Loading...
HomeMy WebLinkAboutT-393419PTN. OF SW 114 OF NW 114 OF SEC. 32, TWP 24N, R5E W. M. rn cY) d LU i LU LU a J a N z LU ILLUMINATION GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION ONE WEEK IN ADVANCE OF CLOSURE FOR REVIEW AND APPROVAL. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED ACCORDING TO THE APPROVED CITY OF RENTON TRAFFIC CONTROL PLAN. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE. 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 12. CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT LIMITED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC. 13. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH TRANSPORTATION MAINTENANCE DEPARTMENT MANAGER ERIC CUTSHALL AT (425) 430-7423. PSE/INTOLIGHT SCOPE OF WORK ILLUMINATION POLE SCHEDULE (INSTALLED BY PSE/INTOLIGHT) LUM. STREET STATION OFFSET MOUNTING ARM POLE LUMINAIRE TYPE COMMENT POLE NO. HEIGHT LENGTH EX UTILI GE�OL� XISTING LUMINAIRE ARM TO REMAIN. NEW FIXTURE 0LK 0 WA BLVD N EX EX EX EX POLE 4qSTALLED BY PSE/INTOLIGHT. E-RS2133W EXISTIING EVOLVE CONSTRUCTION NOTE '&1G 54W ERSPSEZINTOLIGHT PSE LUMINAIRE SHALL BE INSTALLED BY INTOLIGHT. A PSE/INTOLIGHT WORK SKETCH IS REQUIRED TO BE INCLUDED IN THIS DOCUMENT PACKAGE PRIOR TO CONSTRUCTION DOCUMENT APPROVAL. PSE/INTOLIGHT SHALL FURNISH AND INSTALL ALL MATERIALS. PROJECT CONTRACTOR SHALL COORDINATE WITH PSE/INTOLIGHT TO SCHEDULE INSTALLATION, INCLUDING COMPLETING ALL FORMS, PAYMENT OF ALL FEES, ETC. ASSOCIATED WITH THE INSTALLATION. PSEZINTOLIGHT GENERAL NOTE 1. PROJECT CONTRACTOR SHALL COORDINATE WITH PSE/INTOLIGHT TO SCHEDULE INSTALLATION, INCLUDING COMPLETING ALL FORMS, PAYMENT OF ALL FEES, ETC. ASSOCIATED WITH THE INSTALLATION. A PSEANTOLIGHT WORK SKETCH IS REQUIRED TO BE INCLUDED IN THIS DOCUMENT PACKAGE PRIOR TO COORDINATED CIVIL DOCUMENT APPROVAL. PSE/INTOLIGHT SHALL FURNISH AND INSTALL ALL MATERIALS BY CONTRACT WITH THE DEVELOPER. SERVICE 1 BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP 0 0 CALE ILLUMINATION POLE SCHEDULE (PLAT) LUM. POLE ID STREET STATION * OFFSET LATITUDE ** LONGITUDE ** LINT. HZGH7 VOLTA GE SERVICE/ WATTAGE INITIAL LUMINAIRE TYPE - BASE COMMENT POLE N . NUMBER*** CIRCUIT ITYPE LUMENS DISTRIBUTION Ol 5022A44 K WA BLVD N 46+39.5 27.0' T 47°31 '36.23767"N 122° 12'15.66597"W 1 .0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®25023A44 K WA BLVD N 46+96.5 24.5' T 47°31'36.69095"N 122°12'15.16774"W 4. 0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®3 5024A44 L WA BLVD N 47+55.0 24.5' 47°31'36.13965"N 122°12'14.63574"W 4.0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®4 5025A44 K WA BLVD N 48+09.0 24.5' T 47°31'37.55294"N 122°12'14.14174"W 1 .0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®5 5026A44 L WA BLVD N 48+63.0 24.5' T 47°31'37.96962"N 122°12'13.64943"W 4.0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®6 5027A44 K WA BLVD N 49+17.0 24.5' T 47°31'38.38601"N 122°12'13.15791"W 4. 0' 240 ILLUM A 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®7 5028A44 N 40TH ST 38+40.0 24.5' 47°31'38.92693"N 122°12'12.28001 "W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 0 5029A44 N 40TH ST 39+02.0 24.5' kT 47°31'38.92624"N 122°12'11.38366"W 0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. ®9 503OA44 N 40TH ST 39+66.5 24.5' T 47°31'38.92186"N 122°12'10.43534"W 4.0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. G5031A44 N 40TH ST 40+41.5 24.5'R 47°31'38.92584"N 122°12'09.33997"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. G 5032A44 