/W
E/C
DRIVEWAY
6' CLF END BEARS
N25°15'W, 1.8' FROM THE
CALCULATED LOT
CORNER
6' WDF END BEARS
N06°18'E, 1.9' FROM
THE CALCULATED
LOT CORNER
6' CLF END BEARS
S12°06'W, 9.8' FROM THE
CALCULATED LOT
CORNER
6' WDF END BEARS
S09°34'W, 10.3' FROM
THE CALCULATED LOT
CORNER
E/C
E/C
E/C
E/C
B/W
CONC. WALK
B/W
DRIVEWAY
DRIVEWAY
6' WDF
6' CLF
1.6'
1.0'
CANOPY
CANOPY COLUMN
CANOPY
TAX
PARCEL
3340404470
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438805
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
05
SV-04
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
SD
SD
SD
SD
SD
SD
L15
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OH
U
OH
U
OH
U
OH
U
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
O
H
U
O
H
U
GP
GP
SD
PC
SS
GP
GPGP
GP
GP
GP
GP
RD
IRR
SS
RD
RD
IRR IRR
GP
GP
SS
SS
GP
GP
P
IRR
GP
GP
BOL BOL
IRR
HVACHVAC
RD
RD
BOL
IRR
IRR
GP GP
GP
G
P
GPGP
GP
GP
GP
RD
RD BOL
BOL
RD
RD
RD
RD
RD
BOL
FDC
SSSS
COCOBOLBOLBOL
SS
BOLBOL
BOL
GP
SD SD
RDBOLBOL
BOL
BOL
BOLBOL
GP
GP
CORD
GP
BOL
BOL
CO
RDGP GP
GP
GP
P
BOLCOBOL
GP
GP
BOLBOLGP
GP
HVACHVAC
P
GP
GP
GP
GP
SS
\
\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\
\\\\\\\\\\
\
\
\\\\
\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
TOPTOPTOP
TO
P
TOP TOP TOP
TO
P
TOETOETOE
TOE TOE TOE TO
E
TOP TOP
TO
P
TO
P
TO
P
TOP
TO
P
TO
P
TO
P
TOE
TO
E
TO
E
T
O
E
TO
E
TO
E
TO
E
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\\\\\\\
\
\
\
\
\
\
\
\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\
\
\\\\\
\\\\\\
\\
\
\
\
\
\
\
\\\\\\\\\
\
\
\
\
\
\
\
\\\\\
G
G
G
G
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
F
O
FO
FO
FO
FO
P
P
G
G
G
G
G
G
G
G
G
GG
W
W
W
T
T
T
PW
W
W
W
W
W
W
W
W
W
W
W
P
P
P
P
P
P
P
PP
P
P
P
P
P
P
P
P P
P P
P
P
P P P P P
W
W
T
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
W
W
W
W
W
W WW
P
P
P
P
P
P
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W
W
W
T
T
T
P
T
T
PPP
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
N77°27'44"
E
9
8
8
.
6
6
'
(
C
)
S0
1
°
2
7
'
1
4
"
W
3
0
0
.
8
4
'
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
SD
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
D
S
D
G
G
G
G
G
G
G
G
G
G
G
O
H
U
O
H
U
O
H
U
O
H
U
OH
U
OH
U
OH
U
OH
U
OH
U
OHU
SD
SD
SD
SS
(
R
E
C
)
SD
SD
SD
SD
SD
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
525.46'(C)
N0
1
°
2
6
'
1
4
"
E
10
9
.
1
8
'
237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L16
L2
0
L2
1
N77°24'38
"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
2
L9
L1
0
L11
L4
L3
L2
L1
9
GP
GP
P IRRIRRIRR
C C
C
T
O
E
TO
P
TO
P
PP
TT
T
T
T
T
T
G
P
P
P
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
P
P
T
G
SD
S
D
SD
SD
SD
OHU
OHU
OHU
OHU
OHU
SD
10
9
.
2
0
'
75
.
2
0
'
LINE TABLE
LINE NO.
L15
L16
L17
L18
L19
L20
L21
DISTANCE
29.98'
63.89'
84.61'
108.12'
108.12'
216.24'
60.12'
BEARING
N77° 27' 44"E
N77° 27' 44"E
S77° 26' 10"W
N01° 22' 43"E
S01° 22' 43"W
S01° 22' 43"W
S08° 57' 15"E
LEGEND
EXISTING 1 FOOT MAJOR CONTOUR INTERVALXXX
EXISTING 1 FOOT MINOR CONTOUR INTERVALXXX
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\EDGE EXISTING ASPHALT PAVING
EXISTING CHAINLINK FENCE AS NOTED
EXISTING WOOD FENCE AS NOTED
EXISTING STORMDRAIN LINE
EXISTING CONCRETE SURFACE
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
EXISTING ASPHALT SURFACE
SD SD
EXISTING GRAVEL SURFACE
XX.X'EXISTING GROUND SPOT ELEVATION
ALL GRADES ALONG CURB ARE AT FLOWLINE
EXISTING 6" IN DIAMETER OR BIGGER DECIDUOUS TREE
AS NOTED
EXISTING 6" IN DIAMETER OR BIGGER CONIFEROUS TREE
AS NOTED
EXISTING ECOBLOCK RETAINING WALL
(GRADE POINT ARROW IS AT TOE FACE WALL)
BOL
GP
SS
SD
RD
HVAC
P
P
C
FDC
FOUND MONUMENT AS NOTED
FOUND REBAR AND CAP AS NOTED
FOUND TACK IN LEAD AS NOTED
EXISTING STORMDRAIN MANHOLE
EXISTING STORMDRAIN CATCHBASIN
EXISTING STORMDRAIN YARD DRAIN
EXISTING STORMDRAIN CULVERT END
EXISTING STORMDRAIN ROOF DRAIN
EXISTING SANITARY SEWER MANHOLE
EXISTING POWER VAULT
EXISTING PAD MOUNTED TRANSFORMER
EXISTING POWER METER
EXISTING LUMINAIRE
EXISTING TELECOMMUNICATIONS MANHOLE
EXISTING TELECOMMUNICATIONS RISER
EXISTING NATURAL GAS VALVE
EXISTING NATURAL GAS METER
EXISTING WATER METER
EXISTING WATER VALVE
EXISTING FIRE HYDRANT
EXISTING FIRE DEPARTMENT CONNECTION
EXISTING POST INDICATOR VALVE
EXISTING WATER HOSE BIB
EXISTING UTILITY POLE
EXISTING GUY ANCHOR
EXISTING UTILITY JUNCTION BOX
EXISTING HVAC UNIT
CO EXISTING UNKNOWN USE CLEANOUT
EXISTING GATE POST
EXISTING BOLLARD
EXISTING SIGN AS NOTED
CONCRETECONC.
TOP WALL GRADE AT TOP BACK WALLTW
BOTTOM WALL GRADE AT TOE FACE WALLBW
EXISTING SANITARY SEWER LINESSSS
RECORD POSITION EXISTING SANITARY SEWER LINE
(SEE SURVEYORS NOTE 8, SHEET SV-01)
SS(REC)SS(REC)
EXISTING WATER LINEWW
EXISTING SUBTERRANEAN POWER LINEPP
EXISTING SUBTERRANEAN TELECOMMUNICATIONS LINETT
EXISTING SUBTERRANEAN FIBER OPTICS LINEFOFO
EXISTING OVERHEAD UTILITY LINEOHUOHU
TOP TOP EXISTING TOP OF SLOPE
TOE TOE EXISTING TOE OF SLOPE
EXISTING NATURAL GAS LINEGG
CONCRETE CURB AND GUTTERC/G
EXTRUDED CURBE/C
RAISED CONCRETE WALKWAYRA/W
CURB CUTC/C
ASPHALT WEDGE CURBA/W
CALCULATED SUBJECT PARCELS DEED LINE
MEASURED/OR CALCULATED RIGHT OF WAY CENTERLINE
CALCULATED RIGHT OF WAY MARGIN
MEASURED/OR CALCULATED VACATED RIGHT OF WAY CENTERLINE
CALCULATED VACATED RIGHT OF WAY MARGIN
CALCULATED PLATTED LOT LINE PER LAT OF C.D. HILLMAN'S
EARLINGTON GARDENS ADD'N TO THE CITY OF SEATTLE DIVISION NO.1
CHAINLINK FENCECLF
CALCULATED EASEMENT MARGIN AS NOTED
CALCULATED EASEMENT AREA
TAX PARCELS 3340404265 AND 3340404148
OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY DIAGRAM
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 30'
30150 60
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
(SECOND
A
V
E
N
U
E
)
SW 12TH ST
R
E
E
T
LI
N
D
A
V
E
N
U
E
S
W
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
I-405
TAX
PARCEL
3340404265
TAX
PARCEL
3340404148
NOT PART OF
SURVEY
TAX PARCEL
3340404150
BOUNDARY AND TOPOGRAPHIC
SURVEY DETAIL SHEET MATCHLINE
(SHEETS 7 THROUGH 14)
(TYPICAL)
(SHEET 7 OF 55)
(SHEET 8 OF 55)
(SHEET 9 OF 55)
(SHEET 10 OF 55)
(SHEET 11 OF 55)
(SHEET 12 OF 55)
ALLEY (VAC
A
T
E
D
-
C
.
O
.
R
.
O
R
D
I
N
A
N
C
E
4
9
1
4
)
16
'
90'
16
'
8'
8'
8'
8'
16
'
30
'
30
'
30
'
30
'
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
-
(VACATED
-
C
.
O
.
R
.
O
R
D
I
N
A
N
C
E
4
9
4
2
)
90'
80'
80'
30
'
30
'
30
'
30
'
30
'
30
'
30'
30'
30'
30'
30'
30'
30'30'
30'
30'
30'
UTILITIES EASEMENT
TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
UTILITIES EASEMENT
TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHT AND RESPONSIBILITIES
AFN 20020612000622
PSE ELECTRICAL EASEMENT
PER AFN 20030128002591
QWEST
TELECOMMUNICATIONS
EASEMENT
PER AFN 20030327000928
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438806
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
06
(SHEET 13 OF 55)
(SHEET 14 OF 55)
SV-05
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
SD
P
C
GP
G
G
G
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
G
G
P
P
P
P
T
P P
P
P
P
P
P
P
P
P
W
W
W
W
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
P
P
P
P
P
P
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T
T
T
T
T
T
T
T
T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
T T T T
T
T
T
T
T
T
P
P
P
P
P
T T T
T
T
T
T
P P PPPP
P P P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
21
21
2
1
2
1
21
21
22
22
2
2
22
21 22
21
21
21 21
21
2
2
22
22
21
2
1
21.5'
21.4'
21.4'
21.3'
21.2'
21.1'
20.7'
20.9'
21.2'
21.3'
21.4'
21.5'
21.6'
21.7'
21.7'
21.8
'
21.8'
21
.
3
'
21
.
3
'
21
.
4
'
21
.
0
'
20
.
7
'
20
.
6
'
20
.
4
'
20
.
5
'
21.0'
21.
0
'
21.
2
'
21.4'
21
.
3
'
21.6'
21
.
6
'
21.
8
'
21.7'
21
.
8
'
21.6
'
21.
9
'
22.
0
'
2
2
.
0
'
21.
8
'
2
1
.
7
'
2
1
.
6
'
21.6'21.
6
'
21.7'
20
.
4
'
2
0
.
7
'
2
0
.
7
'
20.5
'
20.9
'
20.8
'
20.
9
'
20.5
'
20.6'
21.0'
20.6'21.2'
20.7'21.4'
22.3'
22.3'
22.4'
22
.
4
'
22.7'
21
.
3
'
21.3'
21.2'
20.5'
2
2
.
0
'
2
1
C/GC/G
C/G
C/G
E/C
E/C
E/C
C/C
C/C
RAMP
RAMP
C/C
C/C
12"
MAPLE
14"
MAPLE
C/C
C/C
31.3'
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
C/G
C/C
6' CLF
6' CLF
0.6'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
21.8'
21
.
5
'
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
E/C
22.2'
2
2
.
1
'
NOT PART OF SURVEY
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
(SECOND A
V
E
N
U
E
)
SW 12TH S
T
R
E
E
T
6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
"STOP"
STOP BAR
SD
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.39'
IE=17.67' 12" PVC E
IE=17.68' 12" PVC SW
IE=17.65' 12" PVC NW
S
D
S
D
S
D
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.61'
IE=17.45' 12" PVC N
IE=17.48' 12" PVC S
SD
SD
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.95'
IE=17.24' 12" PVC NE
IE=17.26' 12" PVC S
IE=17.07' 12" PVC W
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.14'
IE=17.10' 12" PVC W
SD
SD
(
R
E
C
)
STORMDRAIN CATCHBASIN
DID NOT OPEN
RIM=22.04'
12"
MAPLE
17"
MAPLE
SD
(
R
E
C
)
SD(REC)
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.20'
IE=18.13' 12" PVC NE
IE=18.41' 12" PVC SE
IE=18.17' 12" PVC SW
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.80'
IE=19.04' 8" SW
IE=18.97' 12" PVC NW
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.15'
IE=18.22' 12" PVC NE
IE=18.27' 12" PVC SW
SD
SD
SD
STORMDRAIN CATCHBASIN
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.70'
IE=17.88' 12" PVC NE
IE=17.81' 12" PVC NW
237.36'
117.44'
L3
GP
GP
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
PT
T
T
T
G
G
G
G
GP
P
T
C/G
C/G
22
22
23
23
22
22
23
22
23
22
23
22
21.8'
21.
0
'
21.
5
'
21.
1
'
21.
6
'
21.5'
23.5'
23.6'
2
1
.
1
'
21.
7
'
21
.
2
'
21
.
8
'
21.8'
21.8'
23.2'
23.1'
23.5'
23.4'
23.6'
21
.
2
'
21
.
8
'
C/C
C/C
14.9'
DRIVEWAY
21
.
5
'
2
1
.
4
'
22
.
0
'
2
2
.
1
'
22.1'
22.0
'
GATE
E/C
E/C
22
22 2
2
22
2
1
.
9
'
15"
UNKNOWN
DECIDUOUS
13"
UNKNOWN
DECIDUOUS
15"
UNKNOWN
DECIDUOUS
CONC. STEPS
W/HANDRAIL AT CENTER
6' CLF
10
9
.
2
0
'
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
8
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 10 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438807
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
07
SV-06
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
CO
RD GP GP
GP
GP
P
BOL
CO
BOL
GP
GP
BOL
BOL
GP
GP
\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\\\\\\\\\\\
\
\\
\
\
\\\\\\\\\\\\\\\\\\
\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\
\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
T
T
W
F
O
F
O
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
P
P
P
P
P
P
P
P
T
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
W
W
W
W
W
W
W
W
W
T
T
T
T T
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W W W W
W
W
W
W
W
W
W
W
W
W
N77°27'44"
E
9
8
8
.
6
6
'
(
C
)
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
\\
22
C/C
22
22
22
22
22 22
22
22
21.8'
21.7'
21.7'
21.6'
21.6'
21.
6
'
21.5'
21.6'
20.
9
'
21.1'21.
3
'
21
.
3
'
21
.
3
'
21
.
8
'
21.3'
21
.
4
'
21
.
5
'
22
.
0
'
22.0'
2
2
.
2
'
22.
1
'
22.1'
22.2
'
22
.
2
'
22.
2
'
2
2
.
1
'
22.2'
22.4'
21.6'
21.7'
22.0'
22.1'
22.1'
22.1'
21.7'
21.7'
21.6
'
21.
7
'
21.3
'
21.4
'
21.
3
'
21.
5
'
2
1
.
5
'
21.
6
'
21.9'
21.
8
'
21.8
'
23.9'
DRIVEWAYG
G
G
G
G
G
G
20.6'
DRIVEWAY
24.2'
DRIVEWAY
C/C ASPHALT
RAMP
C/G
C/G
C/G
E/C
E/C
A/W
A/W
22.2'
2
2
.
1
'
21
.
9
'
22.1'
21
NOT PART OF SURVEY
GATE
GATE
GATE
C/C
C/C
2
1
.
0
'
GATE
0.5'
0.4'
0.3'
4.9'
8.0'
22
.
2
'
6' CLF 7' CLF
7' CLF
0.2'
0.3'
0.2'
7' CLF
6' CLF
6' CLF
6' CLF
2
1
.
9
'
6' CLF
LI
N
D
A
V
E
N
U
E
S
W
(SECOND A
V
E
N
U
E
)
SW 12TH ST
R
E
E
T
6'/7' CLF ANGLE POINT
BEARS N89°50'E, 0.6'
FROM CALCULATED
LOT CORNER
14.4'
SD
UNKNOWN USE
CLEANOUT
RIM=21.96'
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.07'
IE=18.55' 8" PVC NE
IE=18.42' 12" PVC SW
SD
SD
SD
SD
SD
SD
SD
S
D
S
D
S
D
S
D
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.76'
FULL OF DIRT
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L16
P IRR
IRRIRR
C C
C
TO
E
T
O
E
T
O
E
TO
E
TO
P
TO
P
TO
P
TO
P
TO
P
TO
P
W
W
W
W
W
W
W
P
P
P
P
P
P
P
P
P
P
P
P
P P P P
P
P
P
T
T
T
T
T
T
T T
T
FO
FO
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
FO
G
G
G
G
G
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P P
T
T
T
T
T T T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
FO
P
T
T
SD
SD
SD
SD
SD
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
22
22
22
23
22
22
22
23
22
22
22
23
23
22
23
24
24
24
23
23
23
23
23
23 24
24
24
24
25
25
25
25
25 26
26
24232221
21
20
21
22
2
3
24
2
3
24
24
23
2
2
22
21
21
21
.
1
'
2
1
.
7
'
22.3'
23
.
1
'
23.
0
'
21
.
2
'
21.
8
'
22.2'
22.
7
'
21
.
3
'
22
.
0
'
23.0'
23.
5
'
21
.
2
'
21
.
9
'
22.6'
22.7'
21
.
5
'
22.
0
'
23.8'22
.
1
'
2
2
.
8
'
24.2'
21.5'
21.1'20.2'25.1'
26.0'25.4'
23.9
'
23
.
7
'
23.1'
22.0
'
20
.
8
'
21.6
'
20
.
7
'
21.4'
21.
4
'
21.
2
'
2
2
.
2
'
22.2'
21.9'
24.7'
25.4'
24.7'
24.3'
23.
7
'
22
.
6
'
21.8'
22.1'
22.4'
22.7'
22.9'
23.2'
23.4'24.0'24.3'24.5'24.5'
25.0'
25.3'
25.
5
'
25.4'
23.8'
22.9'23.6'24.1'24.1'
23.1'
22.5'
2
2
.
5
'
23.0'
22.3'
22.9'
22.8'
24
.
4
'
C/C
C/C
RAMP
6' CLF
6' CLF
1X7", 5X4", 4X3"
UNKNOWN
DECIDUOUS
6' CLF
6' WDF
6' WDF
6' WDF
1X7" AND 14X3"
UNKNOWN
DECIDUOUS
1X7" AND 14X3"
UNKNOWN
DECIDUOUS
RAMP
C/C
C/C
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
6' CLF
6' CLF
6' CLF
STORMDRAIN CULVERT END
IE=19.03' 16" CMP
SD
SD
SD
SD SD
UTILITY
LOCATE
PAINTED
STUB MARK
C/G
C/G
C/G
1X9",2X7",1X4"
UNKNOWN
DECIDUOUS
STORMDRAIN CATCHBASIN
2.1' X 1.7'
RIM=23.56'
IE=20.43' 6" DI NE
IE=20.53' 6" DI SW
IE=22.81' 4" PVC NW
STORMDRAIN CATCHBASIN
TYPE I W/SOLID LID
RIM=23.34'
IE=20.10' 6" DI SE
IE=20.25' 6" DI SW
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.08'
IE=19.65' 6" PVC NE
IE=19.58' 8" CMP SE
IE=19.74' 6" DI NW
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.91'
IE=19.84' 8" DI SE
STORMDRAIN CATCHBASIN
TYPE II W/GRATED LID
RIM=21.88'
IE=19.46' 12" DI NE
IE=19.39' 16" CMP SE
IE=19.74' 8" SW
IE=19.07' 8" DI NW
FULL OF WATER
TOP WATER=20.25'
21.
5
'
"STOP"
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.87'
IE=19.58' 12" DI NE
C/G
C/G
C/G
C/G
C/G
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
7
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 9 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438808
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
08
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-07
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
COCO
BOL
BOL
BOL
RDBOL
BOL
BOL
BOL
BOL
BOL
GP
GP
CO
RD
GP
BOL
BOL
CO
RD
P
SS
\\\\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\
P
T
T
T
T
T
T
T
T
T
T
T
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
22 22
22.2
'
22.
2
'
22.7'22.1'
21.9'
21.7'
21.7'
21.6
'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART
OF SURVEY
(TAX
PARCEL NO.
3340404150)
0.1'
4.9'
6' CLF
22.4'
ALLEY (VAC
A
T
E
D
-
C
.
O
.
R
.
ORDINANC
E
4
9
1
4
)
22
22
2
2
22
22
22
22
22
22
22
22.6'
22.8'
23.1'
22.4'
2
2
.
2
'
22.1'
22.1'
23
.
1
'
22.
5
'
22.8'21.8'21.7'
21.5'
21.5
'
22.
2
'
21.8'
21.
7
'
21.8'
22.0'
22.1'
21.9'
22.0'
22.0'
22.1'
22.0'
21.9'
6' CLF
6' CLF
6' CLF
E/C
22.1'
E/C
E/C
22
5.1'
9.0'
23
2
3
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.31'
IE=19.00' 8" PVC N
IE=18.79' 8" PVC SW
IE=19.15' 6" PVC W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
22.0'
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.46'
IE=19.69 8" PVC S
SANITARY SEWER MANHOLE
OIL WATER SEPARATOR VAULT NORTH ACCESS LID
W/CONC. BAFFLE WALL UNDERNEATH
RIM=21.54'
BOTTOM VAULT NORTH OF BAFFLE WALL=13.7'
TOP OF CONC. BAFFLE WALL=17.84'
BOTTOM VAULT SOUTH OF BAFFLE WALL=13.4'
WATER LEVEL BOTH SIDES OF BAFFLE WALL=17.0'
NOTE: BOTTOM OF VAULT HAS HEAVY SLUDGE DEBRIS
AND NO PIPE SEEN HEADING TO THE NORTH TOWARDS
OBSERVED CLEANOUTS
SANITARY SEWER MANHOLE
OIL WATER SEPARATOR VAULT SOUTH ACCESS LID
W/CONC. BAFFLE WALL UNDERNEATH
RIM=21.41'
IE=17.18' 6" PVC W/OIL WATER SEPARATOR ELBOW SE
BOTTOM VAULT NORTH OF BAFFLE WALL=13.1'
TOP OF CONC. BAFFLE WALL=17.86'
BOTTOM VAULT SOUTH OF BAFFLE WALL=13.1'
WATER LEVEL BOTH SIDES OF BAFFLE WALL=17.0'
NOTE: BOTTOM OF VAULT HAS HEAVY SLUDGE DEBRIS
0.9'
1.0'
0.9'
UNKNOWN USE
CLEANOUT
RIM=21.61'
UNKNOWN USE
CLEANOUT
RIM=21.65'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
L2
0
L1
9
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
1
0
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 8 OF 55 FOR CONTINUATION
SHEET MATCHLINE
SEE SHEET 12 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438809
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
09
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-08
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU OHU OHU
SS
GPGP
GP
GP
RD
IRR
SS
RD
RD
GP
RD
COCOBOL
BOL
HVACHVAC
P
GP
GP
\
\
\
\
\
\
\\\\\\\\\\\\\
G
G
G
G
G
G
G
G
G
G
G
GT
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
T
T
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
SS
SS
SS
SS
SS
SS
SS
SS
21
2
1
21
21
20.8'
20.7'
20.9'
21.0'
21
.
0
'
21.
2
'
21.4'
21
.
6
'
21.6'
21.6'
21.5'
21.3'
2
1
.
4
'
21.4'
21.
6
'
21.7'
20.
2
'
20
.
4
'
20.
3
'
20.1'
20.7'20.9'
21.0'
21.3'
C/C
C/C
C/C
RAMP
20
.
3
'
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
C/G
E/C
E/C
E/C
E/C
E/C
E/C
6' CLF
6' CLF
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)G
G
G
G
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
OF SURVEY
PARCEL NO.
3340404150)
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
ALLEY (VAC
A
T
E
D
-
C
.
O
.
R
.
ORDINANC
E
4
9
1
4
)
22.0'
E/C
E/C
E/C
6' CLF
6' CLF
6' CLF
21
21
21
21
21
21
STOP BAR
C/G
C/G
C/G
C/G
C/C
C/C
30.0'
DRIVEWAY
E/C
21.7'
21
.
7
'
2
1
.
5
'
21.5
'
21.5
'
21.4'
21.4'
21.3'
21.5'
21.5'
21.5'
21.6'
21.5'
21.4'
21.4'
21.3'
21.3'
21.3'
21.3'
21.4'
21.3'
21.2'
21.3'21.
3
'
21.3'
2
1
.
4
'
21.
4
'
21.9'
21.9'
21.4'
21.4
'
21
.
4
'
21.4
'
21.4'22.0'
22.0'
22.0'
22.0'
22.
0
'
2
2
.
0
'
2
1
.
9
'
2
2
.
0
'
2
1
.
4
'
21.
4
'
21.4
'
21.5
'
22.0'
21.9'
21.9'
21.8'
21.7'
21.8'
21.7'
21
.
8
'
21.9'
21.7'
21.8'
22.0'
21.6'
21.5'
21.5'
21.4'
20.1'
20.1'
20.2'
20.3'
20.3'
20.9'
20.8'
2
0
.
7
'
21.4'
21.5'20.
7
'
20.8'
20.8'
20.7'
20.7'
20.7
'
20.6'
20.3'
20.6'
21.5'
21.5'21.4'21.5'
22.0'
21.9'
21.4'21.4'
21.9'
21.4'
20.7'
20.7'21.0'
20.
7
'
20
.
7
'
RA/W
RA/W
RA/W
RA/W
21.8'
21.6'
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
21.3'
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
12"
MAPLE
13"
MAPLE
12"
MAPLE
13"
MAPLE
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
O
H
U
OH
U
OH
U
OH
U
OH
U
OHU
OHU
OHU
OHU
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
SD
SD
SD
SD
SD
SD
SD
SD
UNKNOWN USE
CLEANOUT
RIM=21.65'
SANITARY SEWER
MANHOLE
W/ CONC. CHANNEL
RIM=20.52'
IE=12.41' 8" CONC. NE
IE=12.52' 8" CONC. S
IE=12.22 8" CONC. SW
LADDER=S
SANITARY SEWER MANHOLE
NO CHANNELIZATION - PIPE PASSES
THROUGH IN AIR WITH
CLEANOUT/REDUCER IN MIDDLE - NO
ACCESS TO IE'S - STRUCTURE FILLED WITH
WATER
RIM=21.34'
TOP PIPE=16.94' 6" PVC NE
TOP PIPE=17.01' 8" PVC SW
TOP WATER=16.75'
LADDER=NW
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SS(REC)
SD
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.20'
IE=19.10' 12" PVC SW
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.70'
IE=17.92' 12" PVC NE
IE=18.01' 12" PVC S
SD
SD
SD
SD
SD
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"E
119.92'
L1
0
L11
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.20'
IE=18.88' 12" PVC NE
IE=18.77' 6" PVC SE
IE=18.75' 12" PVC S
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
9
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 7 OF 55 FOR CONTINUATION
SHEET MATCHLINE
SEE SHEET 11 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438810
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
10
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-09
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
SD
SD
SD
SD
SD
SD
SD
SD
SD
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
GP
GP
IRR IRR
GP
GP
SS GP
GP
P
IRR
GP
GP
BOL
BOL
HVAC HVAC
RD
RD
BOL
RD
RD BOL
BOL
RD
RD
RD
RD
RD
BOL
FDC
COCOBOL
BOL
BOL BOL
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\\
\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\
\\\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\\\\\\\\\\\\
\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\
\
\
\
\
\
\
\
TO
P
\
\
\
\
\\\\\\\\\\
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
W W
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
W
W
W
W
W
W
W
W W W W W W
W W W W
\
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
D
S
D
S
D
S
D
S
D
S
D
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
(
V
A
C
A
T
E
D
-
C
.
