Loading...
HomeMy WebLinkAboutSR_Consejo_Report_HEX_wExhibits_180724.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map SR_Consejo_Report_HEX_180724 A. REPORT TO THE HEARING EXAMINER HEARING DATE: July 24, 2018 Project Name: Consejo Counseling and Referral Services CUP Owner: Mario Paredes, 3808 S. Angeline St., Seattle, WA 98118 Applicant/Contact: Jennifer Weddermann, Weddermann Architecture, 1201 Regents Blvd. Ste. A, Fircrest, WA 98466 Project File Number: PR18-000196 Land Use File Number: LUA18-000290 Project Manager: Matt Herrera, Senior Planner Project Summary: The applicant is requesting Hearing Examiner Conditional Use Permit approval for the proposed Consejo Counseling and Referral Services Center. The subject property is located at 723 SW 10th Street. (Exhibit 2). The project site is located within the Medium Industrial (IM) zone. The approximately 18,000 gross square foot building is located on a 1.16 acre lot. The applicant proposes a change of use from the existing General and Medical Office to a Service and Social Organization. No exterior site construction improvements or building additions are proposed. Proposed interior improvements would support multiple outpatient services for adults and youth such as behavioral health, case management, Less Restrictive Alternative (LRA) support, cultural consultations, older adult day support, domestic violence advocacy, and psychiatric care. Access to the site would remain in the existing two driveways along SW 10th Street. The subject property contains 81 surface parking spaces. Project Location: 723 SW 10th Street, Renton, WA 98057 Site Area: 1.16 acres City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 2 of 10 SR_Consejo_Report_HEX_180724 B. EXHIBITS: Exhibits 1-8: As shown in the SEPA Environmental Review Report Exhibit 9: Report to the Hearing Examiner Exhibit 10 Public Comment Letters Exhibit 11 Determination of Non-Significance (DNS) C. GENERAL INFORMATION: 1. Owner(s) of Record: Mario Paredes, 3808 S. Angeline St., Seattle, WA 98118 2. Zoning Classification: Medium Industrial (IM) 3. Comprehensive Plan Land Use Designation: Employment Area (EA) 4. Existing Site Use: General and Medical Office 5. Critical Areas: High Seismic Hazard 6. Neighborhood Characteristics: a. North: Warehouse / IM zone b. East: Auto Service / CA zone c. South: Office Building / CA zone d. West: Auto Service / IM zone 6. Site Area: 1.16 acres D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Comprehensive Plan N/A 5758 06/22/2015 Zoning N/A 5758 06/22/2015 Annexation N/A 1745 04/19/1959 E. PUBLIC SERVICES: 1. Existing Utilities a. Water: Water service will be provided by the City of Renton. There is an existing 12-inch water main in SW 10th Street. The existing building is served by an existing 1-1/2” domestic water service b. Sewer: Sewer service is provided by the City of Renton. There is an existing 8-inch gravity sewer main in SW 10th Street. c. Surface/Storm Water: There are stormwater mains in SW Grady Way and SW 10th Street. A catch basin is located on the SE corner of the property. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 3 of 10 SR_Consejo_Report_HEX_180724 2. Streets: SW 10th Street is an Industrial Access street with an existing ROW width of 60-feet per the King County Assessor’s Map. There is currently an existing 6-foot wide sidewalk along the subject property’s frontage. 3. Fire Protection: Renton Regional Fire Authority F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-070: Zoning Use Table c. Section 4-2-130A: Industrial Development Standards 2. Chapter 3 Environmental Regulations a. Section 4-3-050: Critical Area Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 8 Permits – General and Appeals a. Section 4-6-060: Street Standards 5. Chapter 9 Permits – Specific a. Section 4-9-030: Conditional Use Permits 6. Chapter 11 Definitions G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element 2. Housing and Human Services Element H. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on April 30, 2018 and determined the application complete on May 10, 2018. The project complies with the 120-day review period. 2. The project site is located at 723 SW 10th Street. 3. The project site is currently developed with a general and medical office building. 4. Access to the site would not change and is provided via two driveways located near the east and west perimeters of the property onto SW 10th Street. 5. The property is located within the Employment Area (EA) Comprehensive Plan land use designation. 6. The site is located within the Medium Industrial (IM) zoning classification. 7. The site contains numerous existing mature trees along the perimeter, within the parking lot, and street frontage that were installed during the initial site development in 1985. No vegetation is proposed to be removed with the proposal. 8. The site is mapped with a High Seismic Hazard Area. