HomeMy WebLinkAboutT-436002a z J SE 1/4 SECTION 20, TOWNSHIP 23 N., RANGE ILLUMINATION CONSTRUCTION NOTES D CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1A. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03, AND PER CITY OF RENTON STANDARD PLANS 117.1, 117.1A, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD PLAN 121. )STREET CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 1 16. 1. FURNISH AND INSTALL NEW NEIGHBORHOC PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEE IL-03, AND PER CITY OF RENTON STANDARD PLANS 116.1, 116.2, 119, 120 & J013. APPLY DECAL NUMBERING WI1 COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD PLAN 121. (DCONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD PLANS 126.1 & 126.2. FOUNDATIC SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENT( STANDARD PLANS 122.1 & 122.2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED E CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OTHE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHA COORDINATE WITH PSE TO IDENTIFY FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION. TF CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR COMPLETION OF ALL NECESSARY FORMS/APPLICATION ASSOCIATED WITH THE NEW POWER SOURCE. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO Ti- POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL MAKE FINS CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' OF TRENCHING TO CONNECT TO POWE SOURCE FOR BIDDING PURPOSES. 5O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE I LLU . SVC POWER 3/0 EQUIP. GRND. * DETECT. PULL WIRE CONDUIT ALLOW. FILL NO. NO. 1 2" SCH80 PVC 2 1 0.17 0.75 2 2" SCH80 PVC 4 1 0.28 0.75 3 3" SCH80 PVC 3 0.94 1.68 4 2" SCH80 PVC SPARE 1 --- 0.75 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT, (MIN SIZE #8). ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION. 3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER. 8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL 425-430-7423, FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING. 13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 16. CITY OF RENTON REQUIRES STREET LIGHT POLE FOUNDATION DEPTH TO BE DETERMINED PER STRUCTURAL ANALYSIS. A STRUCTURAL ENGINEER AND/OR GEOTECHNICAL ENGINEER MAY BE REQUIRED TO PROVIDE THIS INFORMATION. 0 10 20 40 60 !!I SCALE IN FEET \lf REVISION MATCH LINE ROAD 8 STA 20+50 SEE SHEET IL-01 SURVEYED: OTHERS DESIGNED: D 149 DRAWN: D 149 CHECKED: SSO 0 BY DATE A P P R APPROVED: CTB 05 E.) W.M. MATCH LINE 116 STA 39+40 SEE SHEET IL-01 M:IN 1 1 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 3 13 � IW I 4xi Z I I I I I 2 � I i I I I I I I I I i 3 J I 4 � I J I 2 f it i VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M I I I 3 I I i I I 2 3 1 I I I 1 39+00 W 0 I _ I 0 I= W I cn I o T-436002 C TY OF RENTON • Plan ning/Building/Public Works Dept. ILLUMINATION LEGEND EXIST. NEW RELOCATED DESCRIPTION m 0 JUNCTION BOX TYPE 1,2 ROADWAY LIGHT STANDARD PEDESTRIAN LIGHT STANDARD UTILITY POLE UTILITY POLE MOUNTED LUMINAIRE - - - - - CONDUIT/CONDUCTOR ® SERVICE CABINET WIRE NOTE OCONSTRUCTION NOTE OPOLE NUMBER PROJECT NO. TENW 2025-053 h� 2: 35 Fs �.,c/STE��•v� Emw S��NAL•�� 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 STELLA OH I STELLA@TENW.COM 1 206-412-6743 07-30 2025 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING HBray 02/10/2026 DATE: HARMONYRIDGE 07130125 FIELDBOOK: RENTON, WA 98058 PAGE: DRAWING NO: ILL UM/NA T/ON PLAN IL-02 SHEET: 2 OF: C N 0 LO CV u Co N Q J O O co