HomeMy WebLinkAboutR-392721SW 7/4 SECTION 9, TOWNSHIP 23 N, RANGE 5 E, W.M.
THE PINES
IRRIGATION SCHEDULE
DESCRIPTION
SPRINKLER HEADS:
RAINBIRD 1804 AND 1806 POP -UPS FOR SPRAY HEADS
SYMBOL MANUFACTURER
• 4" POP-UP
6" POP-UP
® 5005PC 4" ROTOR
PGA100 1" IRRIGATION CONTROL VALVE
MAINLINE - SCH 40 PVC (18" COVER); 1.25" SIZE
LATERAL - SCH 40 PVC (12" COVER); SIZE PER PLAN, 3/4" SIZE MINIMUM
_---------------- SLEEVE - CLASS 200 PVC; 24" MINIMUM COVER AT VEHICLE CROSSINGS, 2" SIZE UNDER DRIVEWAYS
LOCATED IN RIGHT-OF-WAY, 4" UNDER DRIVEWAYS LOCATED ON BUILDING LOTS
IRRIGATION SHOWN DIAGRAMATICALLY FOR PLAN CLARITY. COMMON TRENCH AND PLACE EQUIPMENT
IN LANDSCAPE; MANIFOLD GROUPED VALVES IN ADJACENT SHRUB AREAS WHERE FEASIBLE.
BIDDER -DESIGN IRRIGATION SYSTEM BY LANDSCAPE CONTRACTOR
POINT OF CONNECTION TO BE DETERMINED. WATER METER NOT SHOWN. INSTALL WATER METER
PER CITY OF RENTON STANDARDS. LANDSCAPE CONTRACTOR TO COORDINATE SIZE AND LOCATION
OF IRRIGATION WATER METER AND BACKFLOW DEVICE WITH OWNER
LANDSCAPE CONTRACTOR TO COORDINATE MAKE/MODEL AND LOCATION OF IRRIGATION
CONTROLLER WITH OWNER
ALL IRRIGATION CONNECTIONS AND FITTINGS SHALL BE LEAD-FREE
SCH 40 PIPE SIZING CHART
PIPE SIZE
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"
VALVE
FLOW
GPM
1-8
8.1-13
13.1-23
23.1-32
132.1-53
53.1-74
GPM (MAX.)
DOUBLE GRADE LEVEL BOXES
SIZE TO PERMIT 12" MINIMUM
EQ EQ CLEAR FROM WALLS TO TEST
COCKS, BOLT LOCK LID
DOUBLE CHECK VALVE (STATE APPROVED z
-I WATER SERVICE ASSEMBLY) RESILIANT SEATED VALVES WITH
TEST COCKS, INSTALL ASSEMBLY WITH z
FROM METER _ TEST COCKS IN HORIZONTAL POSITION, <
PER LOCAL REQUIREMENTS
_ O _ o_
I� b I�
a PVC MAINLINE PER PLAN caa
NOT TO SCALE
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
DOUBLE CARSON
GRADE LEVEL VALVE
BOXES
w
V
0 O°c o O°0 FINISH GRADE
00 )9,00
SCH 80
Z
Q
PVC UNION
VALVE
(BLOWOUT)
DOUBLE CHECK
METER
SCH 80 NIPPLE AND FEMALE
vCr"
CITY STANDARDS
SCH 80 PVC UNION
ADAPTER – TYPICAL
STOP
TYPICAL
�
P�
UNION AT EACH SIDE OF VALVE
(O �
�O O C
C
SCH 80 PVC – TYPICAL
THE BACKFLOW DEVICE SHALL
SCH 80 NIPPLE – TYPICAL
r
O
C
SIDES
O O C
o O
O COC
c O
BLOCK AS NECESSARY WITH BRICKS
AT BASE OF BOX
(V
O COOL
O O C
C
OCC SUMP 1 C.F. 7/8" WASHED GRAVEL
00 0.
O OO
� c0=1
:
o� .o,
NOTE:
PVC LATERAL
II III—III—
INSPECTION OF COMPLETED ASSEMBLY
. I=
BY CERTIFIED TESTER REQUIRED.