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 4 of 10 SR_Consejo_Report_HEX_180724 9. The applicant is proposing interior improvements to the building with an intitial phase move in date scheduled for October 2018. Additional phased move-ins would continue as existing tenant leases expire through 2019. 10. Staff received three public comment letters (Exhibit 10) in support of the proposed project. 11. No other public or agency comments were received. 12. Pursuant to the City of Renton's Environmental Ordinance and SEPA (RCW 43.21C, 1971 as amended), on June 4, 2018 the Environmental Review Committee issued a Determination of Non-Significance - (DNS) for the Consejo proposal (Exhibit 11). A 14-day appeal period commenced on June 8, 2018 and ended on June 22, 2018. No appeals of the threshold determination were filed. 13. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 14. Comprehensive Plan Compliance: The site is designated Medium Industrial (IM) on the City’s Comprehensive Plan Map. The IM zone is intended for manufacturing, processing, assembly, and warehousing. Outdoor storage of some materials may be allowed. Uses and potential impacts of uses in this zone are contained within the property or project site. This zone implements the Employment Area Land Use Designation. The proposal is compliant with the following Comprehensive Plan Policies: Compliance Comprehensive Plan Analysis  Policy L-57: Compliment the built environment with landscaping using native, naturalized, ad ornamental planting that are appropriate for the situation and circumstance and which provide for respite, recreation, and sun/shade.  Policy HHS-18: Promote healthcare equity and increase the availability of medical and dental care, mental health and substance abuse services, early childhood screenings, and parenting support. 15. Zoning Development Standard Compliance: The purpose of the Medium Industrial Zone (IM) is to provide areas for medium-intensity industrial activities involving manufacturing, processing, assembly, and warehousing. Uses in this zone may require some outdoor storage and may create some external emissions of noise, odor, glare, vibration, etc., but these are largely contained on-site. Compatible uses that directly serve the needs of other uses permitted within the district are also allowed zone-wide. Additionally, within the Employment Area designation, an even wider variety of commercial and service uses may be permitted. The proposal is compliant with the following development standards, as outlined in RMC 4-2-130A: Compliance IM Zone Develop Standards and Analysis Compliant with CUP criteria, see FOF 17 Use: The applicant prsoposes a service and social organization use in an existing general and medical office building. Staff Comment: Pursuant to RMC 4-2-060 Zoning Use Table, a service and social organization use may be located in an IM zone with Hearing Examiner Conditional Use Permit Approval.  Lot Dimensions: The minimum lot size required in the IM zone is 35,000 sq. ft. There are no minimum lot width or depth requirements. Staff Comment: The lot size is 50,529 square feet. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 5 of 10 SR_Consejo_Report_HEX_180724  Setbacks: The minimum front yard setbacks are 20 feet along principal arterial streets and 15 feet along other streets, provided for lots adjacent to residentially zoned properties this setback increases to 50 feet. The minimum secondary front yard setbacks are 20 feet along principal arterial streets and 15 feet along other streets, provided for lots adjacent to residentially zoned properties this setback increases to 50 feet. There are no side or rear yard setback requirements, except 50 feet if abutting a lot zoned residential. Staff Comment: The front yard is abutting SW 10th Street, which is an industrial access street. The existing building is setback approximately 19 feet from this non-arterial street. A secondary front yard is located along the SW Grady Way frontage, which contains no vehicle or pedestrian ingress/egress. The building is setback approximately 94 feet from this principal arterial street. No abutting lots are zoned residential and therefore no setbacks are required along the east and west property lines.  Building Standards: There are no maximum lot coverage requirements for buildings in the IM zone. There are no maximum building height requirements in the IM zone. Staff Comment: Lot coverage for the building is approximately 30 percent (30%). The building is two stories and between 25 and 30 feet (25-30’) in height.  Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot landscape strip along all public street frontages. Additional minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060. Street trees and, at a minimum, groundcover, are to be located in this area when present. Spacing standards shall be as stipulated by the Department of Community and Economic Development, provided there shall be a minimum of one street tree planted per address. Any additional undeveloped right-of- way areas shall be landscaped unless otherwise determined by the Administrator. All parking lots shall have perimeter landscaping as follows: Such landscaping shall be at least ten feet (10') in width as measured from the street right-of-way. Standards for planting shall be as follows: a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi- family, commercial, and industrial uses at an average minimum rate of one tree per thirty (30) lineal feet of street frontage. b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped area. Up to fifty percent (50%) of shrubs may be deciduous. c. Ground cover in sufficient quantities to provide at least ninety percent (90%) coverage of the landscaped area within three (3) years of installation. Surface parking lots with more than fourteen (14) stalls shall be landscaped as follows: Surface parking lots with between 15 and 50 spaces shall provide 15 sf of landscaping per parking space, 51 and 99 spaces shall provide 25 sf of landscaping per parking space, and 100 or more spaces shall provide 35 sf of landscaping per parking space. Perimeter parking lot landscaping shall be at least 10 feet in width, interior parking lot landscaped areas shall have a minimum width of 5 feet. Staff Comment: The proposal does not include any exterior improvements that would require compliance with the current landscaping regulations. Changes in use can trigger compliance with current regulations if the improvements are equal or greater than 50 percent (50%) of the assessed property valuations. The proposed interior improvements City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 6 of 10 SR_Consejo_Report_HEX_180724 to the building are valued at approximately $500,000.00, which is less than 50 percent (50%) of the assessed property valuation of nearly $2.9 million per King County records. N/A Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-4- 130) require the retention of 10 percent of trees in a commercial development. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; and significant trees over sixty feet (60') in height or greater than eighteen inches ( 18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. Staff Comment: Not applicable, the applicant proposes to retain all trees with the project proposal. N/A Screening: All on-site surface mounted utility equipment shall be screened from public view. Screening shall consist of equipment cabinets enclosing the utility equipment, solid fencing or a wall of a height at least as high as the equipment it screens, or a landscaped visual barrier allowing for reasonable access to equipment. Equipment cabinets, fencing, and walls shall be made of materials and/or colors compatible with building materials. All operating equipment located on the roof of any building shall be enclosed so as to be screened from public view. Staff Comment: No new utility equipment is proposed with the project.  Refuse and Recycling: In office, educational and institutional developments, a minimum of two (2) square feet per every one thousand (1,000) square feet of building gross floor area shall be provided for recyclables deposit areas and a minimum of four (4) square feet per one thousand (1,000) square feet of building gross floor area shall be provided for refuse deposit areas. A total minimum area of one hundred (100) square feet shall be provided for recycling and refuse deposit areas. Staff Comment: The site currently provides approximately 375 square feet of refuse and recycling space located on the southeast corner of the property, which would comply with the current minimum requirements.  Parking: Service and social organizations is not an identified use in the City’s parking space quantity table set forth in RMC 4-4-080F.10.d. For those uses not specifically identified in the table, the code states that City staff shall determine which of the listed uses is most similar to the proposal and base the required number of spaces on that similar use. Staff Comment: The existing site contains 81 vehicle parking spaces with uses within the building that include a mix of general office and medical office uses. The net area of the existing building is approximately 16,200 square feet. The site currently contains a City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 7 of 10 SR_Consejo_Report_HEX_180724 parking ratio of 5 spaces per 1,000 square feet of net floor area (81 spaces /16.2 = 5 spaces per 1,000sf.). The applicant proposes to utilize the building as a service and social organization that would include services such as outpatient mental health therapy, case management, older adult day support, domestic violence services, Less Restrictive Alternative (LRA) support, and general administrative services for the