Loading...
HomeMy WebLinkAboutR-397311LLJ 04 Q W 24" a^ U Y Z W m � W as N E m FRAME AND VANED GRATE S+ 6"OR12" PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR IT PLAIN CONCRETE ALL METAL PIPE 15" CPSSP'k IT (STD. SPEC. 9-05.20) SOLID WALL PVC 15" (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) a CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) m I K m HANDHOLD BOLT -DOWN SLOTSEE n � 1 DETAIL AND NOTE 1 O N g RECTANGULAR ADJUSTMENT SECTION C OR CIRCULAR ADJUSTMENT SECTION 1D a GROUT, TYPICAL (SEE NOTE 5) 2 1/2" DIA . HC UE w U G FLAT SLAB TOP W 20 �Q 48", 54', 60', 72°, 64" OR 96" Q J � O � pp x� Q MORTAR (TYP.) �paQ 4pOpOpO STEPS OR * CORRUGATED POLYETHYLENE LADDER O O Q O Q STORM SEWER PIPE ONE #3 BAR HOOP FOR 6" HEIGHT B TWO #3 BAR HOOPS FOR 12" HEIGHT TOP SECTION O RECTANGULAR ADJUSTMENT SECTION NOTES Z a 1. Provide two slots in the cover that are vertically aligned MORTAR FILLET REINFORCING STEEL (T1'P.) with the holes In the frame. Location of bolt -down slots 1146, \ " GRAVEL BACKFILL FOR varies among different manufacturers. sJ NOTES 72" PIPE ZONE BEDDING X 43/4" 11/2" -� " 2. Alternative reinforcing designs are acceptable in 1. As acceptable alternatives to the rebar shown in the PRECAST BASE 6" �6 lieu of the rib design. SECTION, fibers (placed according to the Standard Specifications), Or SEPARATE BASE INTEGRAL BASE I r - n wire mesh having a minimum area of 0.12 square inches per foot shall CAST -IN -PLACE PRECAST WITH RISER 3' 3. Refer to Standard Specification 9-05.15(2) for additional be used with the minimum required rebar shown in the ALTERNATIVE { requirements PRECAST BASE SECTION. Wire mesh shall not be placed in the '0' RING knockouts. 72" 4. For Frame details, see City of Renton #3 BAR EACH CORNER 39" R -SEE NOTE 2 z 2. The knockout diameter shall not be greater than 20". Knockouts shall GRAVEL BACKPILL FOR SECTION O Standard Plan 204.00. have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" 6� PIPE ZONE BEDDING N minimum gap between the knockout wall and the outside of the pipe. SEPARATE BASE After the pipe is installed, fill the gap with joint mortar in accordance PRECAST 93 BAR EACH SIDE with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. #3 BAR EACH WAY 4. The frame and grate must be installed with the flange down. PRECAST BASE SECTION 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. CATCH BASIN DIMENSIONS CATCH IN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCZE UT MINIMUM DISTANCE BETWEEN KNOCKOUTS BASE REINFORCING STEEL ln2ft IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48" 4" 6" 36" a" 0.23 0.15 54" 4.5" 8" 42" B" 0.19 0.19 60" 1. 8" 41, B. 0.25 0.25 72" 6" 8" 60" 12" 0.35 0.24 84" 8" 12" 72" 12" 0.39 0.29 96" 8" 12" 84" 12" 0.39 0.29 5" Q QQ 3 1/2" 1/2" DOQQQOQOQ oQQOQOQQOQQOQQQ 4" 3/4" DIAM. HOLE 1 1/4" QQQQ�QQ�QQ�Q�QQ�Q�QQ�Q�Q�Q 1/2" DIAM. HANDLE QQQQ� �Q QQQ�QQQ�QQ�QQQ��Q QQQQQQ�QQ�QQQQQQQQQ SECTION O QQ�QQQQ OQ Q BOLT -DOWN SLOT DETAIL ISOMETRIC SEE NOTE 1 5. All grade rings, risers, and castings shall be set In mortar In accordance with (D Corrugated Polyethylene Storm Sewer Pipe (Std. Spec. 9-05.20) SEE NOTE 1 Standard Specification 9-04.3. 