CHECK VALVE ASSEMBLY
DETAIL
NOT TO SCALE
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
DOUBLE CARSON
GRADE LEVEL VALVE
BOXES
TRENCH CONDITION
SLEEVE CONDMON
DATE:
0 O°c o O°0 FINISH GRADE
00 )9,00
SCH 80
LQUICK
COUPLv G
PVC UNION
VALVE
(BLOWOUT)
DOUBLE CHECK
METER
PER
VALVE PER DETAIL
CITY STANDARDS
SCH 80 PVC UNION
METER
STOP
TYPICAL
�
P�
��p
APPROVED:
JMv
PVC�
NOTE:
THE BACKFLOW DEVICE SHALL
HAVE
6" MINIMUM
UNOBSTRUCTED CLEARANCE
ON ALL
SIDES
TRENCH CONDITION
SLEEVE CONDMON
Co ¢ PIPE BED MATERIAL
TO BE CLEAN AND 0
FREE OF ROCK
} LARGER THAN 1/2"
NOTE:
SLEEVING MATERIAL SHALL BE PVC CLASS 160(SDR-26).
DIMENSIONS ARE MIN. CLEARANCES.
ALL IRRIGATION SLEEVING TRENCH BACKFILL MATERIAL SHALL
BE CLASS "B" OR BETTER (MAX. OF 10% PASSING NO.40 SCREEN) AND BE
COMPACTED TO MIN. 95% OPTIMUM DENSITY PER ASTM D-1557-70
(MODIFIED PROCTOR)
SLEEVE/TRENCHING DETAIL
NOT TO SCALE
— WILKINS 600
PRESSURE REDUCING
VALVE AS NECESSARY
T X S COUPLING:
CONTR. TO PROVIDE
THREADED FTG. AND CAP–f
ON DISCHARGE SIDE OF
METER. }
PER CITY STDS.
POINT OF CONNECTION (P.O.C.) DETAIL
NOT TO SCALE
2 AS -BUILT RELEASE
1 WATER SERVICE IN TRACT D
N0. REVISION
DATE:
0 O°c o O°0 FINISH GRADE
00 )9,00
SURVEYED:
BY:
DATE:
C) r PCpo
PAVING SECTION
DESIGNED:
JMV
JMV
PER CIVIL PLANS
JM
DRAWN:V JMv
JMV
� COMPACT BACKFILL
o
DO 0
CHECKED:
JMv
BY
�
P�
��p
APPROVED:
JMv
° ) 0AT 90% DENSITY
° O ° O
�
o°� (TOPSOIL BACKFILL)
AT 95% DENSITY
(STRUCTURAL)
° '°
H_
o _)0 o�
:
o� .o,
PVC LATERAL
6" OFFSET
SLEEVING
��0 roc
00'-
,00
ALT. WIRE SLEEVE
o c O
O
PVC MAINLINE
Q VALVE WIRING
Co ¢ PIPE BED MATERIAL
TO BE CLEAN AND 0
FREE OF ROCK
} LARGER THAN 1/2"
NOTE:
SLEEVING MATERIAL SHALL BE PVC CLASS 160(SDR-26).
DIMENSIONS ARE MIN. CLEARANCES.
ALL IRRIGATION SLEEVING TRENCH BACKFILL MATERIAL SHALL
BE CLASS "B" OR BETTER (MAX. OF 10% PASSING NO.40 SCREEN) AND BE
COMPACTED TO MIN. 95% OPTIMUM DENSITY PER ASTM D-1557-70
(MODIFIED PROCTOR)
SLEEVE/TRENCHING DETAIL
NOT TO SCALE
— WILKINS 600
PRESSURE REDUCING
VALVE AS NECESSARY
T X S COUPLING:
CONTR. TO PROVIDE
THREADED FTG. AND CAP–f
ON DISCHARGE SIDE OF
METER. }
PER CITY STDS.
POINT OF CONNECTION (P.O.C.) DETAIL
NOT TO SCALE
2 AS -BUILT RELEASE
1 WATER SERVICE IN TRACT D
N0. REVISION
POP-UP
6" CLEAR OF
OBSTRUCTION
MULCH CONDITION
FINISH GRADE
Z PAVING
rj�Nf J�
_ ADJUST ANGLE AT
`N SPRINKLER SLOPE COVERAGE
CONDITIONS. 5
FLUSH AT LAWN SLOPE ANGLE - TYPICAL
AND FLUSH WITH _
MULCH LINE -
SPRINKLER MARLEX 90° ELBOWS
PVC SCH 40
- PVC SCH 80 NIPPLE TEE SxSxT
o (SIDE INLET ONLY)
z
Ln
PVC LATERAL
V
)0O OOOOC
00 0
0 O 0
�o ono
l-
NOTE:
MANUFACTURER'S LIMITS PREVAIL FOR
INSTALLATION AND ADJUSTMENTS.
PROVIDE SWING JOINT RISERS AT WALKS AND CURBS.
24" FLEXIBLE RISERS ACCEPTABLE ELSEWHERE.