organization. The proposed floor plan (Exhibit 5) identifies spaces with meeting rooms, receptionist space, and offices that are indicative of office uses. Medical office would be the most similar use identified in the space quantity table for the types of services that would be provided by the applicant. Pursuant to RMC 4-4-080F.10.d., general office uses shall provide between 2 and 4.5 spaces per 1,000 square feet of net floor area, which would result within a range of 32 to 65 spaces for the existing building. Medical office uses shall provide 5 spaces per 1,000 square feet of net floor area, which would result in 81 spaces for the existing building. The subject property’s existing parking capacity would comply with current medical office parking requirements, therefore no new parking would be required for the new use. N/A Fences and Retaining Walls: A maximum of eight feet (8') anywhere on the lot provided the fence, retaining wall or hedge does not stand in or in front of any required landscaping or pose a traffic vision hazard. There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Staff Comment: Not applicable, no fencing or retaining walls are proposed. 16. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations:  Geologically Hazardous Areas: Based upon the results of a geotechnical report and/or independent review, conditions of approval for developments may include buffers and/or setbacks from buffers. Staff Comment: A seismic hazard area is mapped on the project site. A geotechnical report was not required to be submitted with the formal land use application as no new buildings or expansions of the existing building is proposed. 17. Conditional Use Analysis: The applicant proposes to change the current general office and medical office use within the existing building to service and social organization. The use differs from general and medical office as the applicant is a non-profit social service organization that would provide a range of services including behavioral/psychiatric health services, case management, domestic violence advocacy, Less Restrictive Alternative support, cultural consultations, and older adult day support and services. While no exterior improvements to the property are proposed, a service and social organization use located within the IM zone requires Hearing Examiner Conditional Use Permit approval pursuant to RMC 4-2-060 – Zoning Use Table. The proposal is compliant with the following conditional use criteria, pursuant to RMC 4-9-030. Therefore, staff recommends approval of the requested Conditional Use Permit. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 8 of 10 SR_Consejo_Report_HEX_180724 Compliance Conditional Use Criteria and Analysis  a. Consistency with Plans and Regulations: The proposed use shall be compatible with the general goals, objectives, policies and standards of the Comprehensive Plan, the zoning regulations and any other plans, programs, maps or ordinances of the City of Renton. Staff Comment: See FOF 14 for Comprehensive Plan and FOF 15 zoning regulation compliance.  b. Appropriate Location: The proposed location shall not result in the detrimental overconcentration of a particular use within the City or within the immediate area of the proposed use. The proposed location shall be suited for the proposed use. Staff Comment: The applicant contends that the building was initially constructed for medical office use, which is similar to the services that would be provided with the proposal. Staff concurs that the proposed location will not result in an overconcentration of the proposed use. The area does not contain a cluster of behavioral health, psychiatric care, case management, and Less Restrictive Alternative services.  c. Effect on Adjacent Properties: The proposed use at the proposed location shall not result in substantial or undue adverse effects on adjacent property. Staff Comment: The applicant contends that the proposed location will not adversely effect on adjacent property and that the proposal is complementary to the neighbors. Staff concurs that the proposal would not result in adverse effects on adjacent properties. The services provided by the applicant are similar to the existing uses that have been within the building since its initial development in 1985.  d. Compatibility: The proposed use shall be compatible with the scale and character of the neighborhood. Staff Comment: The applicant contends that no exterior work is proposed and all work would be limited to the interior of the building and therefore the applicant would preserve the existing scale and character of the neighborhood. Staff concurs that the use would be compatible with the neighborhood. As stated by the applicant, the existing building has been there since 1985 and no exterior work would occur.  