O
.
R
.
O
R
D
I
N
A
N
C
E
4
9
4
2
)
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
21.4
'
7.9' TALL CMU WALL
W/CANOPY
E/C
E/C
21
2
1
21
C/G
20.2'20.8'
20.3'
20.6'
20.5'
20.4'20.5'
20.5'
21.5'
21.5'
21.5'
21.4'21.9'
21.4'
21.3'
21.4'21.9'
RA/W
RA/W
22
22
21.5'
21.5'21.6'
21.8'
21.6'
21.6'
21.6'
21.6
'
21.8
'
2
1
.
8
'
21.9'
21.8'
21.8'
2
1
.
8
'
21.3'
21.5'
21.
8
'
21.9'21.9'
DUMPSTER
CONC. PAD
AREA
ECO
BLOCKS
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
E/C
E/C
CONC.
CANOPY
COLUMN
GATE
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
(V
A
L
E
N
T
I
N
E
A
V
E
N
U
E
)
SE
N
E
C
A
A
V
E
N
U
E
S
W
2
1
21
21
2
1
21
21
21
2
1
22
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
OH
U
STEEL POST
21.4'21.9'
21.4'
21.9'
21.2'
21.2'
21.3'
21.4'
21.4'
21.5'
21.5'
21.5'
21.6'
21.5'
21.5'
21.8'2
1
.
9
'
21.7'
21.6'
21.6'
21.7'
21.6'
21.6'
21.6'21.7'
21.8'
21.8'21.8'
21.7'
21.6'
21.6'
21.6'
21.5'
21.5'
21.6'
21.6'
21.6'
21.6'
21.6'
21.6'
21.5'
21.5'
21.5'
21.5'
21.4'
21.4'
21.4'
21.3'
21.4'
21.3'
21.3'
21.
6
'
21.5'
21.4'
21.3'
21.3'
21.3'
21.5'
2
1
.
5
'
2
1
.
8
'
2
1
.
8
'
21.8'
21.
6
'
21.
7
'
21.8
'
21.8
'
21.8
'
21.7'
21.7'
21.3'
21.5'
21.5'
21.3'
21.2'
21.3'
21.
6
'
21
.
5
'
2
1
.
7
'
21.
5
'
2
1
.
5
'
2
1
.
4
'
21.4'
21.
6
'
21.6
'
21.6'
21.7'21.6'
21.5'
22.0'
21.9
'
21.9'
21.
7
'
21.7'
21.
8
'
21.
3
'
20.7'
20.9'
20.9'
20.6'
20.5'
20.5'
20.4'
20.6'
20.8'
20.8'
20.6'
20.5'
20.5'20.4'
20.4'
20.3'
20.4'
20.4'
20.5'
20.8'
20.9'
20.7'
21.2'
21.2'
21.3'
21.0'
20.6'
20.5'
20.5'21
21
22
22
22
22 2
2
2
2
22
22
2
2
22
22
22
21.3'
21
E/C E/C
E/C
E/C
E/C
E/C
E/C
E/C
E/C
20.2'
20.1'20
.
7
'
20.6'
20.7'
20.8'
C/C
26.9'
DRIVEWAY
C/G
C/G
GATE
RA/W
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
21.2'
21.2'
8"
UNKNOWN
DECIDUOUS
6"
UNKNOWN
DECIDUOUS22
22
1X7" 1X6"
UNKNOWN
DECIDUOUS
21.5'
21.6'
TW=21.6'
BW=20.8'
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.16'
IE=18.47' 8" PVC N
IE=18.37' 8" PVC NE
IE=18.18' 12" PVC SE
IE=18.25' 8" PVC NW
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D SD
SD
SD
SD
SD
SD
SD
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.93'
IE=18.91' 6" PVC NW
IE=18.68' 8" PVC SE
S
D
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.17'
IE=18.50' 8" PVC N
IE=18.90' 6" PVC NE
IE=18.44' 8" PVC SE
IE=18.98' 6" PVC W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SDSTORMDRAIN CATCHBASIN
TYPE I
RIM=20.04'
IE=18.32' 12" PVC N
SANITARY SEWER
MANHOLE
W/ CONC. CHANNEL
RIM=20.83'
IE=12.93' 8" CONC. N
IE=13.03' 8" CONC. NE
LADDER=W
25
4
.
8
8
'
4' CLF
75
.
2
0
'
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
1
2
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 10 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438811
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
SHEET MATCHLINE
SEE SHEET 14 OF 55 FOR CONTINUATION
11
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-10
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
SS
IRR
IRR
GP GP
GP
GP
GP
G
P
GP
GP
GP
SS
SS
COCO
BOL
BOL
BOL
SS
BOL
GP
SD
SD
RDBOL
BOL
\
\
\
\
\
\
\
\
\
\
\
\
\
TOPTOPTOPTOPTOPTOPTOPTOPTOPTOP
TO
P
TOP
TO
PTOETOETOETOETOETOETOETOETOETOE
TOE TOE TOE TOE
TO
E
T
O
P
T
O
P
TOP TOP
TOP
TOP
TO
P
TO
P
TO
P
TO
P
TO
P
TO
P
TO
P
T
O
P
T
O
P
TOPTOP
TOP
TOP
TO
P
TO
P
TO
P
TO
P
TO
P
TO
P
TO
P
T
O
E
TOE TOE
TO
E
TO
E
TO
E
TO
E
TO
E
TO
E
TO
E
T
O
E
TOETOE
TO
E
TO
E
TO
E
TO
E
TO
E
TO
E
TO
E
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\\
\
\
\
\
\
\\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
P
P
P
W
W
W
W
W
W
W
W
W
P
P
P
P
P
P
P
P
P
P
P P P P P P P
P
SD
SD
SD
SD
SS
SS
S
D
S
D
(R
I
C
E
A
V
E
N
U
E
)
LI
N
D
A
V
E
N
U
E
S
W
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
(
V
A
C
A
T
E
D
)
21
21
21
22.
2
'
21.7'
21.5'
21.1'
20.6'
21.4'
21.5'
21.4'
21.7'
21.4
'
21.
7
'
6' CLF
8' CLF7.9' TALL CMU WALL
W/CANOPY
ASPHALT
CONTAINMENT
HUMP
E/C
GATE
GATE
6' CLF
21.6'
2
1
.
9
'
21.
8
'
21.7'
21.3'
1X6" 1X5"
UNKNOWN
DECIDUOUS
21
21
21
21
21
2
1
20
20
21
21
21
20
19
18
17
17
18 19 20 21
21
17
181920212222
22
22
2
2
22 21 20 19
18
17
17
17
17
17
2222
21
20
19
18
17
17
17 18 19 20 21
21
21
18
18
19
20
19
20
22.0
'
22.
0
'
22.
0
'
22.
1
'
21.9'
21.9'
22.0'
21.8'
21.2'
2
1
.
8
'
20.8'
2
1
.
8
'
20.8'
2
1
.
7
'
20.9'
21.5'
21.5'
21.4'
21.6'
21.6'
21.5'
21.
7
'
21
.
7
'
21.7'
21.9'21.7'
21.6'
21.6'
21.5'
21.2'
2
0
.
3
'
20.2'
21.5'
20.5'
21.6'
21.6'
21.6'
21.6'
21.6'
21.8'21.8'
21.6'
21.8'
21.8'
21.6'
21.7'
21.8'
16.6'
17.0'
17.0'
16.9'
16.9'
16.9'21.9'
21.8'
22.0'
21.8'
21.3'
21.0'
16.9'
17.2'
16.6'
21.4'
16.9'
21.8'
17.1'21.4'
22.1'
17.0'
21.5'17.2'
21.5'
17.1'
21.2'
21.0'
17.2'
21.3'
17.0'
21.1'
16.3'
21.2'
21.5'
22.1'21.2'
20.7'
21.1'
19.2'
19.9'
20.3'
21.6'
21.5'
21.5'
17.9'
20.3'
18.1'19.8'
18.3'
20.2'
18.0'
20.3'
18.2'
20.4'
18.3'
20.5'
TW=21.6'
BW=20.8'
TW=21.7'
BW=20.6'
TW=21.7'
BW=20.5'TW=21.7'
BW=20.7'STORMWATER DETENTION
POND ECOBLOCK WALL
STORMWATER
DETENTION
POND
STORMWATER
DETENTION
POND
4' CLF
4' CLF22.0'
22
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
6' CLF
GATE
4' CLF
E/C
E/C
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
STORMDRAIN CULVERT END
STORMDRAIN CULVERT END
IE=17.82' 12" PVC NE
STORMDRAIN CULVERT END
IE=17.46' 12" PVC SW
SD
STORMDRAIN
CULVERT END
IE=17.13' 12" PVC SW
SANITARY SEWER
MANHOLE
W/ CONC. CHANNEL
RIM=21.61'
IE=14.61' 6" PVC N
IE=14.33' 8" PVC E
IE=14.06' 8" CONC. W
LADDER=NW
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SS
(
R
E
C
)
SS
(
R
E
C
)
SS
(
R
E
C
)
SD
SD
SD
SD
SD
SD
SD
IE=19.00' 8" PVC N
IE=18.79' 8" PVC SW
IE=19.15' 6" PVC W
SD
SD STORMDRAIN MANHOLE
TYPE II
RIM=20.35'
IE=14.80' 8" PVC E
8" STANDPIPE STRUCTURE
ON WEST SIDE
IE=14.80' 8" PVC W
TOP STANDPIPE=17.55'
BOTTOM STANDPIPE=13.85'
LADDER=N
STORMDRAIN MANHOLE
TYPE II
RIM=20.36'
IE=14.86' 8" S (FULL OF DIRT)
8" STANDPIPE STRUCTURE
ON WEST SIDE
IE=15.27' 8" PVC W
TOP STANDPIPE=17.81'
BOTTOM STANDPIPE=14.81'
LADDER=N
SANITARY SEWER
MANHOLE - FULL
OF WATER - NO
INVERTS FELT
RIM=21.35'
TOP WATER=20.01'
525.46'(C)
(R
I
C
E
A
V
E
N
U
E
)
LI
N
D
A
V
E
N
U
E
S
W
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
A/W
A/W
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNER
GATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
(THIRD AV
E
N
U
E
)
SW 13TH S
T
R
E
E
T
(
V
A
C
A
T
E
D
-
C
.
O
.
R
.
O
R
D
I
N
A
N
C
E
4
9
4
2
)
21.8'
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
1
1
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 9 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438812
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
SHEET MATCHLINE
SEE SHEET 13 OF 55 FOR CONTINUATION
12
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-11
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
TOPTOPTOPTOPTOP
TO
P
TO
P
TOP TOP TOP TOP TOP TOP TOP TOP TOP TOP TOP
TO
P
TOETOETOETOETOETOETOETOETOETOE
T
O
E
TOE TOE TOE TOE TOE TOE TOE TOE TOE TOE
TO
E
TO
P
TO
P
TOP TOP
TOP
TOP
T
O
E
TOE TOE\
\
P
S
D
S
D
21.9'
2
1
.
5
'
6' CLF
2222
21
20
19
18
17
18
18
19
20
19
20
19
19
20
21.8'
22.0'
21.8'
21.3'
16.9'
21.5'
21.6'21.9'
21.6'
21.4'
22.1'21.2'17.9'
18.1'
20.2'
19.8'
18.3'
18.1'
19.8'
18.0'
18.2'
20.4'
20.1'
18.3'
18.5'
20.3'
18.3'
20.5'
TW=21.7'
BW=20.4'TW=21.7'
BW=20.2'TW=21.7'
BW=20.1'TW=21.6'
BW=20.6'STORMWATER DETENTION
POND ECOBLOCK WALL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
0.7'
1.2'
4.4'
0.4'
STORMDRAIN CULVERT END
IE=18.16' 12" PVC NW
STORMDRAIN CULVERT END
IE=17.82' 12" PVC NE
79
8
.
8
4
'
(
C
)
INTERSTATE 405
6.2'
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
1
4
O
F
55 FO
R
C
O
N
T
I
N
U
A
T
I
O
N
SHEET MATCHLINE
SEE SHEET 12 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438813
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
13
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SV-12
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
P
IRR
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
TO
P
TO
P
T
O
E
\
\
P
P
P
P P P P P
PP
P
P P P P P P P P P P P P P P P P P
T
T
T
T
P
P
P
P
P
P
P
P
P
P
S
D
S
D
21
2
1
21
21
21
21
22
22
22
21
21
21
22
22 22
22
STEEL POST
FOR AERIAL
SUBARU SIGN
22.1'22.1'
22.0'
22.0'
22.0'
21.9'
22.0'
21.9'
21.6'
21.6'21.7'
21.8'
21.8'21.8'
20.9'20.9'
20.8'
21.1'
21.2'
21.7'
21.4'
2
1
.
5
'
20.7'
20.5'
20.3'
20.5'20.5'
21.2'
21.5'
21.2'
21.3'
21.2'6' CLF
6' CLF
6' CLF
6' CLF20.8'
21.2'
0.4'
S86°20'10"W
391.52'
INTERSTATE 405
0.7'
0.9'
1.0'
0.8'
4' CLF
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
0.6' FROM THE
CALCULATED LOT
CORNER
TAX PARCELS 3340404265 AND 3340404148
BOUNDARY AND TOPOGRAPHIC SURVEY DETAIL
SHEET MATCHLINE
SEE SHEET 11 OF 55 FOR CONTINUATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438814
McInnis
ENGINEERING &
SURVEY
1821 Dock Street, Suite 102Tacoma, Washington 98402
(253) 414-1992
www.mcinnisengineering.com
DERETSIGER
NO
T
G
NIHSAWFOETATS
L A R R Y O.WALKE
R
14
LINE IS 1" AT
FULL SCALE
FOR 22" X 34" SHEET
SCALE: 1" = 10'
10050 20
SH
E
E
T
M
A
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
1
3
O
F
55 F
O
R
C
O
N
T
I
N
U
A
T
I
O
N
SV-13
TE
D
-
4
0
-
4
3
8
8
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP GP
GP
GP
GP
G
P
GP
GP
GP
GP
GP
GP
GP
GP GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
RAMP
C/C
C/C
C/C
C/C
RAMP
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
C/C
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
E/CE/C
E/C
E/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART OF
SURVEY
(TAX PARCEL NO.
3340404150)
GATE
0.1'
4.9'
8.0'
6' CLF 7' CLF
6' CLF
6' CLF
6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
7.9' TALL CMU WALL
W/CANOPY
ASPHALT
CONTAINMENT
HUMP
E/C
E/C
E/C
E/C
5.1'
9.0'
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
GATE
GATE
6' CLF
7.9' TALL CMU WALL
W/CANOPY
E/C
E/C
E/C
E/C
6' CLF
6' CLF
6' CLF
STOP BAR
C/G
C/G
C/G
C/G
C/G
C/C
C/C
30.0'
DRIVEWAY
E/C
RA/W
RA/W
RA/W
RA/W
RA/W
RA/W
DUMPSTERCONC. PADAREA
ECOBLOCKS
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
CANOPY
(TYPICAL)
12"MAPLE
13"
MAPLE
12"
MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
STEEL POST
FOR AERIAL
SUBARU SIGN
E/C E/C
E/C
E/C
E/C
E/C
E/C
E/C
E/C
26.9'DRIVEWAY
C/G
C/G
GATE
RA/W
6' CLF
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
8"UNKNOWNDECIDUOUS
6"UNKNOWNDECIDUOUS
1X7" 1X6"
UNKNOWN
DECIDUOUS
1X6" 1X5"UNKNOWN
DECIDUOUS
STORMWATER DETENTIONPOND ECOBLOCK WALL
STORMWATER DETENTION
POND ECOBLOCK WALL
STORMWATER
DETENTION
POND
STORMWATER
DETENTION
POND
4' CLF
4' CLF
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
6' CLF
GATE
4' CLF
E/C
E/C
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
STORMDRAIN CULVERT END
IE=18.16' 12" PVC NW
STORMDRAIN CULVERT END
IE=17.82' 12" PVC NE
STORMDRAIN CULVERT END
IE=17.46' 12" PVC SW
SANITARY SEWER
MANHOLE
W/ CONC. CHANNEL
RIM=21.61'
IE=14.61' 6" PVC N
IE=14.33' 8" PVC E
IE=14.06' 8" CONC. W
LADDER=NW
STORMDRAIN CATCHBASIN
TYPE I
RIM=21.16'
IE=18.47' 8" PVC N
IE=18.37' 8" PVC NE
IE=18.18' 12" PVC SE
IE=18.25' 8" PVC NW
STORMDRAIN CATCHBASIN
TYPE I
RIM=20.93'
IE=18.91' 6" PVC NW
IE=18.68' 8" PVC SESTORMDRAIN CATCHBASIN
TYPE I
RIM=21.17'
IE=18.50' 8" PVC N
IE=18.90' 6" PVC NE
IE=18.44' 8" PVC SE
IE=18.98' 6" PVC W
SANITARY SEWER MANHOLE
OIL WATER SEPARATOR VAULT NORTH ACCESS LID
W/CONC. BAFFLE WALL UNDERNEATH
RIM=21.54'
BOTTOM VAULT NORTH OF BAFFLE WALL=13.7'
TOP OF CONC. BAFFLE WALL=17.84'
BOTTOM VAULT SOUTH OF BAFFLE WALL=13.4'
WATER LEVEL BOTH SIDES OF BAFFLE WALL=17.0'
NOTE: BOTTOM OF VAULT HAS HEAVY SLUDGE DEBRIS
AND NO PIPE SEEN HEADING TO THE NORTH TOWARDS
OBSERVED CLEANOUTS
SANITARY SEWER MANHOLE
OIL WATER SEPARATOR VAULT SOUTH ACCESS LID
W/CONC. BAFFLE WALL UNDERNEATH
RIM=21.41'
IE=17.18' 6" PVC W/OIL WATER SEPARATOR ELBOW SE
BOTTOM VAULT NORTH OF BAFFLE WALL=13.1'
TOP OF CONC. BAFFLE WALL=17.86'
BOTTOM VAULT SOUTH OF BAFFLE WALL=13.1'
WATER LEVEL BOTH SIDES OF BAFFLE WALL=17.0'
NOTE: BOTTOM OF VAULT HAS HEAVY SLUDGE DEBRIS
0.9'
1.0'
0.9'
UNKNOWN USECLEANOUT
RIM=21.61'
UNKNOWN USE
CLEANOUTRIM=21.65'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
SANITARY SEWER
MANHOLE - FULL
OF WATER - NO
INVERTS FELT
RIM=21.35'
TOP WATER=20.01'
525.46'(C)
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
0
L1
9
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
A/W
A/W
0.7'
0.9'
1.0'
0.8'
4' CLF
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNERGATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
EXISTING
BUILDING
FF: 21.95
1
1
1
2
2
2
2
FUTURE BUILDING OUTLINE,
ASPHALT SUB-GRADE TO
REMAIN WITHIN BUILDING LIMITS
3
3
4
4
PROTECT
HYDRANT
5
REMOVE
EXISTING FENCE
PROTECT EXISTING
CHAIN LINK FENCE
REMOVE EXISTING
ECOBLOCK WALL
PROTECT EXISTING
CHAIN LINK FENCE
PROTECT EXISTING
CHAIN LINK FENCEREMOVE
EXISTING FENCE
PROTECT EXISTING
CHAIN LINK FENCE
8
11
12
7
7
10
11
9
12
7
9
11
11
8
NEAT SAWCUT LINE (TYP.)
8
PROTECT EXISTING
STORM POND
CONTRACTOR TO POTHOLE AND
CONFIRM PIPE DEPTH PRIOR TO
CONSTRUCTION
REMOVE AND REPLACE
FENCE AS NECESSARY FOR
POWER IMPROVEMENTS
REMOVE AND REPLACE
VEGETATION AS
NECESSARY FOR POWER
IMPROVEMENTS
REFER TO PSE PLANS FOR
NEW POLE INSTALLATION
REFER TO PSE
PLANS FOR
NEW POLE
INSTALLATION
13
13
REFER TO PSE PLANS FOR
POWER RELOCATION AND
RECONNECTION
PROTECT EXISTING
BUSINESS SIGN
REFER TO PSE PLANS FOR
REMOVAL OF EXISTING
POWER POLE
REFER TO PSE PLANS FOR
REMOVAL OF EXISTING
POWER POLE
PROTECT EXISTING
FENCING
CLEARING LIMIT
4
PROTECT
EXISTING
POLE
PROTECT
EXISTING
UTILITIES
REMOVE EX FDC
AND EX 4" FIRE
LINE TO BLDG
REMOVE EXISTING
FENCING
12
12
PROTECT EXISTING
WATER METER AND
SERVICE LINE
PROTECT EXISTING
IRRIGATION METER
AND SERVICE LINE
10
CAP EXISTING
SEWER AT
PROPERTY LINE
2
REMOVE 8" SEWER
AND PLUG AT
MANHOLE ONCE
NEW BUILDING
SERVICE IS ONLINE
SEE EXISTING FIRE
SPRINKLER NOTE
L15
GP GP
GP
GP
P
GP
23.9'
DRIVEWAY
C/C ASPHALT
RAMP
C/G
C/G
E/C
A/W
GATE
GATE
0.1'
4.9'
6' CLF 7' CLF
7' CLF
0.2'
0.3'
6' CLF
14.4'
0.1'
UNKNOWN USE
CLEANOUT
RIM=21.96'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L16
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
15
SITE DEMOLITION PLAN C1.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
D
E
M
O
.
d
w
g
KEYNOTES
REMOVE EXISTING CATCH BASIN1
EXISTING UTILITY MAIN TO BE ABANDONED IN PLACE.
CONTRACTOR TO COORDINATE WITH GEOTECHNICAL
ENGINEER FOR ALL PIPES PLANNED TO BE
ABANDONED UNDER BUILDING FOUNDATION.
2
PROTECT PORTION OF WATER MAIN TO
REMAIN.3
PROTECT STORM WATER PIPE TO REMAIN.4
PROTECT PORTION OF SEWER MAIN TO
REMAIN.
5
PROTECT PORTION OF SEWER MAIN TO
REMAIN.
6
EXISTING FIRE SPRINKLER NOTE
EXISTING FIRE SPRINKLER TO BE MAINTAINED UNTIL NEW FIRE SYSTEM IS
OPERATIONAL. CONTRACTOR TO COORDINATE SEQUENCING WITH RRFA AND COR
WATER UTILITY DURING DEMOLITIONS AND VERTICAL CONSTRUCTION.
DEMO LEGEND
TREE TO BE REMOVED
TREE TO BE RETAINED
REMOVE EXISTING ASPHALT
REMOVE EXISTING CONCRETE
RETAIN EXISTING ASPHALT
RETAIN EXISTING CONCRETE
REMOVE EXISTING LIGHT POLE7
PROTECT EXISTING LIGHT POLE, POWER TO BE RECONNECTED
AFTER OVERHEAD POWER HAS BEEN PLACED UNDERGROUND
8
REMOVE SECTION OF WATER MAIN TO ACCOMMODATE NEW
UTILITY IMPROVEMENTS, SEE EXISTING FIRE SPRINKLER NOTE.
9
REMOVE SECTION OF SEWER MAIN TO
ACCOMMODATE NEW UTILITY IMPROVEMENTS
10
REMOVE SECTION OF STORM PIPE TO
ACCOMMODATE NEW UTILITY IMPROVEMENTS
11
REMOVE LANDSCAPE TREES12
REMOVE EXISTING IRRIGATION LINE13
REMOVE EXISTING POWER (OR ABANDON IN
PLACE)
14
14
14
DEMO CHAINLINK FENCE
DEMO POWER LINE
DEMO WATER LINE
DEMO SEWER LINE
DEMO OVERHEAD UTILITY
REMOVE ECO BLOCK WALLS
TOP OF SLOPE LINE
TOE OF SLOPE LINE
P
SS
OHU
TOP
TOE
R-438815
MATCHLINE,
SEE SHEET C1.1
MATCHLINE,
SEE SHEET C1.1
DEMO EXISTING GATE
SEE SHEET CR1.1
FOR OFFSITE DEMO
AND IMPROVEMENTS
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
RAMP
C/C
C/C
C/C
C/C
RAMP
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
E/CE/C
E/C
E/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART OF
SURVEY
(TAX PARCEL NO.
3340404150)
0.1'
4.9'
8.0'
6' CLF
6' CLF6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
E/C
E/C
E/C
E/C
5.1'
9.0'
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
GATE
E/C
E/C
6' CLF
6' CLF
6' CLF
STOP BAR
C/G
C/G
C/G
C/G
C/G
30.0'
DRIVEWAY
E/C
RA/W
RA/W
RA/W
RA/W
RA/W
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
CANOPY
(TYPICAL)
12"MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
STEEL POST
FOR AERIAL
SUBARU SIGN
26.9'DRIVEWAY
C/G RA/W
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
4' CLF
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
0.9'
1.0'
0.9'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
525.46'(C)
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
0
L1
9
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
A/W
A/W
0.7'
0.9'
1.0'
0.8'
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNERGATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
EXISTING
BUILDING
FF: 21.95
FUTURE
BUILDING
OUTLINE
FUTURE
BUILDING
OUTLINE
22.00
22.00
22.0
0
22.00
22
.
0
0
22.00
23.0
0
23.00
23
.
0
0
22.00
22.0022.00
21.00
21
.
0
0
23
.
0
0
PROTECT EXISTING
STORM POND
CONTRACTORS TO STABILIZE
ALL DISTURBED PORTIONS
OF THE SITE USING SEED,
MULCH, OR OTHER
ENGINEER APPROVED BMP
IP (TYP.) AFTER CB
INSTALLATION
SF
CL
CL
WATER QUALITY STRUCTURE SHALL
NOT HAVE ANY SOIL MEDIA INSTALLED
PRIOR TO FULL SITE STABILIZATION
AND SHALL BE CLEANED PRIOR TO
SOIL INSTALLATION
NO STAGING,
CONSTRUCTION PARKING
OR STOCKPILING OFFSITE
OR IN PUBLIC ROW.
ID
CD
MAINTAIN ACCESS TO GATE FOR
NEIGHBORING PROPERTY OWNER DURING
CONSTRUCTION OR HAVE AN AGREEMENT
IN PLACE THAT ALLOWS FOR ACCESS TO
BE CLOSED.
