Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-397315
I / aiLATERAL PIPE (TYP.) --jai a ° q I Iii PIPE SLEEVE (TYP.) C2 101 EE EE 1 NO. I REVISION IRRIGATION SCHEDULE CRITICAL ANALYSIS SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI 1° A a a a a 4 7.48 13 I 3i4"a a j I d p I I 18 30 4 p 4 3�4"14 I I ES LCS RCS CS SS ° ,..Q I IRRIGATION VALVE (TYP.) FLOW AVAILABLE a a a ° ° I 4. ° °a ° 1 I I "3 f4 MAINLINE (TYP.) 3/4" 6.30 14 Q Q3/4' Flow Available: 11.88 gpm HUNTER MP1000 PROS-04-PRS40-CV 2 ° a TURF ROTATOR, 4" (10.16 CM) POP-UP WITH CHECK VALVE, PRESSURE PRESSURE AVAILABLE Al REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. El Static Pressure at POC: ❑ M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE D a a Elevation Change: 0.00 ft 360 ARC. Service Line Size: 3/4" Length of Service Line: SPRAY HEAD (TYP.) HUNTER MP2000 PROS-04-PRS40-CV 2 41 Pressure Available: 86.00 psi � II VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE I DESIGN ANALYSIS ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, a Maximum Station Flow: 10.40 gpm R=RED 360 ARC. I Flow Available at POC: 11.88 gpm j/2 aZIq _ Residual Flow Available: 1.48 gpm ® ® HUNTER MP800SR PROS-04-PRS40-CV 69 40 ADJ. 360 TURF ROTATOR, 4.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO Critical Station: 9 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND AREA FOR DRIP (NP.) 5.35 10 3/4" Friction Loss: 7 8.43 \-L.l J4 Fittings Loss: 0.21 psi ? HUNTER MP CORNER PROS-04-PRS40-CV 2 40 Elevation Loss: 0.00 psi 9 Loss through Valve: 11.55 psi , 2 VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. DZ Pressure Req. at Critical Station: ❑ A25.05 11 3 Loss for Fittings: 0.26 psi ° ° � 2.64 psi 3/4 ❑ 4 Loss for POC to Valve Elevation: 0.00 psi 5 5.80 MANUFACTURER/MODEL/DESCRIPTION ❑ 1" Loss for Backflow: - ° ° ° 3/4" a 113/4" 11. Loss for Water Meter: 4.20 12 ° ...a I a 3/4" ° o a 13/4„ 54.50 psi 0 DRIP CONTROL VALVE KIT. 1" PGV GLOBE VALVE WITH 1" HY100 FILTER Ia �� 4 a ° a II 6 8.57 Residual Pressure Available: 1„ 1 I GPM. 150 MESH STAINLESS STEEL SCREEN. / AREA TO RECEIVE DRIPLINE °a 4 a a EE EE 1 NO. I REVISION IRRIGATION SCHEDULE CRITICAL ANALYSIS SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI 1° A a a a a 7.48 13 I 3i4"a a j I d p I HUNTER PROS -02 5- STRIP SPRAY 18 30 ES LCS RCS CS SS � a I I 1 I IRRIGATION VALVE (TYP.) FLOW AVAILABLE ° I 1 ° °a ° 1 I I MAINLINE (TYP.) 3/4" 6.30 14 I I a ° a1 I Flow Available: 11.88 gpm HUNTER MP1000 PROS-04-PRS40-CV 2 ° a TURF ROTATOR, 4" (10.16 CM) POP-UP WITH CHECK VALVE, PRESSURE PRESSURE AVAILABLE Al REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. Static Pressure at POC: 86.00 psi M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE Elevation Change: 0.00 ft 360 ARC. Service Line Size: 3/4" Length of Service Line: SPRAY HEAD (TYP.) HUNTER MP2000 PROS-04-PRS40-CV 2 40 Pressure Available: 86.00 psi � II VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE DESIGN ANALYSIS ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, Maximum Station Flow: 10.40 gpm R=RED 360 ARC. Flow Available at POC: 11.88 gpm a ° a _ Residual Flow Available: 1.48 gpm ® ® HUNTER MP800SR PROS-04-PRS40-CV 69 40 ADJ. 360 TURF ROTATOR, 4.