Loading...
HomeMy WebLinkAboutT-436005CD (0 co I T I O rr I- O Z Q z DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY DECAL NUMBERS/LETTERS, SEE NUMBERING EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN DRY WEATHER, 50' F OR ABOVE-\ 1 2 3 4 C 5 s (3 z 7 MA>e91SW EXAWIE A-PEDESTRIAN SCALE CURB DECAL TRAFFIC �- FL�w WJ10RBRATIOM FOR POLES SMW M ON atD PLAM 11L1 90• PEDESTRIAN SCALE DECAL PEDESTRIAN SCALE CURB DECAL CURB TRAFFIC TRAFFIC ~ FLOW OD DECAL ORIENTATION IN M= SHOWN ON STDIAI.AN1172 TRAFFIC FLOW YDllM1M NEKW DETAL DECAL O111111111IfAT10N FOR POCES OH M11 ON SIO PLAN 117.1 i N7.1A 1-3/4' TO 2" DI ae" I N ; ROADWAY SCAMI DECAL PEDES'11UAMi SCALE DECAL DECAL NOTES; 1. DECALS SHALL BE REFLECTORIZED, GOTHIC FONT, COLD OR WHITE LEGEND ON BLACK BACKGROUND SCALE CALE o� LUMINAIRE STANDARD DECAL STD. PLAN - 121 !� PUBLIC WORKS NUMBERING SYSTEM APPROVED: P DEPARTMENT M 1011;aswcha 7/27/2022 1 N T' DATE DocuSign Envelope ID: 909BODA8-0385.4664-AE66-57BFF1561 D7F ELECTRICAL SERVICE/BBS CABINET CONTROLLER CABINET SHIM TO PLUMB SEE NOTE : 3 - /4 REINFORCING BAR (EQUAL SPACES) SEE NOTE 5 - NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SMALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REOUIREMENTS OF SECTION 8-14 3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4 ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5 CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2' SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STO PLAN 135. 7. 2- CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE/BBS CABINET TO THE CONTROLLER CABINET. S. EACH CABINET SHALL HAVE A is DIAMETER PLASTIC DRAIN PIPE. 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS 10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. 11. WOODEN SHIMS SHALL NOT BE USED IZ GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3, I& CONDUIT SIZES/QUANTITIES FOR ELECTRICAL SERVICE CABINETS SHALL IB BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2- SPARE CAPPED OUT PAST THE FOUNDATION, -SHIM TO PLUMB ES) NOTE 3 - 2" i- FRONT VIEW 3/8' DIAMEIER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 7 3/8' DIAMETER PLASTIC DRAIN SEE NOTE 13 3 - H REINFORCING BAR (EQUAL SPACES) PLAN NEW COMBINED CONTROLLER /ELECTRICAL GERM /BBS FOUNDATION CABINET FOUNDATION PUBLIC WORKS DETAILS DEPARTMENT NF= HOPo20NTAL COMBINED FOUNDATION REINF. BAR DIAGRAM 6 PIECES STD. PLAN - 126.2 APPROVED: Maros4atuchs 7/27/2022 DATE SE 1/4 SECTION 20y TOWNSHIP 23 N., RANGE 05 E.) W.M. DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 O z ® :o � � UWO O(IOa z 0 Ao -f Ui - �xxw 'jw0H ZZ(�Q> JHE-Z ppqq UI I � a�ivE"S >(6UQ Uw=aC] OQ�U a waw Lu F--Z�jH ll�w00II-- LL�- w O ZJI-w w xJLL Ow~�m jZO of ",'Qf2 Q-� cnnCEL fn`ri OZca g LL zF ECUwx wZ 0LL=0 LLw0z wj=� ww00 xzaC9 �Zw w w W zI�--. x= w w 0 " W az gxw0 dam PUBLIC WORKS p, tom DEPARTMENT 0 oB tau zt LLU Fin a ¢ zJa Wm r J 8< w 0 aLLu, U C SERVICE CABINET CV 04 z > a H N IY a 0 z Q 0. 0 a LL (n w I- O z X w CC th L6 a x a w z U) 0 N 0 DocuSign Envelope ID: 894DBTZE-3255-4A63-AOF1-3BA20AAF74CA GENERAL NOTES: 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE. 11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED, WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING PTZ CAMERA(S) REQUIRE RELOCATION. 12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL LANE AND SHALL BE MUTCD COMPLIANT. _ - TRANSPORTATION NOTES * PUBLIC WORKS DEPARTMENT REVISION STD. PLAN - 135 AF-UOVED: 5/2/2024 1 4 `Marlin Pastueha DATE DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 IL OMPU,NF N 1 St HEDU11. lO METERBASE: 200 AMP. 4 JAW, MANUAL BYPASS. B-LINE U264 W/ 51N JAW AT 9:00 POSITION O PANF.LBOARD: 120/240 VAC, 125 AMP COPPER HITS. I PHASE, 3 N IRE. IN c K 1, I0K AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 2012 ILLUMINATION A, B I - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE I -40/1 SIGNAL (IF PRESENT) 1 - 4011 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - IS/ CONTROL 3 - 20/1 SPARE 30 CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891 ODPA34VO2 - 1 REQUIRED CTRIC CELL: 18M WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL 0 