REMOVE
TREE
REMOVE
TREE
REMOVE
TREE
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
TESC LEGEND
16
TEMPORARY EROSION AND
SEDIMENT CONTROL PLAN
C1.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
T
E
S
C
.
d
w
g
INLET PROTECTION
SILT FENCE
(MAINTAIN EXISTING)
CLEARING LIMITS
CONSTRUCTION ENTRANCE
(MAINTAIN EXISTING)
INTERCEPTOR DITCH
CHECK DAM
TREE PROTECTION FENCING
CL
SF
IP
CE
SAWCUT LINE
CE
CE
EROSION CONTROL AND SEDIMENT CONTROL (ESC) FACILITIES SHALL NOT BE ALLOWED TO FALL INTO
DISREPAIR. ALL ESC FACILITIES SHALL BE INSPECTED AS A MINIMUM, ACCORDING TO THE FOLLOWING
SCHEDULE:
DRY SEASON: ONCE A WEEK
WET SEASON: DAILY, AND AFTER EVERY RAINFALL EVENT PRODUCING RUNOFF.
NEEDED REPAIRS SHALL BE MADE WITHIN 24 HOURS OR IMMEDIATELY IF POSSIBLE.
INSPECTION SCHEDULE FOR ESC FACILITIES
3
C1.3
2
C1.3
4
C1.3
THE WALKER'S RENTON SUBARU SERVICE DEPARTMENT EXPANSION SITE PLAN
REVIEW, CONDITIONAL USE PERMIT, AND MODIFICATION, FILE NO. LUA25-000171,
ECF, CU-A, SA-A, MOD, AS DEPICTED IN EXHIBIT 3, IS APPROVED AND IS SUBJECT
TO THE FOLLOWING CONDITIONS:
1.THE APPLICANT SHALL COMPLY WITH THE THREE (3) MITIGATION MEASURES
INCLUDED AS PART OF THE DETERMINATION OF NON-SIGNIFICANCE -
MITIGATED (DNS-M) ISSUED BY THE RENTON ENVIRONMENTAL REVIEW
COMMITTEE ON JULY 7, 2025.
a.THE PROJECT CONSTRUCTION SHALL COMPLY WITH THE
RECOMMENDATIONS FOUND IN THE GEOTECHNICAL ENGINEERING REPORT,
PREPARED BY MIGIZI GROUP AND DATED DECEMBER 11, 2024, OR FUTURE
ADDENDA.
b.THE APPLICANT’S GEOTECHNICAL ENGINEER SHALL REVIEW THE FINAL
CONSTRUCTION AND BUILDING PERMIT PLANS TO VERIFY CONSISTENCY
WITH THE REPORT RECOMMENDATIONS. A STAMPED LETTER SHALL BE
PROVIDED TO THE CITY CONFIRMING THAT THE PLANS MEET THE INTENT OF
THE GEOTECHNICAL RECOMMENDATIONS.
c.THE APPLICANT SHALL SAMPLE SOIL FOR ARSENIC AND LEAD
FOLLOWING THE 2019 TACOMA SMELTER PLUME GUIDANCE. IF LEAD OR
ARSENIC ARE FOUND AT CONCENTRATIONS ABOVE THE MODEL TOXICS
CONTROL ACT (MTCA) CLEANUP LEVEL, CONSTRUCTION WORKERS AND
EMPLOYEES ON-SITE SHALL BE NOTIFIED OF THEIR OCCURRENCE.
2.THE APPLICANT SHALL SUBMIT A REVISED SITE PLAN WITH THE BUILDING
PERMIT APPLICATION THAT IDENTIFIES ONE (1) OR MORE REFUSE AND
RECYCLABLES ENCLOSURES COMPLIANT WITH THE SIZE REQUIREMENTS IN
RMC 4-4-090E.3 OR OBTAIN MODIFICATION APPROVAL TO REDUCE THE
MINIMUM SIZE REQUIREMENT. THE REFUSE AND RECYCLING ENCLOSURE(S)
SHALL BE SIZED BASED ON THE COMBINED SQUARE FOOTAGE OF BOTH
DEALERSHIPS TO ENSURE ADEQUATE SPACE IS PROVIDED. THE REVISED
SITE PLAN OR MODIFICATION SHALL BE REVIEWED AND APPROVED BY THE
CURRENT PLANNING PROJECT MANAGER PRIOR TO BUILDING PERMIT
APPROVAL.
3.THE APPLICANT SHALL PROVIDE DETAILED PLANS FOR A MINIMUM OF SIX (6)
BICYCLE PARKING SPACES MEETING THE STANDARDS OF RMC 4-4-080F.11.
THE DESIGN, SPECIFICATIONS, AND PLACEMENT OF THE BICYCLE PARKING
SPACES SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE
CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION
PERMIT ISSUANCE.
4.THE APPLICANT SHALL SUBMIT A REVISED LANDSCAPE PLAN IDENTIFYING
ON-SITE LANDSCAPING THAT TOTALS A MINIMUM OF TWO AND ONE-HALF
PERCENT (2.5%) OF THE SITE AREA. THE REVISED LANDSCAPE PLAN SHALL
BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT
MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE.
5.THE APPLICANT SHALL SUBMIT A LIGHTING PLAN THAT DEMONSTRATES
COMPLIANCE WITH RENTON MUNICIPAL CODE AND PROVIDE ENOUGH LIGHT
FOR SAFETY BUT DOES NOT PROVIDE EXCESSIVE LIGHT ACROSS THE SITE
THAT WOULD IMPACT ADJACENT PROPERTIES AT THE TIME OF
CONSTRUCTION PERMIT REVIEW.
CONDITIONS OF APPROVAL
R-438816
TEMPORARY SEDIMENT TRAP
MIN SURFACE AREA: 1501 SF
TOP POND: 21.0
6' WIDE SPILLWAY: 20.0
BOTTOM POND: 17.5
USE EXISTING BIOSWALE AS TEMPORARY SEDIMENT
TRAP. BIOSWALE OUTLET TO BE PLUGGED/REMOVED
PRIOR TO CONSTRUCTION RUNOFF BEING DIRECTED
INTO THE SEDIMENT TRAP.
CONCRETE WASHOUT
AREA, CONTRACTOR TO
PROVIDE CONCRETE
WASHOUT AS NECESSARY
ID
CD
2
C1.4
3
C1.4
TP 4
C1.4
TP(TYP.)
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
17
TESC NOTES AND DETAILS C1.3Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
T
E
S
C
-
D
E
T
L
.
d
w
g
1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS,
A PRE-CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY
OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT,
AND THE APPLICANT’S CONTRACTOR.
2.THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON
STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION
STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE
PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL
MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH
THE CONSTRUCTION STORMWATER GENERAL PERMIT.
3.THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION
SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE
FOLLOWED FROM THE PRE-CONSTRUCTION MEETING TO
POST-PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC
REQUIREMENTS.
4.THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND
THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND
TREE RETENTION, AS PRESCRIBED ON THE PLAN(S), SHALL BE
CLEARLY FLAGGED BY SURVEY TAPE OR FENCING AND PROTECTED
IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF
RENTON SURFACE WATER DESIGN MANUAL (RSWDM) PRIOR TO
CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO
DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE
PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE
APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
5.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT
THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE
DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS
CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE
REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN
AND TRACK-OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR
THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED
OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE
END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER,
AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS
OF THE STATE.
6.WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED
OFF-SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY.
DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO
STORM DRAINS OR OPEN DITCHES. ON-SITE DUMPING OF EXCESS
CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE
WASHOUT AREAS.
7.ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN
OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO
PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER,
DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS
SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH
TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND
POTENTIAL FOR ON-SITE EROSION HAS PASSED. ALL ESC BMPS
SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND
THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR
ON-SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION,
MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF
ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8.ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE
POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF
PROPERLY.
9.THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE
MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS.
AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL
CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT
MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE
SILTATION CONTROL ON THE PROPOSED SITE. DURING THE
COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND
RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW
CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO
PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT
PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE
SYSTEM.
10.APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT
CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE
NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR
STORMWATER FACILITIES.
11.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION
OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY
FOR REVIEW AND APPROVAL.
12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY
EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS
DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH)
OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH
SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE
APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING,
PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF
THE RSWDM.
13.WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION
SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS
OTHERWISE APPROVED BY THE CITY.
14.ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING
IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7)
DAYS.
15.THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND
MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS
FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE
SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY.
16.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY,
CATCH BASIN INSERTS PER THE CITY STANDARD PLANS SHALL BE
PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN
500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE
RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A
SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE
PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO
ENSURE FULLY FUNCTIONING CONDITION.
17.AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE
CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND
CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE
CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN WATER
INTO THE DOWNSTREAM SYSTEM.
18.ANY PERMANENT STORMWATER FACILITY USED AS A TEMPORARY
SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC
BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE
PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN
INFILTRATION SYSTEM, THE TEMPORARY FACILITY SHALL BE ROUGH
GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE
FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY.
19.AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING
STORMWATER FACILITIES OR ON-SITE BMPS (AMENDED SOILS,
BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY
FENCED AND PROTECTED USING ESC BMPS TO AVOID
SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20.PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST),
ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH
ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE
WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED
WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN
EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE
AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY
FOR REVIEW.
21.PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE
SHALL BE STABILIZED TO PREVENT SEDIMENT-LADEN WATER FROM
LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED,
AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND
ON-SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING
CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE
VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A
MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND
MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP
SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS
ADEQUATE FOR SMALL AREAS TO BE LANDSCAPED BEFORE
OCTOBER 1ST.
22.ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK
STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE
CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN
CITY ROAD RIGHT-OF-WAY SHALL BE CONSTRUCTED IN
ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF
ROAD RIGHT-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE INTERNATIONAL BUILDING CODE.
EROSION CONTROL (ESC) STANDARD PLAN NOTES (PER COR STD 268.00)
1 PLASTIC COVERING 2 SILT FENCE 3 STABILIZED CONSTRUCTION ENTRANCE 4 CATCH BASIN INSERT
R-438817
CONSTRUCTION SEQUENCE
1.SURVEY AND FLAG CLEARING LIMITS.
2.SCHEDULE AND ATTEND PRECONSTRUCTION MEETING WITH CITY OF RENTON.
3.PROVIDE MISC. DEMOLITION AND CLEAR AND GRUB AREA WITHIN CLEARING
LIMITS REQUIRED FOR INSTALLATION OF TEMPORARY EROSION CONTROL
FACILITIES. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHOWN ON THE
EROSION CONTROL PLAN SHALL BE INSTALLED PRIOR TO, OR AS A FIRST STAGE
OF SITE PREPARATION.
4.PROVIDE CONSTRUCTION ENTRANCE, SILT FENCE, AND CATCH BASIN INLET
PROTECTION AS SHOWN ON SHEET C1.2.
5.THE CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES WEEKLY AND
PROVIDE REPAIRS AS NEEDED.
6.PROVIDE COVER MEASURES TO INCLUDE ARMORING, MULCHING AND
HYDROSEEDING TO STABILIZE DENUDED AREAS AND PREVENT THE TRANSPORT
OF SEDIMENT-LADEN STORMWATER OFF-SITE.
7.PROVIDE STORM SYSTEM, SANITARY SYSTEM, WATER AND MISCELLANEOUS
UTILITIES AS SHOWN ON THE PLANS. PROVIDE 6" VERTICAL AND 7' HORIZONTAL
CLEARANCE (OUTSIDE SURFACES) BETWEEN STORM DRAIN LINES AND OTHER
UTILITY PIPES AND CONDUITS.
8.PROVIDE CATCH BASIN SEDIMENT PROTECTION ON ALL CATCH BASINS.
9.FINE GRADE SITE AND PAVE. COORDINATE WITH THE CITY FOR REQUIRED
INSPECTIONS.
10.REMOVE SEDIMENT FROM STORM PIPES AND CATCH BASIN SUMPS.
11.STABILIZE ALL REMAINING DISTURBED AREAS.
12.COORDINATE WITH THE CITY OF RENTON FOR FINAL INSPECTION.
13.REMOVE REMAINING TEMPORARY EROSION CONTROL DEVICES WHEN AREA HAS
BEEN PERMANENTLY STABILIZED WITH VEGETATION AND REMOVAL IS
APPROVED BY THE CITY.
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
18
TESC NOTES AND DETAILS
CONT.
C1.4Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
T
E
S
C
-
D
E
T
L
.
d
w
g
10. SEED SHALL NOT BE USED IN AREAS SUBJECT TO WEAR BY CONSTRUCTION TRAFFIC.
3. APPLICATION TO BE 100 LBS/ACRE.
SEDIMENT BASINS.
AND WETLANDS.
6. FOR SEED BEDS PLANTED BETWEEN OCTOBER 31 AND APRIL 30, ARMORING OF THE
7. BEFORE SEEDING, INSTALL NEEDED SURFACE RUNOFF CONTROL MEASURES SUCH
8. THE SEEDBED SHALL BE FIRM WITH A FAIRLY FINE SURFACE, FOLLOWING SURFACE
9. FERTILIZERS ARE TO BE USED ACCORDING TO SUPPLIERS RECOMMENDATIONS.
5. SEED BEDS PLANTED BETWEEN MAY 1 AND OCTOBER 31 WILL REQUIRE IRRIGATION
4. 500 LBS/ACRE 10-20-20 FERTILIZER, 2000 LBS/ACRE WOOD FIBER CELLULOSE AND
AND OTHER MAINTENANCE AS NECESSARY TO FOSTER AND PROTECT THE ROOT
SEED BED WILL BE NECESSARY. (E.G., GEOTEXTILES, JUTE MAT, CLEAR PLASTIC
AS GRADIENT TERRACES, INTERCEPTOR DIKES, SWALES, LEVEL SPREADERS AND
ROUGHENING. PERFORM ALL OPERATIONS ACROSS OR AT RIGHT ANGLES TO THE
AMOUNTS USED SHOULD BE MINIMIZED, ESPECIALLY ADJACENT TO WATER BODIES
40 LBS/ACRE SOIL BINDER OR TACKING AGENT TO BE APPLIED WITH SEED MIXTURE.
COVERING.)
SLOPE.
STRUCTURE.
NOTES" ON THIS SHEET.
HYDROSEEDING NOTES:
2. HYDROSEEDING TO BE THE FOLLOWING MIXTURE:
1. HYDROSEEDING SHALL BE APPLIED IN ACCORDANCE WITH THE "EROSION CONTROL 1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND
SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. (MIN. 2"
THICK)
2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED
SLOPES GREATER THAN 2:1.
3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR
IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE
SEASON.
4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY
NOVEMBER 1.
MULCHING NOTES:
R-438818
1 SEDIMENT TRAP 2 INTERCEPTOR SWALE 3 DITCH CHECK DAMS
4 TREE PROTECTION
1.FROM OCTOBER 1ST THROUGH APRIL 30TH, NO SOILS SHALL
BE EXPOSED FOR MORE THAN TWO CONSECUTIVE WORKING
DAYS. THIS TWO-DAY REQUIREMENT MAY BE APPLIED AT
OTHER TIMES OF THE YEAR IF STORM EVENTS WARRANT
MORE CONSERVATIVE MEASURES.
2.EXPOSED SOILS SHALL BE STABILIZED AT THE END OF THE
WORKDAY PRIOR TO A WEEKEND, HOLIDAY, OR PREDICTED
RAIN EVENT.
3.A WEEKLY MAINTENANCE REPORT IS REQUIRED TO BE
SUBMITTED TO CED.
WET SEASON NOTES:
1.PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE
REQUIREMENTS OF THE STATE STANDARD SPECIFICATIONS SECTION 9-14.5.
2.COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR
TIRES ON ROPES WITH A MAXIMUM 10-FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS
SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHALL BE AT LEAST A 12 INCH
OVERLAP OF ALL SEAMS.
3.CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN
NOVEMBER 1 AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED.
4.WHEN THE COVERING IS USED ON UN-SEEDED SLOPES, IT SHALL BE KEPT IN PLACE UNTIL THE
NEXT SEEDING PERIOD.
5.PLASTIC COVERING SHEET SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO
PREVENT SURFACE WATER FLOW BENEATH SHEETS.
6.PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS.
PLASTIC COVERING NOTES:
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
GP
GP
GP
GP
GP
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
G
PGP
GP
GP
GP
GP
GP
P
GP
GP
GP
GP
P
GP
GP
GP
GP
GP
GP
GP
N77°27'44"
E
9
8
8
.
6
6
'
(
C
)
S0
1
°
2
7
'
1
4
"
W
3
0
0
.
8
4
'
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
S0
1
°
2
1
'
0
3
"
W
1
0
7
6
.
5
8
'
(
M
)
525.46'(C)
30
'
3
0
'
30'30'
16
'
1
6
'
16
'
80'
80'
80'80'
90'90'
N0
1
°
2
6
'
1
4
"
E
10
9
.
1
8
'
237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L16
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L13
L8
L1
2
L9
L1
0
L11
L6
L4
L3
L2
L5
L7
L1
L1
9
GP
GP
P
C
C
10
9
.
2
0
'
8'
75
.
2
0
'
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
N1
°
2
2
'
4
6
"
E
33
0
.
0
8
'
N77° 27' 44
"
E
117.47'
S1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77° 26' 10
"
E
119.92'
N1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
N77° 27' 44
"
E
29.98'
N77° 27' 4
4
"
E
63.89'
S9
°
3
9
'
1
5
"
E
1
0
5
.
0
4
'
S77° 26' 1
0
"
W
84.61'
N1
°
2
2
'
4
3
"
E
10
8
.
1
2
'
S1
°
2
2
'
4
3
"
W
10
8
.
1
2
'
S8
°
5
7
'
1
5
"
E
6
0
.
1
2
'
N77° 24' 3
8
"
E
123.29'
S1
°
2
1
'
0
3
"
W
11
4
.
3
4
'
S86° 20' 10"W
391.52'
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
LI
N
D
A
V
E
S
W
SW 13TH
S
T
INTERSTATE 405
FOUND ENCASED IN LEAD 1 7/8" BRASS DISK
W/PUNCH 0.9' BELOW CASE RIM HELD FOR THE
CENTERLINE ALIGNMENT OF LIND AVENUE SW ONLY
VISITED 11/04/2024
FOUND TACK IN LEAD SET CONCRETE BASE,
1.0' BELOW ROAD GRADE. HELD FOR THE
CENTERLINE INTERSECTION OF SW 12TH
STREET AND RAYMOND AVENUE.
VISITED 11/04/2024
FOUND 1/2" REBAR AND CAP STAMPED
"LS19635". REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER.
VISITED 11/18/2024
FOUND 1/2" REBAR AND CAP, 0.3' BELOW
ROAD GRADE. HELD FOR THE CENTERLINE
INTERSECTION OF SENECA AVENUE SW
AND SW 13TH STREET.
VISITED 11/04/2024 BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
BLDG
ADDITION
18' (TYP)9' (TYP)
16' (TYP)
9' (TYP)
18' (TYP)
9' (TYP)
8' (TYP)
18' (TYP)
18' (TYP)
8' (TYP)
18' (TYP)
9' (TYP)
TRASH ENCLOSURE
WHEEL STOP (TYP)
X
VC
VC
X
NC
EC
NC
EC
NC
VC
FC
X
PROVIDE NEW FENCE
SECTION TO ENCLOSE POND.
MATCH EXISTING FENCE
TYPE, MATERIAL AND HEIGHT.
EMERGENCY VEHICLE ACCESS
SEE NOTE 8
R45.00'
R25.00'
R25.00'
R45.00'
R25.00'
R45.00'
20.00'
20.00'CURBING INSTALLED
MINIMUM 2.0' FROM
EDGE OF POLE. SEE
FRONTAGE PLANS.
BICYCLE PARKING. REFER
TO ARCHITECTURAL PLANS
FOR ADDITIONAL DETAILS.
EMERGENCY VEHICLE ACCESS
SEE NOTE 8
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
19
SITE PLAN AND HORIZONTAL
CONTROL
C2.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
I
T
E
-
P
L
A
N
.
d
w
g
CONCRETE SURFACING
ASPHALT SURFACING
(STANDARD DUTY)
EXTRUDED CURB
NO CURB
EC
NC
1.REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL SITE
DETAILS INCLUDING STRIPING, CONCRETE SCORING, AND
TRASH ENCLOSURE DETAILS.
2.REFER TO ARCHITECTURAL PLANS FOR DISPLAY PARKING VS
STRIPED CUSTOMER PARKING
3.CAD FILE IS AVAILABLE TO ASSIST WITH HORIZONTAL SITE
LAYOUT
4.REFER TO LANDSCAPE PLANS FOR TOPSOIL, SEEDING, AND
PLANTING REQUIREMENTS.
5.PROVIDE EXTRUDED CURB AT ALL PARKING LOT ISLANDS
6.ALL DIMENSIONS ARE TO FACE OF CURB
7.CONTRACTOR TO COORDINATE FIRE ACCESS REQUIREMENTS,
SEQUENCING, HYDRANT SHUT OFFS DURING WATER MAIN
CONSTRUCTION WITH RRFA AND COR WATER UTILITY DURING
DEMOLITIONS AND VERTICAL CONSTRUCTION.
8.LIMITS OF EMERGENCY VEHICLE ACCESS TO BE STRIPED WITH
HIGH-VISIBILITY RED OR YELLOW PAINT.
"NO PARKING - FIRE LANE" TO BE PAINTED ON ASPHALT AT 50'
INTERVALS.
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE,
GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE
INTERSECTION OF LIND AVE. SW AND SW 16TH ST., BEING CITY OF
RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK, BEING CITY OF RENTON CONTROL ID. 1891,
RESPECTIVELY.
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY
THE CITY OF RENTON PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND)
WAS HELD AT CITY OF RENTON CONTROL ID. 1895
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
BASIS OF BEARING
HORIZONTAL DATUM
VERTICAL DATUM
SURFACING LEGEND
GENERAL NOTES
VERTICAL CURBVC
CHANGE CURB TYPE / END CURBX
5
C2.2
1
C2.2
3
C2.2
4
C2.2
6
C2.2
R-4388019
R45.00'
R25.00'
R45.00'
R25.00'
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
20
SURFACING DETAILS C2.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
I
T
E
-
P
L
A
N
.
d
w
g
2"
4"
NOTES:
1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS.
2.THE CONTRACTOR SHALL EXPOSE EXISTING SUBGRADE, PROOF
ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE
ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH
IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL
REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL
ENGINEER.
CRUSHED SURFACING
BASE COURSE PER
WSDOT 9.03-9(3)
HMA CLASS 1/2", PG 64-22
6"10"
5"2.5"CURB, WSDOT SPEC.
8-04
CEMENT CONCRETE
FOR FILL BEHIND CURBS
SEE LANDSCAPE PLAN
6"
2.5"CUT/SAWED JOINT
BOTTOM OF
@ 15' INTERVAL
1"
NOTE
CONSTRUCTION SHALL
CONFORM TO WSDOT
SPECIFICATION 8-04.3.
24" MIN. DEPTH STRUCTURAL
FILL COMPACTED TO 95%
8"
12"
PAVEMENT
(ON-SITE ONLY)(ON-SITE ONLY)
(ON-SITE ONLY)
7 3/4"
1" R
6"
1'
-
4
"
1/
2
"
5 1/2"
NOTE
CONSTRUCTION SHALL CONFORM
TO WSDOT SPEC. 8-04.3
FINISH GROUND GRADE
PAVEMENT
ATTACHMENT DETAIL
ELEVATION
PLAN
NOTES:
1.THE NON-SHRINK GROUT USED TO
ATTACH THE PRECAST CURB SHALL
CONSIST OF 3:1 SAND AND CEMENT.
GROUT TO A DEPTH OF 1" FROM THE
TOP OF THE BUMPER.
2.LOCATIONS FOR WEEPHOLES, AND
V-SLOTS SHALL BE IDENTIFIED ON
THE DELIVERY ORDER DRAWINGS.
3.CONCRETE SHALL HAVE A
COMPRESSIVE STRENGTH OF 3000
PSI AT 28 DAYS.
13/16" DIA. HOLES9"
6'
2" CLR (TYP)
6"
5"
2 1/2"2 1/2"
6"
10"
#3 BARS (2)
NON-SHRINK
GROUT
18" MIN
#6 BAR (2)
#3 BARS (2)
1 NOT TO SCALE
EXTRUDED CURB 2 NOT TO SCALE
FLUSH CURB 3 NOT TO SCALE
VERTICAL CURB
4 NOT TO SCALE
STANDARD PAVEMENT SECTION
5 NOT TO SCALE
WHEEL STOP
PER PLAN
1/4" EDGED GROOVE
COMPACTED SUBGRADE
1.SUBGRADE COMPACTION FOR CONCRETE CURB AND WALKS SHALL
BE 95% OF MAXIMUM DENSITY.
2.EXPANSION JOINTS CONSISTING OF 3/16" BY 2" PREMOLDED JOINT
MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS; AT DRIVEWAY
RETURNS; AND AROUND ALL UTILITY POLES, METER BOXES, ETC. IN
SIDEWALKS.
3.PROVIDE WELDED WIRE MESH (4x4 W1.7/W1.7) IN ALL AREAS
SUBJECT TO VEHICLE LOADING.
NOTES:
4" CEMENT CONCRETE SIDEWALK (CLASS 3000)
2" CRUSHED SURFACING TOP COURSE PER
WSDOT STANDARD SPECIFICATION 9-03.9(3)
6 NOT TO SCALE
CEMENT CONCRETE SECTION (ON-SITE ONLY)
FINISH GRADE AT BACK OF
CURB TO BE AT SAME
HEIGHT AS PAVEMENT
R-438820
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
RAMP
C/C
C/C
C/C
C/C
RAMP
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
E/CE/C
E/C
E/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART OF
SURVEY
(TAX PARCEL NO.
3340404150)
0.1'
4.9'
8.0'
6' CLF
6' CLF6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
E/C
E/C
E/C
E/C
5.1'
9.0'
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
GATE
E/C
E/C
6' CLF
6' CLF
6' CLF
STOP BAR
C/G
C/G
C/G
C/G
C/G
30.0'
DRIVEWAY
E/C
RA/W
RA/W
RA/W
RA/W
RA/W
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
CANOPY
(TYPICAL)
12"MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
STEEL POST
FOR AERIAL
SUBARU SIGN
26.9'DRIVEWAY
C/G RA/W
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
4' CLF
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
0.9'
1.0'
0.9'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
525.46'(C)
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
1
0
5
.
0
4
'
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
0
L1
9
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
A/W
A/W
0.7'
0.9'
1.0'
0.8'
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNERGATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
A
C3.2
B
C3.2
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
EG: 22.00 EG: 21.99 EG: 21.95
EG: 21.75
EG: 20.67
EG: 20.43
GRADING LIMITS
BLDG ADDITION
FF: 21.95
HP: 21.67
FG: 21.95
FG: 21.95
FG: 21.95
FG: 21.95
4
.
1
6
%
2.
2
6
%
3.92%
1.66%
3.44%
3.00%
1.39%
1
.
6
5
%
0.9
5
%
2
.
7
0
%
FG: 21.95 HP: 21.81
HP: 21.76
HP: 21.8221.50
21.7
5
21.75
21.75
22.00
21
.
7
5
22
.
0
0
22.
2
5
22
.
5
0
22.
7
5
20
.
7
5
2
1
.
0
0
2
1
.
2
5
2
1
.
5
0
2
1
.
7
5
1
.
7
9
%
EXISTING
BUILDING
FF: 21.95
BLDG
ADDITION
1.1
8
%
1.30%
1.7
2
%
EG: 21.40
21.00
22.00
21.75
22.0
0
22.25 22.50 22.75 23.00
FG: 22.08
FG: 23.21
FG: 23.04
FG: 23.04
FG: 22.64
FG: 22.24
FG: 22.17
FG: 21.80
0.45%
1
.