2M (Bid. Spec. 9-06.12(l)) ALTERNATIVE PRECAST BASE SECTION ® (Bid. Spec.9-05.12(2)) STD. PLAN - 200.00 o~�Y �,,�, STD. PLAN - 201.00 G�`tY oi, STD. PLAN - 204.10 PUBLIC WORKS CATCH BASIN TYPE 1 PUBLIC WORKS CATCH BASIN TYPE 2 PUBLIC WORKS RECTANGULAR SOLID DEPARTMENT + DEPARTMENT ' DEPARTMENT METAL COVER MARCH 2O08 '�'�+N,Tp'� MARCH 2O08 "A�N,Lp MARCH 2O08 PATCHED AREA -7 11" VARIES m 4 7. All pickup holes shall be grouted full after the basin has been placed. 3/a^ ya„ OQQQ OQQQ OQQQ OQ �5/8" QQQQQQQQ QQQQQ QQQQQQQQ 8. All grade rings and castings shall be set in mortar in accordance with NOTES Standard Specification 9-04.3. 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. #3 BAR EACH CORNER 19, MIN. 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide #3 BAR HOOP a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. a MOIj w Y 0 0 OUTFACE TO STREAM 0 DUMP NO POLLUTANTS PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSO SOLID ALLPVC PROFILE ALL VC 48" 24" 30" 24" 27" 11, 11, 30" 36" 30" 27" 11, 60" 36" 42" 36" 36" 42" 72" 42" 54" 42" 36' 48" 84" 54" 60" 54" 36" 48" 96" 60" 72" 60" 36" 48" MINI MIN � MIN MIN + I SLOT-SEEDETAIL ;� SPECIAL NOTE: - AND NOTE 1 \ IN THE EVENT TRANSVERSE PATCHES EXIST / \ WITHIN THE AFFECTED STREET, THE LENGTH } A A / OF THE PATCH SHgLL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN 10 jj -• T OF THE EDGE OF THE PATCHREQUIRED FORNEW THE W CROSSING AND ANY SUBSEQUENT PATCH EDGE WITHIN 10 FEET- LD / OF THE EDGE OF THE SECOND PATCH AND { {l SO ON UP TO A TOTAL OF 300 FEET. FACE OF GUTTER OR / '•1 EDGE OF PAVEMENT COVER PER STD PLAN 401 � f TRAFFIC FLOW " (SEE NOTE 9) a 2" HMA CENTER LINE OR SEAL WITH AR 4000 OR APPROVED I LANE LINE TOP SECTION O EQUAL AND DRY SAND AFTER PLAN 2" TO 8" HMA r `, PATCHING NITS (SEE NOTE 9) OUTSIDE DIAMETER OF ADJUSTMENT RING AND X SEE NOTE 2 X BOTTOM OF FRAME 6.5' MIN. 2" DEPTH OF 24" PLANING OR SAWCUT AND REMOVE 4EQUAL SPACES 4EQUAL SPACES m VARIES: 6.5' MIN. - FMINJ 11DEPTH OF EXISTING PAVEMENT -� _ VARIES MIN I MIN SECTION O 3/4" 2" SAWCUT AND REMOVE OR PLANE, SEAL WITH 2" - 6" MIN. HMA (SEE NOTE 2) 11/4" MORTAR JOINT(S) (3/8" MIN.-2" MAX.) ADJUSTMENT RING (1" MIN.). SEE AR-4000W I SEE NOTE 3 AND SPECIAL PROVISION NOTE 6. (EACH SIDE) l 7-05.3(1). V CRUSHED SURFACING TOP COURSE (CSTC) m 2" HMA (9-03.9(3)) PER WSOOT STANDARD SECTION A -A SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROCTOR. SAWCUT AFTER BACKFILL NOTES (EACH SIDE) CSTC, BANK RUN GRAVEL FOR TRENCH BACKPLL 1. REMOVE PAVEMENT AND BASE MATERIALS FORA DISTANCE 5. CONSTRUCTION AND ADJUSTMENT SHALL BE PERFORMED (9-03.19). GRAVEL BORROW (9-03.14(l)) PER WHICH IS EQUAL TO THE DIAMETER THE FRAME PLUS ONE ONLY BY A JOURNEYMAN MASON. MATERIAL IF APPROVED IN WRITING BY ENGINEER BOLT -DOWN SLOT DETAIL FOOT (MIN.). ADJUST CASTING FRAMEE WSDOT STANDARD SPECIFICATIONS OR NATIVE TO PAVEMENT SEE NOTE 1 SURFACE USING RISER RINGS AND MORTAR. B. ADJUSTMENT OF THE FRAME TO GRADE SHALL BE BASED ON GEOTECH REPORT, COMPACTED TO 95%MODIFIED PROCTOR. ACCOMPLISHED WITH ADJUSTMENT RINGS AND MORTAR ONLY. 2. REPLACE EXCAVATED MATERIAL WITH A MINIMUM OF 8' OF THE USE OF SHIMS IS PROHIBITED. WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED NOTES HMA CLASS P PG 64-22 (OR TO A DEPTH THAT IS 2' BELOW IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) Provide two slots in the grate that are vertically aligned THE BOTTOM OF THE UPPER ADJUSTMENT RING WHICHEVER 7. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF PIPE ZONE BEDDING, MATERIAL- SEE STANDARD 1. with the holes in the frame. Location of bolt -down slots varies IS GREATER) OR AS APPROVED BY THE ENGINEER. TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT PLAN 110.1, among different manufacturers. DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. STANDARD SPECIFICATION 7-08.3(1)8 ISOMETRIC 3. ADJUSTMENT RINGS AND FRAME SHALL BE FULLY BEDDED IN TRENCH WIDTH 2. Refer to Standard Specification 9-05.15(2) for additional requirements. MORTAR. MORTAR SHALL BE ASTM C270 FOR TYPE S. 8. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. 3. Use only on sags and vertical curbs locations. 4. MORTAR SHALL BE MIXED AND APPLIED PER FOR NOTES, SEE STANDARD PLAN 110.1 MANUFACTURERS DIRECTIONS. 9. X= V-T MIN. TO 7-V MAX. - PER ENGINEER'S INSTRUCTION 4. Unless otherwise specified, vaned grates shall be used with standard frame STD. PLAN - 110 in the travel way, gutter or shoulder. vaned grates shall not be located STD. PLAN - 106 TYPICAL TRANSVERSE PATCH FOR PUBLIC WORKS within crossroads. Use vaned grates along rolled curbs. TYPICAL CONSTRUCTION ROVED: a FLEXIBLE PAVEMENT OR RIGID PR ED PUBLIC WORKS DEPARTMENT titY p DEPARTMENT AND ADJUSTMENT OF14 PAVEMENT WITH OVERLAY PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL STD. PLAN - 204.30 MANHOLE RISERS ^ V p�rF DEPARTMENT VANED GRATE DA MARCH 2O08 CORE JOB NO. 16114T SURVEYED: DAP SCALE. VERTICAL, NAVD 1988 HORIZONTAL NAD 1983/1991 DESIGNED: WG, DRAWN: SES ONE INCH DATU M CHECKED: MAY AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SHY SCALE ACCORDINGLY MAX W" S" EL. 383" 05 C7 0° 5' MIN. REMOVABLE WATER AGHT COUPLING PLATE WITH OR/FILL: AS SPECIFIED, BOLTED TO FLANGE OR DRILLED CAP ELBOW )F 384 ELBOW IE 381.25 ELBOW IE 380.30 18" CMP 2' TOP OF RISER EL. 38J 05' 4" ELBOW WITH 7116-0 ORIFICE SEE ELBOW DETAIL, THIS SHEET 4" ELBOW WITH 7116"0 ORIFICE SEE ELBOW DETAIL, THIS SHEET 4" ELBOW WITH 31810 ORIFICE SEE ELBOW DETAIL, THIS SHEET 18x18x12 x8" CUP CROSS 12" IE 376.75' (AB)If NON-POUROUS, NON - SHRINKING GROUT AROUND �I PIPE AS REO D (TYP°) 8 GAUGE ALUMINUM STRAPS WITH STAINLESS STEEL ANCHOR BOLTS. (TYR) MAX. 3' VERTICAL SPACING 1' SEC77ON OF PIPE ATTACHED BY GASKETED BAND TO ALLOW REMOVAL. DRILL OR MACHINE CUT 5116 "0 ORIFICE IN RESTRICTOR END PLATE, EL. 374+75' CONTROL STRUCTURE DETAIL (PRIVATE) ELBOW DETAIL (STY p�CITY OF RENTON �E k T Oct Planning/Building/Public Works Dept. NOT TO SCALE l SIDEKO �0�FsP�C C41846 R�0�� �S/ONAL ENG� 11-IZ-1� NO SCALE NOTES 1. METAL PARTS SHALL BE CORROSION RESISTANT; NON-GAL VANIZED PARTS PREFERRED, GALVANIZED PIPE PARTS TO HA VE ASHPAL T TREATMENT 1° 2° FRAME AND LADDER OFFSET SO°° G. CLEANOUT GA TE IS VISIBLE FROM TOP. b. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GRATE. 3. PA VEMENT RESTORA TION AS PER CITY OF RENTON STANDARDS IMLL BE REQUIRED FOR ANY WORK IMPACTING THE PA VEMEN T IN THE PUBLIC RIGHT OF WA Y° 4° ALL STORMWATER PIPES AND STRUCTURES INTERNAL TO SITE ARE PRIVATE CONSTRUCTION RECORD DRAWING DESIGN CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R- 3 97311 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SITE DETAILS AND NOTES DATE: SEPT. 2017 FIELDBOOK: PAGE: DRAWING NO: C4.32 SHEET: 11 OF: 22 N �O O O CL W