Loading...
HomeMy WebLinkAbout34_P_Utility plan_20260506_v1DE S I G N E D B Y AP P R O V E D B Y JO B N O : DR A W N B Y CH E C K E D B Y DA T E DRAWING SHEET OF CA L L UN D E R G R O U N D LO C A T E T W O ( 2 ) WO R K I N G D A Y S BE F O R E Y O U DI G 81 1 64 0 W o o d l a n d S q u a r e L o o p , Su i t e 1 0 0 La c e y , W A 9 8 5 0 3 36 0 . 2 9 2 . 7 2 3 0 ww w . k p f f . c o m CH D AP P R BY DA T E NO RE V I S I O N P R O F ESSIONAL E N G I NEER REGI S T E R E D T O S AT E O F WASHIN GT N 5/ 4 / 2 0 2 6 B L A K E A . L O R D 8 SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. KING COUNTY , WASHINGTON RE N T O N , W A CUP PERMIT SET 10 1 8 2 6 0 0 0 1 5 KK KK BA L 5/ 4 / 2 0 2 6 CL L MU L T I C A R E R E N T O N O C E D SCALE 0 20 40 VERTICAL DATUM NAVD 88 BASIS OF BEARING WASHINGTON STATE PLANE COORDINATE SYSTEM, NAD 83/91 NORTH ZONE 4601 6 C5.0 UT I L I T Y P L A N KI R K L A N D A V E N E EXISTING BUILDING TO BE IMPROVED (INTERIOR & EXTERIOR). SEE ARCHITECTURAL. NEW BUILDING FOOTPRINT AND OVERHANG SHOWN. MAI PLACE ASIAN BISTRO NE S U N S E T B L V D NE 12TH ST NE 13TH ST ADJUST EX SEWER CLEANOUT TO GRADE EX RIM = 362.87 EX 6" PVC IE = 357.36 INSTALL 1.5" WATER SERVICE REDUCED PRESSURE BACKFLOW ASSEMBLY IN MECHANICAL ROOM. SEE MEP. LEGEND RIGHT-OF-WAY PROPERTY LINE EXISTING GAS LINE EXISTING POWER LINE EXISTING SANITARY SEWER LINE EXISTING STORM DRAIN LINE EXISTING TELECOM LINE EXISTING WATER LINE EXISTING GAS METER EXISTING POWER METER EXISTING SEWER CLEANOUT EXISTING STORM DRAIN CATCH BASIN EXISTING STORM DRAIN MANHOLE EXISTING TELECOM MANHOLE EXISTING FDC EXISTING PIV UTILITY CONSTRUCTION NOTES: 1.EXISTING UTILITY CONNECTION TO BUILDING MAY REQUIRE REVISIONS DUE TO INTERIOR IMPROVEMENTS. REVISIONS TO BE DETERMINED AT CONSTRUCTION PERMIT LEVEL DESIGN. 1 1 REMOVE EXISTING REDUCED PRESSURE BACKFLOW ASSEMBLY AND RECONNECT WATER SERVICE TO EXISTING EXISTING 8" FIRE SYSTEM DCVA TO REMAIN EXISTING STORM DRAINAGE VAULT TO REMAIN EXISTING FIRE AND DOMESTIC WATER SERVICE LINE TO REMAIN EXISTING STORM DRAINAGE SYSTEM TO REMAIN (TYP) EXISTING OVERHEAD UTILITIES TO REMAIN (TYP) CONNECT NEW BUILDING ROOF DRAIN SYSTEM TO EXISTING STUB AT BUILDING 1 11 1 1 PROPERTY LINE (TYP) ROW LINE (TYP) EXISTING STORM DRAINAGE SYSTEM TO REMAIN (TYP) EXISTING LIGHT POLES TO REMAIN. FIXTURES TO BE REPLACED (TYP). EXISTING LIGHT POLES TO REMAIN. FIXTURES TO BE REPLACED (TYP). SEE IRRIGATION PLANS FOR IRRIGATION REVISIONS (TYP) SEE IRRIGATION PLANS FOR IRRIGATION REVISIONS (TYP) 1" IRRIGATION METER AND BACKFLOW ASSEMBLY TO REMAIN. SEE IRRIGATION PLANS. EXISTING POWER AND TELECOM UTILITIES TO REMAIN (TYP) EXISTING TRAFFIC, POWER, AND LIGHTING UTILITIES TO REMAIN (TYP) 1