HomeMy WebLinkAboutR-438826GD 00 C'7 I 1 W I- ca 3 LI -j p W Q p U > ry U�- o� �) rn� OC)- o 00 N N t N CV C O 0) 04 ' y dej p Z Know what's below. Call before you dig. 012" RCP MAX. INLET ALTERNATE INLET LOCATION 7'-0" 6'-0" ALTERNATE OUTLET LOCATION 012" RCP MAX. OUTLET 2X 018" TRAFFIC RATED CAST IRON COVERS, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. VARIES ii 11 INLET �\ H I� � I/ \I L C � II ;I OUTLET 13'-0" 12'-0" MAR DIVIDER WALL PLAN VIEW 036" BOLTED & GASKETED ACCESS COVER, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. RIM 4"MIN TO 5' MAX COVER (SEE NOTE 1.13) NOTES: 1. DESIGN LOADINGS: A. AASHTO HS-20-44 (WITH IMPACT) B. DESIGN SOIL COVER: 5'-0" MAXIMUM C. ASSUMED WATER TABLE: BELOW BASE OF PRECAST (ENGINEER -OF -RECORD TO CONFIRM SITE WATER TABLE ELEVATION) D. LATERAL EARTH PRESSURE: 45 PCF (DRAINED) E. LATERAL LIVE LOAD SURCHARGE: 80 PSF (APPLIED TO 8'-0" BELOW GRADE) F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 28-DAY MINIMUM COMPRESSIVE STRENGTH: 5,000 PSI MINIMUM. 3. REINFORCING: REBAR, ASTM A615/A706, GRADE 60 4. CEMENT: ASTM C150 5. REQUIRED ALLOWABLE SOIL BEARING CAPACITY: 2,500 PSF 6. REFERENCE STANDARD: A. ASTM C890 B. ASTM C913 C. AC1318-14 7. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. ENGINEER -OF -RECORD SHALL VERIFY FY THAT NOTED PARAMETERS MEET OR EXCEED PROJECT REQUIREMENTS. IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEER/AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW. 8. INLET AND OUTLET HOLES WILL BE FACTORY CORED/CAST PER PLANS AND CUSTOMER REQUIREMENTS. INLET AND OUTLET LOCATIONS CAN BE MIRRORED. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS, AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. SECTION HEIGHTS, SLABIWALL THICKNESSES, AND KEYWAYS ARE SUBJECT TO CHANGE AS REQUIRED FOR SITE REQUIREMENTS AND/OR DUE TO PRODUCT AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS. 12. MAXIMUM PICK WEIGHTS": A. TOP: XX,XXX LBS B. BASE: XX,XXX LBS" (" COMBINED WEIGHT OF BASE INCLUDES BYPASS WEIR, DIVIDER WALL, ROCK & MEDIA) 13. INTERNALS SHALL CONSIST OF UNDERDRAIN PIPE, ROCK, STORM MIXTM MEDIA, MULCH, DIVIDER WALL, BYPASS WEIR AND OPTIONAL DRAIN DOWN. INLET WINDOW 6-1-1/4" MIN ENERGY DISSIPATION �I III 13'-10" MAX I I + I STONE IH III I� _ _ 1 2„ E 1 III IIIX. MULCH 4-0 III — — — 3'-10" x DIVIDER WALL INLET 2'-8" 2 -2„ [26 ] DROP BYPASS WEIR III StormMix6"^ MEDIA RECOMMENDED, 6" MIN. III III II I -' 6" DRAIN ROCK ----��� --- 6" OUTLET UNDERDRAIN PIPE OPTIONAL DRAIN 2'-10" 4" 2'-10" 1'-6" 6" 10'-0" DOWN DEVICE Ta LEFT END VIEW ELEVATION VIEW Bioretention/ Biof Itration 6X12 BIOPOD BIOFILTER NOT TO SCALE T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 00 M Cfl C) O QD AN U FEBH Lk N Q J L0 N L.L R-438826