e. Parking: Adequate parking is, or will be made, available. Staff Comment: The applicant contends the existing parking lot is sufficient for the proposed use. Staff concurs that adequate parking capacity is provided on the existing site for the proposed use. The existing site contains one space per 200 square feet of net building square footage. While the City’s standards do not contain specific parking quantity requirements for service and social organization uses, the parking capacity contains adequate parking for similar uses such as general and medical office. See FOF 15 Zoning and Development Standards Compliance: Parking for analysis.  f. Traffic: The use shall ensure safe movement for vehicles and pedestrians and shall mitigate potential effects on the surrounding area. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 9 of 10 SR_Consejo_Report_HEX_180724 Staff Comment: The applicant contends the proposal will not generate more vehicular or pedestrian traffic than the existing general and medical office uses. Staff concurs that safe movement or vehicles and pedestrians will continue with the proposed use. The site contains pedestrian access from the abutting sidewalk on SW 10th Street. Two vehicle driveways bookend the subject property and each contain adequate width for two-way ingress/egress. No new trips would be generated by the proposal as the proposed use site description closest match in the ITE Trip Generation Manual is Medical – Dental Office as provided in the applicant transportation analysis (Exhibit 6). The proposal also passed the City’s Concurrency Test (Exhibit 7) which considers such factors as the citywide transportation plan and trip capacity within allowed growth levels.  g. Noise, Light and Glare: Potential noise, light and glare impacts from the proposed use shall be evaluated and mitigated. Staff Comment: The applicant contends that no new noise, light, or glare would be generated by the proposal. Staff concurs that the proposed use would not generate additional noise impacts to the surrounding neighborhood. Activities would be held indoors. Exterior noise impacts would be limited to vehicles arriving and departing the site and short term impacts related to the tenant improvements. The applicant has not proposed and has not shown the need for any additional lighting to utilize the existing building.  h. Landscaping: Landscaping shall be provided in all areas not occupied by buildings, paving, or critical areas. Additional landscaping may be required to buffer adjacent properties from potentially adverse effects of the proposed use. Staff Comment: The applicant contends the existing site is adequately landscaped with healthy mature vegetation that was planted with the initial building construction. Staff concurs that landscaping currently exists in areas not occupied by buildings or paving. Street frontage landscaping is provided between the building and SW 10th Street. internal landscaping is provided via curb bulbs, and mature evergreen trees are located on the west perimeter. Some frontage landscaping is provided along the slope between the parking lot and SW Grady Way. The existing landscape screen would not meet the planting requirements of the current code. However, additional landscaping would not be needed to buffer adjacent properties from any adverse impacts and the scope of the proposal does not require compliance with the current landscaping regulations per FOF 15 Zoning and Development Compliance: Landscaping. 18. Availability and Impact on Public Services: Compliance Availability and Impact on Public Services Analysis  Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist to furnish services to the proposed development; subject to the condition that the applicant provides Code required improvements and fees.  Storm Water: An adequate drainage system shall be provided for the proper drainage of all surface water. Staff Comment: The project does not propose to add or replace any impervious surface, therefore drainage review is not required. City of Renton Department of Community & Economic Development Hearing Examiner Recommendation CONSEJO CUP FILE NUMBER LUA18-000290,CU-H Report of July 24, 2018 Page 10 of 10 SR_Consejo_Report_HEX_180724  Water: The tenant improvement is not proposing any plumbing changes. The domestic and fire services are up to current standards. The Renton Regional Fire Authority has not required any changes to the fire flow demand for this project.  Sanitary Sewer: The tenant improvement is not proposing any plumbing changes or commercial kitchen. No upgrades to the sewer service is required. I. CONCLUSIONS: 1. The subject site is located in the Employment Area (EA) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 14. 2. The subject site is located in the Medium Industrial (IM) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code, see FOF 15. 3. The proposed Conditional Use complies with the Critical Areas Regulations provided the applicant complies with City Code, see FOF 16. 