Loading...
HomeMy WebLinkAboutR-436033ROAD AND DRAINAGE NOTES AND DETAILS FOR 4R, Ao 0 W rW V 0 `r Z 0 75 Er Q 2 I I I I X d) 0 U V) Q C6 00 Cr) N N N 17) S_ N 0) c C 0) 00 N N N m CD CD CD N N (Z H Q) a i1 "BAND--iT BRACKET' OR APPROVED - EOUAL 3 92 Li NOTES I DIMENSIONS FOR THE PARTS LOSE❑ TO ASSEMBLE THE BASE CONNECTIONS ARE iNTEW)ON.ALLY HOT SHOWN. BASE CONNECTIONS ARE PATENTED. MANUFACTURED PRODUCTS THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST CRITERIA. THE RASE CONNECTION DETAILS ARE SHOWN ON TENS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE ASSEMBLED, 7- A 2" (IN) POST 1MTH A 2 1 /4" (IN) PSST ANCHOR OR A 2 1/4- (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE SUBSTITUTED. SEE CONTRACT PLANS. 3, PERFORATED SQUARE SIEEL POST SHALL MEET THE REOUIREMENTS OF WSDOT STANDARD SPECIFICATiDN 9-06, 4, USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED HARDWARE THAT MEETS THE REQUIREMENTS OF WSDO1 STANDARD SPECIFICATIONS 9-06 AND 9-28 MOUNTING ON EXISTING_ METAL POLE OR LUMINAIRE EDGE OF TRAVELED ROADWAY 90 �JO' IT x4" MIN. T OGf OF I OR REF 111CTORtIED SKINS MOUNT FACING Y(degree) OUTWARD IF SIGN IS 07MIN 3C FEET OF ROADWAY GALVANIZED BOLT WITH GALVANIZED WASHERS, ! I SIGN FACE ORIENTATION METAL POST z o u"5 r • . ,7 T P H 51CN POST `1 LOWER SQUAR xa TUBE) � Fino- m% 7HQ c • LINE 'v LOTAER SIGN 5//t6- (IN) CORNER BOLT CJ 005T %JPPDRT OR 3/11"1 iLANGEO SHOULDER BOLT WITH NUT AND WASHERS - 2 REQU4RfD iTYP.) w �• BOLT STOP ' '�IGJr POST a TYPE ST-4 SIGN SUPPORT 1 LOWER SIGN POST SUPPORT -- 2,25' IN_ HEAVY-OLITY ANCHORP GALV., NAM rruYmFRCIAL CONCRETE MOUNTING ON METAL POST SIGN MOUNTINIC ON SINGLE STD. PLAN- 129 + PUBLIC WORKS METAL POST APPROVED: DEPARTMENT (ADOPTED) nATTs DocuSign Envelope IDB16CE03A-ED99-4Fl l-B559-FEB382C92BFB ad 9 1.5" RADIUS (TYP.) A I1 U.J Our-'UE-rN , 1 1 r-. � A U � A C E� SIGN DIMENSIONS SIGN TYPE A B C D E POST MOUNTED STREET NAME SIGN (SPEED LIMIT <40MPH) 8„ VARIES 6" 4.5" 3.5" POST MOUNTED STREET NAME SIGN (SPEED LIMIT >40MPH) 12 VARIES 8" 6" 5" GENERAL NOTES: 1. FONT SHALL BE MUTCD D SERIES, UNLESS AN ALTERNATE MUTCD SERIES IS APPROVED BY THE CITY 2. LETTERS AND NUMERALS SHALL BE CUT FROM 3M ELECTROCUT FILM SERIES 1170 OR APPROVED EQUAL 3. SIGN BLADE SHALL BE FLAT ALUMINUM, TREATED, 0.080 GAUGE 4. SIGN SHEETING SHALL BE 3M HIGH INTENSITY PRISMATIC OR APPROVED EQUAL 5. SIGN MOUNTING HARDWARE SHALL INCLUDE BOLTS, RIVETS SHALL NOT BE ALLOWED 6. FOR SIGN POST DETAILS, SEE CITY OF RENTON STANDARD DETAIL 129, EXCEPT MOUNTING HEIGHT SHALL BE 