Loading...
HomeMy WebLinkAboutR-436024o DETENTION VAULT AND WATER QUALITY DETAILS co FOR 0 HARMONY RIDGE Lu A PORTION OF SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON `/ui V 0 rr z 00 75 rr 2 Ln N 0 N O \ N 00 N N N iT / 00 N N N / O O 0 N N H Q) a i INLET BAY FRAME AND COVER LOCATION ALTERNATE PIPE LOCATION OUTLET BAY FRAME AND COVER (TYP OF 3) GRADE RINGS/RISERS (TYP OF 3) 2'-7" [787j INLET TRANSFER STORMFILTER HOLE AND I I I 1 1 CARTRIDGE COVER - ------------- --- __---- -- _- y 1 I%_ -�y-- I T�-a�1--1i- --!>r-i I I I I OUTLET (17-0" [3658j) PLAN SEPARATION Fzi WALL I INLET PIPE F y i r =y STEPS I WEIR WALL I 6 d k I I I 11 11 II 11 I L. I I B B B R I II 0 r6 If 11 fll 6 N u 6 II OUTLET PIPE STORMFILTER FLOW KIT CARTRIDGE The StoFrr,wl•66r MBL1sps1Tlsltt StormFilter' 1111 PRODIKT AIAY E .. FD - OR NUKE LF 11.F 1D11-6 RILA FaR5]pi.PA 6g SPET. 6.03)696:8&BOiE. RELATED FOREIGNPA.i�----iJ1FER EAIEMEPENdNG ACTIVATION DISK FILTRATION SAY Z 2 DOcu5gn Envelope ID:E212B987-C626-4330-A5D4-DO55AO107AF9 SEE NOTE 11 (TYPJ i owv�+ 1 A STORMFILTER DESIGN NOTES STORMFILTER TREATMENT CAPACITY VARIES BY CARTRIDGE COUNT AND LOCALLY APPROVED SURFACE AREA SPECIFIC FLOW RATE. PEAK CONVEYANCE CAPACITY TO BE DETERMINED BY ENGINEER OF RECORD • A 6' X 12' [1829 X 36581 PEAK DIVERSION STYLE STORMFILTER IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (14) AND IS AVAILABLE IN A LEFT INLET (AS SHOWN) OR A RIGHT INLET CONFIGURATION ALL PARTS AND INTERNAL ASSEMBLY PROVIDED BY CONTECH UNLESS NOTED OTHERWISE CARTRIDGE SIZE (in. [mmj) 27 [6861 18 [457] LOW DROP RECOMMENDED HYDRAULIC DROP (H) (IL [mm)) 3.05 [9301 2.3 [701] 1.8 [5491 HEIGHT OF WEIR (W) (8. [mmj) 3.00 [9141 2.25 [686] 1.75 [5331 SPECIFIC FLOW RATE (gpm/sf[Uslm1]) 2[1.36) 1.67•[1.13]• 1 1[0.68] 211.361 1,67•[1,13]- 1(0.68] 2[1,36] 1 1.67•(1,131• 1 110'68J CARTRIDGE FLOW RATE (gpm [Usj) 22.511.421 18.79 [1,19] 1 11.25 [0.71] 15 C 9511 12.53 [0.79] 7.5 [0.471 10 [0.63] 8.35 [0.53] 15 [0,321 1,67 gpmisl [1.13 Us/m`) SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB® (PSORB) MEDIA ONLY OD�OOOODOOD DDDDDDHR f100000D K FRAME AND GRATE (24" SQUARE) (NOT TO SCALE) / 1 1 MNI�N / FRAME AND COVER (30" ROUND) (NOT TO SCALE) PERFORMANCE SPECIFICATION FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7" (1781. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. SPECIFIC FLOW RATE SHALL BE 2 GPM/SF [1.36 Us/I [MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPMICF [13.39 Usfmj OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. ALTERNATE DIMENSIONS ARE IN MILLIMETERS [mmj UNLESS NOTED OTHERWISE. 4. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHTS. PLEASE CONTACT YOUR CONTECH REPRESENTATIVE. www.ConteehES com 5. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 6. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 10' [3048] AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. INSTALLATION NOTES A ANY SUB -BASE. BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. F. CONTRACTOR TO REMOVE THE TRANSFER OPENING COVER WHEN THE SYSTEM IS BROUGHT ONLINE. CONTECK SFPD0612 (6' x 12') sow�loNSLtc PEAK DIVERSION STORMFILTER WW W .ContechES.com 9025 Centre Poirne Dr, Sure.0. West Chester, CH 45069 STANDARD DETAIL ..... /❖.❖O. ..o.e ACCESS MANHOLE WITH 24' BOLT LOCKING RING AND COVER PER STD. PLANS 204.40 AND 2(M 50 OUTLET PIPE FLOW w SEE NOTE 11 (TYP I ' I 500' REMOVABLE LOCKING OPTIONAL I PANEL FOR VAULTS GREATER 12* MIN VENTILATION PIPE (TYP). I 5'rt i D ACCESS VAULT I I I THAN 1.250 Sr OF FLOOR AREA SEE NOTE 9 MAY BE USED IN PLAN VIEW LIEU OF TOP ACCESS LL-�J FRAMES, GRATES, AND ROUND SOLD COVERS MARKED'ORAIN" WITH LOCKING BOLTS PER STD PLANS 204.40 AND 204 50 5'al0 GRATE ACCESS DOORS OR 76' MAX. REMOVABLE PANEL 2' MIN. COVER, 4- MIN I- SEE NOTE 10 WALL FLANGE. TYP { 1 -V-Q"*N WID'MIN FLOW kESTPo:: I';j,t FLOW- SURFACE 0 ® LEE r;oTE „ IT, FI ANDHOLDS. STEPT MIN 1 OR LADDER ,re t 7 MIN o FLOW w 01 SEDIMENT STORAGE CAPACITY OF OUTLET PIPE NOT LESS THAN DEVELOPED 100 - YR DESIGN FLOW 7 MIN I SEE NOTE 11 (TYP.) I[� 4' MIN. NOTES: SECTION A 1 THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2. METAL PARTS PREFERRED TO BE STAINLESS STEEL ALUMINIZED STEEL. OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS I.2, OR 5 3. PROVIDE WATER STOP AT ALL CAST4N-PLACE CONSTRUCTION JOINTS. PRECEAST VAULTS SHALL HAVE APPROVED RUBBER GASKET SYSTEM. 4. VAULTS .t0' WI MUST USE REMOVABLE LIDS. S. PREFABRICATED VAULT SECTIONS MAY REQUIRE STRUCTURAL MODIFICATIONS TO SUPPORT 5' X 101 OPENING OVER MAIN VAULT. ALTERNATIVELY, ACCESS CAN BE PROVIDED VIA A SIDE VESTIBULE AS SHOWN. ALL VAULT AREAS MUST BE WITHIN 50' OF AN ACCESS POINT. 7. FOR VAULTS UNDER ROADWAYS THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES ALTERNATIVELY. MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HAND -HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE- S. MNIMUM DIAMETER FOR ALL ACCESS OPENINGS (RISERS) EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES 9. VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED. BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 1D. FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO THE TOP OF THE VAULT EXCEEDS 24 INCHES, AN ACCESS STRUCTURE EQUIVALENT TO A TYPE 2 CATCH BASIN OR TYPE , MANHOLE SHALL BE USED. I I WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL)- WHEN CONNECTING TO AN EXISTING PIPE. USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS 7HE CONNECTING PIPE 12 SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NISI STD. PLAN - 236.00 URI PUBLIC WORKS APPRROVED- DEPARTMENT TYPICAL DETENTION VAULTl0/19/2022 Martin Pastucha VW'E�.xi DATE 2:52 SITE SPECIFIC DATA REQUIREMENTS STRUCTURE ID WATER QUAUTY-FLOW RAT EOI -Sj)- PEAK FLOW RATE Ids [I.JI SF-1 RETURN PERIOD OF PEAK FLOW (yrs) 100 CARTRIDGE FLOW RATE CARTRIDGE SIZE (27. 