Loading...
HomeMy WebLinkAboutR-397304I CONSTRUCnoN WA TER DRAINING TO VAUL T MUST BE PUMPED TO THE EXISTING D0WSTREAM CA TCH BASIN. FIL TER FABRIC PROTECTION PER C.O.R. STD. PLAN 216.20 (Typ) /A 00 co I • ✓ • i _ I —x— Jx— —x � X D PLI E TYP) I li I I II X ( ° Ij TEMPORARY STOCKP/LE co I.tip , , `row INTERCEPTOR SWALE // / I I / / / PROPOSED PER C.O.R. STD. PLAN I I / I / /� CONVEYANCE— �--- 215.10 (TYP.) /.. I i I I w titi I p--- .. -q I I �0�"SUMP / I I I' LOTI \ F \ , �PUMI� CONSTRUCnoN I �UNOfF TQ VAUL T. co n I � � I I �, Dlkf'CT� STORMWAT P F� �9 \ Q / I ' — TO VAUL T AT LID OPENING OR PROV/DE\, �� G�T \ �l / ���91 \TEMPORARY P/PE 9"soG / 21 CONNECTION /N CEILING /I &ANKS. \ \ I 1.5' ROW \ (DED/CA TION l y — —LEV-c I SS W 4 \ o w <o SS 0 2 RI E = 78.16 �o \ \ / CB #8011, TYP� I —W \ RIM EL=372. W R CHANNEL=368.90 \ W 8 E� W \ 8" CMP(S)IE�69.85 / 8" NW, OUT / \ SD B SCSB S W W / SB T SDMH #8010, TYPE II / RIM EL=372.16 \ v 8°CMP(N)IE=367.98 \ 18"CONC(E)IE=367.84 12"CMP(S)IE=36 \\ FILTER FABRIC 24"CONC(W)IE366.49 49 W/ \ PROTECTION PER C.O.R. \ \ / STD. PLAN 216.20 \ /�) \ l \ \ \ \ \ CORE JOB NO. 16114T 70rel STAG/NG AREA CLEARING LIMITS (TYP.) I� ml S/L T FENCE PER C. O.R. STD. PLAN 214.00 (Typ) CONSTRUCTION ENTRANCE PER C.O.R. STD. PLAN 215.10 TREE PROTECTION FENCE APPROXIMA TE DRIPLINE OF OFFSITE TREES IS q- ------- ss \ M w 16"WATERLINE w / w7 w w 12" WATERLINE w - w I—S-0 SQ / B SE FB SE SB SOUTHPUGET DRIVE (PUBLIC RIGHT OF WA Y� w w- 3 CH #8028, 7YPE I RIM EL= 03 8°" CMP(& =389.40 � N i SCALE: 1" = 20' 0 10 20 40 NOTES 1. THIS PLAN IS FOR WORK OCCURRING MAY 1ST — SEPT. 30Th! ANY WORK BEYOND SEPT. 30TH IMLL REOUIRE A HET WEATHER PLAN APPROVED BY THE CITY OF RENTON. 2. TURBIDITY LEVEL OF TREATED WATER LEAVING SITE MUST NOT EXCEED 25 N7Us. pH LEVEL MUST SE BETWEEN A MIN OF 6.5 AND A MAX OF 8.5. 3. SWPPP TO BE ONSITE DURING CONSTRUCTION 4. MEASURES SHALL BE PROVIDED IN THE FIELD TO PRE I/ENT SURFACE RUNOFF RUNNING FROM SUBJECT LOT TO ADJACENT PROPERTIES. 5. SEE GEOTECHNICAL REPORT BY EARTH SOLUTIONS NW FOR DESIGN, CONSTRUCTION, AND ANY EROSION CONTROL RECOMMENDATIONS 6. ANY DAMAGE TO CURB AND SIDEWALK DURING CONSTRUCTION WILL REQUIRE RESTORATION AS PER CITY OF RENTON STANDARD PLAN. 7. TREE PROTECTION FENCING SHALL STA Y INTACT FOR THOSE TREES WTH DRIPLINES W/TH/N THE BUILDING FOOTPRINT UNTIL AUTHORIZED TO BE REMOVED BY CITY STAFF. 8. A CERTIFIED ARSORIST SHALL BE ONSITE DURING EXCAVATING WORK ASSOCIATED WITH THE BUILDINGS LOCATED IWNIN THE DRIPLINE OF THE OFFSITE TREES. THE ARBORIST SHALL ASSESS THE CONDITION OF THE TREES AND PROVIDE A MEMORANDUM DETAILING ANY SPECIAL CONSTRUCTON CONSIDERATIONS AND BEST PRAC17CES TO PROTECT THE INTEGRITY OF THE OFF SITE 7REES PRIOR TO CITY STAFF AUTHORIZING REMOVAL OF TREE PROTECTION FENCING. ® I LEGEND ss — �o C o SS #8056 RI EL=397.46 % w C,TRCHANNEL=390.50 W �� w w w / / / I I o GCB #8019, TYPE I RIM EL=392.82 8"CMP(N)IE=387.33 18"CONC(S)IE=386.76 18"CONC(W)IE=386.52 CONSTRUC7ON ACCESS LIMITS OF CLEARING F/L TER FABRIC FENCE INTERCEPTOR SWALE ROCK CHECK DAM F/L TER FABRIC PRO TEC77ON l $IDEX0 ��•�FeWgsy�a9 A0A'pFg S46 4F FSS�ONAL ENS\ 11-72-1� CONSTRUCTION RECORD DRAWING CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,%oUKC PLANNING ""IIIIIIIzo� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-397304 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: DAP SCALE: VERTICAL: NAVD 1988 HORIZONTAL• NAD 1983/1991 DATU M %R) • CITY OF RENTON Planning/Building/Public Works Dept. EROSION/SEDIMENTA TION CONTROL & TREE PROTECTION PLAN DATE: SEPT 2017 DESIGNED: �G, FIELDBOOK: PAGE. DRAWN:SES ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DRAWING NO: C2 01 CHECKED: MAY REVISION BY DATE AP P R APPROVED: SHY SHEET; 4 OF: 22 N �o O O O CL A