Loading...
HomeMy WebLinkAbout38_RS_Trip Generation Memo_MultiCare_260422 520 Kirkland Way, Suite 100, Kirkland, WA 98033 (425) 889-6747 www.tenw.com MEMORANDUM DATE:April 8, 2026 TO:City of Renton FROM:Spenser Haynie TENW SUBJECT:Trip Generation Memo MultiCare Renton (Renton, WA) TENW Project No. 2026-078 This memorandum summarizes the traffic information for the MultiCare Renton project. Upon review of this information, we would like to confirm that no additional traffic analysis is required for this project. Project Description The MultiCare Renton site is located at 3116 NE Sunset Blvd as shown in the Attachment A vicinity map. The proposed project includes an 18,000 square foot free-standing emergency room on a site that was formerly occupied by a Rite Aid retail store. Primary vehicular access will be provided via an existing driveway on NE 12th St and a shared access driveway on NE Sunset Blvd. A preliminary site plan is shown in Attachment B. Trip Generation The trip generation estimates for the proposed and existing uses for the MultiCare Renton project were based on methodology documented in the Institute of Transportation Engineers (ITE) Trip Generation Manual, 12th Edition for Land Use Code (LUC) 650 (Free-Standing Emergency Room) and LUC 881 (Pharmacy/Drugstore with Drive-Through Window). Adjustments to the trip generation estimates were made to account for pass-by trips, which are trips that are made by vehicles that are already on the adjacent streets and make intermediate stops at a commercial use on route to a primary destination (i.e. on the way from work to home). The pass-by reductions are based on studies documented in the appendices of the ITE Trip Generation Manual, 12th Edition for LUC 881 (Pharmacy/Drugstore with Drive-Through Window). Table 1 summarizes the net new weekday trip generation with detailed trip generation calculations provided in Attachment C. Table 1 Trip Generation Summary Net New Trips Generated Weekday Time Period In Out Total Daily -233 -234 -467 AM Peak Hour -7 -6 -13 PM Peak Hour -32 -29 -61 Trip Generation Memorandum MultiCare Renton (Renton) April 8, 2026 Page 2 Next Steps If you have any questions regarding the information presented in this memo or require any additional traffic analysis, please contact me at (206) 390-7253 or spenser@tenw.com with any questions. cc: Blake Lord, KPFF Attachments: A – Project Site Vicinity B – Preliminary Site Plan C – Trip Generation Calculations ATTACHMENT A Project Site Vicinity ATTACHMENT B Preliminary Site Plan S32 ° 0 6 ' 1 6 . 8 0 " W 248 . 2 9 ' S62° 4 7 ' 2 6 . 1 8 " W 36.02 ' S88° 54' 23.77"E 151.36' N1 ° 0 3 ' 1 4 . 9 9 " E 94 . 4 2 ' S88° 50' 55.00"E 39.97' S0 ° 5 7 ' 5 8 . 0 0 " W 80 . 4 7 ' S88° 46' 16.00"E 149.81'S5 8 ° 1 1 ' 4 7 . 0 0 " E 31. 8 6 ' S1 ° 0 3 ' 1 4 . 9 9 " W 5. 0 0 ' N88° 58' 58.01"W 57.50' N88° 58' 58.01"W 151.80' N1 ° 0 9 ' 3 3 . 1 6 " E 23 7 . 8 7 ' LEGEND RIGHT-OF-WAY PROPERTY LINE CEMENT CONCRETE CURB & GUTTER CEMENT CONCRETE CURB PAVEMENT MARKING BUILDING PER ARCHITECTURAL CEMENT CONCRETE CONCRETE PAVERS PER LANDSCAPE ARCHITECT ASPHALT PAVEMENT LANDSCAPING WHEEL STOP ADA PARKING SYMBOL STREET LIGHT TRAFFIC DIRECTION ARROW PARKING ANALYSIS: STANDARD:59 STALLS ADA ACCESSIBLE:7 STALLS TOTAL:66 STALLS TYPICAL STANDARD STALL SIZE: 20' X 9' TYPICAL ADA ACCESSIBLE STALL SIZE: 20' X 9' REQUIRED NUMBER OF ADA STALLS (10% OF TOTAL): 7 TOTAL (5 STANDARD, 2 VAN ACCESSIBLE) PROVIDED NUMBER OF STALLS: 7 TOTAL (5 STANDARD, 2 VAN ACCESSIBLE) DE S I G N E D B Y AP P R O V E D B Y JO B N O : DR A W N B Y CH E C K E D B Y DA T E DRAWING SHEET OF CA L L UN D E R G R O U N D LO C A T E T W O ( 2 ) WO R K I N G D A Y S BE F O R E Y O U DI G 81 1 64 0 W o o d l a n d S q u a r e L o o p , Su i t e 1 0 0 La c e y , W A 9 8 5 0 3 36 0 . 