0
5
%
2.33%
0.58
%
1.1
2
%
2.14%
1.84%
22
.
0
0
23
.
0
0
CB #8
RIM: 22.93
CB #4
RIM: 21.60
CB #2
RIM: 21.60
CB #3
RIM: 21.60
CB #1
RIM: 21.59
CB #5
RIM: 21.66
CB #6
RIM: 21.40
EXIST. CB1
RIM: 21.31
EXIST. CB3
RIM: 21.20
CB #7
RIM: 21.17
EXIST. CB2
RIM: 21.46
EXIST. CB4
RIM: 21.20
FLOWLINE
FG: 21.85
FG: 21.80
EG: 21.57
EG: 21.75EG: 21.66FG: 21.81
FG: 22.12
FG: 21.16
FG: 21.69
???
38.31%
EG: 21.50
EG: 21.73
FG: 20.92
EG: 21.46
EG: 21.36
EG: 21.26
FG: 21.91
FG: 21.80
FG: 21.90 FG: 21.82
FG: 21.81
FG: 21.74
FG: 21.20
FG: 21.78
RIDGE
LINE
FG: 21.95
FG: 21.80
AREA DRAIN
RIM: 21.64
FG: 21.20
FG: 21.65
FG: 21.92
EG: 22.06
22.
2
5
22
.
0
0
21
.
2
5
1.1
1
%
1
.
4
5
%
FG: 21.90
FG: 21.81
FG: 21.55
EG: 21.59
EG: 21.52
EG: 21.39 EG: 21.41
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE,
GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE
INTERSECTION OF LIND AVE. SW AND SW 16TH ST., BEING CITY OF
RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK, BEING CITY OF RENTON CONTROL ID. 1891,
RESPECTIVELY.
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY
THE CITY OF RENTON PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND)
WAS HELD AT CITY OF RENTON CONTROL ID. 1895
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
PROJECT PRIMARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1895
PUBLISHED ELEVATION: 25.702' NAVD 88
DESCRIPTION:
ENCASED 3" BRASS DISK W/PUNCH LOCATED AT THE INTERSECTION OF
LIND AVE. SW AND SW 16TH ST.
PROJECT SECONDARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1891
PUBLISHED ELEVATION: 24.1568' NAVD 88
OBSERVED ELEVATION: 24.06' NAVD 88
DESCRIPTION:
MONUMENT FOUND ALONG THE NORTHERLY MARGIN OF SW 16TH ST. AT
A BRIDGE CROSSING OF SPRINGBROOK CREEK.
SITE BENCHMARK
OBSERVED ELEVATION: 27.41' NAVD 88
DESCRIPTION:
ENCASED 1 7/8" BRASS DISK W/PUNCH AT THE INTERSECTION OF SW
GRADY WAY AND SENECA AVE. SW
BASIS OF BEARING
HORIZONTAL DATUM
VERTICAL DATUM
21
GRADING PLAN C3.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
G
R
A
D
.
d
w
g
EARTHWORK
SITE AREA:92,783 SF
PROPOSED CUT:22 CU YD
PROPOSED FILL:722 CU YD (IMPORT)
EARTHWORK QUANTITIES PROVIDED ARE FOR PERMITTING
PURPOSES ONLY, CONTRACTOR SHALL DETERMINE
EARTHWORK QUANTITIES FOR CONSTRUCTION
R-438821
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
20
25
20
25
10+00
FG
FG
2
1
.
5
1
10+50
FG
2
1
.
8
5
FG
2
1
.
7
5
11+00
FG
2
1
.
5
7
FG
2
1
.
6
9
11+50
FG
2
1
.
9
5
FG
2
1
.
9
5
12+00
FG
2
1
.
9
5
FG
2
1
.
9
5
12+50
FG
2
1
.
9
5
FG
2
1
.
8
2
13+00
FG
PROPOSED GRADE ELEVATION AT SECTION LINEEXISTING GRADE ELEVATION AT SECTION LINE
EXISTING GRADE AT
SECTION LINE
PROPOSED GRADE
AT SECTION LINE
BLDG ADDITION
APPROXIMATE SUB-GRADE
(REMOVE ASPHALT)
8" SLAB
PROPERTY LINE
PROPERTY LINE
20
25
20
25
50+00
FG FG
50+50
FG
2
1
.
9
5
FG
2
1
.
9
5
51+00
FG
2
1
.
9
5
FG
2
1
.
9
5
51+50
FG
2
1
.
9
1
FG
2
1
.
8
3
52+00
FG
PROPOSED GRADE ELEVATION AT SECTION LINEEXISTING GRADE ELEVATION AT SECTION LINE
PROPOSED GRADE
AT SECTION LINE
EXISTING GRADE AT
SECTION LINE
8" SLAB
APPROXIMATE SUB-GRADE
(REMOVE ASPHALT)
PROPERTY LINE
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
EXISTING BLDG
BLDG ADDITION
22SITE CROSS SECTIONS
C3.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
G
R
A
D
.
d
w
g
A SCALE: H:1" = 20', V:1" = 2'
SECTION A
B SCALE: H:1" = 20', V:1" = 2'
SECTION B
R-438822
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
RAMP
C/C
C/C
C/C
C/C
RAMP
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
E/CE/C
E/C
E/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART OF
SURVEY
(TAX PARCEL NO.
3340404150)
0.1'
4.9'
8.0'
6' CLF
6' CLF6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
E/C
E/C
E/C
E/C
5.1'
9.0'
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
GATE
E/C
E/C
6' CLF
6' CLF
6' CLF
STOP BAR
C/G
C/G
C/G
C/G
C/G
30.0'
DRIVEWAY
E/C
RA/W
RA/W
RA/W
RA/W
RA/W
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
CANOPY
(TYPICAL)
12"MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
STEEL POST
FOR AERIAL
SUBARU SIGN
26.9'DRIVEWAY
C/G RA/W
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
4' CLF
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
0.9'
1.0'
0.9'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
525.46'(C)
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
1
0
5
.
0
4
'
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
0
L1
9
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
A/W
A/W
0.7'
0.9'
1.0'
0.8'
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
GATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
CB #6
CB #5
CB #4
CB #3
CB #2
CB #1
BLDG ADDITION
FF: 21.95
CB #7
EXIST. CB1
EXIST. CB3
EXISTING
BUILDING
FF: 21.95BLDG
ADDITION
EXIST. CB4
61 LF 8" DI CL52 @ 0.25%
89 LF 8" CPEP @ 0.25%
57 LF 8" CPEP @ 0.25%
86 LF 8" CPEP @ 0.46%
57 LF 8" DI CL52 @ 0.25%
28 LF 8" DI CL52 @ 0.25%
130 LF 6" PVC SDR-35 @ 0.25%
16 LF 6" PVC SDR-35 @ 0.25%
16+10
10+00
11
+
0
0
12
+
0
0
13
+
0
0
14+00
15+00 16+00
STORM RUN 1
SHEET C3.4
20+
0
0
20+
4
7
30
+
0
0
31
+
0
0
3
1
+
5
0
STORM RUN 3
SHEET C3.4
STORM RUN 2
SHEET C3.4
CO #3
91 LF 6" PVC SDR-35 @ 0.50%
CO #4
128 LF 6" PVC SDR-35 @ 1.13%
CO #5
9 LF 6" PVC SDR-35 @ 0.50%
CO #6 103 LF 6" PVC SDR-35 @ 0.25%
108 LF 6" PVC SDR-35 @ 1.51%
CO #7
13 LF 6" PVC SDR-35 @ 0.50%
CO #2
CO #1
69 LF 8" CPEP @ 0.26%
18 LF 8" CPEP @ 1.48%
IE: 17.55 8" (W)
IE: 17.00 6" (W)
EXISTING STORM
PIPE TO REMAIN
EXISTING STORM
PIPE TO REMAIN
CB #8 APPROX.
POND BOTTOM
EG: 16.50
EXISTING
DETENTION
POND TO
REMAIN
21 LF 6" PVC SDR-35 @ 0.25%
22.00
22.00
22.00
22
.
0
0
23.0
0
23
.
0
0
23
.
0
0
23
.
0
0
21.00
2
1
.
0
0
22.00
22
.
0
0
22.00
22.0022.00
CONNECT EXISTING BUILDING
ROOF DRAINS, CONTRACTOR TO
POTHOLE AND VERIFY DEPTH
PRIOR TO CONSTRUCTION.
CONNECT EXISTING BUILDING
ROOF DRAINS, CONTRACTOR TO
POTHOLE AND VERIFY DEPTH
PRIOR TO CONSTRUCTION.
OUTLET
PROTECTION
2
C3.5
EXISTING POND TO BE REFRESHED.
REMOVE ALL DEBRIS AND SEDIMENT
BUILD-UP. REMOVE ALL NOXIOUS
WEEDS. POND OUTLET TO BE
CLEARED AND CLEANED.
EXISTING STORM
PIPE TO REMAIN
STA:12+50.33, 0.00'
EXIST. CB2
STORM STRUCTURE TABLE
STRUCTURE NAME
CB #1
TYPE 1
N 173874.77
E 1296386.65
CB #2
TYPE 1
N 173790.74
E 1296405.48
CB #3
TYPE 1
N 173778.29
E 1296350.24
CB #4
TYPE 1
N 173758.79
E 1296263.78
CB #5
TYPE 1
N 173795.86
E 1296220.61
CB #6
TYPE 1
N 173815.39
E 1296240.61
CB #7
48" TYPE 2
W/ SUMP PUMP
0.4CFS @ 5' TDH
N 173835.29
E 1296174.69
CB #8
6x12 BIOPOD
UNDERGROUND VAULT
N 173792.17
E 1296477.46
CO #1
CO
N 173976.94
E 1296166.26
STRUCTURE DETAILS
RIM = 21.59
IE = 18.90 (8" S)
IE = 18.90 (8" NE)
RIM = 21.60
IE = 18.50 (8" W)
IE = 18.50 (8" N)
IE = 18.50 (8" E)
RIM = 21.60
IE = 18.64 (8" W)
IE = 18.64 (8" E)
RIM = 21.60
IE = 18.86 (8" NW)
IE = 18.86 (8" E)
RIM = 21.66
IE = 19.00 (8" NW)
IE = 19.00 (8" SE)
IE = 19.00 (8" NE)
RIM = 21.40
IE = 19.07 (8" SW)
RIM = 21.17
IE = 19.15 (8" SE)
IE = 19.32 (6" NE)
IE = 19.32 (6" NW)
IE = 18.50 (8" N)
RIM = 22.93
IE = 18.32 (8" W)
IE = 17.82 (8" E)
RIM = 21.37
IE = 19.68 (6" S)
STORM STRUCTURE TABLE
STRUCTURE NAME
CO #2
CO
N 173847.01
E 1296163.19
CO #3
CO
N 173855.79
E 1296253.46
CO #4
CO
N 173766.96
E 1296273.50
CO #5
CO
N 173795.13
E 1296398.36
CO #6
CO
N 173804.01
E 1296396.36
CO #7
CO
N 173909.80
E 1296372.49
EXIST. CB1
EXISTING TYPE 1
N 173898.95
E 1296401.89
EXIST. CB2
EXISTING TYPE 1
N 174067.99
E 1296401.66
EXIST. CB3
EXISTING TYPE 1
N 173985.44
E 1296176.98
STRUCTURE DETAILS
RIM = 21.38
IE = 19.36 (6" N)
IE = 19.36 (6" SE)
RIM = 21.95
IE = 19.22 (6" S)
RIM = 21.85
IE = 18.76 (6" E)
IE = 18.76 (6" N)
RIM = 21.85
IE = 17.31 (6" N)
IE = 17.31 (6" W)
RIM = 21.90
IE = 17.26 (6" E)
IE = 17.26 (6" S)
IE = 17.26 (6" N)
RIM = 21.75
IE = 18.90 (6" S)
IE = 18.90 (6" E)
RIM = 21.31
IE = 19.00 (8" SW)
IE = 19.00 (8" N)
RIM = 21.46
IE = 19.69 (8" S)
RIM = 21.20
IE = 18.75 (8" S)
IE = 18.88 (12" NE)
IE = 18.77 (6" E)
STRUCTURE NAME
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE,
GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE
INTERSECTION OF LIND AVE. SW AND SW 16TH ST., BEING CITY OF
RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK, BEING CITY OF RENTON CONTROL ID. 1891,
RESPECTIVELY.
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY
THE CITY OF RENTON PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND)
WAS HELD AT CITY OF RENTON CONTROL ID. 1895
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
PROJECT PRIMARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1895
PUBLISHED ELEVATION: 25.702' NAVD 88
DESCRIPTION:
ENCASED 3" BRASS DISK W/PUNCH LOCATED AT THE INTERSECTION OF
LIND AVE. SW AND SW 16TH ST.
PROJECT SECONDARY BENCHMARK:
CITY OF RENTON CONTROL ID. 1891
PUBLISHED ELEVATION: 24.1568' NAVD 88
OBSERVED ELEVATION: 24.06' NAVD 88
DESCRIPTION:
MONUMENT FOUND ALONG THE NORTHERLY MARGIN OF SW 16TH ST. AT
A BRIDGE CROSSING OF SPRINGBROOK CREEK.
SITE BENCHMARK
OBSERVED ELEVATION: 27.41' NAVD 88
DESCRIPTION:
ENCASED 1 7/8" BRASS DISK W/PUNCH AT THE INTERSECTION OF SW
GRADY WAY AND SENECA AVE. SW
BASIS OF BEARING
HORIZONTAL DATUM
VERTICAL DATUM
23
STORM PLAN C3.3Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
T
R
M
.
d
w
g
1.PROVIDE 4" PERFORATED FOUNDATION DRAINS
AROUND BUILDING FOUNDATION. CONNECT TO
STORM SYSTEM.
2.PROVIDE 6" PVC SDR-35 ROOF DRAIN LINES AT 0.5%
MINIMUM SLOPE UNLESS OTHERWISE NOTED.
3.PROVIDE HERRINGBONE GRATE INLETS FOR ALL
CATCH BASINS PER WSDOT STANDARD PLAN
B30.50.03 UNLESS OTHERWISE NOTED.
4.CONTRACTOR SHALL COORDINATE AND CONFIRM
DOWNSPOUT ROOF DRAIN LOCATIONS WITH
BUILDING PLANS PRIOR TO CONSTRUCTION.
DOWNSPOUTS SHALL BE COORDINATED WITH
FOOTING CONSTRUCTION TO ENSURE ADEQUATE
COVER.
STORM NOTES
1
C3.6
R-438823
INSTALL ETHAFOAM OR EQUIVALENT
WHERE 12-INCH OF VERTICAL
SEPARATION CANNOT BE MET
CUT AND CAP SEWER
AT PROPERTY LINE
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
12
15
20
12
15
20
10+00
FG FG
10+50
FG FG
11+00
FG FG
11+50
FG FG
12+00
FG
FG
2
1
.
4
8
12+50
FG
2
1
.
7
9
FG
2
1
.
6
7
13+00
FG
2
1
.
6
5
FG
2
1
.
6
7
13+50
FG
2
1
.
6
7
FG
2
1
.
7
8
14+00
FG
2
1
.
7
1
FG
2
1
.
6
1
14+50
FG
2
1
.
7
5
FG
2
1
.
6
3
15+00
FG
2
2
.
2
3
FG
2
2
.
6
0
15+50
FG
2
2
.
9
1
FG
16+00
FG
16+09
FG
PROPOSED GRADE ELEVATION AT
STORM RUN CENTERLINE
EXISTING GRADE ELEVATION AT
STORM RUN CENTERLINE
PROPOSED GRADE AT
STORM RUN CENTERLINEEXISTING GRADE AT
STORM RUN CENTERLINE
STA: 14+79.48, 0.00'
IE: 18.50 8" (W)
IE: 18.50 8" (N)
IE: 18.50 8" (E)
RIM: 21.60
CB #2, TYPE 1
57 LF 8" CPEP @ 0.25%
STA: 14+22.85, 0.00'
IE: 18.64 8" (W)
IE: 18.64 8" (E)
RIM: 21.60
CB #3, TYPE 1
89 LF 8" CPEP @ 0.25%
STA: 13+34.22, 0.00'
IE: 18.86 8" (NW)
IE: 18.86 8" (E)
RIM: 21.60
CB #4, TYPE 1
57 LF 8" DI CL52 @ 0.25%
STA: 12+77.31, 0.00'
IE: 19.00 8" (NW)
IE: 19.00 8" (SE)
IE: 19.00 8" (NE)
RIM: 21.66
CB #5, TYPE 1
61 LF 8" DI CL52 @ 0.25%
STA: 12+16.79, 0.00'
IE: 19.15 8" (SE)
IE: 19.32 6" (NE)
IE: 19.32 6" (NW)
IE: 18.50 8" (N)
RIM: 21.17
CB #7, 48" TYPE 2
W/ SUMP PUMP
0.4CFS @ 5' TDH
69 LF 8" CPEP @ 0.26%
STA: 15+51.47, 0.03' RT
IE: 18.32 8" (W)
IE: 17.82 8" (E)
RIM: 22.93
CB #8, 6x12 BIOPOD
UNDERGROUND VAULT
18 LF 8" CPEP @ 1.48%
2-YR WATER
SURFACE
ELEV: 18.32
8" SEWER
CROSSINGSTA: 10+05, 0.00'
IE: 19.10 12" (SW)
RIM: 21.20
EXIST. CB4, EXISTING TYPE 1
62 LF 8" PVC SDR-35 @ 0.36%
STA: 10+66.62, 0.00' RT
IE: 18.75 8" (S)
IE: 18.88 12" (NE)
IE: 18.77 6" (E)
RIM: 21.20
EXIST. CB3, EXISTING TYPE 1
150 LF 8" PVC SDR-35 @ 0.17%
8" STORM BOT: 19.11
EX. 10" WATER TOP: 17.61
SEPARATION: 1.5'
CONTRACTOR TO POTHOLE
AND VERIFY DEPTH PRIOR
TO CONSTRUCTION
8" STORM BOT: 18.94
10" WATER TOP: 17.40
SEPARATION: 1.54'
8" STORM BOT: 18.47
10" WATER TOP: 15.84
SEPARATION: 2.63'
ELEV: 18.94
100-YR WATER
SURFACE
ELEV: 19.61
POWER CONDUIT
INSTALLED 12"
MINIMUM BELOW
STORM
12
15
20
12
15
20
20+00
FG
2
1
.
5
8
FG
2
1
.
5
7
20+46.99
FG
2
1
.
7
2
STA: 20+36.99, 0.00'
IE: 19.00 8" (NW)
IE: 19.00 8" (SE)
IE: 19.00 8" (NE)
RIM: 21.66
CB #5, TYPE 1
STA: 20+09.04, 0.00'
IE: 19.07 8" (SW)
RIM: 21.40
CB #6, TYPE 1
28 LF 8" DI CL52 @ 0.25%
PROPOSED GRADE ELEVATION AT
STORM RUN CENTERLINE
EXISTING GRADE ELEVATION AT
STORM RUN CENTERLINE
PROPOSED GRADE AT
STORM RUN CENTERLINE
EXISTING GRADE AT
STORM RUN CENTERLINE
8" STORM BOT: 19.02
10" WATER TOP: 17.52
SEPARATION: 1.5'
10
15
20
10
15
20
30+00
FG
FG
2
1
.
3
1
30+50
FG
2
1
.
5
7
FG
2
1
.
7
0
31+00
FG
2
1
.
8
0
FG
2
1
.
6
7
31+49.69
FG
2
1
.
9
4
86 LF 8" CPEP @ 0.46%
STA: 30+53.58, 0.00'
IE: 18.90 8" (S)
IE: 18.90 8" (NE)
RIM: 21.59
CB #1, TYPE 1
29 LF 8" PVC SDR-35 @ 0.34%
STA: 30+25, 0.00'
IE: 19.00 8" (SW)
IE: 19.00 8" (N)
RIM: 21.31
EXIST. CB1, EXISTING TYPE 1
169 LF 8" PVC SDR-35 @ 0.41%
STA: 31+39.69, 0.00'
IE: 18.50 8" (W)
IE: 18.50 8" (N)
IE: 18.50 8" (E)
RIM: 21.60
CB #2, TYPE 1
PROPOSED GRADE ELEVATION
AT STORM RUN CENTERLINE
EXISTING GRADE ELEVATION
AT STORM RUN CENTERLINE
PROPOSED GRADE AT
STORM RUN CENTERLINE
EXISTING GRADE AT
STORM RUN CENTERLINE
8" STORM BOT: 18.56
6" STORM TOP: 17.76
SEPARATION: 0.8'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
24
STORM RUN PROFILES C3.4Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
T
R
M
.
d
w
g
1 SCALE: H 1" = 20', V 1" = 2'
STORM RUN 1
2 SCALE: H 1" = 20', V 1" = 2'
STORM RUN 2 3 SCALE: H 1" = 20', V 1" = 2'
STORM RUN 3
R-438824
INSTALL ETHAFOAM OR
EQUIVALENT WHERE 12-INCH OF
SEPARATION CANNOT BE MET
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
25
STORM SYSTEM NOTES AND
DETAILS
C3.5Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
T
R
M
-
D
E
T
L
.
d
w
g
OUTFALL PIP
E
EXISTING AND/OR
PROPOSED GROUND
1'
M
I
N
.
4" MIN. FACE
QUARRY ROCK
12" MIN. DEPTH (12"Ø PIPE)
18" MIN. DEPTH (15"-18"Ø PIPE)
24" MIN. ( 24"-36"Ø PIPE)
* UNLESS
OTHERWISE
NOTED ON PLANS
DI
A
.
+
6
'
INLET/OUTFALL PIPE
*8'
4"
0.5%
2" MIN.
MIN.
BUILDING
FOUNDATION SEE
STRUCTURAL DETAILS
6" PVC SDR 35 TYP.
FINISHED GRADE
6" PVC CAP CUT HOLE TO ALLOW
DOWNSPOUT TO PENETRATE
WITH 1/8" CLEARANCE.
ROOF DOWNSPOUT SEE
ARCHITECTURAL DETAILS.
PROVIDE FITTINGS
AS REQUIRED
COORDINATE DOWNSPOUT LOCATIONS WITH
ARCHITECTURAL PLANS AND NOTCH FOOTINGS
TO ACCOMMODATE ROOF DRAINS.
FOOTING 6" BELOW
GRADE AT DOCKS.
REFER TO STRUCTURAL.
18" (MIN.)
2" (MIN.)
4" PERFORATED RIGID DRAIN PIPE
REQUIRED AT LANDSCAPE AREAS
(SURROUND WITH 1" ROCK)
12" MIN.
SURFACE SEAL: NATIVE SOIL OR
OTHER LOW PERMEABILITY MATERIAL.
NOTES:
DO NOT TIE ROOF DOWNSPOUTS TO FOOTING DRAIN.
SURFACE SEAL TO CONSIST OF 12" OF LESS PERMEABLE, SUTIABLE SOIL. SLOPE AWAY FROM BUILDING.
CONNECT TO
DETENTION SYSTEM
2 NOT TO SCALE
OUTLET PROTECTION
1 NOT TO SCALE
ROOF DOWNSPOUT AND FOOTING DRAIN
·SOIL RETENTION. RETAIN, IN AN UNDISTURBED STATE, THE DUFF LAYER AND NATIVE TOPSOIL TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY
AREAS REQUIRING GRADING REMOVE AND STOCKPILE THE DUFF LAYER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT
ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE.
·SOIL QUALITY. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED
INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE
FOLLOWING:
1.A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN BEDS, AND 5% ORGANIC MATTER CONTENT IN
TURF AREAS, AND A PH FROM 6.0 TO 8.0 OR MATCHING THE PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM
DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE
CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE
UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE.
2.MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL
3.USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS:
3.a.THE ORGANIC CONTENT FOR “PRE-APPROVED” AMENDMENT RATES CAN BE MET ONLY USING COMPOST MEETING THE COMPOST
SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT THE COMPOST MAY HAVE UP TO 35%
BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 40% TO 65%, AND A CARBON TO
NITROGEN RATIO BELOW 25:1. THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS COMPOSED ENTIRELY
OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION.
3.b.CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEETING “A)” ABOVE; OR OTHER
ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND NOT EXCEEDING THE LIMITS
IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220.
4.THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE TYPE OF VEGETATION TO BE ESTABLISHED.
·IMPLEMENTATION OPTIONS: THE SOIL QUALITY DESIGN GUIDELINES LISTED ABOVE CAN BE MET BY USING ONE OF THE METHODS LISTED
BELOW:
1.LEAVE UNDISTURBED NATIVE VEGETATION AND SOIL, AND PROTECT FROM COMPACTION DURING CONSTRUCTION.
2.AMEND EXISTING SITE TOPSOIL OR SUBSOIL EITHER AT DEFAULT “PRE-APPROVED” RATES, OR AT CUSTOM CALCULATED RATES BASED
ON TESTS OF THE SOIL AND AMENDMENT.
3.STOCKPILE EXISTING TOPSOIL DURING GRADING, AND REPLACE IT PRIOR TO PLANTING.
4.STOCKPILED TOPSOIL MUST ALSO BE AMENDED IF NEEDED TO MEET THE ORGANIC MATTER OR DEPTH REQUIREMENTS, EITHER AT A
DEFAULT “PRE-APPROVED” RATE OR AT A CUSTOM CALCULATED RATE.
5.IMPORT TOPSOIL MIX OF SUFFICIENT ORGANIC CONTENT AND DEPTH TO MEET THE REQUIREMENTS. MORE THAN ONE METHOD MAY BE
USED ON DIFFERENT PORTIONS OF THE SAME SITE. SOIL THAT ALREADY MEETS THE DEPTH AND ORGANIC MATTER QUALITY
STANDARDS, AND IS NOT COMPACTED DOES NOT NEED TO BE AMENDED.
SOIL AMENDMENT
R-438825
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
26
STORM SYSTEM NOTES AND
DETAILS
C3.6Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
T
R
M
-
D
E
T
L
.
d
w
g
1 NOT TO SCALE
6X12 BIOPOD BIOFILTER
0.1548
0.7387
PER PLAN
PER PLAN
WEST
EAST
CB #11
R-438826
8" Ø
8" Ø
CPEP
CPEP
18.32
17.82
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
27
CITY OF RENTON STANDARD
STORM NOTES
C3.7Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
T
R
M
-
S
T
N
D
-
D
E
T
L
.
d
w
g
1 NOT TO SCALE
SURFACE WATER STANDARD PLAN NOTES
R-438827
* NOTE NUMBERS 9, 16, 17, 20, 28, 29 AND 31 ARE NOT APPLICABLE
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L1
5
GP GP
GP
GP
GP GP
GP
GP
P
GP
GP
GP N7
7
°
2
7
'
4
4
"
E
9
8
8
.
6
6
'
(
C
)
C/
G
NO
T
P
A
R
T
O
F
S
U
R
V
E
Y
(T
A
X
P
A
R
C
E
L
N
O
.
3
3
4
0
4
0
4
1
5
0
)
23
.
9
'
DR
I
V
E
W
A
Y
20
.
6
'
DR
I
V
E
W
A
Y
C/
G
E/
C
E/
C
NO
T
P
A
R
T
O
F
SU
R
V
E
Y
(T
A
X
P
A
R
C
E
L
N
O
.
33
4
0
4
0
4
1
5
0
)
GA
T
E
0.1
'
4.9
'
6'
C
L
F
7'
C
L
F
0.2
'
0.3
'
0.2
'
7'
C
L
F
14
.