18. LOW DROP (LD)) '27 MEDIA TYPE (PERLITE, ZPG, PSORB) ZPG NUMBER OF CARTRIDGES REQUIRED 1 9 -INLET BAY RIM ELEVATION FILTER BAY RIM ELEVATION PIPE DATA INVERT MATERIAL DIAMETER INLET PIPE 1 428.55 LCPE 1 12 INLET PIPE 2 429.0511LCPE 12 OUTLET PIPE 42-5.501 LCPE _ 1 12" NOTESISPECIAL REQUIREMENTS: 1 CITY REVIEW COMMENTS DATED 6, 2 CITY REVIEW COMMENTS DATED 9, BENCHMARK DATUM TOP OF 3/8" BRASS PLUG SET IN CONCRETE FOUND BRASS PIN 0.76' BELOW GRADE IN 4X4 MONUMENT AT INTERSECTION OF PUGET DRIVE CONC. MONUMENT IN MONUMENT CASE AT INTX 116TH HORIZONTAL DATUM: VERTICAL DATUM: SE AND SE 19TH ST (NAD 83/11) AVE SE & 157TH ST (JUNE 2022) (NAD 83/11) N0. REVISION NAD '83/' 11 NAVD '88 N: 172240.27, E: 1304612.10 N: 171833.64, E: 1305874.10 RK 9/26/25 TJS SURVEYED: ANG 1 /5/25 TJS DESIGNED: RK DRAWN:RK CHECKED: BJT BY DATE APPR APPROVED: TJS SCALE: 5'x1O' FRAME, GRATE, & SOLID COVER WITH LOCKING BOLTS. PER 2019 DOE RIM=451.30 FG=450.80 � v Q Ln 0 ow LLJ L.� 9 - 0 D D. I D 0 D- D cr LJj (n v - � 3" X 0.090" GAGE SUPPORT a- BRACKET ANCHORED TO 0 CONCRETE WALL. (MAX. 3' VERTICAL SPACING) D N/A v v BOTTOM OF VAULT LID EL=447.80 MAXIMUM DESIGN WATER SURFACE EL=447.30 ORIFICE 0=1-3/16" ORIFICE #3 IE=444.50 (6") ELBOW RESTRICTOR ORIFICE 0=1-3/8" ORIFICE #2 IE=442.50 (6") ELBOW RESTRICTOR SAFETY HANDHOLES, STEPS, OR LADDER. SEE 2019 DOE, 3' MIN. 0 8" SHEAR GATE W/CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER). SEE 2019 DOE. 12" OUTLET PIPE E_ TO CB#13 STATIC WATER SURFACE EL=431.50 IE=431.50 (12") Z v V D D v .D NOTES: RESTRICTOR PLATE WITH D 1. ALL METAL PARTS MUST BE CORROSION ORIFICE #1=3/4" z RESISTANT. STEEL PARTS MUST BE EL=429.50 12" MAX. D STAINLESS STEEL OR ALUMINIZED STEEL. a (TYP.) 2. PROVIDE WATER STOP AT ALL R o D P CAST -IN -PLACE CONSTRUCTION JOINTS. PRECAST VAULTS SHALL HAVE APPROVED BOTTOM OF SUMP EL=427,50 RUBBER GASKET SYSTEM. CONTROL STRUCTURE VAULT SCALE: 1 "=2' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 19W HORIZONTAL: NAD 1983/2011 DATU M CALL BEFORE YOU DIG: 1-800-424-5555 CITY OF RENTON Planning/Building/Public Works Dept. Sy/ Q � o z 100 41 s/UNA L ENG 1/6/26 • J O J v `1 i C � � 7 . _ � 0 t pf i Z i W �N � M � C Q CD fV is 1 c: < a) i C > LO a-+ j f V W V co Y r R-436024 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING 1 N N N O 'O � J N ME t'J N Q J O O MO N r�7 HBray 02/05/202600 W 04 DETENTION VAULT AND WATER QUALITY DETAILS HARMONY RIDGE ICHIJO USA, CO., LTD 1406 140TH PL SE, SUITE 104, BELLEVUE, WA 98007 (D N r N rr0 Z DATE: 1/6/2026 z m FTELDBOOK: 0 O PAGE: DRAWING NO: Q cj SHEET: 24 OF: 66 = W