HomeMy WebLinkAboutT-436001i
G.i
z
i
w
SE 1/4 SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M.
ILLUMINATION CONSTRUCTION NOTES
D
CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1A. FURNISH AND INSTALL NEW ARTERIAL STREET
DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL-03, AND PER CITY OF RENTON STANDARD PLANS 117.1, 117.1A, 117.3, 119, 120 &
J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON
STANDARD PLAN 121.
)STREET
CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 1 16. 1. FURNISH AND INSTALL NEW NEIGHBORHOOD
PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET
IL-03, AND PER CITY OF RENTON STANDARD PLANS 116.1, 116.2, 119, 120 & J013. APPLY DECAL NUMBERING WITH
COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD PLAN 121.
DCONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD PLANS 126.1 & 126.2. FOUNDATION
SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON
STANDARD PLANS 122.1 & 122.2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY
CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS.
)COORDINATE
THE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL
WITH PSE TO IDENTIFY FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION. THE
CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR COMPLETION OF ALL NECESSARY FORMS/APPLICATIONS
ASSOCIATED WITH THE NEW POWER SOURCE. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE
POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL MAKE FINAL
CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' OF TRENCHING TO CONNECT TO POWER
SOURCE FOR BIDDING PURPOSES.
5O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN.
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
I LLU .
SVC
POWER
3/0
EQUIP.
GRND.
*
DETECT.
PULL
WIRE
CONDUIT
ALLOW.
FILL
NO.
NO.
1
2" SCH80 PVC
2
1
0.17
0.75
2
2" SCH80 PVC
4
1
1
0.28
0.75
3
3" SCH80 PVC
3
0.94
1.68
4
2" SCH80 PVC SPARE
1
---
0.75
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE
SIZE IN THE CONDUIT, (MIN SIZE #8).
SERVICE BREAKER SCHEDULE
NEW SVC LOCATED ON 116TH AVE SE
CIRCUIT
VOLTAGE
BREAKER
CONTACTOR
MAIN
1201240
2P-200 AMP
---
ILLUM A
240
2P-20 AMP
30 AMP
ILLUM B
240
2P-20 AMP
30 AMP
ILLUM C (SPARE)
240
1 2P-20 AMP
30 AMP
:ONDITION OF APPROVAL
'HE APPLICANT SHALL PROVIDE ONE OF THE FOLLOWING:
) A LETTER FROM TENW STATING THAT STREET TREE CANOPIES WERE
VCLUDED IN THE PHOTOMETRIC CALCULATIONS DATED 7/30/2025.
9 UPDATED PHOTOMETRIC CALCULATIONS MEETING CITY OF RENTON
1INIMUM STANDARDS THAT INCLUDES STREET TREE CANOPY COVERAGE.
0 UPDATED ILLUMINATION PLANS THAT FOLLOW THE CITY SUGGESTED
;TREETLIGHT SPACING 0 1 7. 1 WITH DUAL FIXTURES AT 120-FT SPACING
VITH 1 17.2 PEDESTRIAN LIGHT AT 60-FT SPACING BETWEEN THE 1 17. 1.
WO STREET TREES BETWEEN THE 1 1 7. 1 AND 1 17.2). THIS OPTION WILL
JOT REQUIRE UPDATED PHOTOMETRIC CALCULATIONS.
STREET TREE
IDIALF117.1 E PEDESTRIANUDUAL FI%TURE JLLP 7 17.2 LP -UR
7.
20'-0• 1— 20'-0° — 20'-0" 1— 20'-0" 1120'-0° — 20'-0"
I. 120'-0„ J
ILLUMINATION WIRING DIAGRAM
I
I �—
I I
I
1 I
9
8
7
I I
6
I I
I I
W
5 I (n
H --- __ LLJ
F D B
I Q
ROAD
G E AC -- A I�
1
4 I
I
J I
NEW SERVICE CABINET
WK 3 I AT 1 16TH AVE SE
L ILLUM A
ILLUM B
M I
I ILLUM C S
cm N 2PAR
Q Q
O
cx� 1 I\
P a I
1
I � N
I I
NOT TO SCALE
MATCH LINE ROAD B STA 20+50
SEE SHEET I L — 02
0 10 20 40 60
SCALE IN FEET
\le
REVISION
SURVEYED:
OTHERS
DESIGNED:
D 149
DRAWN:
D 149
CHECKED:
SSO TD,
BY DATE AP P R APPROVED:
CTB
MATCH LINE 116 STA 42+50
SEE BELOW RIGHT
MATCH LINE 116 STA 39+40
SEE SHEET I L — 02
T-436001
SCALE:
VERTICAS NOTED HORIZONTAL: TAL NAD 11983/1991 a
C TY OF
RENTON
ONE INCH DATUM
AT FULL SCALE Plan ning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
0111 E.
4I
�y 44JO I
IID
01x / j
nm,I �---`
3 I a IID
I
Z II
1
I I IID
\
=1
TIC — T(UG) rIuGI a
5
1 ILy
ILu I
o I I
c a L�
3� I I
I I�
o�
I 43 1 0 I I I
I � I
I I I a►
J W W—W—W I I,
1 I ► j o �
al
\
a �
Lu
MATCH LINE 116 STA 42+50
SEE ABOVE LEFT
ILLUMINATION LEGEND
EXIST.
NEW/RELOCATED
DESCRIPTION
m 0
JUNCTION BOX TYPE 1,2
ROADWAY LIGHT STANDARD
PEDESTRIAN LIGHT STANDARD
UTILITY POLE
UTILITY POLE MOUNTED LUMINAIRE
— — — — —
CONDUIT/CONDUCTOR
®
SERVICE CABINET
WIRE NOTE
OCONSTRUCTION
NOTE
OPOLE
NUMBER
PROJECT NO. TENW 2025-053
2-
Fs �.,c�STE��•v�
S��NAL•�� 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033
STELLA OH I STELLA@TENW.COM 1 206-412-6743
07-30 2025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING c % ' All
' IL
HBray 02/10/2026
DATE:
HARMONYRIDGE 07130125
FIELDBOOK:
RENTON, WA 98058 PAGE:
DRAWING NO:
ILL UM/NA T/ON PLAN IL-01
SHEET: 1 OF: C
N
0
LO
CV
u
co
Q
J
O
0
i
N