4
'
6'
C
L
F
6'
C
L
F
6'
C
L
F
6'
C
L
F
8'
C
L
F
E/
C
E/
C
E/
C
E/
C
8.2
'
17
.
5
'
3.1
'
0.3
'
10
'
C
L
F
GA
T
E
0.3
'
0.1
'
3X
8
"
UN
K
N
O
W
N
DE
C
I
D
U
O
U
S
GA
T
E
6'
C
L
F
8'
C
L
F
8'
C
L
F
8'
C
L
F
6'
C
L
F
4'
C
L
F
1.5
'
1.4
'
1.0
'
2.1
'
0.9
'
1.0
'
0.9
'
UN
K
N
O
W
N
U
S
E
CL
E
A
N
O
U
T
RIM
=
2
2
.
0
6
'
UN
K
N
O
W
N
U
S
E
CL
E
A
N
O
U
T
RI
M
=
2
1
.
9
6
'
52
5
.
4
6
'
(
C
)
N7
7
°
2
6
'
1
0
"
E
11
9
.
9
2
'
N01°22'43"E
116.38'
L18
L1
7
L
1
6
L20L21
N
7
7
°
2
4
'
3
8
"
E
12
3
.
2
9
'
L19
A/
W
A/
W
8'
/
6
'
C
L
F
I
N
T
E
R
S
E
C
T
I
O
N
BE
A
R
S
S
7
9
°
1
5
'
W
,
2
.
9
'
F
R
O
M
T
H
E
CA
L
C
U
L
A
T
E
D
L
O
T
C
O
R
N
E
R
GP
GP
C/
G
C/
C
14
.
9
'
DR
I
V
E
W
A
Y
GA
T
E
E/
C
E/
C
6'
C
L
F
1X
7
"
,
5
X
4
"
,
4
X
3
"
UN
K
N
O
W
N
DE
C
I
D
U
O
U
S
6'
C
L
F
6'
W
D
F
6'
W
D
F
6'
W
D
F
C/
G
C/
G
QW
E
S
T
T
E
L
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PE
R
A
F
N
2
0
0
3
0
3
2
7
0
0
0
9
2
5
PR
I
V
A
T
E
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PE
R
E
A
S
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AF
N
2
0
0
2
0
6
1
2
0
0
0
6
2
2
QW
E
S
T
T
E
L
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PE
R
A
F
N
2
0
0
3
0
3
2
7
0
0
0
9
2
5
PR
I
V
A
T
E
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PE
R
E
A
S
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AF
N
2
0
0
2
0
6
1
2
0
0
0
6
2
2
UT
I
L
I
T
I
E
S
E
A
S
E
M
E
N
T
T
O
T
H
E
C
I
T
Y
O
F
R
E
N
T
O
N
PE
R
A
F
N
2
0
0
1
0
9
0
6
0
0
2
1
7
7
,
C
I
T
Y
O
F
R
E
N
T
O
N
O
R
D
I
N
A
N
C
E
4
9
1
4
(E
N
C
O
M
P
A
S
S
E
S
W
H
O
L
E
V
A
C
A
T
E
D
A
L
L
E
Y
)
BU
I
L
D
I
N
G
F
I
N
I
S
H
FL
O
O
R
A
T
C
E
N
T
E
R
O
F
BA
Y
D
O
O
R
EL
E
V
=
2
1
.
9
4
'
N
A
V
D
8
8
6'
C
L
F
A
N
G
L
E
P
O
I
N
T
BE
A
R
S
N
5
3
°
2
3
'
W
,
1
.
3
'
F
R
O
M
C
A
L
C
U
L
A
T
E
D
L
O
T
C
O
R
N
E
R
8'
C
L
F
E
N
D
B
E
A
R
S
N
2
5
°
4
8
'
W
,
1
.
0
'
F
R
O
M
C
A
L
C
U
L
A
T
E
D
L
O
T
CO
R
N
E
R
10+00
11+00
11+65
SSCO #2
RIM: 21.65
IE: 15.33 6" (S)
IE: 15.33 6" (N)
IE: 16.18 6" (E)
SSCO #1
RIM: 21.51
IE: 15.72 6" (W)
IE: 15.72 6" (N)
8 LF 6" PVC @ 2.00%
PRIVATE
8 LF 6" PVC @ 2.00%
PRIVATE
76 LF 6" PVC @ 2.00%
PRIVATE
22
.
0
0
23.00
23.00
21
.
0
0
22.00 21.
0
0
22.00
13
+
0
0
1
3
+
5
4
AREA DRAIN, TYPE 1
RIM: 21.64
IE: 16.02 6" (W)
IE: 16.02 6" (E)
1
OIL/WATER SEPARATOR 2
C4.4
EXISTING
BUILDING
FF: 21.95
15 LF 6" PVC @ 2.00%
PRIVATE
3 LF 6" PVC @ 2.00%
PRIVATE
CUT AND CAP SEWER
AT PROPERTY LINE
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
28
SEWER PLAN AND PROFILE C4.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
SEE SHEET C4.2 FOR
EXISTING SEWER PLAN AND PROFILE
PROP. 6"
SEWER
T.O.P= 16.64
PROP 6"
ROOF DRAIN
B.O.P= 18.24
1.50'
1
S-438801
INSTALL BUILDING
SERVICE CONNECTION
2
C4.3
WW
P
-
2
7
-
4
3
8
8
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
G
P
GP
GP
GP
GP
GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
E/C
6' CLF
NOT PAR
T
O
F
S
U
R
V
E
Y
(TAX PAR
C
E
L
N
O
.
3
3
4
0
4
0
4
1
5
0
)
NOT PAR
T
O
F
SURVEY(TAX PAR
C
E
L
N
O
.
3340404
1
5
0
)
0.1'
4.9'
8.0'
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
E/C
E/C
E/C
E/C
5.1'
9.0'8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"UNKNOW
N
DECIDUO
U
S
GATE
E/C
E/C
6' CLF
6' CLF 6' CLF
STOP BA
R
C/G
C/G
C/G
C/G
30.0'DRIVEWAY
E/C
RA/WRA/W
RA/W
RA/W
RA/W
RA/W
BUILDI
N
G
F
I
N
I
S
H
F
L
O
O
R
A
T
CENTER
O
F
P
E
D
.
D
O
O
R
LABELE
D
"
S
P
R
I
N
K
L
E
R
R
O
O
M
"
ELEV=21.
9
5
'
N
A
V
D
8
8
BUILDIN
G
F
I
N
I
S
H
F
L
O
O
R
A
T
CENTER
O
F
D
O
U
B
L
E
P
E
D
.
D
O
O
R
ELEV=22.
0
3
'
N
A
V
D
8
8
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUM
N
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL
)
EDGE
CANOPY
(TYPICAL
)
12"
MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE
6' CLF
STEEL PO
S
T
F
O
R
AERIAL
WALKER'
S
R
E
N
T
O
N
SUBARU
P
A
R
T
S
A
N
D
SERVICE
C
E
N
T
E
R
S
I
G
N
SERVICE
C
E
N
T
E
R
DIRECTI
O
N
S
S
I
G
N
C/C C/CRAMP
E/C
C/C
C/C
RAMP
26.9'DRIVEWAY
C/G
RA/W
6' CLF
6' CLF
GATE
6' CLF
FENCE T
R
A
N
S
I
T
I
O
N
6' CLF/6'
S
T
E
E
L
6' STEEL
8' CLF8' CLF8' CLF8' CLF
8' CLF
6' CLF
0.8'0.8'1.5'1.4'1.0'
2.1'
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.
3
1
'
IE=19.00
'
8
"
P
V
C
N
IE=18.79
'
8
"
P
V
C
S
W
IE=19.15'
6
"
P
V
C
W
STORMD
R
A
I
N
M
A
N
H
O
L
E
TYPE II
RIM=20.
3
5
'
IE=14.80
'
8
"
P
V
C
E
8" STAN
D
P
I
P
E
S
T
R
U
C
T
U
R
E
ON WES
T
S
I
D
E
IE=14.80'
8
"
P
V
C
W
TOP STA
N
D
P
I
P
E
=
1
7
.
5
5
'
BOTTOM
S
T
A
N
D
P
I
P
E
=
1
3
.
8
5
'
LADDER=
N
STORMD
R
A
I
N
M
A
N
H
O
L
E
TYPE II
RIM=20.
3
6
'
IE=14.86'
8
"
S
(
F
U
L
L
O
F
D
I
R
T
)
8" STAN
D
P
I
P
E
S
T
R
U
C
T
U
R
E
ON WEST
S
I
D
E
IE=15.27'
8
"
P
V
C
W
TOP STA
N
D
P
I
P
E
=
1
7
.
8
1
'
BOTTOM
S
T
A
N
D
P
I
P
E
=
1
4
.
8
1
'
LADDER
=
N
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.4
6
'
IE=19.69
8
"
P
V
C
S
0.9'
1.0'
0.9'
UNKNOWN
U
S
E
CLEANOUT
RIM=22.06
'
UNKNOWN
U
S
E
CLEANOU
T
RIM=21.96'
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=20.0
4
'IE=18.32'
1
2
"
P
V
C
N
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.2
0
'
IE=19.10'
1
2
"
P
V
C
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=20.7
0
'IE=17.92'
1
2
"
P
V
C
N
E
IE=18.01
'
1
2
"
P
V
C
S
525.46'(C)
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L2
0
L2
1
N77°24'38"E
123.29'
25
4
.
8
8
'
L1
2
L1
0
L11
L1
9
FND 1/2" RE
B
A
R
A
N
D
C
A
P
S
T
A
M
P
E
D
"LS 19635
"
REBAR BE
A
R
S
S
8
8
°
2
4
'
3
3
"
E
,
0
.
2
3
'
FROM THE
C
A
L
C
U
L
A
T
E
D
L
O
T
C
O
R
N
E
R
VISITED 11
/
1
8
/
2
0
2
4
A/W
GATE
8'/6' CLF
I
N
T
E
R
S
E
C
T
I
O
N
BEARS S
7
9
°
1
5
'
W
,
2
.
9
'
F
R
O
M
T
H
E
CALCULA
T
E
D
L
O
T
C
O
R
N
E
R
75
.
2
0
'
PRIVAT
E
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PER EAS
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AFN 200
2
0
6
1
2
0
0
0
6
2
2
QWEST TE
L
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PER AFN
2
0
0
3
0
3
2
7
0
0
0
9
2
5
PRIVATE
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PER EAS
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AFN 200
2
0
6
1
2
0
0
0
6
2
2
UTILITIE
S
E
A
S
E
M
E
N
T
T
O
T
H
E
C
I
T
Y
O
F
R
E
N
T
O
N
PER AFN
2
0
0
1
0
9
0
6
0
0
2
1
7
7
,
C
I
T
Y
O
F
R
E
N
T
O
N
O
R
D
I
N
A
N
C
E
4
9
1
4
(ENCOM
P
A
S
S
E
S
W
H
O
L
E
V
A
C
A
T
E
D
A
L
L
E
Y
)
BUILDIN
G
F
I
N
I
S
H
FLOOR A
T
C
E
N
T
E
R
O
F
BAY DOO
R
ELEV=21.
9
4
'
N
A
V
D
8
8
6' CLF A
N
G
L
E
P
O
I
N
T
BEARS N
5
3
°
2
3
'
W
,
1
.
3
'
F
R
O
M
C
A
L
C
U
L
A
T
E
D
L
O
T
C
O
R
N
E
R
8' CLF E
N
D
B
E
A
R
S
N
2
5
°
4
8
'
W
,
1
.
0
'
F
R
O
M
C
A
L
C
U
L
A
T
E
D
L
O
T
CORNER
UTILITIE
S
E
A
S
E
M
E
N
T
T
O
T
H
E
C
I
T
Y
O
F
R
E
N
T
O
N
PER AFN
2
0
0
1
0
9
0
6
0
0
2
1
7
7
,
C
I
T
Y
O
F
R
E
N
T
O
N
O
R
D
I
N
A
N
C
E
4
9
1
4
(ENCOM
P
A
S
S
E
S
W
H
O
L
E
V
A
C
A
T
E
D
A
L
L
E
Y
)
PSE ELE
C
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
RIM=21.
2
0
'
IE=18.88
'
1
2
"
P
V
C
N
E
IE=18.77'
6
"
P
V
C
S
E
IE=18.75'
1
2
"
P
V
C
S
PSE ELE
C
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
UTILITI
E
S
E
A
S
E
M
E
N
T
T
O
T
H
E
C
I
T
Y
O
F
R
E
N
T
O
N
PER AFN
2
0
0
2
0
2
0
7
0
0
2
5
3
9
,
C
I
T
Y
O
F
R
E
N
T
O
N
O
R
D
I
N
A
N
C
E
4
9
4
2
(ENCOM
P
A
S
S
E
S
W
H
O
L
E
V
A
C
A
T
E
D
S
T
R
E
E
T
)
SW 13TH ST
BLDG
A
D
D
I
T
I
O
N
FF: 21.
9
5
EXISTI
N
G
BUILDI
N
G
FF: 21.
9
5
BLDG
ADDITI
O
N
10
+
0
0
11
+
0
0
11
+
6
5
SSCO #2
RIM: 21.65
IE: 15.33 6" (S)
IE: 15.33 6" (N)
IE: 16.18 6" (E)
SSCO #1
RIM: 21.51
IE: 15.72 6" (W)
IE: 15.72 6" (N)
8 LF 6" PVC @ 2.00%
PRIVATE
8 LF 6" PVC @ 2.00%
PRIVATE
76 LF 6" PVC @ 2.00%
PRIVATE
22.00
21.00
22
.
0
0
2
1
.
0
0
10+00 11+00 12+00 13+00 13+54
SE
N
E
C
A
AV
E
S
W
EXISTING SSMH #2
RE-CHANNEL EXISTING
MANHOLE, NE PIPE TO BE
REMOVED AND PLUGGED
7 LF 8" DIP CL52 @ 2.00%
PRIVATE
SSCO #4
RIM: 21.50
IE: 13.31 8" (N)
IE: 13.31 8" (E)
5 LF 8" DIP CL52 @ 2.00%
PRIVATE
6 LF 8" DIP CL52 @ 2.00%
PRIVATE
SSCO #5
RIM: 21.48
IE: 13.09 8" (NW)
IE: 13.09 8" (S)
27 LF 8" DIP CL52 @ 2.00%
PRIVATE
SSCO #6
RIM: 20.67
IE: 12.55 8" (E)
IE: 12.55 8" (W)
IE: 12.55 8" (SE)
AREA DRAIN, TYPE 1
RIM: 21.64
IE: 16.02 6" (W)
IE: 16.02 6" (E)
1
STA:11+68.10, 0.00'
OIL
/
W
A
T
E
R
S
E
P
A
R
A
T
O
R
2 C4
.
4
EX
I
S
T
I
N
G
BU
I
L
D
I
N
G
FF
:
2
1
.
9
5
15 LF 6" PVC @ 2.00%
PRIVATE
EXISTING BUILDING
FF: 21.95
30 LF 6" PVC @ 12.70%
PRIVATE
SSCO #7
RIM: 21.33
IE: 13.18 6" (E)
IE: 13.18 6" (SW)
6 LF 6" PVC @ 10.00%
PRIVATE
3 LF 6" PVC @ 2.00%
PRIVATE
CU
T
A
N
D
C
A
P
S
E
W
E
R
AT
P
R
O
P
E
R
T
Y
L
I
N
E
5
10
15
20
25
5
10
15
20
25
10+00
FG FG
10+50
FG FG
11+00
FG FG
11+50
FG FG
12+00
FG FG
12+50
FG FG
13+00
FG FG
13+50
FG
13+53.95
FG
STA: 10+29.91, 0.00'
RIM: 20.52
EXISTING SSMH #2, EXISTING SSMH 48"
IE IN: 12.41 (8"E)
IE OUT: 12.22 (8"W)
IE OUT: 12.52 (8"S)
249 LF 8" PVC @ 0.44%
PUBLIC
120 LF 8" PVC @ 0.44%
PUBLIC
FINISHED GRADE AT
SEWER CENTERLINE
EXISTING GRADE AT
SEWER CENTERLINE
EXISTING GRADE AT
SEWER CENTERLINE
STA: 10+62.85, 0.00'
RIM: 20.67
SSCO #6, SSCO
IE IN: 12.55 (8"E)
IE OUT: 12.55 (8"W)
IE OUT: 12.55 (8"SE)
33 LF 8" CONCRETE PIPE @ 0.44%
PUBLIC
EXISTING 16" STEEL
CASING PIPE
PROPOSED 16" CASING
EXTENSION
3
C4.5
PROPOSED CASING TO BE WELDED
ONTO EXISTING. CASING TO HAVE A
CONSTANT SLOPE AND BE INSTALLED
WITH CALPICO M-6 SS CASING
INSULATORS.
BUILDING SERVICE CONNECTION
STA: 13+11.50
BUILDING SERVICE CONNECTION
STA: 10+68.41
END OF EXISTING
CONCRETE PIPE
32 LF OF 8" CONCRETE
PIPE TO BE REPLACED
WITH PVC
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
29
EXISTING SEWER PLAN AND PROFILE C4.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
SEE SHEET C4.1 FOR PRIVATE SIDE SEWER PLAN
EXISTING SEWER PROFILE
SCALE: H:1"=20', V:1"=2'
EXISTING SEWER
MAIN ENCASEMENT
EXTEND SEWER
MAIN ENCASEMENT
5.0' PAST BUILDING
FOUNDATIONS
REPLACE BACKWATER
VALVE WITHIN SEWER
SERVICE MANHOLE
BUILDING SEWER
SERVICE CONNECTION
TO BE RELOCATED
OUTSIDE OF
ENCASEMENT
CONNECT TO CENTER
OF TRENCH DRAIN
REFER TO ARCHITECT
DRAWINGS
OIL/WATER
SEPARATOR
1
C4.6
S-438802
WW
P
-
2
7
-
4
3
8
8
INSTALL BUILDING
SERVICE CONNECTION
2
C4.3
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
30SEWER NOTES AND DETAILS
C4.3Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
1 NOT TO SCALE
SANITARY SEWER PIPE BEDDING 2 NOT TO SCALE
SIDE SEWER STUB INSTALLATION
S-438803
WW
P
-
2
7
-
4
3
8
8
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
31SEWER NOTES AND DETAILS
C4.4Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
1 NOT TO SCALE
AIR TEST TABLE 2 NOT TO SCALE
OIL WATER SEPARATOR (SERVICE BAYS)
S-438804
WW
P
-
2
7
-
4
3
8
8
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
32SEWER NOTES AND DETAILS
C4.5Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
1 NOT TO SCALE
STANDARD SANITARY MANHOLE 3 NOT TO SCALE
SEWER CASING
S-438805
WW
P
-
2
7
-
4
3
8
8
2
CITY-OWNED SEWER MANHOLE
FRAME AND COVER
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
33SEWER NOTES AND DETAILS
C4.6Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
S
S
W
R
.
d
w
g
1 NOT TO SCALE
OIL WATER SEPARATOR (UNDER DRIVE THRU)
S-438806
WW
P
-
2
7
-
4
3
8
8
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
6' CLF
6' CLF
8' CLF
E/C
E/C
GATE
C/G
C/G
RA/W
RA/W
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
E/C
E/C
E/C
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
13"MAPLE
17"
MAPLE
11"
MAPLE
14"MAPLE
GATE 6' CLF
STEEL POST
FOR AERIAL
SUBARU SIGN
26.9'DRIVEWAY
C/G RA/W
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
4' CLF
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
0.9'
525.46'(C)
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
A/W
A/W
0.7'
0.9'
1.0'
0.8'
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNERGATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
SE
N
E
C
A
A
V
E
S
W
SW 13TH
S
T
INTERSTATE 405
BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
BLDG
ADDITION
10+00
11
+
0
0
12+00
13+00
1
4
+
0
0
14+10
STA:10+41.46, 0.00'
1-90° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA:11+29.25, 0.00'
1-45° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA:11+39.31, 0.00'
1-45° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA:13+07.56, 0.00'
1-90° 10" BEND (MJ)
1-10" GATE VALVE (MJxMJ)
1-CONC. THRUST BLOCK
STA:14+00.49, 0.00'
1-90° 10" BEND (MJ)
1-CONC. THRUST BLOCK
15' EASEMENT
15' EASEMENT
15' EASEMENT88 LF 10" DI CL52
10 LF 10" DI CL52
168 LF 10" DI CL52
93 LF 10" DI CL52
21.00
2
1
.
0
0
22.00
22
.
0
0
23
.
0
0
23
.
0
0
22.00
23.00
22.00
22.00
22.00
22.0022.00
PROTECT EXISTING
WATER METER AND
SERVICE LINE
PROTECT EXISTING
IRRIGATION METER
AND SERVICE LINE
1" WATER SERVICE AND RPBA BACKFLOW DEVICE
INSTALL 1" RPBA IN ABOVE GROUND ENCLOSURE
LOCATED IN PLANTER STRIP BEHIND NEW WATER
METER PER STD PLAN 360.1
SEE SHEET C5.2 FOR
FIRE SYSTEM PLAN
1" WATER SERVICE
PER COR STD PLAN 320.1
DROP-IN METER BY CITY FORCES.
DROP-IN METER PERMIT REQUIRED.
N 173834.31
E 1296191.97
EXISTING 10"
WATER MAIN
FIRE RISER LOCATION
SEE SHEET C5.2 FOR
FIRE SYSTEM PLAN
STA:10+23.32, 0.00'
10"x4" TEE (MJxFL)
4" GATE VALVE (FLxMJ)
10" GATE VALVE (MJxMJ)
1-CONC. THRUST BLOCK
CONNECT TO EXISTING 10"
WATER WITH 10" SLEEVE (MJ)
BY CITY FORCES
CONNECT TO EXISTING 10"
WATER WITH 10" SLEEVE (MJ)
BY CITY FORCES
STA:13+94.00, 0.00' RT
POLYPIGGING STATION
PER COR STD PLAN 300.7
EXISTING WATER MAIN TO BE ABANDONED IN PLACE.
CONTRACTOR TO COORDINATE WITH GEOTECHNICAL
ENGINEER FOR ALL PIPES PLANNED TO BE
ABANDONED UNDER BUILDING FOUNDATION.
5 LF 10" DI CL52
5 LF 10" DI CL52
18 LF 10" DI CL52
CAP EXISTING
WATER MAIN TO
BE ABANDONED.
CAP EXISTING
WATER MAIN TO
BE ABANDONED.
14
15
20
25
14
15
20
25
10+00
FG
2
1
.
5
1
FG
2
1
.
5
9
10+50
FG
2
1
.
4
7
FG
2
1
.
4
8
11+00
FG
2
1
.
5
4
FG
2
1
.
7
1
11+50
FG
2
1
.
8
5
FG
2
1
.
8
6
12+00
FG
2
1
.
7
2
FG
2
1
.
6
6
12+50
FG
2
1
.
7
4
FG
2
1
.
7
4
13+00
FG
2
1
.
7
0
FG
2
1
.
5
7
13+50
FG
2
1
.
5
9
FG
2
1
.
5
1
14+00
FG
2
1
.
4
7
14+10.49
FG
2
1
.
1
1
EXISTING 10" WATER MAIN,
CONTRACTOR TO POTHOLE
AND VERIFY DEPTH PRIOR TO
CONSTRUCTION.
8" STORM
CROSSING 8" STORM
CROSSING
6" STORM
CROSSING
FINISHED GRADE AT
WATER CENTERLINE
EXISTING GRADE AT
WATER CENTERLINE
FINISHED GRADE AT
WATER CENTERLINE
EXISTING GRADE AT
WATER CENTERLINE
STA: 10+41.46
CONNECT TO EXISTING
1-90° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA: 11+29.25
1-45° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA: 11+39.31
1-45° 10" BEND (MJ)
1-CONC. THRUST BLOCK
STA: 13+07.56
1-90° 10" BEND (MJ)
1-10" GATE VALVE (MJxMJ)
1-CONC. THRUST BLOCK
STA: 14+00.49
CONNECT TO EXISTING
1-90° 10" BEND (MJ)
1-CONC. THRUST BLOCK
10 LF 10" DI CL52
88 LF 10" DI CL52
168 LF 10" DI CL52 93 LF 10" DI CL52
EXISTING 10" WATER MAIN,
CONTRACTOR TO POTHOLE
AND VERIFY DEPTH PRIOR TO
CONSTRUCTION.1.5' MIN
1.5' MIN
STA: 10+23.32
10"x4" TEE (MJxFL)
4" GATE VALVE (FLxMJ)
10" GATE VALVE (MJxMJ)
1-CONC. THRUST BLOCK
5 LF 10" DI CL52
5 LF 10" DI CL52
18 LF 10" DI CL52
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
34
WATER PLAN C5.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
W
A
T
R
.
d
w
g
WATER PROFILE
SCALE: H:1"=20', V:1"=2'
EXISTING FIRE
HYDRANT
PROTECT
EXISTING FIRE
HYDRANT
HELD COMPUTED NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE,
GRID BEARING OF
NORTH 89°43'16" WEST BETWEEN A MONUMENT FOUND AT THE
INTERSECTION OF LIND AVE. SW AND SW 16TH ST., BEING CITY OF
RENTON CONTROL ID. 1895, TO A MONUMENT FOUND ON ALONG THE
NORTHERLY MARGIN OF SW 16TH ST. AT A BRIDGE CROSSING OF
SPRINGBROOK CREEK, BEING CITY OF RENTON CONTROL ID. 1891,
RESPECTIVELY.
NAD 83/91, WASHINGTON STATE PLANE, NORTH ZONE, AS DEFINED BY
THE CITY OF RENTON PUBLISHED HORIZONTAL CONTROL NETWORK
UNIT OF MEASUREMENT IS U.S. SURVEY FEET
ALL DISTANCES SHOWN ARE GROUND
A COMBINED GRID SCALE FACTOR OF 0.999987504615 (GRID TO GROUND)
WAS HELD AT CITY OF RENTON CONTROL ID. 1895
NAVD 88 (AS DEFINED BY THE PUBLISHED CITY OF RENTON VERTICAL
BENCHMARK NETWORK) (NGS2018 GEOID - USED)
BASIS OF BEARING
HORIZONTAL DATUM
VERTICAL DATUM
W-438801
WT
R
-
2
7
-
4
3
8
8
ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END (S)
SHALL HAVE A WEDGE-TYPE RETRAINER GLAND EQUAL TO MEGALUG
SERIES 110
WATER UTILITY NOTE
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GP
GP
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
E/C
E/C
COLUMN
17"
MAPLE
11"
MAPLE
14"
MAPLE
RA/W
6' CLF
6' CLF
GATE
25
4
.
8
8
'
75
.
2
0
'
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
B
L
D
G
A
D
D
I
T
I
O
N
F
F
:
2
1
.
9
5
EXISTINGBUILDING
FF: 21.95
22.0022
.
0
0
22
.
0
0
1 - FIRE DEPARTMENT
CONNECTION
PROVIDE APPROVED BALL
DRIP DRAIN AND DRAINAGE ROCK
N 173833.02
E 1296160.66
BLDGADDITION
DDCVA FIRE BACKFLOW ASSEMBLY SHALL BE
INSTALLED INSIDE THE BUILDING PER COR STD
DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52.
