Loading...
HomeMy WebLinkAboutS-43880500 00 C'M CV ri1 L B., t NOT TO SCALE MAN14OLE FRAME AND COVER SEE STD PLAN 40 ADJUSTMENT RINGS AND MORTAR JOINTS SEE NOTE 3 FIRST s,rET' SHALL BE A MAXIMUM OF 18" BELOW THE COVER CONE (ECCENTRIC.) STEPS — POLYPROPYLENE STEPS SHALL BE INCLUDED RUBBER DASXETED JOINTS SEE NOTE 5 IF REQUIRED, LADDER —POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX PIPE SIZE — 'E' SHELF AND CHANNEL SHALL BE 3000 PSI CONCRETE PRECAST BASE SECTION OR OAST IN SHELF COMPACTED SUBGRADE WITH 6" CRUSHED RACK OR ADDI:TIQNAL VATERIAL SUITABLE TO SUPPORT STRUCTURE .A, ,(3. ,c, ID, E' 48" MIS 48" 6" MIN, 5"MIN 24" MIN_ 21" I D 54" MIA 54'' 8" MIN b 5" MIN 24" MIN 24" 1 D 60" MH B05F 8„ MIN 6" MIN 42" MIN 3O" I D NDTES. 1 STEPS ARE TO BE IN PLACE BEFORE MANfCLE SECTIDN5 ARE INSTALLED 2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478_ 3 ADJUSTMENT OF IHE CASTING TO CRADE SHALL BE PER STO PLAN 106 LIE__Q3£..0F SHIMS IS PR0�11B+TED, 4 SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUD-NG CHANNELING, FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-S1i1EI_DG0AT 10O OR APPROVED EQUAL, COLOR OF COATING SHALL BE WHITE 5 RUBBER CASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443 B CHANNEL VADtH AND HEIGHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PIPE 7 CONNECTIONS TO ihANHOLE SHALI. BE MADE USING KOR—N—SEAL BOOTS OR APPROVED EQUAL B IN UN[UPROVED AREAS. MANHOLES SHALL EXTEND A MINIMIUMI OF 6" AND A MAXIMUM OF 12" ABOVE FNISHE7 GRADE OR MUST HAVE AN AT —GRADE, MINIMUM 2'— DE CONCRETE RING POURED ARCjUND THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING. 9 MANHOLES OVER 20' DEEP SHALL BE A MIN.MLJM OF 60" IN DIAMETER STD. PLAN - 400.1 PUBLIC WORKS DEPARTMENT Martin SANITARY MANHOLE Martin P2Lstuol1261202 ` 4A9C7. D,ATr STANDARD SANITARY MANHOLE. NOT TO SCALE O �� pg WAS0G 131DOM 3 Q f-. TACO MA - S EATTL E SPOKANE - TRI-CITIES �.c�S��clsTsg�° �ti 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIGNAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you dig. 05/15/2026 POLTHOLES 3 PLES EgUALLY SPACED 120' APART ON 23 1/16' (586nn) -4[A R.C. (SEE nETAIL) COVER & FRAME PLAN MEW 25' DJA _ 3/4' 125mml Ci9r�e�7 8 3/4' B 1/2' C2-3/4 ] L64r9r9] TYP COMER SECTION MEW 6 1/2" DIA C673rI�� 25 1/4' DIR NEDPDIA RENE)GASKET 1 t/169 r C27mM] ` [152rIr't7 5/$' -1 23 3/'B' DIA CL OPEN [16MMI 1594mn 1 27 5/16' DIA C694mrn] 314 1/9' DIA �0671~r+7 i NOTES: COVER BOTTOM VIEW (3) BLT SDC, (ALLEN HEAD) 5/8'-11 X 1.5 SS RUBBER WASHER BOLTING DETAIL 1 4' 1 1/ 16' Ifs�ian.J f" 127mml 1/8' —1 1 C3r�n] GASKET GROOVE DETAIL FRAME SECTION VIEW 1. ALL FRAME AND COVER ASSEMBLIES SHALL HAVL A LOCKING LID PER EAST JORDAN IRON WORKS INC. PRODUCT No. 00371572 OR EQUAL. 