Loading...
HomeMy WebLinkAboutT-392711W W 7' d ° ° ♦d ° 03' 00- d �I STREET LIGHT POLE LJUNCTION BOX PLAN VIEW SIDE VIEW LIGHTING STANDARD & JUNCTION BOX NOTE: CLASS 'B' CONCRETE TO BE USED IN CONSTRUCTION OF PAD 4" DEEP d ° • y e ° d z • ° ° and d° 4 1 d PLAN VIEW 1' INDIVIDUAL JUNCTION BOX ti�Y o STD. PLAN - 120 A® 4 PUBLIC WORKS CONCRETE PAD DETAILS OVED: Yp N�o� DEPARTMENT 4,44 DT � ZOO 1 4 U N1® om u i a ` - PUBLIC WORKS SERVICE CABINET STD. PLAN 122.1aP�n -- 4 ` I DEPARTMENT WITHOUT BBS F It Call 2 Working Days Before You Dig 811 tilities Underground Location Cente (ID,MT,ND,OR,WA) Taff NORTHWEST �X TRA FF/C EXPERTS 11410 NE 124th St., #590, Kirkland, WA 98034 Phone: 425.522.4118 Fax: 425.522.4311 REFER TO WSDOT LOCKING LID STANDARD DUTYJUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10-03 SP�UCCEE KITS CLEAR EPDXY HARE RUNS ON ALL THRU 4" CONCRETE PAD 2' MIN. #8 BARE COPPER — GROUND WIRE 1 REW EQUIPMENT GROUN� , WIREW/GREEN INSULATION FROM SERVICE CABINET 2 - LIGHTING SYSTEM - WIRES TO CONTACTOR (SIZED AS REO'D.) 5/8"4' COPPER CLAD GROUND ROD - ■ LUMINAIRE WIRES WILL BE A CONTINUOUS RUN o � a: z o 0 z : � O FUSE KITS WICK DISCONNECT TO LUMINAIRE 3 AMP IN LINE FUSE KITS LUMINAIRE VIRES WILL BE #12 S.E.C. OR EQUAL F - N N TO FIXTURE GROUND LUG zu W u d Il!8 jug zz3? �Wo� �< YQ= Q< § W S uN yNjwOz o NI w U2�/ _( t wQ 2Z�w zoo w¢ COQ' cco ZC F'o!� £ a % JY 23¢ w �c - �w�g o o o—o O—O o 1 O: om liLO zs fijNy;'-$ < t. ! O w♦- g SS 0—O Y a wp a m Isc»xcxi Cya�6� O �Fz�< UO w z �gP@GW qq o �'��S�A E �'� = zg o Qa S � oX J � al""0 1 Ow78Y3 - nnvNnn c a �40��m m oa `ao I O 0 wi > z ° m' z m a 0 � m t� L � z W i w q I in N ` - PUBLIC WORKS SERVICE CABINET STD. PLAN 122.1aP�n -- 4 ` I DEPARTMENT WITHOUT BBS F It Call 2 Working Days Before You Dig 811 tilities Underground Location Cente (ID,MT,ND,OR,WA) Taff NORTHWEST �X TRA FF/C EXPERTS 11410 NE 124th St., #590, Kirkland, WA 98034 Phone: 425.522.4118 Fax: 425.522.4311 REFER TO WSDOT LOCKING LID STANDARD DUTYJUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10-03 SP�UCCEE KITS CLEAR EPDXY HARE RUNS ON ALL THRU 4" CONCRETE PAD 2' MIN. #8 BARE COPPER — GROUND WIRE 1 REW EQUIPMENT GROUN� , WIREW/GREEN INSULATION FROM SERVICE CABINET 2 - LIGHTING SYSTEM - WIRES TO CONTACTOR (SIZED AS REO'D.) 5/8"4' COPPER CLAD GROUND ROD - ■ LUMINAIRE WIRES WILL BE A CONTINUOUS RUN FROM FUSE HOLDER TO FIXTURE MATH NO SPLICES. GROUND ROD FUSE KITS WICK DISCONNECT TO LUMINAIRE 3 AMP IN LINE FUSE KITS LUMINAIRE VIRES WILL BE #12 S.E.C. OR EQUAL AND IN A JACKETED CABLE #8 GREEN INSULATED WIRE TO FIXTURE GROUND LUG GROUND LUG - 1/4" MINIMUM HOILE- DRAM HOLE II�'ti Wil- �,�1 I I t —CLOUN AMP I II 2" PVC CONDUIT �I SYSTEM I� CONCRETE FOUNDATION 3 50. OR DIA. NOTES: 1. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2, IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. PUBLIC WORKS TYPICAL LIGHTING DEPARTMENT UNDERGROUND SYSTEM L OF CONCRETE FOUNDATION TO LEVEL VATH TOP OF SIDEWALK CURB. STD. PLAN — 119 APPROVED;, AS -BUILT 1 1 CITY OF RENTON COMMENTS 71ra REVISION E-nnv� CII I WYE SPLICE SPLICE KIT FEN %��■■■ i - I I ------- MINIMUM FUSE KIT & SPLICE KIT DETAILS Y O� ADOPTED CITY OF RENTON ♦ � Standard plans LST DATE: 1 1 /5/96 DWG. NAME: JR -12 SP PAGE: J013 STREET LIGHTING CONTACTOR CABINET WIRING SCHEMATIC TYPE III SERVICE 120/240 VOLT 100 A MAIN BREAKER (MIN.) 2 POLE 240 VOLT tt J FF <r - TERMINAL BRANCH BREAKERS FFF�--w 120/240 VOLT z TEST 16 POLE SWITCH F TERMINAL BLOCK— CIRCUIT WIRES TO LIGHTING RUNS PHOTO -CELL MOUNTED ON NEAREST LUMINAIRE II C UTILITY PLUG (GFI) STREET LIGHTING CONTACTORS TO GROUND ROD WIRING COLOR CODE A. WHITE JACKET (NEUTRAL) B. BLACK JACKET (LINE) C. GREEN JACKET (GROUND) D. RED JACKET (LOAD) E. GREEN OR BARE WIRE (GROUND) x STD. PLAN - 129 + 4 PUBLIC WORKS STREET LIGHTING CONTACTOR PROVE . DEPARTMENT CABINET SCHEMATIC f A VJG 4.25.17 LDH SURVEYED: DESIGNED: VJG DRAWN VJG CHECKED: LDH BY DATE APPR APPROVED: LDH SCALE: AS NOTED VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CONDUIT ENTR. AREA d d . a°o PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET'{ CABINET 6° 61,1'-0" —Grade Level 0 N ° N ° d ° FRONT VIEW SIDE VIEW Shim to plumb Shim to plumb See Note 3 See Note 3 }I #4 hoops }i #4 hoops o #4 bar each corner o #4 bar each comer 6" MIN 1" to 2" 1" to 2" ` 3/8" diameter plastic drain 3/8" diameter plastic drain SIDE VIEW 1�-6" Cabinet depth V-6° + 2" La 3 _ .. iv } a a U SIDE VIEW Cabinet depth V-6" } 2" #4 bar each r corner ' 3 _ ,, tV } a 0 V is #4 btlr each arner PLAN VIEW PLAN VIEW PAD MOUNT PAD MOUNT CONTROLLER CABINET FOUNDATION BATTERY BACKUP SYSTEM (BBS) FOUNDATION For NOTES see Std. Plan 126.2 iY PUBLIC WORKS CABINET FOUNDATION DETAILSSTD" P - 126_1 DEPARTMENT ROVE �N'fC CITY OF RENTON Planning/Building/Public Works Dept. T-3927-11 IN COMPLIANCE WITH CITY OF RENTON STANDARDS THE PINES ILLUMINATION DETAILS 850 & 870 MONROE AVENUE NE RENTON, WASHINGTON 98056 PAGE: 12.25.17 IL3 N LO O O T co T O O W D J �N\ 1M� O O O