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO Critical Station: 9 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND Design Pressure: 30.00 psi GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) Friction Loss: 2.08 psi Fittings Loss: 0.21 psi ? HUNTER MP CORNER PROS-04-PRS40-CV 2 40 Elevation Loss: 0.00 psi TURF ROTATOR, 4" (10.16CM) POP-UP WITH FACTORY INSTALLED CHECK Loss through Valve: 11.55 psi VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. Pressure Req. at Critical Station: ❑ T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. Loss for Fittings: 0.26 psi ° ° � 2.64 psi 3/4 ❑ Loss for POC to Valve Elevation: 0.00 psi SYMBOL MANUFACTURER/MODEL/DESCRIPTION ❑ Loss for Backflow: 6.50 psi Loss for Water Meter: 1.26 psi HUNTER PCZ -101-25 8 Critical Station Pressure at POC: 54.50 psi 0 DRIP CONTROL VALVE KIT. 1" PGV GLOBE VALVE WITH 1" HY100 FILTER Pressure Available: 86.00 psi SYSTEM. PRESSURE REGULATION: 25PS1. FLOW RANGE: 0.5 GPM TO 15 Residual Pressure Available: 31.50 psi GPM. 150 MESH STAINLESS STEEL SCREEN. AREA TO RECEIVE DRIPLINE a HUNTER PLD -04-12 7,558 L.F. IN-LINE PRESSURE COMPENSATING LANDSCAPE DRIPLINE WITH BUILT-IN CHECK VALVE. 0.4 GPH EMITTERS AT 12" O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV 1„ RESISTANT. USE PLD -LOC FITTING OR BARBED FITTINGS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD PEB-PRS-D 6 1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION. WITH PRESSURE REGULATOR MODULE. - RAIN BIRD PSI-L3OX-075 2 CAN BE INSTALLED ABOVE OR BELOW THE GROUND.PRESET OUTLET PRESSURES: 30 PSI (2,0 BARS), 40 PSI (2,8 BARS). 3/4" (20/27) OR 1" (26/34) FEMALE -THREADED INLET AND OUTLET. a DRIP VALVE ASSEMBLY BF ZURN 350XL 3/4" 1 (TYP.) DOUBLE CHECK VALVE ASSEMBLY W/ EZSWAP INSERT. - 3/4 © HUNTER PHC-2400 1 QUICK COUPLER VALVE (TYP.) WI -FI ENABLED, FULL -FUNCTIONING CONTROLLER WITH TOUCHSCREEN, 24 -STATION FIXED CONTROLLER, 120 VAC, OUTDOOR MODEL. RS EE EE 1 NO. I REVISION IRRIGATION SCHEDULE CRITICAL ANALYSIS SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI P.O.C. NUMBER: 01 A a a a a Water Source Information: HUNTER PROS -02 5- STRIP SPRAY 18 30 ES LCS RCS CS SS TURF SPRAY, 2.0" POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT FLOW AVAILABLE MATERIAL. Water Meter Size: 3/4" Flow Available: 11.88 gpm HUNTER MP1000 PROS-04-PRS40-CV 2 40 TURF ROTATOR, 4" (10.16 CM) POP-UP WITH CHECK VALVE, PRESSURE PRESSURE AVAILABLE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. Static Pressure at POC: 86.00 psi M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE Elevation Change: 0.00 ft 360 ARC. Service Line Size: 3/4" Length of Service Line: 0.00 ft HUNTER MP2000 PROS-04-PRS40-CV 2 40 Pressure Available: 86.00 psi TURF ROTATOR, 4" (10.16 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE DESIGN ANALYSIS ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, Maximum Station Flow: 10.40 gpm R=RED 360 ARC. Flow Available at POC: 11.88 gpm Residual Flow Available: 1.48 gpm ® ® HUNTER MP800SR PROS-04-PRS40-CV 69 40 ADJ. 360 TURF ROTATOR, 4.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO Critical Station: 9 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND Design Pressure: 30.00 psi GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) Friction Loss: 2.08 psi Fittings Loss: 0.21 psi ? HUNTER MP CORNER PROS-04-PRS40-CV 2 40 Elevation Loss: 0.00 psi TURF ROTATOR, 4" (10.16CM) POP-UP WITH FACTORY INSTALLED CHECK Loss through Valve: 11.55 psi VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. Pressure Req. at Critical Station: 43.84 psi T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. Loss for Fittings: 0.26 psi Loss for Main Line: 2.64 psi Loss for POC to Valve Elevation: 0.00 psi SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Loss for Backflow: 6.50 psi Loss for Water Meter: 1.26 psi HUNTER PCZ -101-25 8 Critical Station Pressure at POC: 54.50 psi DRIP CONTROL VALVE KIT. 1" PGV GLOBE VALVE WITH 1" HY100 FILTER Pressure Available: 86.00 psi SYSTEM. PRESSURE REGULATION: 25PS1. FLOW RANGE: 0.5 GPM TO 15 Residual Pressure Available: 31.50 psi GPM. 150 MESH STAINLESS STEEL SCREEN. AREA TO RECEIVE DRIPLINE HUNTER PLD -04-12 7,558 L.F. IN-LINE PRESSURE COMPENSATING LANDSCAPE DRIPLINE WITH BUILT-IN CHECK VALVE. 