2 9 2 . 7 2 3 0 ww w . k p f f . c o m CH D AP P R BY DA T E NO RE V I S I O N P R O F ESSIONAL E N G INEER REGI S T E R E D T O SAT E O F WASHING T N PR E L I M I N A R Y B L A K E A . LO R D 7 SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. KING COUNTY , WASHINGTON RE N T O N , W A CUP PERMIT SET 10 1 8 2 6 0 0 0 1 5 KK KK BA L XX X X CL L MU L T I C A R E R E N T O N O C E D SCALE 0 20 40 VERTICAL DATUM NAVD 88 BASIS OF BEARING WASHINGTON STATE PLANE COORDINATE SYSTEM, NAD 83/91 NORTH ZONE 4601 5 C4.0 SI T E P L A N NE S U N S E T B L V D NE 12TH ST KI R K L A N D A V E N E NE 13TH ST BUILDING NOTES: ·AREAS PROVIDED TO SUPPORT PLANNING ONLY. SEE ARCHITECTURAL FOR EXACT FLOOR AREAS AND CALCULATIONS ·OCED: 18,000 SF MAXIMUM GFA (INCLUDES MECHANICAL EQUIPMENT SPACE ·SHELL SPACE: 4,000 SF MAXIMUM GFA (POTENTIAL PRIMARY CARE CLINIC) AREAS ANALYSIS: NEW & REPLACED PAVEMENT:13,101 SF NEW & REPLACED CONCRETE:5,369 SF TOTAL IMPERVIOUS:18,020 SF TOTAL REPLACED EXTRUDED CURB:646 LF TOTAL REPLACED PEDEST. CURB:127 LF 30' HALF OF ROW REMOVE AND REPLACE EXISTING APPROX 470 SF CONC ADA WALKWAY 4' TYP 5' S I D E W A L K ( T Y P ) 58 ' H A L F R O W 9' (TYP)5' (TYP) 20 ' 9' (TYP) 20 ' 9' (TYP) 20 ' APPROX 674 SF CONCRETE DUMPSTER PAD 25 ' H A L F R O W 5' SIDEWALK (TYP) 5' SI D E W A L K (T Y P ) PROPOSEED NEW PARKING ISLAND TWO PROPOSED PARKING STALLS PROPOSED LANDSCAPING AREA. REMOVE TWO EXISTING PARKING STALLS PROPOSED ADA PARKING (2 VAN ACCESSIBLE, 5 STANDARD) 7 TOTAL 6' 9' STAFF ENTRANCE 10' SIDEWALK PROPOSED PARKING ISLAND BUILDING OVERHANG PER ARCHITECTURAL STRUCTURAL COLUMN PER ARCHITECTURAL (TYP) PATIENT DROP OFFAMBULANCE DROP OFF 24' 24' 24 ' 24 . 5 ' 24 . 5 ' 20.4' 2 7 ' 20 . 8 ' 29 '18' 8' 8' 3.5' 12.5 ' 30 ' H A L F R O W MAI PLACE ASIAN BISTRO EXISTING BUILDING TO BE IMPROVED (INTERIOR & EXTERIOR). SEE ARCHITECTURAL DR A F T DRAFT CHECK SET ATTACHMENT C Trip Generation Calculations ITE Land Use Size/Units 1 LUC 2 In Out In Out Total DAILY Proposed Use: Free-Standing Emergency Room 18,000 GFA 650 24.94 50%50%225 224 449 Existing Use: Pharmacy/Drugstore with Drive-Through Window 16,755 GFA 881 107.20 50%50%-898 -898 -1796 Pass-by Trips3 49%440 440 880 Subtotal (less pass-by)-458 -458 -916 Net New Daily Trips =-233 -234 -467 AM PEAK HOUR Proposed Use: Free-Standing Emergency Room 18,000 GFA 650 1.12 50%50%10 10 20 Existing Use: Pharmacy/Drugstore with Drive-Through Window 16,755 GFA 881 3.83 52%48%-33 -31 -64 Pass-by Trips3 49%16 15 31 Subtotal (less pass-by)-17 -16 -33 Net New AM Peak Hour Trips =-7 -6 -13 PM PEAK HOUR Proposed Use: Free-Standing Emergency Room 18,000 GFA 650 1.52 46%54%12 15 27 Existing Use: Pharmacy/Drugstore with Drive-Through Window 16,755 GFA 881 10.24 50%50%-86 -86 -172 Pass-by Trips3 49%42 42 84 Subtotal (less pass-by)-44 -44 -88 Net New PM Peak Hour Trips =-32 -29 -61 Notes: 1 GFA = Gross Floor Area. 2 Based on Institute of Transportation Engineers (ITE) Trip Generation Manual, 12th Edition, 2025. 3 Pass-by trips determined based on studies documented in the appendices of the Institute of Transportation Engineers, Trip Generation Manual, 12th Edition. MultiCare Renton (Renton) Weekday Trip Generation Summary Directional Distribution Trips GeneratedTrip Rate or Equation 2