Loading...
HomeMy WebLinkAbout19_P_A2.01 - FLOOR PLAN -OVERALL_20260506_v1UP VO2 MA S VSO2MACG11 A4.21A4.01 1 A 1 2 B C 3 4 D A4.015 A4.01 6 WATER SERVICE 141 MED GAS 142 TREATMENT 112 BH TREATMENT 111 BH TREATMENT 110 TREATMENT 109 TREATMENT 108 MAJOR EXAM/ TREATMENT 115 TREATMENT 117 TREATMENT 116 TREATMENT 107 TRIAGE/ TREATMENT 104 PAT. TLT. 105 ISO. TLT. 106A EMERGENCY ELECTRICAL 132A WORKSTATIONS 139 MANAGER OFFICE 139A MANAGER OFFICE 139B PUBLIC TLT. 102 STAFF LOUNGE/ LOCKERS 138 X-RAY 122 CT SCAN 123 CONTROL ROOM 124 CHECK-IN/ REGISTRATION 103 RECORDS/ SUPPORT 140 SUPPLY STORAGE 127 CLEAN LINEN 130 MECHANICAL 134 MDF 133 PHONE BOOTH 139C CHARTING STATION 118 WAITING ROOM 101 EQ. ALCOVE 114D 4028 SF SHELL SPACE 000 ISOLATION TREATMENT 106 MEDS 120 LAB 119 STRETCHER ALCOVE 114A EQUIP ALCOVE 126A BREAK DOWN 127A EVS 129 ELECTRICAL 132BSOILED UTILITY 128 STAFF TOILET 136 STAFF TOILET 137 EQUIPMENT STORAGE 125 CORRIDOR 114 BH PATIENT TOILET 121 DECONTAM/ BARIATRIC PAT. TLT. 113 QUEUING 101B VESTIBULE 101A CORRIDOR 126 PRIVATE CORRIDOR 135 GENERATOR 143 EMERG. CARTS 114B 2HR FIRE RATED WALLL / 1 A2 . 1 2 /1 A2.13/2 A2.12 /1 A2.12 /1 A2.11 / 1 A2 . 1 1 / 2 A2 . 1 2 / 1 A2 . 1 3 HALLWAY 131 EQUIP. ALCOVE 114C 48' - 4 1/2"44' - 0"44' - 4 1/2" 40 ' - 4 1 / 2 " 40 ' - 0 " 40 ' - 4 1 / 2 " 8' - 6"12' - 5"12' - 5"12' - 5"12' - 5"12' - 5"12' - 5"12' - 5"11' - 0"12' - 5" 8' - 6 " 8' - 6 " 6' - 8 1 / 2 " 12 ' - 5 " 12 ' - 5 " 20 ' - 8 " 13 ' - 4 " 14 ' - 6 " LEGEND EXISTING PARTITION NEW PARTITION CARD READER CORNER GUARD TYPE 1. REFER TO G SERIES FOR ABBREVIATIONS, SYMBOLS AND GENERAL PROJECT NOTES. 2. REFER TO G SERIES SHEETS FOR CODE & ACCESSIBILITY STANDARDS. 3. REFER TO G SERIES FOR SPECIFIC WALL ASSEMBLY INFORMATION. 4. REFER TO ELEVATIONS FOR ACCESSORIES AND EQUIPMENT REQUIRING BLOCKING. WHEN USING METAL STUDS, REFER TO DETAIL SHEETS FOR BLOCKING REQUIREMENTS AND REGULATIONS. 5. REFER TO FINISH PLANS AND CEILING PLANS FOR WINDOW COVERING LOCATIONS AND TYPES. 6. REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALL, HOLD DOWN LOCATIONS, AND BEAM SIZES. NOTIFY ARCHITECT OF ANY CONFLICTS FOR RESOLUTION IN WRITING. 7. REFER TO M.E.P. AND OTHER DISCIPLINES' DRAWINGS FOR ADDITIONAL INFORMATION. 8. ALL WALLS TO BE P13 U.N.O. 9. ALL DIMENSIONS TO FACE OF STUD, U.N.O. 10. VERIFY IN FIELD (V.I.F.) ALL EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES GREATER THAN 1/2" PRIOR TO START OF NEW WORK. 11. FOR FRAMED WALLS: LOCATE HINGE SIDE OF ALL DOORS 4-1/2" FROM PERPENDICULAR FRAMING U.N.O. 12. FOR MASONRY WALLS: LOCATE HINGE SIDE OF DOOR 8” FROM PERPENDICULAR WALL U.N.O. 13. GUARDRAILS & HANDRAILS ARE TO BE PREFABRICATED SYSTEMS INSTALLED PER MANUFACTURER’S INSTRUCTIONS TO WITHHOLD A MINIMUM OF 250 POUNDS OF SIDELOAD PRESSURE. 14. PROVIDE CORNER GUARDS AT ALL EXPOSED GYPSUM BOARD OUTSIDE CORNERS IN PUBLIC AREAS. FLOOR PLAN NOTES PROJECT NO.: ISSUE DATE: REVISIONS: CL A R K K J O S A R C H I T E C T S , L L C C O P Y R I G H T 2 0 2 4 62 1 S W A l d e r S t . , S u i t e 7 0 0 Po r t l a n d , O R 9 7 2 0 5 Ph o n e : 5 0 3 / 2 2 4 - 4 8 4 8FOR REFERENCE ONLY5/ 5 / 2 0 2 6 5 : 3 4 : 5 5 P M C: \ U s e r s \ u r a n s o k o l i \ D o c u m e n t s \ R e v i t 2 0 2 5 \ M H S - R E N T O N -O C E D - R 2 5 _ u r a n s o k o l i L S 4 C Y . r v t FLOOR PLAN - OVERALL 05.06.2026 A2.01 CU P S U B M I T T A L 26002 OF F C A M P U S E M E R G E N C Y D E P A R T M E N T 31 1 6 N E S U N S E T B L V D , R E N T O N , W A 9 8 0 5 6 MU L T I C A R E & E M E R U S 1/8" = 1'-0"A2.01 1 OVERALL FLOOR PLAN KEY PLAN