REFER TO FIRE PROTECTION NOTE ON SHEET C5.2
1 - PIV VALVE PER
COR STD DTL 360.5
N 173846.12
E 1296205.82
EXISTING FIRE
HYDRANT TO REMAIN
17LF 4" DI CL52
29LF 4" DI CL52 19LF 4" DI CL52
1 - 90° 4" BEND (MJ)
FIRE RISER
LOCATION
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
FIRE PROTECTION NOTES
35
FIRE SYSTEM PLAN C5.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
F
I
R
E
-
S
Y
S
M
-
P
L
A
N
.
d
w
g
THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND
CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A
FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE
FIRE PROTECTION SYSTEM, INCLUDING HYDRANT LOCATIONS, MAY
DEVIATE FROM THE SYSTEM SHOWN. THE FINAL DESIGN SHALL BE
SUBMITTED TO AND APPROVED BY THE FIRE MARSHALL. CONTRACTOR'S
BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION
ENGINEER'S DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL
FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY
"NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING
BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS.
1 FIRE SYSTEM ENLARGEMENT
FIRE SPRINKLER NOTE
WHERE THE UNDERGROUND WATER SUPPLY TEES OFF TO SERVE ONLY A FIRE
SPRINKLER SYSTEM, A SEPARATE DETAILED PLAN MUST BE SUBMITTED AND
APPROVED BY THE FIRE MARSHAL PRIOR TO INSTALLATION.
ALL WORK ON THE UNDERGROUND PORTIONS OF FIRE PROTECTION SPRINKLER
SYSTEMS AND/OR FIRE MAIN FOR HYDRANT PLACEMENT MUST BE INSTALLED AND
CERTIFIED BY A LICENSED CONTRACTOR WHO HAS ACHIEVED A STATE LEVEL "U"
CERTIFICATION. SUBCONTRACTING OF SUCH WORK TO PERSONS OR FIRMS NOT
CURRENTLY LICENSED AS A FIRE PROTECTION SPRINKLER SYSTEM CONTRACTOR IS
PROHIBITED UNDER WAC 212-80.
SEE SHEET C5.1 FOR
WATER SERVICE PLAN
SEE SHEET C5.1 FOR
WATER MAIN PLAN
W-438802
FIRE SYSTEM PIPING CANNOT BE
INSTALLED UNDER THE FLOOR SLAB.
PIPING MUST ENTER BUILDING AND BE
IMMEDIATELY TAKEN VERTICALLY UP
AND OVER TO THE SYSTEM
CONNECTION.
WT
R
-
2
7
-
4
3
8
8
EXISTING FIRE SPRINKLER NOTE
EXISTING FIRE SPRINKLER TO BE MAINTAINED UNTIL NEW FIRE SYSTEM IS
OPERATIONAL. CONTRACTOR TO COORDINATE SEQUENCING WITH RRFA AND COR
WATER UTILITY DURING DEMOLITIONS AND VERTICAL CONSTRUCTION.
SEE EXISTING FIRE
SPRINKLER NOTE
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
36WATER NOTES AND DETAILS
C5.3Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
W
A
T
R
.
d
w
g
1 NOT TO SCALE
1 INCH WATER SERVICE 3 NOT TO SCALE
REDUCED PRESSURE BACKFLOW ASSEMBLY
W-438803
WT
R
-
2
7
-
4
3
8
8
2 0.75 INCH TO 2 INCH RPBA
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
37WATER NOTES AND DETAILS
C5.4Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
W
A
T
R
.
d
w
g
1 NOT TO SCALE
WATER PLAN GENERAL NOTES
36
"
-
4
2
"
GRADE
2-1/2" FDC INLET WITH
LOCKING FDC CAPS
MANUFACTURED BY
KNOX PRODUCTS
TWO-WAY FREE STANDING CHROME-
PLATED FIRE DEPARTMENT CONNECTION
WITH 1" MIN. HIGH LETTERS "AUTO SPKR"
METAL ADDRESS PLATE WELDED ON POST OR
ATTACHED BY U-BOLT AND CHAIN, 24" MIN.
ABOVE GRADE AND 1" MIN. HIGH LETTERS.
18" X 18" X 8"
CONC. BLOCK
3 NOT TO SCALE
FIRE DEPARTMENT CONNECTION
W-438804
WT
R
-
2
7
-
4
3
8
8
2
CONNECTION TO WATER MAIN
EXISTING TEE OR END LINE CAP
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
38WATER NOTES AND DETAILS
C5.5Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
D
e
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
W
A
T
R
.
d
w
g
1 NOT TO SCALE
HORIZONTAL CONCRETE BLOCKING 2 NOT TO SCALE
VERTICAL CONCRETE BLOCKING
W-438805
WT
R
-
2
7
-
4
3
8
8
3 POLYPIGGING NEW WATER MAINS
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GPGP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
GP
P
P
GP
GP
S0
1
°
2
3
'
1
0
"
W
2
7
8
.
3
5
'
(
M
)
RAMP
C/C
C/C
C/C
C/C
RAMP
12"
MAPLE
12"
MAPLE
14"
MAPLE
8"
UNKNOWN
DECIDUOUS
DRIVEWAY
C/G
C/G
C/G
E/C
E/C
E/CE/C
E/C
E/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PART OF SURVEY
(TAX PARCEL NO. 3340404150)
NOT PART OF
SURVEY
(TAX PARCEL NO.
3340404150)
0.1'
4.9'
8.0'
6' CLF
6' CLF6' CLF ANGLE POINT
BEARS S84°11'E, 0.6'
FROM CALCULATED
LOT CORNER
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
E/C
E/C
E/C
E/C
5.1'
9.0'
8.2'
17.5'
3.1'
0.3'
10' CLF
GATE
0.3'
0.1'
3X8"
UNKNOWN
DECIDUOUS
GATE
E/C
E/C
6' CLF
6' CLF
6' CLF
STOP BAR
C/G
C/G
C/G
C/G
C/G
30.0'
DRIVEWAY
E/C
RA/W
RA/W
RA/W
RA/W
RA/W
RA/W
BUILDING FINISH FLOOR AT
CENTER OF PED. DOOR
LABELED "SPRINKLER ROOM"
ELEV=21.95' NAVD 88
BUILDING FINISH FLOOR AT
CENTER OF DOUBLE PED. DOOR
ELEV=22.03' NAVD 88
E/C
E/C
E/C
E/C
E/C
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
CONC.
CANOPY
COLUMN
GATE
GATE
GATE
4' CLF4' CLF
4' CLF
4' CLF
4' CLF
4' CLF
EDGE
CANOPY
(TYPICAL)
EDGE
CANOPY
(TYPICAL)
12"MAPLE
13"
MAPLE
17"
MAPLE
11"
MAPLE
14"
MAPLE
GATE 6' CLF
"STOP"
STEEL POST FOR
AERIAL
WALKER'S RENTON
SUBARU PARTS AND
SERVICE CENTER SIGN
SERVICE CENTER
DIRECTIONS SIGN
C/C
C/C
RAMP
E/C
C/C
C/C
RAMP
STEEL POST
FOR AERIAL
SUBARU SIGN
26.9'DRIVEWAY
C/G RA/W
6' CLF
6' CLF
6' CLF 6' CLF
6' CLF
6' CLF
6' CLF
GATE
6' CLF
FENCE TRANSITION
6' CLF/6' STEEL
6' STEEL
STORMWATER
DETENTION
POND
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF
8' CLF
8' CLF
8' CLF
8' CLF
8' CLF
6' CLF
4' CLF
0.7'
1.2'
4.4'
2.8'
1.5'
0.8'
0.8'
1.5'
1.4'
1.0'
2.1'
0.4'
0.9'
1.0'
0.9'
UNKNOWN USE
CLEANOUT
RIM=22.06'
UNKNOWN USE
CLEANOUT
RIM=21.96'
525.46'(C)
117.44'
S0
1
°
2
2
'
4
2
"
W
11
6
.
4
3
'
N77°26'10"
E
119.92'
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L1
8
L17
S0
9
°
3
9
'
1
5
"
E
10
5
.
0
4
'
L2
0
L2
1
N77°24'38"
E
123.29'
11
4
.
3
4
'
S86°20'10"W
391.52'
25
4
.
8
8
'
L1
0
L1
9
FND 1/2" REBAR AND CAP STAMPED
"LS 19635"
REBAR BEARS S88°24'33"E, 0.23'
FROM THE CALCULATED LOT CORNER
VISITED 11/18/2024
A/W
A/W
0.7'
0.9'
1.0'
0.8'
3-WAY 6' CLF
INTERSECTION
BEARS S15°13'E,
6.2'
8'/6' CLF INTERSECTION
BEARS S26°55'W, 0.8' FROM THE
CALCULATED LOT CORNERGATE
8'/6' CLF INTERSECTION
BEARS S79°15'W, 2.9' FROM THE
CALCULATED LOT CORNER
75
.
2
0
'
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
QWEST TELECOMMUNICATIONS EASEMENT
PER AFN 20030327000925
PRIVATE INGRESS/EGRESS EASEMENT
PER EASEMENT AGREEMENT WITH RIGHTS AND RESPONSIBILITIES
AFN 20020612000622
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
BUILDING FINISH
FLOOR AT CENTER OF
BAY DOOR
ELEV=21.94' NAVD 88
6' CLF ANGLE POINT
BEARS N53°23'W, 1.3' FROM CALCULATED LOT CORNER
8' CLF END BEARS N25°48'W, 1.0' FROM CALCULATED LOT
CORNER
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20010906002177, CITY OF RENTON ORDINANCE 4914
(ENCOMPASSES WHOLE VACATED ALLEY)
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
PSE ELECTRICAL
EASEMENT PER AFN
20030128002591
UTILITIES EASEMENT TO THE CITY OF RENTON
PER AFN 20020207002539, CITY OF RENTON ORDINANCE 4942
(ENCOMPASSES WHOLE VACATED STREET)
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
BLDG
ADDITION
TRANSFORMERS
PULL VAULT
PRIMARY PULL VAULT
NEW POLE LOCATION
REFER TO PSE PLANS
REFER TO PSE PLANS
FOR POWER RELOCATION
AND RECONNECTION
POWER VAULTS
REFER TO PSE PLANS
R13.00'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
UTILITY NOTES
39
COMPOSITE UTILITY PLAN C6.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
C
O
M
P
-
U
T
I
L
.
d
w
g
1.ALL SEWER, WATER, STORM DRAINAGE, AND GAS SHALL BE MARKED
WHERE THEY INTERSECT THE CURB WITH METAL TAGS EMBEDDED IN
THE FACE. REFER TO SECTION 3.08 OF THE CITY DEVELOPMENT
GUIDELINES AND PUBLIC WORKS STANDARDS. COORDINATE WITH CITY
INSPECTOR.
2.MAINTAIN 18" VERTICAL SEPARATION AT ALL WATER UTILITY CROSSINGS
3.UTILITIES PARALLEL TO WATER SHALL MAINTAIN A MINIMUM 10'
HORIZONTAL SEPARATION. NON-WATER UTILITIES PARALLEL TO EACH
OTHER SHALL MAINTAIN A MINIMUM 1' HORIZONTAL SEPARATION.
NEW POLE LOCATION
REFER TO PSE PLANS
POWER UNDERGROUNDING NOTES
1.LOCATION OF ALL POWER POLES, VAULTS AND CONDUIT ARE
PRELIMINARY. REFER TO PUGET SOUND ENERGY (PSE) PLANS FOR FINAL
LOCATIONS
2.REFER TO PSE PLANS FOR NOTES AND DETAILS REGARDING THE
INSTALLATION OF NEW POLES AND VAULTS.
3.REFER TO PSE PLANS FOR NOTES AND DETAILS REGARDING THE
REMOVAL OF EXISTING POLES AND OVERHEAD POWER LINES.
R-438828 S-438807 W-438806
WP
P
-
2
7
-
4
3
8
8
WT
R
-
2
7
-
4
3
8
8
05/15/2026
WASTEWATER UTILITY
Mbenoit 06/03/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
EXISTING
DETENTION
POND TO
REMAIN
22
22
22
22
23 23
23
23
21
21
22
22
22
2222
HB
HB
HB
HB
PER RMC 4-4-070 LANDSCAPING
(5) INTERIOR PARKING LOT LANDSCAPING
ONE TREE PER 6 PARKING SPACES
ONE SHRUB PER 20 SF OF LANDSCAPED AREA
MAX. 50% OF SHRUBS CAN BE DECIDUOUS
NO MORE THAN 50' BETWEEN PARKING STALLS
AND AN INTERIOR PARKING LOT LANDSCAPE AREA
PER RMC 4-4-070 STREET TREES
EXISTING STREET TREES TO BE RETAINED
GRAVEL GROUNDCOVER TO MATCH EXISTING
GROUNDCOVER ON SITE
X
X X X
REMOVE 4 TREES
EXISTING ESCALLONIA
SHRUB
EXISTING AZALEAS
5 EXISTING AZALEA
EXISTING ARBORVITAE
HEDGE ROW (APPROX 15' HT.)
TO BE RETAINED
241 SF
12 SHRUBS
NO PLANTINGS
DUE TO UTILITIES
254 SF
13 SHRUBS
NO TREE DUE TO UTILITIES
1
2
3
4
5
6
7
8
9
10
11
13
14
1512 16
EXISTING
CHERRY
REMOVE
PER RMC 4-4-070 STREET TREES
EXISTING STREET TREES TO BE RETAINED
975 SF LS
407 SF LS
843 SF LS
104 SF LS
297 SF LS
1,649 SF LS
X
X
LANDSCAPE PLAN N
PLANT LEGEND
TREES
SYMBOL QTY DESCRIPTION SIZE MATURE HT TREE CREDITS
2 Tilia cordata 'Chancellor'
Chancellor Littleleaf Linden (Large -2 pts ea)
2" Cal. Min.
Well-Formed 40 4
5 Aesculus hippocastanum ‘ Baumannii’
Fruitless Horsechestnut (Large - 2 pts)
2" Cal. Min.
Well-Formed 55 10
TOTAL NEW TREE POINTS 14
TOTAL EXISTING PRESERVED TREE POINTS 49
TOTAL TREE POINTS 63
SHRUBS
SYMBOL QTY DESCRIPTION SIZE
9 Pennisetum alopecuroides 'Hameln'
Hameln Fountain Grass 1 Gal. Min.
16 Potentilla fruticosa 'Goldfinger'
Goldfinger Cinquefoil 3 Gal. Min.
NOTE:
1.SEE SHEET L2 FOR CITY OF RENTON TREE RETENTION AND CREDIT WORKSHEET
2.ALL PLANT SELECTIONS ARE DROUGHT TOLERANT AND DO NOT REQUIRE PERMANENT
IRRIGATION
NOTE:
1.THERE IS NO WORK PROPOSED NEAR EXISTING TREES TO BE RETAINED - NO
ADDITIONAL TREE PROTECTION IS NECESSARY
2.30% SIGNIFICANT TREES SHALL BE RETAINED; 56% PROPOSED RETAINED
TREE INVENTORY
NO SPECIES DBH HEALTH RETAIN REMOVE
1 PRUNUS (FLOWERING CHERRY)8 FAIR X
2 MAPLE 14 FAIR X
3 MAPLE 12 FAIR X
4 MAPLE 12 FAIR X
5 MAPLE 12 FAIR X
6 MAPLE 13 FAIR X
7 MAPLE 12 FAIR X
8 MAPLE 13 FAIR X
9 MAPLE 17 FAIR X
10 MAPLE 11 FAIR X
11 MAPLE 14 FAIR X
12 PRUNUS (FLOWERING CHERRY)8 FAIR X
13 PRUNUS (FLOWERING CHERRY)6 FAIR X
14 PRUNUS (FLOWERING CHERRY)7, 6 FAIR X
15 PRUNUS (FLOWERING CHERRY)6, 5 FAIR X
16 PRUNUS (FLOWERING CHERRY)6, 5 FAIR X
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
Know what's below.
before you dig.Call
R
C26
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438829
55LANDSCAPE PLAN 40
L1
1:30
ON SITE LANDSCAPING CALCULATIONS
254
241
1649
297
975
407
843
104
4,770 SF
SITE AREA: 91,368 SF
2.5% LS REQ'D 2,284.2 SF
PROVIDED: 4,770 SF
030 30 6015
TE
D
-
4
0
-
4
3
8
8
AMorganroth
06/03/2026
CURRENT PLANNING DEVELOPMENT ENGINEERING
msippo 06/05/2026
34"
6" FROM BASE
OF BRANCHING
1.5"
12"
2 X BALL DIA.
ENSURE PROPER SUBBASE
EXISTS; CLEAR ALL
CONCRETE AND OTHER
DEBRIS FROM PLANTERS
PRIOR TO BACKFILLING
AND PLANTING
NOTES:
1. PLANTING BACKFILL:
50% EXISTING SOIL, 50% 1/4 MINUS
COMPOST, MIXED THOROUGHLY
2. FOR MULCH TYPE SEE
LANDSCAPE NOTES.
3. IF B&B AND BURLAP IS
GREEN IN COLOR. REMOVE COMPLETELY
BEFORE INSTALLING PLANT.
DECIDUOUS TREE PLANTING &
STAKING DETAIL
No Scale
WHEN PLANTING ON STEEP SLOPE,
MAINTAIN PLANT IN VERTICAL
POSITION WITHIN PLANTING PIT.
MAKE A RIM ON DOWNSLOPE SIDE OF
PLANT PIT TO RETAIN WATER,
DECIDUOUS TREE
INTERLOCKING PLASTIC TREE TIES
OR AGENCY APPROVED EQUAL
(2) 2x2 OR 2" DIA. WOOD STAKES
DRIVEN INTO SUBGRADE OR SIM.
METHOD
FORM SAUCER WITH
CONTINUOUS RIM
TOP SOIL OR AMENDED BASE, REFER
TO LANDSCAPE NOTES FOR DEPTH
WHEN B&B REMOVE ALL
WIRE AND ROLL BURLAP
OFF TOP OF ROOTBALL
SCARIFY SIDES OF PIT,
BACKFILL WITH SOIL
MIXTURE INDICATED IN THE NOTES IN
9" LAYERS. WATER AND TAMP TO
REMOVE AIR POCKETS
3" MULCH
GENERAL LANDSCAPE NOTES
1.Contractor is responsible for obtaining all necessary permits from the appropriate agency prior to commencing work.
Contractor shall contact Line Locators (811) a min. of 48 hours prior to any digging or trenching. If there are any
discrepancies with existing lines and landscaping, it is the contractor's responsibility to contact the landscape architect and
request a site visit to address the conflicts. Contractor shall comply and conform to any and all local and state codes for
work, schedules and any other project related requirements.
2.Contractor shall coordinate directly with the landscape architect for all landscape related issues, concerns, inspections and
approvals. Contractor shall provide the landscape architect with a written request for a site visit to address any related items.
3.Scope of work shall include any and all specified and unspecified but related incidental work to achieve the design indicated
on the landscape plans. All labor, materials, subcontractors, equipment, and related incidental items shall be supplied and
installed to achieve a complete project, unless directed otherwise by the general contractor or landscape architect.
4.Contractor to verify all sub grades are set below required amendments to insure the finished grade will match what is
intended by civil or drainage design. All sub grades and finished or final grades shall be graded to drain to the designed
drainage system with positive drainage away from all structures.
5.Grade Preparation:
a.Slopes used for grass plantings or turf shall be less than 3:1 or 33 percent. Otherwise plantings should not require
mechanized mowing equipment. Any invasive / toxic vegetation shall be removed and treated with herbacide (hand
applied to minimize treatment to specific plant) prior to any new planting. Native vegetation shall not be disturbed.
Soil Preparation.
a.Where soils are compacted and in informal grassy play areas, planting beds should be deep tilled to a depth of at least 12
inches. Soils shall be enhanced through the addition of the following materials: bark and forestry by-products, organic
matter such as composted yard waste, organics and other amendments as needed through a soils test. Soils that meet a
balanced PH between 6-8PH, do not required amending. Where Pit Planting, see planting detail for planting ring sizes
and depths. Scarify the edges of planting pits to encourage root expansion.
b.On project sites where topsoil is limited or nonexistent, a minimum depth of 6 (six) inches of sandy loam topsoil should be
tilled into the soil to a depth of 12 inches through all planting areas with compacted soils.
c.For all newly planted areas, three cubic yards of composted organic matter per 1,000 square feet of landscape area
should be added to a depth of four inches to the top of the soil and Tilled in.
d.Seeded areas shall be fine graded and rolled. New Soil depths in lawn areas shall be 4 Inches.
e.Native undisturbed areas with new trees shall be pit planted per tree planting details.
f.In order to utilize on site Top Soil, contractor shall submit a soil test showing the PH (acid) level of existing Top Soil on
site. A ziploc type bag of soil can be delivered to Spectra Lab in the Tacoma Tideflats - 2221 Ross Way, Tacoma, WA
98421 or a similar testing lab to measure PH level in soils.
6. Mulching of Newly Planted or Replanted Areas.
a.Mulches must be applied to the following depths: a minimum 3 (three) inches over bare soil, and two inches where plant
materials will cover.
b.Mulches must include organic materials, such as wood chips and shredded bark.
c.Nonporous materials, such as plastic sheeting, shall not be used in any area of the landscape because of down-slope
erosion and potential soil contamination from herbicide washing.
d.Mulch should be applied regularly to and maintained in all planting areas to assist soils in retaining moisture, reducing
weed growth, and minimizing erosion.
7. Contractor shall field layout all plant material and contact the landscape architect for a site visit to approve the layout. Any
field modifications shall be done by the landscape architect prior to planting.
8. Contractor shall immediately notify the landscape architect of any poor drainage condition in landscape areas. No standing
water shall be permitted in any landscape areas - either on the surface or below the topsoil. The landscape architect shall
coordinate the drainage solution with the general contractor and civil engineer. Once the concerns have been remedied planting
shall commence.
9. All groundcover to be planted in a triangular spacing formation, equal in all directions to the centers of the groundcovers in
distances indicated in the legend. Contractor shall verify all quantities of groundcovers by area calculations and spacing
requirements.
10. Landscaping is to be per plan. Plant substitutions due to availability or otherwise will be allowed only with landscape
architect, owner and agency approval. Any substitutions will be with material of similar size, growth characteristics, and quality.
11. All trees must be staked as necessary so as to maintain material in a healthy, vigorous growing condition.
12. Landscaping shall be installed in a professional workmanlike manner that is consistent and accepted throughout the
industry. All landscape and irrigation work shall be performed by experienced persons familiar with scope of project.
13. All landscape material and labor is to be guaranteed for a period of one full year from the time of completion.
14. When planting 'Balled and Burlapped' product, remove all burlap, string & wire from any B&B plant material, cut and remove
jute strings. Gently place in tact Rootbal into planting pit. If rootball breaks or is not solid - the plant is unacceptable and shall
be replaced.
15. Street trees shall be high branching with canopy that starts at least 6' above finish grade.
16. All plant I.D. tags are to remain on the plant material until final inspection has been completed. Once approved all plant I.D.
tags shall be removed and discarded appropriately.
17. Trees shall be cared for in accordance with the American National Standards Institute (ANSI) standard practices for trees,
shrubs and other woody plant maintenance (ANSI 300) in order to allow them to reach there mature height and form.
18. Pruning of street trees shall be performed per the ANSI 300 standards so as to maintain the natural form of the tree,
encourage vigorous growth to a mature spread and height, and avoid weakening the tree to create a hazard. Street trees shall
not be topped pollarded, or otherwise pruned in a manner contrary to these goals, unless there is no practicable alternative that
would preserve essential utility services.
19.Plant material selected is drought tolerant or native species. The project proponent (property Owner) shall be
responsible for maintaining and watering all plant material throughout the first growing season and in times of
drought.
Temporary irrigation shall be provided via TREE GATOR BAGS attached to each tree. The bags shall be filled
when 14 empty - approximately 1 time per week and as needed during drought months. The bags will remain on
the trees for the establishment period of two summer seasons, after which, bags shall be removed by the owner.
Owner may elect to have the contractor hired to water and warranty the plants for the establishment period. For
planting warranties from contractor to be ensured, contractor shall be responsible for watering the plant material
and keeping the mulch ring weed free for the first growing season as part of the contract.
It is recommended to install the landscaping in the Spring (February - April) or Fall (October - December)when dormant but
before hard freeze.
TEMPORARY IRRIGATION
The project proponent shall ensure that a minimum of one (1) inch of water is supplied each week to the restoration area
between May 1 and October 15 for a least the first two years following initial planting. The calculated amount of required
water shall include both natural rainfall and temporary irrigation.
TEST HOLE
FINISHED GRADE
MULCH
LOOSE SOIL
WITH VISIBLE DARK
ORGANIC MATERIAL
LOOSE OR FRACTURED
SUBSOIL
NOTE: TEST HOLSE SHOULD BE ABOUT 1 FOOT DEEP
(AFTER FIRST SCRAPING AWAY OF ANY MULCH) AND BE
ABOUT 1 FOOT DEEP
SURFACE PREPARATION:
1.TILL THE SUB GRADE SOIL TO AN 8 INCH DEPTH. THOSE AREAS SUBJECTED
TO VEHICLE TRAFFIC SHALL BE TILLED TO A DEPTH OF 12 INCHES. DO NOT
SCARIFY OR TILL WITHIN THE DRIP LINE OF EXISTING TREES THAT WILL BE
RETAINED.
2.PLACE 3 INCHES OF COMPOST MATERIAL AND TILL INTO 5 INCHES OF SOIL
(A TOTAL AMENDED DEPTH OF ABOUT 9.5 INCHES FOR A SETTLED DEPTH
OF 8 INCHES).
3.RAKE THE AREA SMOOTH AND REMOVE SURFACE ROCKS LARGER THAN
1INCH IN DIAMETER.
4.PLACE 2 INCHES OF GRADE AA COMPOST AND RAKE.
COMPOST AMENDMENT QUALITY STANDARDS:
1.THE ORGANIC CONTENT FOR THE 'PRE-APPROVED' AMENDMENT RATES
CAN BE MET ONLY BY USING COMPOST THAT MEETS THE DEFINITION FOR
'COMPOSTED MATERIALS' IN WAC 173-350-220.
2.THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 35 TO
65 PERCENT AND A CARBON TO NITROGEN RATION BELOW 25:1
3.THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS
COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND
LOWLANDS REGION.
PREPARATION FOR INSPECTION:
1.PROVIDE SIX HOLES PER SITE; ALL HOLES SHALL BE EVENLY PLACED
THROUGHOUT THE SITE TO DEMONSTRATE AUGMENTATION HAS BEEN
COMPLETED.
2.TEST HOLES SHALL BE A MINIMUM OF 1 FOOT DEEP AND 1 FOOT SQUARE.
3.CONTRACTOR SHALL PROVIDE DOCUMENTS FOR THE GRADE AA COMPOST
VOLUME DELIVERED TO THE SITE TO CONFIRM THE COMPOST ORIGIN AND
QUALITY.
INSPECTION VERIFICATION:
1.2 INCHES OF COMPOST ON ALL DISTURBED SURFACES.
2.LOOSE SOIL FOR 8 INCHES WITH VISIBLE DARK ORGANIC MATTER.
3.LOOSE FRACTURED SUB SOILS SHOULD NOT BE EASY TO PENETRATE WITH
A SHOVEL. 4 INCHES BELOW THE 8 INCHES. TOTAL DEPTH OF AUGMENTED
AND LOOSENED SOIL SHALL BE 12 INCHES.
COMPOST AMENDED SOIL PER BMP T5.13
8" DEPTH
12" DEPTH FOR
VEHICLE TRAFFIC AREAS
2 X BALL DIA.
NOTES:
1. PLANTING BACKFILL:
50% EXISTING SOIL, 50% 1/4 MINUS
COMPOST, MIXED THOROUGHLY
2. FOR MULCH TYPE SEE
LANDSCAPE NOTES.