9'-0" COLORS LEGEND, ARROW HEAD, SEPARATION BAR - WHITE (REFL.) BACKGROUND - GREEN (REEL.) POST MOUNTED PUBLIC WORKS STREET NAME SIGNS DEPARTMENT 134 7/30/2018 1 DATF 4:0 HARMONY RIDGE A PORTION OF SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON DocuSign Envelope ID: 9D980DA8-0385-4664-AE66-57BFF1561D7F 6' MIN. (TYP.) -TIRE TRACKS CROSSWALK MARKINGS. (TYP-) SEE NOTE I (TYP.) i LANE LANE LINE LSE WHITE CROSSWALK CENTERED CENTERED MARKINGS(TYP.) IN IN LANE LANE 24' 1 R 8. 81 CONCRETE CURB 6 GUTTER (TYP.) � I WHITE STOP BAR FOR HAWK SIGNAL AND RECTANGULAR RAPID FLASHING BEACONS (RRFB), SEE NOTE 3 PMM STYLE CAOUNALK PLAN d PROFILE VIEW NOTES. 1. PIANO STYLE CROSSWALK MARKINGS SHALL BE INSTALLED AT MARKED MID -BLOCK PEDESTRIAN CROSSINGS. SEE STD. PLAN 128 FOR ALL OTHER LOCATIONS. 2 PAVEMENT MARKING MATERIAL SHALL BE PER STD. PLAN 109. 3. IT WIDE WHITE STOP BARS SHALL BE INSTALLED WHEN A HAWK SIGNAL OR RECTANGULAR RAPID FLASHING BEACONS (RRFB) ARE PRESENT AT A MID -BLOCK CROSSING OTHERWISE, NO STOP BARS SHALL BE INSTALLED, 4. TO MINIMIZE WEAR. CROSSWALK MARKINGS SHALL BE LOCATED IN THE CENTER OF THE TRAVELLED PORTION OF THE LANE. MID -BLOCK CROSSWALK AND STOP STD PLAN- 127 PUBLIC WORKS BAR PAVEMENT MARKINGS APPROVED: �. DEPARTMENT 7/27/2022 Martln ParstuUWa ",•^�"^ DAZE 5:4 CURS RAMP WIDTH 4' - 0" MIN, LANDING TO MATCH A NOTES CURB RAMP WIDTH - SEE CONTRACT PLANS CURB RAMP WIDTH 4'. 0" MIN. 1. At marked crosswalks, the connection between the curb ramp and the road. LANDING TO MATCH CURB RAMP way must be contained within the width of the crosswalk markings. LANDING I WIDTH - SEE CONTRACT PLANS Y LANDING GRADE BREAK C15N_ I 2. Where "GRADE BREAK" is called out, the entire length of the grade break GRADE BREAK SEE CONTRACT PLANS - GL�UF between the two adjacent surface planes shall be flush. 4' - 0" MIN. CEMENT CON SEE CONTRACT PLANS - SIDEWALK - SEE 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurten- 4' -B" MIN. ances on any part of the Curb Ramp or Landing, or in front of the Curb PROVIDE SMOOTH TRANSITION Ramp where it connects to the roadway. CEMENT CONCRETE TO SIDEWALK WIDTH 2'-D" SIDEWALK - SEE NOTE 5 I (TYP.) SEE CONTRACT I MIN.ACT 4. See Contract Plans for the curb design specified. See Standard Flan 4' -0"MIN. F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and FLARE (TYP.) 3J6" EXPANS* TH - MATCH Pedestrian Curb details. JOINT (TYP.) - MP DEPTH 3l8" EXPANSION CURB RAMP STANDARD PLAN F-3 (TYP-) 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See JOINT (TYP.) - SEE I Contract Plans for width and placement of sidewalk. STANDARD PLAN FJ0.10 GRADE °r �a 6. The Bid Item "Cement Concrete Curb Ram Type does not include the BREAK TRANSITION TO SIDEWAIF P YP GRADE BREAK PRESENT, OR TO BACK OF .