4. The proposed Conditional Use complies with the Conditional Use Permit criteria as established by City Code provided the applicant complies with all advisory notes, see FOF 17. 5. There are adequate public services and facilities to accommodate the proposed plat, see FOF 18. J. RECOMMENDATION: Staff recommends approval of the Consejo Counseling and Referral Services Center CUP, File No. LUA18- 000290, as depicted in Exhibit 3 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT STAFF REPORT TO THE HEARING EXAMINER EXHIBITS Project Name: Consejo Counseling and Referral Services CUP Project Number: LUA18-000290 Date of Hearing July 24, 2018 Staff Contact Matt Herrera Senior Planner Project Contact/Applicant Jennifer Weddermann, Weddermann Architecture, 1201 Regents Blvd. Ste A, Fircrest, WA 98466 Project Location 723 SW 10th Street Renton, WA 98057 The following exhibits were entered into the Hearing Examiner record: Exhibits 1-8 ERC Report and Exhibits Exhibit 9: Report to the Hearing Examiner Exhibit 10: Public Comment Letters Exhibit 11: Determination of Non-Significance (DNS) Exhibit 10 From: Benita Horn <brhorn2000@gmail.com> Sent: Thursday, May 24, 2018 4:10 PM To: Matthew Herrera Subject: Notice of Application for Consejo Mr. Herrera: I am writing in support of the application for Consejo Counseling & Referral Services at 723 SW 10th Street in Renton. Although I have not personally used their services, from all I have learned they have a solid track record of making a difference for youth and families of all culture and in particular for the Latino community. I recently attended a presentation made by staff of Renton School District and one of the priority needs they identified in our immigrant community is a local mental health resource for teens. Consejo is well prepared to meet this need and I ask that you give them positive consideration in opening a center in Renton. Sincerely, Benita Benita R Horn Principal Benita R. Horn & Associates (425) 277-2087 Fax (425) 277-2148 Regrets are a waste of time, they are the past crippling you in the present. Movie: Under the Tuscan Sun DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT SIGNATURES: Gregg Zimmerman, Administrator Public Works Department Date Rick M. Marshall, Administrator Renton Regional Fire Authority Date Kelly Beymer, Administrator Community Services Department Date C.E. Vincent, Administrator Department of Community & Economic Development Date ENVIRONMENTAL (SEPA) DETERMINATION OF NON-SIGNIFICANCE (DNS) PROJECT NUMBER: LUA18-000290, ECF, CU-H APPLICANT: Mario Paredes, 3808 S. Angeline St., Seattle, WA 98118 PROJECT NAME: Consejo Counseling and Referral Services CUP PROJECT DESCRIPTION: The applicant is requesting Hearing Examiner Conditional Use Permit approval and Environmental Review (SEPA) for the proposed Consejo Counseling and Referral Services Center. The subject property is located at 723 SW 10th Street (Exhibit 2). The project site is located within the Medium Industrial (IM) zone. The approximately 18,000 square foot building is located on a 1.16 acre lot. The applicant proposes a change of use from the existing General and Medical Office to a Service and Social Organization. No exterior site construction improvements or building additions are proposed. Proposed interior improvements would support multiple outpatient services for adults and youth such as behavioral health, case management, Less Restrictive Alternative (LRA) support, cultural consultations, older adult day support, domestic violence advocacy, and psychiatric care. Access to the site would remain in the existing two driveways along SW 10th Street. The subject property contains 81 surface parking spaces. PROJECT LOCATION: 723 SW 10th St., Renton, WA 98057 LEAD AGENCY: City of Renton Environmental Review Committee Department of Community & Economic Development The City of Renton Environmental Review Committee has determined that it does not have a probable significant adverse impact on the environment. An Environmental Impact Statement (EIS) is not required under RCW 43.21C.030(2)(c). This Determination of Non-Significance is issued under WAC 197-11-340. Because other agencies of jurisdiction may be involved, the lead agency will not act on this proposal for fourteen (14) days. Appeals of the environmental determination must be filed in writing on or before 5:00 p.m. on June 22, 2018. Appeals must be filed in writing together with the required fee with: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. Appeals to the Examiner are governed by RMC 4-8-110 and more information may be obtained from the Renton City Clerk’s Office, (425) 430-6510. PUBLICATION DATE: June 8, 2018 DATE OF DECISION: June 4, 2018 DocuSign Envelope ID: 8DE21126-E6F7-42B8-8881-F421FA1E75F0 6/4/2018 | 3:34 PM PDT 6/4/2018 | 4:32 PM PDT 6/5/2018 | 11:58 AM PDT 6/4/2018 | 12:36 PM PDT EXHIBIT 11