POP-UP RISER ASSEMBLY
NOT TO SCALE
NOTE:
ONE VALVE PER BOX.
PROVIDE EXTRA COILS (18") OF EACH WIRE IN VALVE BOX.
COMPACT SOIL AROUND VALVE BOX.
USE TEFLON OR FLOWABLE SEALANT IN ALL THREADED FITTINGS, PER
MANUFACTURES SPEC'S.
REMOTE CONTROL VALVE ASSEMBLY
NOT TO SCALE
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
PVC SCH 80 SxT 90° ELBOW
PVC SCH 80 UNION
WIRE WITH WATERPROOF
WIRE CONNECTOR – TYPICAL
FINISIH GRADE
SPARE WIRE WITH WATERPROOF
WIRE CONNECTOR ON CUT END
VALVE BOX
WITH COVER
PVC LATERAL
TO SPRINKLERS
PVC SCH 80 NIPPLE
AND FEMALE ADAPTOR
PVC SCH 80 UNION
PVC SCH 80 NIPPLE
REMOTE CONTROL VALVE;
BODY CLEAR OF SUMP
1 C.F. 7/8" WASHED GRAVEL
SUMP
PVC MAINLINE
PVC SCH 80 NIPPLE
C TY OF
RENTON
Planning/Building/Public Works Dept,
a Q
STATE OF
WASHINGTO
E S E E
LAN C C ECT
JEFF M. VA LEY
CERTIFICATE No. 774
R-3927- 21
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
BY:
DATE:
BY:
SURVEYED:
BY:
DATE:
BY:
DESIGNED:
JMV
JMV
5.26.18
JM
DRAWN:V JMv
JMV
1.6.18
JMV
CHECKED:
JMv
BY
DATE
APPR
APPROVED:
JMv
POP-UP
6" CLEAR OF
OBSTRUCTION
MULCH CONDITION
FINISH GRADE
Z PAVING
rj�Nf J�
_ ADJUST ANGLE AT
`N SPRINKLER SLOPE COVERAGE
CONDITIONS. 5
FLUSH AT LAWN SLOPE ANGLE - TYPICAL
AND FLUSH WITH _
MULCH LINE -
SPRINKLER MARLEX 90° ELBOWS
PVC SCH 40
- PVC SCH 80 NIPPLE TEE SxSxT
o (SIDE INLET ONLY)
z
Ln
PVC LATERAL
V
)0O OOOOC
00 0
0 O 0
�o ono
l-
NOTE:
MANUFACTURER'S LIMITS PREVAIL FOR
INSTALLATION AND ADJUSTMENTS.
PROVIDE SWING JOINT RISERS AT WALKS AND CURBS.
24" FLEXIBLE RISERS ACCEPTABLE ELSEWHERE.
POP-UP RISER ASSEMBLY
NOT TO SCALE
NOTE:
ONE VALVE PER BOX.
PROVIDE EXTRA COILS (18") OF EACH WIRE IN VALVE BOX.
COMPACT SOIL AROUND VALVE BOX.
USE TEFLON OR FLOWABLE SEALANT IN ALL THREADED FITTINGS, PER
MANUFACTURES SPEC'S.
REMOTE CONTROL VALVE ASSEMBLY
NOT TO SCALE
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
PVC SCH 80 SxT 90° ELBOW
PVC SCH 80 UNION
WIRE WITH WATERPROOF
WIRE CONNECTOR – TYPICAL
FINISIH GRADE
SPARE WIRE WITH WATERPROOF
WIRE CONNECTOR ON CUT END
VALVE BOX
WITH COVER
PVC LATERAL
TO SPRINKLERS
PVC SCH 80 NIPPLE
AND FEMALE ADAPTOR
PVC SCH 80 UNION
PVC SCH 80 NIPPLE
REMOTE CONTROL VALVE;
BODY CLEAR OF SUMP
1 C.F. 7/8" WASHED GRAVEL
SUMP
PVC MAINLINE
PVC SCH 80 NIPPLE
C TY OF
RENTON
Planning/Building/Public Works Dept,
a Q
STATE OF
WASHINGTO
E S E E
LAN C C ECT
JEFF M. VA LEY
CERTIFICATE No. 774
R-3927- 21
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
BY:
DATE:
BY:
DATE:
BY:
DATE:
BY:
DATE:
DATE:
THE PINES 12.23.16
LANDSCAPE PLAN (IRRIGATION) - AS -BUIL T PAGDBOOK:
DRAWING NO:
850 & 870 MONROE AVENUE NE
RENTON, WASHINGTON 98056 SHEET: L-4OF:5
W
M
H
H