- adjacent CUfb, CUfb and Gutter, DepfeSSed Curb and GUttef.Pedestfan C - --_ * iiiiiiiii(iiiii * SEE CONTRACT PLANS .a Curb, Or Sidewalks. .iii.......:... ...... _ •••••••• ••••• ••• _ ""' """' 7. The Curb Ram length is not required to exceed 15 feet unless shown CURB, OR CURB `------- _ _ CEMENT CONCRETE p 9 CURB, OR CURB otherwise in the Contract Plans). When applying the 15-foot max. length, AND GUTTER - - - - AND GUTTER - PEDESTRIAN CURB - the running slope Of the Curb Ramp is allowed to exceed 8.3%. Use a SEE NOTE 4 SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE NOTE 4 1 g I single constant slope from bottom of ramp to top of ramp to match into SEE STANDARD PLAN F45.10 DETECTABLE WARNING SURFACE - the landing Over a horizontal distance Of 15 feet. DO not Include the FACE OF CURB _ FACE OF CURB SEE STANDARD PLAN F46.10 abutting landing in the 15-foot max, measurement MEASURED PARALLEL DEPRESSED CURB AND GUTTER - DEPRESSED CURB AND GUTTER 8. Curb Ramps and Landings shall receive a broom finish. See Standard TO CURB (TYP.) CROSSWALK SEE NOTE 4 CROSSWALK Specifications 8-14- -1 L L 9. Pedestrian Curb may be omitted if the ground surface at the back of the w Curb Ramp and/or Landing will be at the same elevation as the Curb o O Ramp or Landing and there will not be material to retain. 7 1 CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN 140.10 z FOR CURB RAMP LENGTHS GREATER THAN B' - 0" PROVIDE LL PLAN VIEW CONTRACTION JOINT EQUALLY SPACED V - O- MIN. OC. PLAN VIEW TYPE PERPENDICULAR A TYPE PERPENDICULAR B LEGEND rD DETECTABLE WARNING SURFACE - (SHOWN WITH BUFFER) SEE STANDARD PLAN F46.10 _ SLOPE IN EITHER DIRECTION 4' - 0" MIN. 15' - 0" MAX (TYP,) GRADE BREAK * 1.5% OR FLATTER RECOMMENDED FOR DESIGNfFORMWORK (2% MAX.) SLOPE TREATMENT - SEE CONTRACT PLANS SEE NOTE 7 COUNTER SLOPE - 50%* OR FLATTER RECOMMENDED FOR W.MAX.. DESI SEE STANDARD PLAN F. .10 * GRADE BREAK DESIGNlFORMWORK (8.3% MAX.) *=_ TOP OF ROADWAY * * * 9,5% OR FLATTER RECOMMENDED FOR . DESIGNIFORMWORK(10% MAX.) SCO,�T 2�L LANDING CURB RAMP DEPRESSED CURB AND GUTTER 1 SECTION SEE STANDARD PLAN F-10.12 AO CEMENT CONCRETE PERPENDICULAR "A" PAY LIMICEMENT CONCRETE TS SEE NOTE P6 -A,, PERPENDICULAE CEMENT R "BC PAY ELIMITB SEE NOTE 6 W 9MP "TYPE oA� .8680ggI STBR�o PEDESTRIAN CURB - ,' G SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F-45.10 3" R. TYP DEPRESSED CURB AND GUTTER - SEE NOTE 4 CEMENT CONCRETE CURB AND GUTTER --SEE NOTE 4 CURB RADIUS DETAIL `8 1 BENCHMARK DATUM TOP OF 3/8" BRASS PLUG SET IN CONCRETE FOUND BRASS PIN 0.76' BELOW GRADE IN 4X4 MONUMENT AT INTERSECTION OF PUGET DRIVE CONC. MONUMENT IN MONUMENT CASE AT INTX 116TH HORIZONTAL DATUM: VERTICAL DATUM: SE AND SE 19TH ST (NAD 83/11) AVE SE & 157TH ST (JUNE 2022) (NAD 83/11) NAD '83/' 11 NAVD '88 N: 172240.27, E: 1304612.10 N: 171833.64, E: 1305874.10 ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT 1 I CITY REVIEW COMMENTS DATED 2 CITY REVIEW COMMENTS DATED REVISION ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT ►��ONAL B� D91e11y &goad by R-Stoll Zeller Date W2D.e 22 13 23Mi 7'DD' PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-04 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Date: 2020.09.25 14:44:37-07'00' 8TA7E DESIGN -NUR VrrWasMnglon Stale Depoflmenl el TrensperlaYen RK 9/26/25 TJS SURVEYED: ANG 1 /5/25 TJS DESIGNED: RK DRAWN: RK CHECKEDBJT BY DATE AP FIR �APPROVIED- TJS 10' - Cr MAX 1000' - D• MAX PULL POST -SPACED I END OR CORNER POST i TENSION WARE 10 - 0' MAX. ITYP.) 1000' (FT) MAX. A TENSION WARE PULL POST I B LINE POST - SPACED ! BRACE TENSION TWISTED SELVAGE D TENSION MIRE a IU (FT) MAX. ! POST WARE (TYP.) O TENSIONWARE TIE VIRE (TYP.) TENSION WIRE TENSION VN S2 >? = O TIE WIRE (TYP) FABRIC BAND a U (TYP.) FABRIC BAND MR) m BAR LL STRETCHER BAR (T(P.) STRETCHER (TYP.) All C TENSION WIRE'` HOG RINGS (TYP/ - ! I,• b KNUCKLED SELVAGE (TYP.) _i) CHAIN LINK TENSION FENCE FABRIC SPACED G 24" (IN) MAX. : y, IN i • - CONCRETE POST TYPE 3 10 - 0' MAX 5W - 0' MAX. PULL POST - SPACED END OR CORNER POST TENSION WIRE 10 - 0' MAX (TYP.) i 0 50D (FT) MAX. A TENSION WIRE PULL POST B LINE POST - SPACED BRACE�� VIA ICHUCIQED I D TENSION HARE ®10 (FT) MAX. POST SELVAGE TENSION HARE TIE WARE WIRE TENSION WIRE TENSION WIRE (TYP) STRETCHER X TIE WIRE BAR(TYP) v (TYP)( STRETCHER ' BAR (TYP.) FABRIC BAND (TYP) A.,C FABRIC BAND (TYP) NOTES HOG RINGS (TYP) - 1. All concrete past bases shall be 10" (in) PACED 024" (IN)MAX. minimum diameter. BRACE POST 2. Along the top and bottom, using Hog Rings, fasten the Chain Link Fence Fabric to the Tension Wire Within the limits of the first full fabric weave. 