N 40TH ST 40+99.5 24.5'T 47°31'38.92289"N 122°12'08.49083"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. G5033A44 N 40TH ST 41+68.5 24.5'T 47°31'38.92127"N 122°12'07.49066"W 4.0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. CX5034A44 N 40TH ST 42+31.5 24.5'47°31'38.91915"N 122°12'06.57037"W 4.0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. G5035A44 ARK AVE N 60+50.5 24.5'T 47°31'38.66405"N 122°12'06.22295"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. G5036A44 PARK AVE N 61+23.5 24.5'T 47°31'37.94958"N 122°12'06.23174"W 4.0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 16 5037A44 ARK AVE N 62+05.5 24.5' T 47°31'37.14057"N 122°12'06.24991"W 4.0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 17 5038A44 PARK AVE N 62+83.5 24.5' 47°31'36.36949"N 122°12'06.26773"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 18 5039A44 ELLS AVE N 99+47.0 16.5' T 47°31 '38.64368 "N 122° 12'09.71065 "W 0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 19 504OA44 WELLS AVE N 98+95.0 16.5' T 47°31'38.16830"N 122°12'10.20835"W 4. 0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 20 5041A44 ELLS AVE N 98+30.0 16.5' L 47°31'37.50101 "N 122°12'10.23167"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 21 5042A44 WELLS AVE N 97+87.0 16.5' T 47°31'37.04982"N 122°12'09.74996"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 22 5043A44 ELLS AVE N 97+43.5 16.5' T 47°31 '36.64695 "N 122° 12' 10.24523"W 4. 0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 2® 5044A44 ELLS AVE N 96+87.5 16.5' 47°31'36.09543"N 122°12'09.77040"W �4. 0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. a 5045A44 N 39TH CT 20+10.5 16.5' T 47°31'37.00639"N 122°12'10.68334"W 1 .0' 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. 25 5046A44 N 39TH CT 19+37.0 16.5' T 47°31'37.33975"N 122°12'11.67726"W 14.0 240 ILLUM B 44 LED 3,850 PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STD PLAN 116.1. * STANQNLS FFSETS ARE APPROXIMATE. CONTRACTOR AL ON ST TS H Y INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDED BY ERIC CUTSHALL, 425-430-7423 (CITY OF RENTON) FOR INSTALLATION BY THE CONTRACTOR AND INCORPORATION INTO AS -BUILT PLANS. VTENW Transportation Engineering NorthWest Transportation Planning I Design I Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 Project Contact: Glen DuBreuil Phone: 425-250-0582 Copyright© 2019 CPH Consultants, LLC. All Rights Reserved. CALL BEFORE YOU DIG 1-800-424-5555 RECORD DRAWING 1 1 2/28/19 NO. I REVISION I BY I DATE I APPR SURVEYED: DESIGNED: TREVIN ROLETTO, PE DRAWN: TREVIN ROLETTO, PE CHECKED: GLEN DUBREUIL APPROVED: CHRIS BICKET, PE SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ILLUMINATION WIRING DIAGRAM N 40TH ST 7 8 9 10 11 12 13 O P1 Z 18 NEW SERVICE 14 ILLUM A 6 19 > ILLUM B 11 O� � Q 15 z �\ 5 20 J W j �P Q 16 Q 4 >- VN9TH CT 21 3 N J 24 Q 17 C- 2 NOT TO SCALE 22 1 23 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M AS-BUILTS CERTIFICATION: I HEREBY CERTIFY THAT THE AS -BUILT MEASUREMENTS SHOWN HEREON ARE TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF AS SURVEYED IN THE FIELD IN JANUARY 2018 6���7 NAME LICENSE # 000 of WAJ w 0%i7--2018 CITY OF RENTON Planning/Building/Public Works Dept. 03-06 2019 DATE 4�G` TONAL � � 03-06 20 � 9 RECORD DRAWINGS T-393419 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SENZA LAKEVIEW ILLUMINATION PLAN CO O O T U') CO T C) O CO T Q J M, co O O CO N V1 DATE: 01/17/2018 Q FIELDBOOK: J PAGE: DRAWING NO: N -02 z SHEET: OF: LU 2 4 (n