Loading...
HomeMy WebLinkAboutRC 20180705001100Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -1 of 6 Record Date:7/5/2018 2:23 PM Electronically Recorded King County, WA ERM City Clerk's Office Citi of Renton 10S5 5 Grady Way Renton, WA 58057 FOR INSPECTION AND MAINTENANCE Ix. ON-SITE BMPS Creator: Harbour Homes LLC Grantee: _,,C1jypfAgntqp jpp rqu jam.. rera Ion Legal Description- 70T b WILDWOOD VIEW, ACCORDING TO HK,AT THEREOF ECORD D IN VOLUME ME 232 OF ?7A,'W'S, PAGES 33 T":i:cC}B,,GH 37„ UNDER s G. NC). 2v1� $IbGT 2?ia a. CC RIS Je ��v Ct.e4'A Assessor's�` Parol t . 3 1 4 -� 0 06 ..� IN CONSIDERAMN of the approved City of Renton (deck one of the o9 »irsg) it sld nti l Suliding Permit []Commercial Building Permit Clearing and Grading Permit Civil Construction r Utility Permit Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -2 of 6 Record Date:7/5/2018 2:23 PM King County, WA c The owners shall assume all responsibilityo the City to address conditions as described In Paragraph 3, Such responsibility shall Include reimbursement to the City within thirty (30) days of the receipt maximumperformed. Overdue payments will require payment of Interest at the allowed by RCW 19.52.020 (currently twelve percent (12%)). If „« Initiates legal action to enforce this agreement, the prevailing party in such action is entitled to recover reasonable litigation costs and attorney's fees. S. The Owners are required o obtain written approval fromof Rentonprior to filling, plpft o(except ' ur pe maintenance) in open vegetated M ponds, alterations or modifications to the drainage facilities referenced In this Declaration of Covenant. µ Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -3 of 6 Record Date:7/5/2018 2:23 I'M King County, WA 6. Any notice or consent required to be given or otherwise provided for by the provisions of this Agreement shall be effective upon personal delivery, or three (3) days after mailing by Certified Maii, return receipt requested, 7, With regard to the matters addressed herein, this agreement constitutes the entire agreement between the parties, and supersedes all prior discussions, negotiations, and all agreements whatsoever whether oraC or wmitten, 8. This Declaration of Covenant is Intended to protect the value and desirability and promote efficient and effective management of surface water drainage of the real property described above, and shad inure to the benefit of all the citizens of the City of Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be binding upon Grantor(s), and Grantor's(s') successors In Interest, and assigns. 9m This Declaration of Covenant may be terminated by execution of a written agreement by the Owners and the City that Is recorded by King County in its real property records. IN WITNESS WHEREOF, this Declaration of Covenant for the Inspection and Maintenance of Drainage Facilities is executed this __V_h -day of .. 20_At_ GRI wPrope Prop�i TOW, oner of the rty GRANTOR, owner of the Property STATE OF WASHINGTON COUNTY OF KING )ss. to me known to be the Individual(s) i Niapd_Vt a AtQ'1 wom wo Given under my hand and officiat seat this - __��tdayof 20 01XS P Cj ot+ VON. il Printed name .0 �OTARY Notary Public In and for the State of Washington, residing at PuBoo ........ WAS My appointment expires � r1l/ Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -4 of 6 Record Date:7/5/2018 2:23 PM King County, WA TOTAL LOT AREA: 5,986 &F ADDRESS: 4753 SMITHERS AVE S, RENTON, PYA 98055 PARCEL NUMBER- PERMIT UMBEf':PE RMiT :• EXISTING PERVIOUS AREA: 0 S.F PROPOSED PERVIOUS AREA: 3.891 S.F. EXISTING IMPERVIOUS AREA: O S.F PROPOSED IMPERWOUS AREA.: 2,095 S.F: �� I �� �� 11 IF CONNECT PA TIC ROOF DRAIN TO 8" BYPA�S� L,VE END 3 IE 6.5011 UNDER RECORDING NO, 2018051800 893 lit `V a, `L 0 CONNECT ROOF DRAINS TO STORM STUB WxTH 6'0 PERFORA TED PIPEIN 2x10' TRENCH Y;IFE tO' ,JOINT UTILITY ESM'T HARBOUR HOMES, LLC 400 N .34TH STREET, SUITE 300 SEAT TLE; WA 98103 LEGAL DESCRIPTION: LOT 6, W'ILO WOOD VIEW; ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 282 OF PLATS, PAGES 33 THROUGH 37, UNDER RECORDING NUMBER 20180426000102, RECORDS OF KING COUNTY, WASHINGTON. FLOW CONTROL