HomeMy WebLinkAbout34_P_Utility plan_20260506_v1DE
S
I
G
N
E
D
B
Y
AP
P
R
O
V
E
D
B
Y
JO
B
N
O
:
DR
A
W
N
B
Y
CH
E
C
K
E
D
B
Y
DA
T
E
DRAWING
SHEET OF
CA
L
L
UN
D
E
R
G
R
O
U
N
D
LO
C
A
T
E
T
W
O
(
2
)
WO
R
K
I
N
G
D
A
Y
S
BE
F
O
R
E
Y
O
U
DI
G
81
1
64
0
W
o
o
d
l
a
n
d
S
q
u
a
r
e
L
o
o
p
,
Su
i
t
e
1
0
0
La
c
e
y
,
W
A
9
8
5
0
3
36
0
.
2
9
2
.
7
2
3
0
ww
w
.
k
p
f
f
.
c
o
m
CH
D
AP
P
R
BY
DA
T
E
NO
RE
V
I
S
I
O
N
P R O F ESSIONAL
E
N
G
I
NEER
REGI
S
T
E
R
E
D
T
O
S
AT
E
O
F
WASHIN GT N
5/
4
/
2
0
2
6
B
L
A
K
E
A
.
L O R D
8
SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
KING COUNTY , WASHINGTON
RE
N
T
O
N
,
W
A
CUP PERMIT SET
10
1
8
2
6
0
0
0
1
5
KK
KK BA
L
5/
4
/
2
0
2
6
CL
L
MU
L
T
I
C
A
R
E
R
E
N
T
O
N
O
C
E
D
SCALE
0 20 40
VERTICAL DATUM
NAVD 88
BASIS OF BEARING
WASHINGTON STATE PLANE
COORDINATE SYSTEM, NAD
83/91 NORTH ZONE 4601
6
C5.0
UT
I
L
I
T
Y
P
L
A
N
KI
R
K
L
A
N
D
A
V
E
N
E
EXISTING BUILDING TO BE IMPROVED
(INTERIOR & EXTERIOR). SEE ARCHITECTURAL.
NEW BUILDING FOOTPRINT AND OVERHANG SHOWN.
MAI PLACE ASIAN BISTRO
NE
S
U
N
S
E
T
B
L
V
D
NE 12TH ST
NE 13TH ST
ADJUST EX SEWER CLEANOUT
TO GRADE
EX RIM = 362.87
EX 6" PVC IE = 357.36
INSTALL 1.5" WATER SERVICE
REDUCED PRESSURE BACKFLOW
ASSEMBLY IN MECHANICAL ROOM.
SEE MEP.
LEGEND
RIGHT-OF-WAY
PROPERTY LINE
EXISTING GAS LINE
EXISTING POWER LINE
EXISTING SANITARY SEWER LINE
EXISTING STORM DRAIN LINE
EXISTING TELECOM LINE
EXISTING WATER LINE
EXISTING GAS METER
EXISTING POWER METER
EXISTING SEWER CLEANOUT
EXISTING STORM DRAIN CATCH BASIN
EXISTING STORM DRAIN MANHOLE
EXISTING TELECOM MANHOLE
EXISTING FDC
EXISTING PIV
UTILITY CONSTRUCTION NOTES:
1.EXISTING UTILITY CONNECTION TO BUILDING MAY REQUIRE REVISIONS
DUE TO INTERIOR IMPROVEMENTS. REVISIONS TO BE DETERMINED AT
CONSTRUCTION PERMIT LEVEL DESIGN.
1
1
REMOVE EXISTING REDUCED PRESSURE
BACKFLOW ASSEMBLY AND RECONNECT
WATER SERVICE TO EXISTING
EXISTING 8" FIRE SYSTEM
DCVA TO REMAIN
EXISTING STORM DRAINAGE
VAULT TO REMAIN
EXISTING FIRE AND DOMESTIC
WATER SERVICE LINE TO REMAIN
EXISTING STORM DRAINAGE
SYSTEM TO REMAIN (TYP)
EXISTING OVERHEAD
UTILITIES TO REMAIN (TYP)
CONNECT NEW BUILDING
ROOF DRAIN SYSTEM TO
EXISTING STUB AT BUILDING
1
11
1
1
PROPERTY LINE (TYP)
ROW LINE (TYP)
EXISTING STORM DRAINAGE
SYSTEM TO REMAIN (TYP)
EXISTING LIGHT POLES TO REMAIN.
FIXTURES TO BE REPLACED (TYP).
EXISTING LIGHT POLES TO REMAIN.
FIXTURES TO BE REPLACED (TYP).
SEE IRRIGATION PLANS FOR
IRRIGATION REVISIONS (TYP)
SEE IRRIGATION PLANS FOR
IRRIGATION REVISIONS (TYP)
1" IRRIGATION METER AND
BACKFLOW ASSEMBLY TO REMAIN.
SEE IRRIGATION PLANS.
EXISTING POWER AND TELECOM
UTILITIES TO REMAIN (TYP)
EXISTING TRAFFIC, POWER, AND
LIGHTING UTILITIES TO REMAIN (TYP)
1