3. IF B&B AND BURLAP IS
GREEN IN COLOR. REMOVE COMPLETELY
BEFORE INSTALLING PLANT.
SHRUB PLANTING DETAIL
No Scale
WHEN PLANTING ON A STEEP SLOPE,
MAINTAIN PLANT IN VERTICAL
POSITION WITHIN PLANTING PIT.
MAKE A RIM ON DOWNSLOPE SIDE OF
PLANT PIT TO RETAIN WATER.
MULCH TO DEPTH
SPECIFIED IN NOTES
FORM CONTINUOUS RIM
BACKFILL W/ BACKFILL MIXTURE AS
INDICATED IN NOTE IN 9" LAYERS.
WATER AND TAMP TO REMOVE AIR POCKETS
REMOVE ALL WIRE WRAP
AND PLASTIC WRAP.
REMOVE BURLAP FROM
TOP OF ROOT BALL
MULCH & TOPSOIL OR AMENDED BASE,
REFER TO LANDSCAPE NOTES FOR DEPTH
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438830
55LANDSCAPE DETAILS & NOTES 41
L2
N.T.S.
PAGE 3 N/A PER PAGE 1
TE
D
-
4
0
-
4
3
8
8
AMorganroth
06/03/2026
CURRENT PLANNING DEVELOPMENT ENGINEERING
msippo 06/05/2026
SE
N
E
C
A
A
V
E
S
W
SW 12TH
S
T
SW 13TH
S
T
INTERSTATE 405
BLDG ADDITION
FF: 21.95
EXISTING
BUILDING
FF: 21.95
EXISTING
DETENTION
POND TO
REMAIN
22
22
22
22
23 23
23
23
21
21
22
22
22
2222
HB
HB
HB
HB
NEW ZONES RUN FROM BATTERY
OPERATED TIMES ON HOSE BIBS
FOR TEMPORARY IRRIGATION DURING
ESTABLISHMENT PERIOD
1
2
IRRIGATION WATER
POINT OF CONNECTION
CREATE 3' DIAMETER DRIP LINE RING AROUND EACH TREE, TYP.
IRRIGATION PLAN N
NOTE: THERE IS NO WORK PROPOSED NEAR
EXISTING TREES TO BE RETAINED - NO
ADDITIONAL TREE PROTECTION IS NECESSARY
VALVE SCHEDULE
NO.GPM SIZE AREA TYPE OF ZONE
1 2.52 1"SHRUB MP ROTATOR
2 2.52 1"SHRUB MP ROTATOR
NOTE: ADD ZONES TO EXISTING SYSTEM ONLY IF NEEDED,
EXPAND ZONES WHERE POSSIBLE
IRRIGATION LEGEND
CATALOG NUMBER SYMBOL DESCRIPTION PSI RADIUS GPM
1800 SAM PRS B 25
NETAFIM OR SIM. DRIP LINE 24"
SPACE AND 24" SPACE
EMMITTERS
30 2'
ICV SERIES ORBIT OR SIM. BATTERY OPERATED HOSEBIB CONTROLLER
2 STATION MIN. NEED (2)
SCH 40 SOLVENT WELD PVC MAIN LINE, SIZE AS SHOWN
CL 200 SOLVENT WELD PVC LATERALS, SIZE AS SHOWN
SCH 40 SOLVENT WELD PVC SLEEVING, SIZE AS SHOWN
IRRIGATION NOTES
1.IRRIGATION SYSTEM ENGINEERING BASED TEMPORARY HOSE BIB BATTERY OPERATED
CONNECTIONS. THE INSTALLER TO VERIFY ADEQUATE STATIC WATER PRESSURE AT TIME OF
INSTALLATION.
2.IRRIGATION LINES ARE THAT ARE SHOWN WITHIN HARD SURFACE AREAS FOR CLARITY, SHALL BE
LOCATED WITHIN LANDSCAPE PLANTING AREAS OR UNDERGROUND SLEEVES. ALL VALVES SHALL BE
INSTALLED WITHIN PROTECTIVE BOXES INSTALLED FLUSH AND LEVEL WITH FINISHED GRADE.
3.INSTALL ALL EQUIPMENT PER STATE AND LOCAL CODES. CALL LINE LOCATERS PRIOR TO DIGGING
AT 1-800-424-5555. THE INSTALLER SHALL BE RESPONSIBLE FOR ALL PERMITS, TESTS AND
INSPECTIONS AS REQUIRED.
4.SEE CIVIL DRAWINGS TO VERIFY ALL UTILITY LOCATIONS.
5.INSTALL MANUAL DRAINS AT ALL LOW POINTS AND RECORD ALL LOCATIONS ON THE "RECORD
DRAWINGS".
6.ADJUST RADIUS ON ALL SPRINKLER HEADS TO MAXIMIZE THE COVERAGE AND MINIMIZE OVERSPRAY
ON ALL HARD SURFACES. ADD ANTI-DRAIN CHECK VALVES TO LOW HEADS TO ELIMINATE DRAINAGE
AND RUN-OFF.
7.MAINLINE & WIRING TO HAVE A MINIMUM COVER OF 18" AND ALL LATERAL PIPING 12".
8.PRIOR TO BACKFILL, THE MAIN LINE IS TO BE PRESSURE TESTED AT 75 LBS. FOR (1) ONE HOUR WITH
'0' LOSS. THE COMPLETED TEST IS TO BE TURNED OVER TO THE GENERAL CONTRACTOR.
9.USE SELECT "ROCK FREE" NATIVE SOIL OR CLEAN SAND TO BACKFILL ALL TRENCHES AND COMPACT
TO 85% DENSITY FOR LANDSCAPE AREAS AND 95% FOR AREAS UNDER CONCRETE OR ASPHALT.
10.THE BACK FLOW ASSEMBLIES ARE TO BE CERTIFIED BY A STATE LICENSED BAT. THE COMPLETED
FORMS ARE TO BE TURNED IN TO WATER PURVEYOR AND AGENCY. AND A COPY OF THE
CERTIFICATION SHALL BE DELIVERED TO THE PROJECT PROPONENT.
11.DO NOT SPICE THE RED SIGNAL WIRE BETWEEN THE CONTROLLER AND THE CONTROL VALVE. WIRE
SPLICES SHALL BE WITHIN THE VALVE BOXES ONLY USING 3M-DBY SPLICE KITS.
12.ALL CONTROL VALVES SHALL BE TAGGED USING PLASTIC MARKING NUMBERS. NUMBER VALVES AS
PER PLAN.
13.THE INSTALLER SHALL PROVIDE TO THE OWNER AN EXACT 'AS-BUILT' DRAWING OF THE INSTALLED
SYSTEM
I.IRRIGATION REQUIREMENTS:
1.Irrigation and Automatic Controller:
a.A permanent built-in irrigation system with an automatic controller shall be installed, used,
and maintained in working order in all landscaped areas of industrial, commercial, and multi-family
development, and landscaped common areas in single family subdivisions.
b.The irrigation system shall provide full water coverage of the planted areas as specified in
the plan.
c.The irrigation system maintenance program shall include scheduled procedures for
winterization.
2.Exceptions for Drought Tolerant Plants: Landscape plans featuring one hundred percent
(100%) drought-tolerant plants or landscaping already established without irrigation systems are
exempt from installation of a permanent irrigation system, but drought tolerant proposals must
provide supplemental moisture by means of a City-approved temporary irrigation system for a
period not less than two (2) years. The Administrator shall have the option of conditioning the
approval (i.e., requiring a screening fence, etc.). An inspection will be required one year after final
inspection to ensure that the landscaping has become established. An inspection fee, paid at the
time of permit application, will be required and the fee amount will be determined by the
Administrator. (Ord. 5676, 12-3-2012)
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
Know what's below.
before you dig.Call
R
C26000638
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
R-438831
55IRRIGATION PLAN 42
L3
1:30
030 30 6015
TE
D
-
4
0
-
4
3
8
8
AMorganroth
06/03/2026
CURRENT PLANNING DEVELOPMENT ENGINEERING
msippo 06/05/2026
GP
GP
GP
GP GP GP GPGP
GP
GP GP
GP GP
GP
GP GP
S01°23'10"W 278.35'(M)
C/
G C/
C
RA
M
P
RA
M
P
C/
C
C/
C
C/
C
C/
C
RA
M
P
12
"
MA
P
L
E
12
"
MA
P
L
E
C/
G
C/
G
E/
C
E/
C
"S
T
O
P
"
ST
O
P
B
A
R
C/
G
C/
G
C/
G
C/
G
C/
G
C/C
C/
C
30
.
0
'
DR
I
V
E
W
A
Y
E/
C
RA
/
W
RA
/
W
RA
/
W
RA
/
W
RA
/
W
E/
CE/
C
E/
C
E/
C
E/
C
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
GA
T
E
GA
T
E
GA
T
E
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
ED
G
E
CA
N
O
P
Y
(T
Y
P
I
C
A
L
)
ED
G
E
CA
N
O
P
Y
(T
Y
P
I
C
A
L
)
12
"MA
P
L
E
13
"
MA
P
L
E
12
"
MA
P
L
E
13
"MA
P
L
E
17
"MA
P
L
E
11"MA
P
L
E
14
"MA
P
L
E
GA
T
E
6'
C
L
F
"S
T
O
P
"
ST
E
E
L
P
O
S
T
F
O
R
AE
R
I
A
L
WA
L
K
E
R
'
S
R
E
N
T
O
N
SU
B
A
R
U
P
A
R
T
S
A
N
D
SE
R
V
I
C
E
C
E
N
T
E
R
S
I
G
N
S
E
R
V
I
C
E
C
E
N
T
E
R
DI
R
E
C
T
I
O
N
S
S
I
G
N
E/
C
C/
C
C/
C
RA
M
P
ST
E
E
L
P
O
S
T
FO
R
A
E
R
I
A
L
SU
B
A
R
U
S
I
G
N
E/
C
26
.
9
'
DR
I
V
E
W
A
Y
C/
G C/
G
GA
T
E
RA
/
W
6'
C
L
F
6'
C
L
F
6'
C
L
F
6'
C
L
F
GA
T
E
6'
C
L
F
FE
N
C
E
T
R
A
N
S
I
T
I
O
N
6'
C
L
F
/
6
'
S
T
E
E
L
6'
S
T
E
E
L
254.88'
L9
L10
L1
1
0.7
'
0.9
'
3-
W
A
Y
6
'
C
L
F
IN
T
E
R
S
E
C
T
I
O
N
BE
A
R
S
S
1
5
°
1
3
'
E
,
0.
6
'
F
R
O
M
T
H
E
CA
L
C
U
L
A
T
E
D
L
O
T
CO
R
N
E
R
75.20'
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
SENECA AVE SW
S
W
1
2
T
H
S
T
S
W
1
3
T
H
S
T
1
5
+
0
0
1
6
+
0
0
PI: 15+46.08
106+00 107+00 108+00
109+00
110+00
PI
:
1
0
6
+
8
8
.
0
6
PI
:
1
0
9
+
6
6
.
4
1
SENECA AVE SW STA: 109+66.41 =
SW 12TH ST STA: 15+46.08
N
7
7
°
2
7
'
5
1
"
E
5
4
6
.
0
8
'
N
7
7
°
2
7
'
4
4
"
E
9
8
8
.
6
6
'
N1° 23' 10"E
278.35'N1° 27' 14"E
300.84'
GP
GP
GP
GP GP GP GP
GP GP
GP GP
GP
GP GP
S01°23'10"W 278.35'(M)
C/
G
C/
G
E/
C
E/
C
C/
C
C/
C
RA
M
P
RA
M
P
C/
C
C/
C
C/
C
C/
C
RA
M
P
12
"
MA
P
L
E
12
"
MA
P
L
E
C/
G
C/
G
E/
C
E/
C
"S
T
O
P
"
ST
O
P
B
A
R
ST
O
P
B
A
R
C/
G
C/
G
C/
G
C/
G
C/
G
30
.
0
'
DR
I
V
E
W
A
Y
E/
C
RA
/
W
RA
/
W
RA
/
W
RA
/
W
RA
/
W
E/
CE/
C
E/
C
E/
C
E/
C
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
CO
N
C
.
CA
N
O
P
Y
CO
L
U
M
N
GA
T
E
GA
T
E
GA
T
E
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
4'
C
L
F
ED
G
E
CA
N
O
P
Y
(T
Y
P
I
C
A
L
)
ED
G
E
CA
N
O
P
Y
(T
Y
P
I
C
A
L
)
12
"MA
P
L
E
13
"MA
P
L
E
17
"MA
P
L
E
11
"MA
P
L
E
14
"MA
P
L
E
GA
T
E
6'
C
L
F
"S
T
O
P
"
ST
E
E
L
P
O
S
T
F
O
R
AE
R
I
A
L
WA
L
K
E
R
'
S
R
E
N
T
O
N
SU
B
A
R
U
P
A
R
T
S
A
N
D
SE
R
V
I
C
E
C
E
N
T
E
R
S
I
G
N
S
E
R
V
I
C
E
C
E
N
T
E
R
DI
R
E
C
T
I
O
N
S
S
I
G
N
E/
C
C/
C
C/
C
RA
M
P
ST
E
E
L
P
O
S
T
FO
R
A
E
R
I
A
L
SU
B
A
R
U
S
I
G
N
26
.
9
'
DR
I
V
E
W
A
Y
C/
G
RA
/
W
6'
C
L
F
6'
C
L
F
6'
C
L
F
GA
T
E
6'
C
L
F
FE
N
C
E
T
R
A
N
S
I
T
I
O
N
6'
C
L
F
/
6
'
S
T
E
E
L
6'
S
T
E
E
L
17
"
MA
P
L
E
254.88'
L9
L10
L1
1
0.7
'
0.9
'
3-
W
A
Y
6
'
C
L
F
IN
T
E
R
S
E
C
T
I
O
N
BE
A
R
S
S
1
5
°
1
3
'
E
,
0.
6
'
F
R
O
M
T
H
E
CA
L
C
U
L
A
T
E
D
L
O
T
CO
R
N
E
R
75.20'
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
SENECA AVE SW
S
W
1
2
T
H
S
T
S
W
1
3
T
H
S
T
1
5
+
0
0
16
+
0
0
PI: 15+46.08
106+00 107+00 108+00
109+00
110+00
PI
:
1
0
6
+
8
8
.
0
6
PI
:
1
0
9
+
6
6
.
4
1
SENECA AVE SW STA: 109+66.41 =
SW 12TH ST STA: 15+46.08
N
7
7
°
2
7
'
5
1
"
E
5
4
6
.
0
8
'
N7
7
°
2
7
'
4
4
"
E
9
8
8
.
6
6
'
N1° 23' 10"E
278.35'N1° 27' 14"E
300.84'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
DEMOLITION NOTES
43
SENECA AVE SW FRONTAGE
IMPROVEMENTS
CR1.1Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
S
E
N
E
C
A
.
d
w
g
1.CONTRACTOR IS TO VERIFY LOCATION AND DEPTH OF ALL UTILITIES SHOWN.
THE CONTRACTOR IS TO PROTECT UNDERGROUND UTILITIES DURING
CONSTRUCTION.
2.CONTRACTOR TO PROTECT EXISTING STORM SYSTEM LOCATED IN FRONTAGE
ALONG EAST VALLEY ROAD.
3.CONTRACTOR TO PROTECT EXISTING CURB AND GUTTER LOCATED IN
FRONTAGE ALONG SENECA AVE SW.
PROPERTY BOUNDARY
ROAD CENTERLINE
RIGHT OF WAY BOUNDARY
ASPHALT PAVING
PROPOSED SIDEWALK
EXISTING SIDEWALK
EXISTING TREE
EXISTING GAS LINE
EXISTING COMMUNITCATION LINE
EXISTING WATER LINE
EXISTING SEWER LINE
EXISTING OVERHEAD POWER
EXISTING STORM
1.ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN
THE RENTON STANDARD PLANS AND SPECIFICATIONS.
2.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. THE
CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION AND DEPTH OF ALL
UTILITIES SHOWN.
3.CONTRACTOR IS TO RAISE ALL REMAINING STRUCTURE LIDS TO BE FLUSH
WITH FINISHED GRADE. REFER TO PLAN FOR REMAINING STRUCTURES.
4.ALL IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY SHALL CONFORM TO
CITY OF RENTON CONSTRUCTION STANDARDS.
DEMOLITION PLAN
IMPROVEMENTS PLAN
FRONTAGE IMPROVEMENT NOTES
FRONTAGE IMPROVEMENT LEGEND
PROPERTY BOUNDARY
ROAD CENTERLINE
RIGHT OF WAY BOUNDARY
ASPHALT PAVING
EXISTING SIDEWALK
EXISTING TREE
EXISTING GAS LINE
EXISTING COMMUNITCATION LINE
EXISTING WATER LINE
EXISTING SEWER LINE
EXISTING OVERHEAD POWER
EXISTING STORM
DEMOLITION LEGEND
PROTECT EXISTING CATCH BASIN
PROTECT EXISTING
CATCH BASIN
TYPE C1 CONCRETE DRIVEWAY,
SEE SHEET CR1.3 FOR
GRADING ENLARGEMENT
SAWCUT ALONG EXISTING GUTTER
REMOVE EXISTING
DRIVEWAY, CURB
AND GUTTER
SAWCUT ALONG EXISTING GUTTER
REMOVE EXISTING DRIVEWAY,
CURB AND GUTTER
INSTALL DETECTABLE
WARNING SURFACE ON
EXISTING RAMPS 4
CR1.5
3
CR1.5
TYPE C1 CONCRETE DRIVEWAY,
SEE SHEET CR1.3 FOR
GRADING ENLARGEMENT
3
CR1.5
R-438832
REMOVE 8" SEWER AND PLUG
AT MANHOLE ONCE NEW
BUILDING SERVICE IS ONLINE
PAVEMENT PATCH PER
COR STD DTL 110.1
3
CR1.6
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
GP
GP
GP
GP
GP GP GP GP GP
N77°27'44"E 988.66'(C)
C/G
C/G
E/C
C/C
C/C
RAMP
RAMP C/C
C/C
C/C
C/C
RAMP 12"MAPLE
12"MAPLE
14"MAPLE
8"UNKNOW
N
DECIDUO
U
S
C/C C/C31.3'DRIVEWAY
C/GC/GC/G
C/G
E/C
E/C
E/C
E/CE/C
E/C
C/G C/C
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PAR
T
O
F
S
U
R
V
E
Y
(TAX PAR
C
E
L
N
O
.
3
3
4
0
4
0
4
1
5
0
)
23.9'DRIVEWAY
20.6'
DRIVEWAY 24.2'
DRIVEWAY
C/C
ASPHALT
RAMP
C/GC/G
C/G
E/CE/C
A/W A/W
GATE
GATE
GATE
C/C
C/C
GATE
0.5'
0.4'
4.9'8.0'
6' CLF
7' CLF
7' CLF
0.2'0.3'0.2'
7' CLF
6' CLF
6' CLF
6' CLF
6' CLF
6' CLF AN
G
L
E
P
O
I
N
T
BEARS S
8
4
°
1
1
'
E
,
0
.
6
'
FROM C
A
L
C
U
L
A
T
E
D
LOT COR
N
E
R
6'/7' CLF
A
N
G
L
E
P
O
I
N
T
BEARS N
8
9
°
5
0
'
E
,
0
.
6
'
FROM C
A
L
C
U
L
A
T
E
D
LOT COR
N
E
R
14.4'
"STOP"
STOP BA
R
STOP BA
R
C/G
C/C
30.0'DRIVEWAY
E/C
"STOP"
STEEL P
O
S
T
F
O
R
AERIAL
WALKER'
S
R
E
N
T
O
N
SUBARU
P
A
R
T
S
A
N
D
SERVICE
C
E
N
T
E
R
S
I
G
N
UNKNOW
N
U
S
E
CLEANOUT
RIM=21.96'
17"MAPLE 237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L16GPGP
P
C/G
C/G
C/C C/C
14.9'
DRIVEWAY
GATE
E/CE/C
15"UNKNOWN
DECIDUOU
S
13"
UNKNOW
N
DECIDUOU
S
15"UNKNOW
N
DECIDUO
U
S
CONC. STE
P
S
W/HAND
R
A
I
L
A
T
C
E
N
T
E
R
C/C
C/C
RAMP
6' CLF
6' CLF
1X7", 5X4"
,
4
X
3
"
UNKNOW
N
DECIDUO
U
S
6' CLF 6' WDF 6' WDF
6' WDF
1X7" AND
1
4
X
3
"
UNKNOWN
DECIDUO
U
S
1X7" AND 1
4
X
3
"
UNKNOWN
DECIDUOU
S
RAMP
C/C
C/C
6' CLF
6' CLF
6' CLF
UTILITY
LOCATE
PAINTED
STUB MA
R
K
C/G
C/G
C/G
1X9",2X7",1
X
4
"
UNKNOW
N
DECIDUOUS
"STOP"
C/G C/G C/G C/G
C/G
QWEST TEL
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PER AFN 2
0
0
3
0
3
2
7
0
0
0
9
2
5
PRIVATE
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PER EAS
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AFN 200
2
0
6
1
2
0
0
0
6
2
2
PSE ELEC
T
R
I
C
A
LEASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
PSE ELEC
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
SE
N
E
C
A
A
V
E
S
W
SW 12TH ST16+00 17+00 18+00 19+00 20+00 21+00
PI: 15+46.08
10
9
+
0
0
11
0
+
0
0
PI: 109
+
6
6
.
4
1
N77° 27' 51"E
546.08'
N77° 27' 44"E
988.66'
N1
°
2
3
'
1
0
"
E
27
8
.
3
5
'
N1
°
2
7
'
1
4
"
E
30
0
.
8
4
'
SW 12TH ST STA: 15+46.08 =
SENECA AVE SW STA: 109+66.41
LI
N
D
A
V
E
S
W
L15
GP
GP GP GP GP GP
N77°27'44"E 988.66'(C)
C/G
C/G
E/C
C/C
C/C
RAMP
RAMP C/C
C/C
C/C
C/C
RAMP 12"MAPLE
12"MAPLE
14"MAPLE
8"UNKNOWN
DECIDUO
U
S
C/C31.3'DRIVEWAY C/GC/GC/G
C/G
E/C
E/C
E/C
E/CE/C
E/C
C/G
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PAR
T
O
F
S
U
R
V
E
Y
(TAX PAR
C
E
L
N
O
.
3
3
4
0
4
0
4
1
5
0
)
23.9'DRIVEWAY
20.6'
DRIVEWAY 24.2'
DRIVEWAYC/GC/G
E/CE/C
GATE
C/C
C/C
GATE
0.5'
0.4'
4.9'8.0'
6' CLF
7' CLF
0.2'0.3'0.2'
7' CLF
6' CLF
6' CLF
6' CLF
6' CLF A
N
G
L
E
P
O
I
N
T
BEARS S
8
4
°
1
1
'
E
,
0
.
6
'
FROM CA
L
C
U
L
A
T
E
D
LOT COR
N
E
R
6'/7' CLF
A
N
G
L
E
P
O
I
N
T
BEARS N
8
9
°
5
0
'
E
,
0
.
6
'
FROM CA
L
C
U
L
A
T
E
D
LOT COR
N
E
R
14.4'
"STOP"
STOP BA
R
STOP BA
R
C/G
30.0'DRIVEWA
Y
E/C
"STOP"
STEEL PO
S
T
F
O
R
AERIAL
WALKER'
S
R
E
N
T
O
N
SUBARU
P
A
R
T
S
A
N
D
SERVICE
C
E
N
T
E
R
S
I
G
N
UNKNOW
N
U
S
E
CLEANOUT
RIM=21.96'
17"MAPLE 237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L16GPGP
P
C/G
C/G
C/C C/C
14.9'
DRIVEWAY
GATE
E/CE/C
15"UNKNOWNDECIDUOU
S
13"
UNKNOW
N
DECIDUOU
S
15"UNKNOW
N
DECIDUO
U
S
CONC. STE
P
S
W/HAND
R
A
I
L
A
T
C
E
N
T
E
R
C/C
C/C
RAMP
6' CLF
6' CLF
1X7", 5X4"
,
4
X
3
"
UNKNOW
N
DECIDUO
U
S
6' CLF 6' WDF 6' WDF
6' WDF 1X7" AND 1
4
X
3
"
UNKNOWN
DECIDUO
U
S
1X7" AND 1
4
X
3
"
UNKNOWN
DECIDUO
U
S
RAMP
C/C
C/C
6' CLF
6' CLF
6' CLF
UTILITY
LOCATE
PAINTED
STUB MA
R
K
C/G
C/G
C/G
1X9",2X7",
1
X
4
"
UNKNOW
N
DECIDUO
U
S
"STOP"
C/G C/G C/G C/G
C/G
QWEST T
E
L
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PER AFN
2
0
0
3
0
3
2
7
0
0
0
9
2
5
PRIVATE
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PER EAS
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AFN 200
2
0
6
1
2
0
0
0
6
2
2
PSE ELEC
T
R
I
C
A
LEASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
PSE ELE
C
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
SE
N
E
C
A
A
V
E
S
W
SW 12TH ST16+00 17+00 18+00 19+00 20+00 21+00
PI: 15+46.08
10
9
+
0
0
11
0
+
0
0
PI: 109
+
6
6
.
4
1
N77° 27' 51"E
546.08'
N77° 27' 44"E
988.66'
N1
°
2
3
'
1
0
"
E
27
8
.
3
5
'
N1
°
2
7
'
1
4
"
E
30
0
.
8
4
'
SW 12TH ST STA: 15+46.08 =
SENECA AVE SW STA: 109+66.41
LI
N
D
A
V
E
S
W
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
DEMOLITION NOTES
44
SW 12TH ST FRONTAGE
IMPROVEMENTS
CR1.2Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
S
W
1
2
T
H
.
d
w
g
1.CONTRACTOR IS TO VERIFY LOCATION AND DEPTH OF ALL UTILITIES SHOWN.
THE CONTRACTOR IS TO PROTECT UNDERGROUND UTILITIES DURING
CONSTRUCTION.
2.CONTRACTOR TO PROTECT EXISTING STORM SYSTEM LOCATED IN FRONTAGE
ALONG EAST VALLEY ROAD.
3.CONTRACTOR TO PROTECT EXISTING CURB AND GUTTER LOCATED IN
FRONTAGE ALONG SW 12TH ST.
1.ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN
THE RENTON STANDARD PLANS AND SPECIFICATIONS.
2.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. THE
CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION AND DEPTH OF ALL
UTILITIES SHOWN.
3.CONTRACTOR IS TO RAISE ALL REMAINING STRUCTURE LIDS TO BE FLUSH
WITH FINISHED GRADE. REFER TO PLAN FOR REMAINING STRUCTURES.
4.ALL IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY SHALL CONFORM TO
CITY OF RENTON CONSTRUCTION STANDARDS.