2, USE FRAME AND COVER FOR SANITARY (SPECIFY „SEWEW '), STD, PLAN - 401.1 ur-Mi PUBLIC WORKS SEWER MANHOLE FRAME AND COVER DEPARTMENT (CITY -OWNED) Martin PastL1����I�c� CITY -OWNED SEWER MANHOLE FRAME AND COVER MAXIMUM DISTANCE BETWEEN SPACERS SHALL BE 6 FEET ON CENTER SEAL BOTH ENDS OF CASING WITH A MANUFACTURED RUBBER SEALING DEVICE, MODEL "W" BY PIPELINE SEAL & INSULATOR OR APPROVED EQUAL PLACE END SPACER MAXIMUM OF 12" FROM END OF CASING (TYP.) V� L— ONE SPACER SHALL BE PLACED ON THE SPIGOT END OF EACH SEGMENT AT THE LINE MARKING THE LIMIT OF INSERTION INTO THE BELL. WHEN THE JOINT IS COMPLETE, THE SPACER SHALL BE IN CONTACT WITH THE BELL OF THE JOINT SO THAT THE SPACER PUSHES THE JOINT AND RELIEVES COMPRESSION WITHIN THE JOINT. STEEL PIPE CASING (MILL PIPE) OR DUCTILE IRON USE 2 STAINLESS STEEL HOSE CLAMPS TO SECURE RUBBER SEAL (1 ON CARRIER PIPE AND 1 ON CASING PIPE) CARRIER PIPE CARRIER PIPE DIAMETER 4" 6" 8" 10" 12" CASING DIAMETER (PUSH —ON JOINT CARRIER PIPE) 10" 12" 14" 16" 20" STEEL CASING THICKNESS 0 25" 0 25" 0 25" 0.25" 0.25" SPACER BAND WIDTH 8" 8" 8" 8" 8" NOTES: 1 CASING SPACERS SHALL BE "CENTER POSITIONING" TYPE CASCADE WATERWORKS MFG OR APPROVED EQUAL 2 MINIMUM RUNNER WIDTH SHALL BE 2 INCHES 3. RUNNER HEIGHT SHALL BE SIZED TO PROVIDE A. MINIMUM 0.75" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES B MINIMUM 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING DURING INSTALLATION 4 STEEL CASING DIAMETERS ARE "OUTSIDE DIAMETER" FOR 16" AND LARGER 5 SPACER BAND WIDTH SHALL BE 12" FOR CARRIER PIPES THAT ARE 36" DIAMETER OR GREATER. 6 FOR CARRIER PIPES EXCEEDING 12" IN DIAMETER, CASING DIAMETER AND THICKNESS SHALL BE DESIGNED BY AN ENGINEER. 7 FOR STEEL CASING, PROVIDE SHOP —APPLIED ANTI —CORROSIVE COATING ON CASING EXTERIOR CONFORMING TO AWWA 210 PRODUCT SHALL BE TNEMEC HI —BUILD TNEME—TAR SERIES 46H-413 OF APPROVED EQUAL MINIMUM COATING THICKNESS SHALL BE 16 MILS DFT. 8. STEEL CASINGS SHALL EXTEND A MINIMUM OF 5 FEET BEYOND ANY WALLS OR STRUCTURES. 9 PRIVATE LATERALS ONLY: CASING SPACERS ARE NOT REQUIRED AS LONG AS THE LATERAL CARRIER PIPE DOES NOT HAVE BELLS THAT WILL FALL WITHIN THE LENGTH OF THE CASING END SEALS ARE REQUIRED FOR ALL LATERAL CASING PIPES. STD. PLAN - 412 UBLIC WORKS CASING PIPE URI DEPARTMENT FOR MAIN LINES & LATERALS Martin PastuCh@?/26/202 vuwi�MsQrM449D DATE SEWER CASING NOT TO SCALE 12: 00 co O O O (fl CV A, u T T C) C) C) N a J CV S-438805