0.4 GPH EMITTERS AT 12" O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. USE PLD -LOC FITTING OR BARBED FITTINGS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD PEB-PRS-D 6 1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION. WITH PRESSURE REGULATOR MODULE. - RAIN BIRD PSI-L3OX-075 2 CAN BE INSTALLED ABOVE OR BELOW THE GROUND.PRESET OUTLET PRESSURES: 30 PSI (2,0 BARS), 40 PSI (2,8 BARS). 3/4" (20/27) OR 1" (26/34) FEMALE -THREADED INLET AND OUTLET. DRIP VALVE ASSEMBLY BF ZURN 350XL 3/4" 1 (TYP.) DOUBLE CHECK VALVE ASSEMBLY W/ EZSWAP INSERT. © HUNTER PHC-2400 1 QUICK COUPLER VALVE (TYP.) WI -FI ENABLED, FULL -FUNCTIONING CONTROLLER WITH TOUCHSCREEN, 24 -STATION FIXED CONTROLLER, 120 VAC, OUTDOOR MODEL. RS HUNTER MWS -FR 1 WEATHER STATION WITH RAIN SENSOR, WIND SENSOR AND FREEZE SENSOR, 120 VAC, 5 AMP. 5 YEAR WARRANTY. WATER METER 3/4" 1 IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1,545 L.F. IRRIGATION MAINLINE: CPVC SCHEDULE 40 241.4 L.F. RAIN SENSOR- RAIN GUTTER MOUNT PIPE SLEEVE: PVC CLASS 200 SDR 21 292.2 L.F. (CONTRACTOR TO FIELD LOCATE) Valve Callout IRRIGATION CONTROLLER Valve Number (FIELD LOCATE NEAR A/C 110 POWER) # # = Valve Flow #" Valve Size VALVE SCHEDULE NUMBER MODEL SIZE TYPE GPM WIRE PSI PSI @ POC PRECIP 1 RAIN BIRD PEB-PRS-D 1" TURF SPRAY 7.80 112.4 33.74 42.80 2.49 in/h 2 RAIN BIRD PEB-PRS-D 1" TURF SPRAY 10.40 115.2 35.02 45.93 3.04 in/h 3 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 4.22 106.6 40.29 47.96 0.64 in/h 4 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 4.06 103.3 40.79 48.38 0.64 in/h 5 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 5.80 54.1 42.13 50.66 0.64 in/h 6 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 8.57 47.0 43.04 53.06 0.64 in/h 7 RAIN BIRD PEB-PRS-D 1" TURF ROTARY 8.43 52.1 43.27 53.18 1.33 in/h 8 RAIN BIRD PEB-PRS-D 1" TURF ROTARY 5.59 38.0 43.36 51.89 0.72 in/h 9 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 8.86 35.9 43.83 54.47 0.64 in/h 10 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 5.35 92.1 41.04 50.72 0.64 in/h 11 RAIN BIRD PEB-PRS-D 1" TURF ROTARY 5.05 90.2 43.96 53.30 1.27 in/h 12 RAIN BIRD PEB-PRS-D 1" TURF ROTARY 4.20 87.6 42.54 51.20 1.09 in/h 13 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 7.48 95.4 41.91 54.22 0.64 in/h 14 HUNTER PCZ -101-25 1" AREA FOR DRIPLINE 6.30 97.5 41.86 52.79 0.64 in/h Common Wire 241.4 NOTES - 0197375 1. IRRIGATION DESIGN IS SCHEMATIC: ALL IRRIGATION WORK TO BE PERFORMED WITHIN PLANTING BEDS EXCEPT FOR SLEEVING. SLEEVING RUNS SHOWN IN APPROXIMATE LOCATIONS,CONTRACTOR TO PLACE SLEEVES UNDER PAVED SURFACES AS SHOWN BASED ON SITE CONDITIONS AT TIME OF INSTALLATION. MAINLINE DISPLAYED FOR GRAPHICAL CLARITY. ACTUAL LOCATION TO BE DECIDED IN THE FIELD. 14711 NE 29th Place Suite 101 MAINLINE AND LATERALS MAY SHARE TRENCHING WHERE POSSIBLE. (SEE DETAIL ON L3.31) Bellevue, Washington 98007 425.885.7877 Fax 425.885.7963 DESIGN DCVA PROJECT NO. 16174T ENGINEERING PLANNING SURVEYING EXISTING WATER METER WILL BE REUSED AS NEW IRRIGATION WATER METER \ I � (POC #1) Q SS ® --__ IN COMPLIANCE WITH CITY OF RENTON STANDARDS STATE OF \ WASHINGTON , REGISTERED CURRENT PLANNING CAPE ARCHITECT mherrera 05/17/2018 LINDSEY BENNETT S RIO DEVELOPMENT ENGINEERING CERTIFICATE N0. 13 W 04/17/2020 mair 05/17/2018 SURVEYED' SCALE: VERTICDATE: DAP HORIZO TAL"NAD D1983/1991 DESIGNED LBS � ® CJY OF SEPT. 207 FIELDBOOK: RENTON DRAWN: ICA PLAY lily/p PAGE: LBS � � DRAWING N0 ONE INCH DATUM CHECKED: LBS AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH L3. 01 BY DATE AP P R APPROVED: B� SCALE ACCORDINGLY SHEET: ,8 OF: 22