DEMOLITION PLAN
IMPROVEMENTS PLAN
FRONTAGE IMPROVEMENT NOTES
PROTECT EXISTING
CATCH BASIN
REMOVE EXISTING DRIVEWAY
AND ASPHALT WEDGE CURB
RELOCATE METER OUTSIDE OF
CONCRETE SIDEWALK AS NECESSARY
SEE SHEET CR1.4 FOR WATER MAIN IMPROVEMENTS
SAWCUT ALONG EXISTING GUTTER SAWCUT ALONG EXISTING GUTTER
REMOVE EXISTING DRIVEWAY, CURB AND GUTTER
PROTECT EXISTING POWER POLE
INSTALL DETECTABLE
WARNING SURFACE ON
EXISTING RAMPS
TYPE C1 CONCRETE DRIVEWAY,
SEE SHEET CR1.3 FOR
GRADING ENLARGEMENT
3
CR1.5
TYPE C1 CONCRETE DRIVEWAY,
SEE SHEET CR1.3 FOR
GRADING ENLARGEMENT
3
CR1.5
TYPE C1 CONCRETE DRIVEWAY,
SEE SHEET CR1.3 FOR
GRADING ENLARGEMENT
3
CR1.5
INSTALL DETECTABLE
WARNING SURFACE ON
EXISTING RAMPS
SEE SHEET CR1.4 FOR WATER MAIN IMPROVEMENTS
4
CR1.5
4
CR1.5
R-438833
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
GP GP
14
"
MA
P
L
E
26
.
9
'
DR
I
V
E
W
A
Y
C/
G
6'
C
L
F
6'
C
L
F
GA
T
E
6'
C
L
F
FE
N
C
E
T
R
A
N
S
I
T
I
O
N
6'
C
L
F
/
6
'
S
T
E
E
L
75.20'
SENECA AVE SW
S
W
1
3
T
H
S
T
106+50 107+00
TC:20.42
FL: 20.42
TC:20.11
FL: 20.11
TC:20.50
FL: 20.00
STA:106+82.85, 17.93' RT STA:107+06.96, 17.96' RT
STA:107+12.96, 17.99' RT
MATCH EXISTING
1.
4
7
%
1.00%
1.00%
1.
5
0
%
1.33%
1.32%
1.
5
0
%
6.58%
2.
0
2
%
6.14%
10.00'
2.73%
0.18%
1.
9
9
%
5.06'
6.00'24.09'6.01'
5.00'
FG: 20.44
FG: 20.61 FG: 20.51 FG: 20.19
EG: 20.59
FG: 21.20 FG: 20.92
FG: 21.55
FG: 21.71
BEGIN VERTICAL CURB
BACK OF CURB INSTALLED
MINIMUM OF 2.0' FROM
NEW POLE
STA:106+69.25, 3.24' LT END VERTICAL CURB
BACK OF CURB INSTALLED
MINIMUM OF 2.0' FROM NEW POLE
STA:106+82.86, 17.93' RT
FG: 20.55
FG: 20.53
GP
GP
GP
GP GP
S01°23'10"W 278.35'(M)
C/
G
RA
M
P
C/
C
C/
C
C/
C
C/
C
RA
M
P
12
"
MA
P
L
E
C/
G
E/
C
"S
T
O
P
"
ST
O
P
B
A
R
C/
G
C/
G
C/
G
30
.
0
'
DR
I
V
E
W
A
Y
E/
C
E/
C
E/
C
CO
N
C
.
GA
T
E
12
"MA
P
L
E
"S
T
O
P
"
L10
PS
E
E
L
E
C
T
R
I
C
A
L
EA
S
E
M
E
N
T
P
E
R
A
F
N
20
0
3
0
1
2
8
0
0
2
5
9
1
1
5
+
5
0
108+50 109+00 109+50 110+00
SENECA AVE SW STA: 109+66.41 =
SW 12TH ST STA: 15+46.08
TC:20.62
FL: 20.12
TC:20.12
FL: 20.12
TC:20.09
FL: 20.09
TC:20.60
FL: 20.10
STA:108+78.49, 17.91' RT
MATCH EXISTING
STA:108+84.49, 17.98' RT
STA:109+09.77, 18.04' RT
STA:109+17.77, 17.98' RT
MATCH EXISTING
SENECA AVE SW
S
W
1
2
T
H
S
T
1.
3
8
%
7.91%
1.
5
0
%
8.01%
0.15%
1.
5
0
%
0.15%
6.57%
1.
7
5
%
6.41%
5.05'
6.00'25.27'8.00'
5.00'
EG: 20.68
FG: 20.21 FG: 20.17 EG: 20.70
FG: 21.02
FG: 21.59FG: 21.52
FG: 20.95
5.91'
4.18'
5.51'
5.63'
4.02'
5.86'
EG: 20.24
EG: 20.64
EG: 20.30
EG: 20.74
EG: 20.78
EG: 20.74
EG: 20.99
EG: 20.99
EG: 20.48
EG: 20.82
EG: 20.48
EG: 20.94
C/G
14"
MAPLE
8"UNKNOW
N
DECIDU
O
U
S
C/C
31.3'
DRIVEWAY
C/G
E/C
E/C
E/C 6' CLF
0.6'
0.5'
6' CLF A
N
G
L
E
P
O
I
N
T
BEARS S
8
4
°
1
1
'
E
,
0
.
6
'
FROM CA
L
C
U
L
A
T
E
D
LOT COR
N
E
R
117.44'
C/G
SW 12TH ST
1.
8
0
%
7.94%
1.
5
0
%
8.18%1.11%1.
5
0
%
1.12%
7.41%2.
0
0
%
6.99%
4.94'
6.00'24.99'6.00'
4.93'
FG: 21.55 FG: 21.06
FG: 21.34 FG: 21.78
TC:21.45
FL: 20.95
STA:16+48.65, 18.04' RT
MATCH EXISTING
STA:16+54.64, 18.02' RT
STA:16+79.64, 18.10' RT
STA:16+85.64, 18.11' RT
MATCH EXISTING
TC:20.97
FL: 20.97
TC:21.25
FL: 21.25
TC:21.83
FL: 21.33
FG: 21.60 FG: 21.79
L15 GP GP GP GP
N77°27'44"E 988.66'(C)
C/G 23.9'
DRIVEWAY
20.6'
DRIVEWAY 24.2'
DRIVEWAY
C/GC/G
E/CE/C
GATE
C/C
0.5'
7' CLF
0.2'0.3'0.2'
7' CLF
6' CLF
6'/7' CLF
A
N
G
L
E
P
O
I
N
T
BEARS N
8
9
°
5
0
'
E
,
0
.
6
'
FROM C
A
L
C
U
L
A
T
E
D
LOT COR
N
E
R
14.4'
L16
C/C
GATE
6' CLF
C/G C/G
SW 12TH ST
STA:17+91.58, 18.00' RT STA:18+13.06, 18.02' RT STA:18+54.31, 18.05' RT
STA:18+60.31, 18.06' RT
STA:18+80.91, 18.06' RT
STA:18+86.91, 18.06' RT
STA:17+85.58, 18.04' RT
MATCH EXISTING
STA:18+19.06, 18.01' RT
MATCH EXISTING
STA:18+38.33, 18.05' RT
MATCH EXISTING
STA:19+02.48, 18.06' RT
MATCH EXISTING
TC:22.02
FL: 21.52
TC:21.56
FL: 21.56
TC:21.42
FL: 21.42
TC:21.88
FL: 21.38
TC:21.82
FL: 21.32
TC:21.76
FL: 21.26
TC:21.35
FL: 21.35
TC:21.31
FL: 21.31
TC:21.79
FL: 21.29
TC:21.63
FL: 21.13
1.
3
3
%
7.27%
1.
5
0
%
7.14%0.64%1.
5
0
%
0.64%
7.15
%1.
7
5
%
6.81%
4.99'
6.00'21.48'6.00'
7.34'1.
8
0
%
0.70%
1.
5
0
%
0.46%6.77%1.
5
0
%
6.77%
0.18%1.
5
0
%
0.18%
7.87%1.
5
0
%
7.87%
1.73%1.
6
7
%
1.78%
FG: 21.77 FG: 21.84 FG: 21.43 FG: 21.40 FG: 21.87
FG: 21.60
FG: 21.88
FG: 21.97
FG: 21.51
FG: 21.64
FG: 22.07
5.00'5.00'
FG: 22.10
FG: 22.10 FG: 21.78 FG: 21.69
15.98'6.00'20.60'6.00'15.57'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
45
FRONTAGE DRIVEWAYS
ENLARGEMENTS
CR1.3Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
F
i
n
a
l
De
s
i
g
n
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
I
N
T
X
.
d
w
g
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
R-438834
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
L15
GP
GP GP GP GP GP
N77°27'44"E 988.66'(C)
C/G
C/G
C/G
E/C
E/C
C/C
C/C
RAMP
RAMP C/C
C/C
C/C
C/C
RAMP
12"MAPLE
12"MAPLE
14"MAPLE
8"UNKNOWNDECIDUOU
S
C/C31.3'
DRIVEWAY C/GC/GC/G
C/G
E/C
E/C
E/C
E/CE/C
E/C
C/G
6' CLF
6' CLF
6' CLF
0.6'
0.5'
NOT PAR
T
O
F
S
U
R
V
E
Y
(TAX PA
R
C
E
L
N
O
.
3
3
4
0
4
0
4
1
5
0
)
23.9'
DRIVEWAY
20.6'DRIVEWAY 24.2'DRIVEWAYC/GC/G
E/CE/C
GATE
C/C
C/C
GATE
0.5'
0.4'
4.9'
8.0'
6' CLF
7' CLF
0.2'0.3'0.2'
7' CLF
6' CLF
6' CLF
6' CLF
6' CLF AN
G
L
E
P
O
I
N
T
BEARS S
8
4
°
1
1
'
E
,
0
.
6
'
FROM CA
L
C
U
L
A
T
E
D
LOT COR
N
E
R
6'/7' CLF
A
N
G
L
E
P
O
I
N
T
BEARS N
8
9
°
5
0
'
E
,
0
.
6
'
FROM CA
L
C
U
L
A
T
E
D
LOT COR
N
E
R
14.4'
"STOP"
STOP BA
R
STOP BA
R
C/G
30.0'DRIVEWAY
E/C
"STOP"
STEEL P
O
S
T
F
O
R
AERIAL
WALKER'
S
R
E
N
T
O
N
SUBARU
P
A
R
T
S
A
N
D
SERVICE
C
E
N
T
E
R
S
I
G
N
UNKNOWN
U
S
E
CLEANOUT
RIM=21.9
6
'
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.
2
0
'
IE=19.10'
1
2
"
P
V
C
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=20.7
0
'IE=17.92'
1
2
"
P
V
C
N
E
IE=18.01
'
1
2
"
P
V
C
S
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=20.
3
9
'
IE=17.67'
1
2
"
P
V
C
E
IE=17.68
'
1
2
"
P
V
C
S
W
IE=17.65'
1
2
"
P
V
C
N
W
IE=17.45'
1
2
"
P
V
C
N
IE=17.48'
1
2
"
P
V
C
S
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
DID NOT
O
P
E
N
RIM=22.
0
4
'
12"
MAPLE
17"MAPLE
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=21.
2
0
'IE=18.13'
1
2
"
P
V
C
N
E
IE=18.41'
1
2
"
P
V
C
S
E
IE=18.17'
1
2
"
P
V
C
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.
8
0
'
IE=19.04'
8
"
S
W
IE=18.97'
1
2
"
P
V
C
N
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=21.1
5
'
IE=18.22'
1
2
"
P
V
C
N
E
IE=18.27
'
1
2
"
P
V
C
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=21.
0
7
'IE=18.55'
8
"
P
V
C
N
E
IE=18.42'
1
2
"
P
V
C
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=20.7
6
'
FULL OF
D
I
R
T
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=20.7
0
'
IE=17.88'
1
2
"
P
V
C
N
E
IE=17.81'
1
2
"
P
V
C
N
W
237.36'
117.44'
S0
1
°
2
2
'
4
2
"
W
N0
1
°
2
2
'
4
3
"
E
11
6
.
3
8
'
L16GPGP
P
C/G
C/G
C/C C/C
14.9'DRIVEWAY
GATE
E/CE/C
15"UNKNOW
N
DECIDUO
U
S
13"
UNKNOWN
DECIDUOUS
15"UNKNOWNDECIDUOU
S
CONC. STE
P
S
W/HANDR
A
I
L
A
T
C
E
N
T
E
R
C/C
C/C
RAMP
6' CLF
6' CLF
1X7", 5X4",
4
X
3
"
UNKNOWN
DECIDUO
U
S
6' CLF 6' WDF 6' WDF
6' WDF 1X7" AND 14
X
3
"
UNKNOW
N
DECIDUOU
S
1X7" AND 1
4
X
3
"
UNKNOW
N
DECIDUOU
S
RAMP
C/C
C/C
6' CLF
6' CLF
6' CLF
STORMD
R
A
I
N
C
U
L
V
E
R
T
E
N
D
IE=19.03
'
1
6
"
C
M
P
UTILITY
LOCATE
PAINTE
D
STUB M
A
R
K
C/G
C/G
C/G
1X9",2X7",1X
4
"
UNKNOWN
DECIDUO
U
S
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
2.1' X 1.7'
RIM=23.5
6
'IE=20.43
'
6
"
D
I
N
E
IE=20.5
3
'
6
"
D
I
S
W
IE=22.81'
4
"
P
V
C
N
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
W
/
S
O
L
I
D
L
I
D
RIM=23.
3
4
'IE=20.10'
6
"
D
I
S
E
IE=20.25'
6
"
D
I
S
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.
0
8
'
IE=19.65'
6
"
P
V
C
N
E
IE=19.58
'
8
"
C
M
P
S
E
IE=19.74'
6
"
D
I
N
W
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE IRIM=21.
9
1
'IE=19.84'
8
"
D
I
S
E
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE II
W
/
G
R
A
T
E
D
L
I
D
RIM=21.
8
8
'
IE=19.46'
1
2
"
D
I
N
E
IE=19.39'
1
6
"
C
M
P
S
E
IE=19.74'
8
"
S
W
IE=19.07'
8
"
D
I
N
W
FULL OF
W
A
T
E
R
TOP WA
T
E
R
=
2
0
.
2
5
'
IE=19.83
'
1
2
"
D
I
S
W
"STOP"
STORMD
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=20.
8
7
'
IE=19.58'
1
2
"
D
I
N
E
C/G C/G C/G C/G
C/G
QWEST T
E
L
E
C
O
M
M
U
N
I
C
A
T
I
O
N
S
E
A
S
E
M
E
N
T
PER AFN 2
0
0
3
0
3
2
7
0
0
0
9
2
5
PRIVATE
I
N
G
R
E
S
S
/
E
G
R
E
S
S
E
A
S
E
M
E
N
T
PER EAS
E
M
E
N
T
A
G
R
E
E
M
E
N
T
W
I
T
H
R
I
G
H
T
S
A
N
D
R
E
S
P
O
N
S
I
B
I
L
I
T
I
E
S
AFN 2002
0
6
1
2
0
0
0
6
2
2
PSE ELEC
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
PSE ELE
C
T
R
I
C
A
L
EASEME
N
T
P
E
R
A
F
N
2003012
8
0
0
2
5
9
1
STORM
D
R
A
I
N
C
A
T
C
H
B
A
S
I
N
TYPE I
RIM=21.
2
0
'
IE=18.88'
1
2
"
P
V
C
N
E
IE=18.77'
6
"
P
V
C
S
E
IE=18.75'
1
2
"
P
V
C
S
SE
N
E
C
A
A
V
E
S
W
SW 12TH ST
10
9
+
0
0
11
0
+
0
0
PI: 109
+
6
6
.
4
1
16+00 17+00 18+00 19+00 20+00 21+00
PI: 15+46.08
SW 12TH ST STA: 15+46.08 =
SENECA AVE SW STA: 109+66.41
N77° 27' 51"E
546.08'
N77° 27' 44"E
988.66'
N1
°
2
3
'
1
0
"
E
27
8
.
3
5
'
N1° 27' 14"E
300.84'
STA:19+77.08, 10.93' LT
CONNECT TO EXSTING 12" TEE
CONTRACTOR TO COORDINATE WITH CITY OF
RENTON FOR REMOVAL OF EXISTING
CAP/PLUG AND OTHER ASSOCIATED FITTINGS.
SEE COR STD PLAN 300.4 FOR CONNECTION
DETAIL
STA:15+56.38, 6.00' LT
CUT IN TEE TO EX 10" WATER
MAIN PER COR STD PLAN 300.2
BY CITY FORCES
(1) 10" TEE (FL)
(1) 10" ADAPTER (FL x MJ)
(1) 10" SLEEVE (MJ)
(1) 10" GATE VALVE (FL x MJ)
(1) 10" GATE VALVE (FL x FL)
(1) 10" x 12" REDUCER (FL x MJ)
273 LF 12" DI CL52
WATER MAIN (PUBLIC)
EXISTING 6" WATER MAIN TO
BE ABANDONED IN PLACE
STA:18+29.70, 6.00' LT
1-12"x6" TEE (FLXFL)
1-6" GATE VALVE (FLxMJ)
1-12" GATE VALVE (FLxMJ)
1-12" ADAPTER (FLxMJ)
1-CONC. THRUST BLOCK
STA:18+29.70, 25.64' LT
REPLACE EXISTING HYDRANT
WITH NE HYDRANT PER COR STD
PLAN 310.1, 310.2, AND 310.3
128 LF 12" DI CL52
WATER MAIN (PUBLIC)
STA:19+57.66, 6.00' LT
1- 45° 12" BEND (MJ)
STA:19+62.09, 10.62' LT
1- 45° 12" BEND (MJ)
6 LF 12" DI CL52
WATER MAIN (PUBLIC)
15 LF 12" DI CL52
WATER MAIN (PUBLIC)
Profile View of SW 12TH ST3
SW 12TH ST
14
16
18
20
22
24
26
28
30
14
16
18
20
22
24
26
28
30
15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00
EXISTING GRADE AT ROAD CENTERLINE
EXISTING GRADE ELEVATION AT ROAD CENTERLINE
273 LF 12" DI CL52
WATER MAIN (PUBLIC)
STA: 15+60.46
CUT IN TEE TO EX 10" WATER
MAIN PER COR STD PLAN 300.2
BY CITY FORCES
(1) 10" TEE (FL)
(1) 10" ADAPTER (FL x MJ)
(1) 10" SLEEVE (MJ)
(1) 10" GATE VALVE (FL x MJ)
(1) 10" GATE VALVE (FL x FL)
(1) 10" x 12" REDUCER (FL x MJ)
STA: 19+77.08
CONNECT TO EXSTING 12" TEE
CONTRACTOR TO COORDINATE WITH CITY OF
RENTON FOR REMOVAL OF EXISTING
CAP/PLUG AND OTHER ASSOCIATED FITTINGS.
SEE COR STD PLAN 300.4 FOR CONNECTION
DETAIL
STA: 18+29.74
1-12"x6" TEE (FLXFL)
1-6" GATE VALVE (FLxMJ)
1-CONC. THRUST BLOCK
RECONNECT HYDRANT TO NEW TEE.
128 LF 12" DI CL52
WATER MAIN (PUBLIC)
12" STORM
CROSSING
15 LF 12" DI CL52
WATER MAIN (PUBLIC)
6 LF 12" DI CL52
WATER MAIN (PUBLIC)
DEFLECT WATER PIPE 2.5°
STA: 15+76.52
MANUFACTURERS RECOMENDATION: 5°
MAXIMUM DEFLECTION ALLOWED: 2.5°
DEFLECT WATER PIPE 2.0°
STA: 15+84.52
MANUFACTURERS RECOMENDATION: 5°
MAXIMUM DEFLECTION ALLOWED: 2.5°
DEFLECT WATER PIPE 0.7°
STA: 19+48.67
MANUFACTURERS RECOMENDATION: 5°
MAXIMUM DEFLECTION ALLOWED: 2.5°
STA: 19+62.09
1- 45° 12" BEND (MJ)
STA: 19+57.66
1- 45° 12" BEND (MJ)
EX POWER CONDUIT
BOT PIPE:17.01
TOP WATER: 15.5
EX GAS LINE
BOT PIPE: 18.31
TOP WATER: 16.36
EX 12" STORM
BOT PIPE:18.51
TOP WATER: 16.17
EX GAS LINE
BOT PIPE: 18.25
TOP WATER: 16.14
EX POWER CONDUIT
BOT PIPE: 18.26
TOP WATER: 16.10
EX POWER CONDUIT
BOT PIPE: 18.35
TOP WATER: 16.77
EX 8" STORM
BOT PIPE: 19.33
TOP WATER: 17.58
EX GAS LINE
BOT PIPE: 19.31
TOP WATER: 17.79
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
N
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
46
SW 12TH ST PLAN AND PROFILE CR1.4Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
S
W
1
2
T
H
P
&
P
.
d
w
g
KEYNOTES
SW 12TH ST PROFILE
SCALE; H:1" = 20', V:1" = 4'
PAVEMENT PATCH AND
FULL LANE OVERLAY
PER COR STD DTL 110.1
RECONNECT 3/4" WATER
SERVICE TO NEW MAIN
BY CITY FORCES
RECONNECT 3/4" WATER
SERVICE TO NEW MAIN
BY CITY FORCES
RECONNECT 1" IRRIGATION
SERVICE TO NEW MAIN BY
CITY FORCES
1 1 1
1 POWER/COMM LINE CROSSING, CONTRACTOR TO POTHOLE
AND VERIFY DEPTH PRIOR TO CONSTRUCTION.
2 STORM CROSSING, CONTRACTOR TO POTHOLE AND VERIFY
DEPTH PRIOR TO CONSTRUCTION.
3 GAS LINE CROSSING, CONTRACTOR TO POTHOLE AND
VERIFY DEPTH PRIOR TO CONSTRUCTION.
2
2 2
333
EXISTING WATER MAIN,
SEE COR RECORD
DRAWING W-306804
EXISTING WATER MAIN,
SEE COR RECORD
DRAWING W-091702
REMOVE EX 10" GATE VALVE
AND 10"X6" REDUCER.
INSTALL 10" BLIND FLANGE
ON EXISTING CROSS (EAST
SIDE)
POLYPIGGING STATION
PER COR STD PLAN
300.7
4.25'
EXISTING DEAD-MAN BLOCK
REMOVE EX 6" GATE
VALVE/VALVE BOX AND 6"
BLIND FLANGE EX 6" SIDE
OF TEE
WT
R
-
2
7
-
4
3
8
8
W-438807 R-438835
1.ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END
(S) SHALL HAVE A WEDGE-TYPE RETRAINER GLAND EQUAL TO
MEGALUG SERIES 110
2.12-INCH WATER MAIN SHALL HAVE A MINIMUM OF 4-FEET OF COVER
AND A MAXIMUM OF 6-FEET OF COVER.
WATER UTILITY NOTE
4 CONTRACTOR SHALL POTHOLE AND VERIFY EXISTING WATERMAIN ELEVATIONS
PRIOR TO CONSTRUCTION. IF ELEVATIONS DIFFER FROM APPROVED PLANS, THE
ENGINEER OF RECORD AND CITY OF RENTON SHALL BE NOTIFIED IMMEDIATELY
4
4
3
CR1.6
5.92'
REPLACE SIDEWALK AS
NECESSARY FOR
HYDRANT INSTALLATION
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
47
CITY OF RENTON FRONTAGE
IMPROVEMENT DETAILS
CR1.5Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
D
E
T
L
.
d
w
g
`
RAMP
3/
1
6
"
1 5/8"2 3/8"
5/8"
7/16"
7/8"1 7/16"
3/4"
1 1/2"
C
D
A
B
A B
A
B
C
D
MIN MAX
DETECTABLE WARNING PATTERN AREA
SHALL BE YELLOW, IN COMPLIANCE WITH
WSDOT STANDARD SPEC. 8-14.3(3)
1 CEMENT CONCRETE SIDEWALK 2 CURB AND GUTTER REPLACEMENT
3
CEMENT CONCRETE DRIVEWAY
ENTRANCE NOTES AND DETAILS
4 NOT TO SCALE
TRUNCATED DOMES
R-438836
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
48
CITY OF RENTON FRONTAGE
IMPROVEMENT DETAILS
CR1.6Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
D
E
T
L
.
d
w
g
1 CEMENT CONCRETE DRIVEWAY ENTRANCE 2 TRANSVERSE PATCH FOR FLEXIBLE PAVING
3
TYPICAL LONGITUDINAL PATCH
FOR FLEXIBLE PAVEMENT
R-438837
05/15/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
49
CITY OF RENTON FRONTAGE
IMPROVEMENT DETAILS
CR1.7Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
D
E
T
L
.
d
w
g
1.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS
STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS
AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS. A PRE-CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF
CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS
PRIOR TO CONSTRUCTION.
2.ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR
SHALL CALL 1- 800-424- 5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION.
3.ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND
CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY
MATERIALS ON- SITE.
4.ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C
104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250
AS PER ANSI/ AWWA C110/ A21. 10- 82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8 -MIL BLACK, TUBE -TYPE,
POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS.
5.MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10 -INCH OR
LESS AND 48 INCHES FOR PIPE DIAMETER OF 12 -INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60
INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS
OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE
MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE- HALF OF PIPE MANUFACTURER' S SPECIFICATION FOR SIZE OF PIPE
USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED
PROCTOR TEST METHOD ( MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT
MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD.
6.CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY
OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS,
FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS ( OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN
ADDITION TO CONCRETE BLOCKING.
7.ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED,
DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE
SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS,
CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE.
NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL
THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING.
8.NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING
PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING
THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED,
FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR.
9.THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10
WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE
EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS
REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE
SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER
SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE
RESTORATION.
CITY OF RENTON WATER PLAN GENERAL NOTES STD. PLAN 300.0 (MARCH 2010)
1 CONNECTION TO WATER MAIN
2
CONCRETE BLOCKING FOR
HORIZONTAL FITTINGS 3 CONCRETE BLOCKING FOR VERTICAL FITTINGS
W-438808
WT
R
-
2
7
-
4
3
8
8
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
50
CITY OF RENTON FRONTAGE
IMPROVEMENT DETAILS
CR1.8Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
D
E
T
L
.
d
w
g
1 CONNECTION TO EXISTING END LINE CAP
2
CONNECTION TO WATER MAIN
CUT-IN TEE AND TWO VALVES 3 FIRE HYDRANT ASSEMBLY
W-438809
WT
R
-
2
7
-
4
3
8
8
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
T A C O M A
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
S E A T T L E
S P O K A N E T R I - C I T I E S
WALKER SUBARU SERVICE CENTER
PERMIT SET
AHBL JOB #2240819.10
55
Know what's below.
before you dig.Call
R
C2
6
0
0
0
6
3
8
LU
A
2
5
-
0
0
0
1
7
1
PR
2
5
-
0
0
0
0
3
1
TE
D
-
4
0
-
4
3
8
8
51
CITY OF RENTON FRONTAGE
IMPROVEMENT DETAILS
CR1.9Q:
\
2
0
2
4
\
2
2
4
0
8
1
9
\
1
0
_
C
I
V
\
C
A
D
\
_
R
O
W
P
l
a
n
Se
t
\
2
2
4
0
8
1
9
-
S
H
-
F
R
O
N
T
A
G
E
-
D
E
T
L
.
d
w
g
1 POLYPIGGING NEW WATER MAINS 2 FIRE HYDRANT ASSEMBLY SHEAR BLOCK 3 FIRE HYDRANT ASSEMBLY PAVEMENT MARKER
W-438810
WT
R
-
2
7
-
4
3
8
8
05/15/2026
WATER UTILITY
JValdez 06/03/2026
DEVELOPMENT ENGINEERING
msippo 06/05/2026
5552
R-438839
DEVELOPMENT ENGINEERING
msippo 06/05/2026
5553
R-438840
DEVELOPMENT ENGINEERING
msippo 06/05/2026
5554
R-438841
DEVELOPMENT ENGINEERING
msippo 06/05/2026
5555
R-438842
DEVELOPMENT ENGINEERING
msippo 06/05/2026