3. Details are illustrative and shall not limit hardware design or post selection RE of any particular fence type. 4. Fencing shall be used for security and boundary delineation only. TIE HARES (TYP.) - SPACED O 14" (IN) MAX. STRETCHER BAR WIRE jI: POST FABRIC FABRIC BAND WITH CARRIAGE BOLT AND _ NUT - SPACED 15" (IN) MAX. HOG RINGS (TYP.) - SPACED 0 24" (IN) MAX. BRACE POST KNUCKLED SELVAGE r CHAIN LINK ?' N (TYPO ?' FENCE FABRIC CONCRETE POST 1 BABE (YYP.) TYPE 4 POST AND RAIL SPECIFICATIONS 3 Ire 1 518• POE ROLL FORMED POST � UE (IISCi 40) SECTION WEIGHT 1H 0b;A) - FENCE LINE - FABRIC LOOP - 2 SIDES Y O END, CORNER, OR PULL POST 2 112' DUUA. 00.10 OZ LINE OR BRACE POST 2" DIAM. 1.85 BRACE BAND WITH TWO-WAY BRACE BAND WITH AND NUT _ CARRIAGE BOLTS AND NUTS TENSION WIRE TURNBUCKLE FABRIC BAND WITH BAR TENSION WIRES CARRIAGE BOLT AND NUT TRLT m 0 U FABRIC BAND WITH m CARRIAGE BOLT AND NUT (TYP.) 0 STRETCHER BAR (TYP.) END OR CORNER POST PULL POST (AT END OR CORNER) DETAIL O DETAIL O TIE WIRE - SPACED E 14" (IN) MAX. (TYP) TENSION WIRE // HOG RING - \c. SPACED C 24" (IN) MAX SCALE: N/A ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BRACE POST DETAIL OC VERTICAL: NAVD 19W HORIZONTAL: NAD 1983/2011 DATU M TENSION WIRE TWO-WAY BRACE BAND NTH 6/S5/ CARRIAGE BOLTS AND NUTS N TURNBUCKLE �- TURNBUCKLE TENSION HARES TENSION WIRES BRACE BAND WITH CARRIAGE BOLT AND NUT FABRIC BAND WITH CARRIAGE BOLT AND NUT (TYP.) STRETCHER BAR (TYP.) PULL POST (WITHIN RUN) DETAIL O CALL BEFORE YOU DIG: 1-800-424-5555 CITY OF RENTON Planning/Building/Public Works Dept. METHOD OF FASTENING STRETCHER BAR TO POST TIE WIRES (TYP.) - SPACED 0 W (IN) MAX. 4 Op IA'���,C 4 O q 34363 �e gGISTS �S70NAL e�� ,7 ,, Barry. Ed Jul 14_01H:14 AM CHAIN LINK FENCE TYPES 3 AND 4 STANDARD PLAN L-20.10-03 SHEET 1 OF 2 SHEETS APPROVED FOR PUBLICATION _ Carpenter. Jeff Jul 14 2015 11:24 AM -_ .:STATE DEBrBN ENOnHR wo.hinYbn 51d. Dpvbnr *fTn^Work6m MR TENSION WARE p1 WAS#, � s 5° ♦ 7� o q 34 w3 o �B q01 STB1`� ♦� �S70NAL Y�G any, Ed Jul 14 2015 11:14 AM CHAIN LINK FENCE TYPES 3 AND 4 STANDARD PLAN L-20.10-03 SHEET 2 OF 2 SHEETS APPROVED FOR PUBLICATION Carpenter, Jeff Jul 14 2015 11:25 AM �' - 'STATEDEBgNENQ It T Wu,Nhglen Sb D pa w,el Tra,wM"m O N S k Q- OF W A Sy1 O Z 100 4�0 6 STO, �Ql- s/DNA L ENG 1/6/26 • J O v Yl/ CA' W ^L W � • r_ O V, i W cN � M i 4-0 Q 00 �0) C4 >< tfV^ �J #A i > LO a-+ LO f V c0 Ma 00 U Y N r R-436033 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING N N N O O N LJ N J O O O O MMI t'J N r.� HBray 02/05/2026IV, AF 00 W CV ROAD AND DRAINAGE NOTES AND DETAILS HARMONY RIDGE ICHIJO USA, CO., LTD 1406 140TH PL SE, SUITE 104, BELLEVUE, WA 98007 (D N CV �0 Z DATE: 1/6/2026 z m FIELDBOOK: 0 O PAGE: DRAWING NO: Uj a� SHEET: 33 OF: 66 = W