THIS PROPERTY CONTAINS A L1% CONTROL BMP KNOWN AS "RESTRICTED FOOTPRINT" , 7�IE TOTAL IMPERVIOUS SURFACE ON (Z> F,0 -1 - GRAPHIC THIS PROPERTY ALSO CONTAINS A 0 15 30 45 i a, W1 sI k CONNECT ROOF DRAINS TO STORM STUB WxTH 6'0 PERFORA TED PIPEIN 2x10' TRENCH Y;IFE tO' ,JOINT UTILITY ESM'T HARBOUR HOMES, LLC 400 N .34TH STREET, SUITE 300 SEAT TLE; WA 98103 LEGAL DESCRIPTION: LOT 6, W'ILO WOOD VIEW; ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 282 OF PLATS, PAGES 33 THROUGH 37, UNDER RECORDING NUMBER 20180426000102, RECORDS OF KING COUNTY, WASHINGTON. FLOW CONTROL THIS PROPERTY CONTAINS A L1% CONTROL BMP KNOWN AS "RESTRICTED FOOTPRINT" , 7�IE TOTAL IMPERVIOUS SURFACE ON (Z> F,0 -1 - GRAPHIC THIS PROPERTY ALSO CONTAINS A 0 15 30 45 Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -5 of 6 Record Date:7/5/2018 2:23 PM King County, WA CONNECTION Your property contains an on-site BMP (best management practice) called a "perforatedpipe connection," which was installed to reduce the stormwater runoff impacts of some or all of the impervious surface on your property. A perforated pipe connection is a length of drainage conveyance pipe with holes in the bottom, designed to "leak" runoff, conveyed by the pipe, into a gravel filled trench where it can be soaked into the surrounding soil, The connection is intended to provide opportunity for infiltration of any runoff that is being conveyed from an impervious surface (usually a roof) to a local drainage system such as a ditch or roadway pipe system. This on-site BMP shall be maintained per Appendix A of the City of Renton's Surface Water Design Manual. The size and composition of the perforated pipe connection. as depicted by the site plan and design details must be maintained and may not be changed without written approval from the City of Renton or through a future development permit from the City of Renton. The soil overtop of the perforated portion of the system must not be compacted or covered with impervious materials. These perforated pipe connection on-site BMP maintenance and operation instructions must be recorded as an attachment to the required declaration of covenant and grant of easement per Requirement 3 of Section C. 1.3.4 of the City of Renton Surface Water Design Manual. The intent of maintained and operated. These instructions are intended to be a minimum; the City of Renton may require additional instructions based on site-specific conditions. See the City of Renton's Surface Water Design Manual website for additional information and updates. E :T Y:PICA �LP PPIR �FO ORA ��TEDP �IP �EC �O�NM C'TION N ��FOR�A�Sl N G ��LEF �A�Mff_ Y �RESIDENCE slope random fill to road filter fab it syste m 18" min 4" pert pipe 2' x 10 1 1/2" - 3/4" washed rock level trench 9, w/perf pipe 24" min PLAN VIEW OF ROOF NTS TRENCH. X -SECTION NTS Instrument Number: 20180705001100 Document:COV Rec: $104.00 Page -6 of 6 Record Date:7/5/2018 2:23 PM King County, WA INT OE INSTRUCTIONS UCC IMPERVIOUS SURFACE BMP: RESTRICTED FOOTPRINT Your property contains an on-site B (best management practice) known as "restrdcterd foot, t," the practice of restricting the amount qf'impervious suaface that rrzcry be added to a property so as to minimize the stormwater runoff impacts caused by impervious surface. MAJNTENANCE RESTRICTIONS The total Impervious surface on your property may not exceed a square feet without written approval from the City of Renton or through a future development permit from the City of Renton. RECORDING REQUIREMENT These reduced impervious surface on-site BMP maintenance and operation instructions must be recorded as an attachment to the required declaration of covenant and grant of easement per Requirement 3 of Section C.l.3A of the City of Penton Surface Water Design Manual. The intent of these instructions is to explain to future property owners, the purpose of the. BMP and how it must be maintained and operated. "These instructions are intended to be a minimum; the City of Renton may require additional instructions based on site-specific conditions. See the City ofRenton's Surface Water Design Manual website for additional infannation and updates. �'- & 6,4