Loading...
HomeMy WebLinkAboutT-436001i G.i z i w SE 1/4 SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M. ILLUMINATION CONSTRUCTION NOTES D CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1A. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03, AND PER CITY OF RENTON STANDARD PLANS 117.1, 117.1A, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD PLAN 121. )STREET CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 1 16. 1. FURNISH AND INSTALL NEW NEIGHBORHOOD PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03, AND PER CITY OF RENTON STANDARD PLANS 116.1, 116.2, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD PLAN 121. DCONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD PLANS 126.1 & 126.2. FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STANDARD PLANS 122.1 & 122.2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. )COORDINATE THE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL WITH PSE TO IDENTIFY FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR COMPLETION OF ALL NECESSARY FORMS/APPLICATIONS ASSOCIATED WITH THE NEW POWER SOURCE. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' OF TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING PURPOSES. 5O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE I LLU . SVC POWER 3/0 EQUIP. GRND. * DETECT. PULL WIRE CONDUIT ALLOW. FILL NO. NO. 1 2" SCH80 PVC 2 1 0.17 0.75 2 2" SCH80 PVC 4 1 1 0.28 0.75 3 3" SCH80 PVC 3 0.94 1.68 4 2" SCH80 PVC SPARE 1 --- 0.75 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT, (MIN SIZE #8). SERVICE BREAKER SCHEDULE NEW SVC LOCATED ON 116TH AVE SE CIRCUIT VOLTAGE BREAKER CONTACTOR MAIN 1201240 2P-200 AMP --- ILLUM A 240 2P-20 AMP 30 AMP ILLUM B 240 2P-20 AMP 30 AMP ILLUM C (SPARE) 240 1 2P-20 AMP 30 AMP :ONDITION OF APPROVAL 'HE APPLICANT SHALL PROVIDE ONE OF THE FOLLOWING: ) A LETTER FROM TENW STATING THAT STREET TREE CANOPIES WERE VCLUDED IN THE PHOTOMETRIC CALCULATIONS DATED 7/30/2025. 9 UPDATED PHOTOMETRIC CALCULATIONS MEETING CITY OF RENTON 1INIMUM STANDARDS THAT INCLUDES STREET TREE CANOPY COVERAGE. 0 UPDATED ILLUMINATION PLANS THAT FOLLOW THE CITY SUGGESTED ;TREETLIGHT SPACING 0 1 7. 1 WITH DUAL FIXTURES AT 120-FT SPACING VITH 1 17.2 PEDESTRIAN LIGHT AT 60-FT SPACING BETWEEN THE 1 17. 1. WO STREET TREES BETWEEN THE 1 1 7. 1 AND 1 17.2). THIS OPTION WILL JOT REQUIRE UPDATED PHOTOMETRIC CALCULATIONS. STREET TREE IDIALF117.1 E PEDESTRIANUDUAL FI%TURE JLLP 7 17.2 LP -UR 7. 20'-0• 1— 20'-0° — 20'-0" 1— 20'-0" 1120'-0° — 20'-0" I. 120'-0„ J ILLUMINATION WIRING DIAGRAM I I �— I I I 1 I 9 8 7 I I 6 I I I I W 5 I (n H --- __ LLJ F D B I Q ROAD G E AC -- A I� 1 4 I I J I NEW SERVICE CABINET WK 3 I AT 1 16TH AVE SE L ILLUM A ILLUM B M I I ILLUM C S cm N 2PAR Q Q O cx� 1 I\ P a I 1 I � N I I NOT TO SCALE MATCH LINE ROAD B STA 20+50 SEE SHEET I L — 02 0 10 20 40 60 SCALE IN FEET \le REVISION SURVEYED: OTHERS DESIGNED: D 149 DRAWN: D 149 CHECKED: SSO TD, BY DATE AP P R APPROVED: CTB MATCH LINE 116 STA 42+50 SEE BELOW RIGHT MATCH LINE 116 STA 39+40 SEE SHEET I L — 02 T-436001 SCALE: VERTICAS NOTED HORIZONTAL: TAL NAD 11983/1991 a C TY OF RENTON ONE INCH DATUM AT FULL SCALE Plan ning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY 0111 E. 4I �y 44JO I IID 01x / j nm,I �---` 3 I a IID I Z II 1 I I IID \ =1 TIC — T(UG) rIuGI a 5 1 ILy ILu I o I I c a L� 3� I I I I� o� I 43 1 0 I I I I � I I I I a► J W W—W—W I I, 1 I ► j o � al \ a � Lu MATCH LINE 116 STA 42+50 SEE ABOVE LEFT ILLUMINATION LEGEND EXIST. NEW/RELOCATED DESCRIPTION m 0 JUNCTION BOX TYPE 1,2 ROADWAY LIGHT STANDARD PEDESTRIAN LIGHT STANDARD UTILITY POLE UTILITY POLE MOUNTED LUMINAIRE — — — — — CONDUIT/CONDUCTOR ® SERVICE CABINET WIRE NOTE OCONSTRUCTION NOTE OPOLE NUMBER PROJECT NO. TENW 2025-053 2- Fs �.,c�STE��•v� S��NAL•�� 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 STELLA OH I STELLA@TENW.COM 1 206-412-6743 07-30 2025 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING c % ' All ' IL HBray 02/10/2026 DATE: HARMONYRIDGE 07130125 FIELDBOOK: RENTON, WA 98058 PAGE: DRAWING NO: ILL UM/NA T/ON PLAN IL-01 SHEET: 1 OF: C N 0 LO CV u co Q J O 0 i N