PHOTO ELE MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 50 PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) O GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITII MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST' LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: FANGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM I - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE PUBLIC WORKS DEPARTMENT NS SURVEYED: OTHERS DESIGNED: D 149 DRAWN: D 149 CHECKED: SSO TD, BY DATE AP P R APPROVED: OT9 SERVICE CABINET NOTES DIAMETER = 7/8" 4-7/8" 1 /4" LOAD LINE 1 /4" FUSE CUTTING RINGS EPDXY FILL III I i I. INLWE SPLICE rnnvv nr I VYT� JF'LIVC - 122.2 SPLICE KIT FUSE KIT & SPLICE KIT DETAILS PUBLIC WORKS p, tom DEPARTMENT 0 oB tau zt LLU Fin a ¢ zJa Wm r J 8< w 0 aLLu, U C SERVICE CABINET CV 04 z > a H N IY a 0 z Q 0. 0 a LL (n w I- O z X w CC th L6 a x a w z U) 0 N 0 DocuSign Envelope ID: 894DBTZE-3255-4A63-AOF1-3BA20AAF74CA GENERAL NOTES: 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE. 11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED, WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING PTZ CAMERA(S) REQUIRE RELOCATION. 12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL LANE AND SHALL BE MUTCD COMPLIANT. _ - TRANSPORTATION NOTES * PUBLIC WORKS DEPARTMENT REVISION STD. PLAN - 135 AF-UOVED: 5/2/2024 1 4 `Marlin Pastueha DATE DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 IL OMPU,NF N 1 St HEDU11. lO METERBASE: 200 AMP. 4 JAW, MANUAL BYPASS. B-LINE U264 W/ 51N JAW AT 9:00 POSITION O PANF.LBOARD: 120/240 VAC, 125 AMP COPPER HITS. I PHASE, 3 N IRE. IN c K 1, I0K AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 2012 ILLUMINATION A, B I - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE I -40/1 SIGNAL (IF PRESENT) 1 - 4011 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - IS/ CONTROL 3 - 20/1 SPARE 30 CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891 ODPA34VO2 - 1 REQUIRED CTRIC CELL: 18M WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL 0 PHOTO ELE MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 50 PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) O GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITII MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST' LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: FANGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM I - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE PUBLIC WORKS DEPARTMENT NS SURVEYED: OTHERS DESIGNED: D 149 DRAWN: D 149 CHECKED: SSO TD, BY DATE AP P R APPROVED: OT9 SERVICE CABINET NOTES DIAMETER = 7/8" 4-7/8" 1 /4" LOAD LINE 1 /4" FUSE CUTTING RINGS EPDXY FILL III I i I. INLWE SPLICE rnnvv nr I VYT� JF'LIVC - 122.2 SPLICE KIT FUSE KIT & SPLICE KIT DETAILS AT]OPTED CITY OF RENTON STANDARD PLANS LET DATE: 04/04 _.. .___. nwr. NAAAF• .InlI CP Par: -In1'. SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM T-436005 C TY OF RENTON VASOF Plan ning/Building/Public Works Dept. DocuSign Envelope ID: 9D9BODAB-0385-4664-AE66.57BFF1561D7F CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 SEE STD PLAN 126.2 FOR ADDITIONAL NOTES PLAN VIEW SIZE TO FIT SIZE TO FIT CABINETCABINET 6" 6" 1'-0" 1'-0" "' -GRADE LEVEL FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES El SHIM TO PLUMB T SEE NOTE 3 o 4 HOOPS !A 4 BAR EACV CORNER `6" MIN - - - 1 TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET QEPTH 1'-6" + 2 1'-6" - - - - #4 BAR EACH } z + i I #4 CORNER m _ _ _ A _HOOPS " 10 III ! PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126.2 CONTROLLER CABINET FOUNDATION CABINET FOUNDATION STD. PLAN - 126.1 PUBLIC WORKS DETAILS APPROVED: p DEPARTMENT ManlnPastucha 7/27/2022 1 N DATE PROJECT NO. TENW 2025-053 5�d?\ T Bi ��•�oF1Wgsti •%17� w A.� i. Fs �.,c/STV_'w.•v�A EN S16NAL•t� 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 STELLA OH I STELLA@TENW.COM 1 206-412-6743 07-30 2025 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ri DEVELOPMENT ENGINEERING l HBray 02/10/2026 HARMONYRIDGE RENTON, WA 98058 ILL UM/NA T/ON DETAILS DATE: FIE0 D7130125 PAGE: IL-05 SHEET: c OF: C 1 LJ co Q J 0 (D C) L'J MMI N