HomeMy WebLinkAboutR-389617w Q Z U W O IL 00 Q0 00 0 0 U V) 7- Q N 0 0 N a� t= F- N 0 0 0 I O v N i C) 0 i O N 1-1 In CD O O N i N L.L CONSTRUCTION DETAILS EJ CONCRETE DEAD MAN BLOCKING WITH SHACKLE RODS TO 2" OPEN PATTERN, RETURN BEND - 180' 11-1/4' BEND 22-1/2* BEND 45' BEND CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED 2"GALVANIZED IRON PIPE FIELD EARTH, SIZE OF BLOCK TO BE DETERMINED BASED ON TEST LOCATE ;:1 PRESSURE OF WATER LINE AND SOIL CHARACTERISTICS. 2" 90' ELBOW CUT OPENING AS REQUIRED, AFTER t -o CAST IRON CAP OR PLUG WITH INSTALLATION, GROUT AROUND PIPE. F 2" IPS TAP SHALL BE A 2" UNION ROCKWELL 482 END CAP 2" BEEHIVE STRAINERCOUPLING. SHORT NIPPLE CAP2" GALVANIZED IRON PIPE 2" CLOSE NIPPLE D WATER MAIN � AS REQUIRED. z"x2"x2" TEE � 2" UNION TEE 17"x30" PLASTIC METER BOX EQUAL TO MID STATES W N Li rn a THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS FIRM SILT OR SOIL FIRM SILTY SAND COMPACT SAND COMPACT SAND & GRAVEL 90'45' BEND 11 1/4' 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND BEND BEND 4" 7.0 4.2 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 1.6 1.0 6" 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 16.7 6.7 11.7 8.4 8.4 3.4 8.8 6.3 6.3 2.5 12" 53.0 37.51 37.5 15.0 26.5 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-0" MIN. COVER FOR WATERMAIN LESS THAN 12". 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH �O w MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and PLASTIC, BCF SERIES 1730-18 WITH 2 THICK DUCTILE 2" CLOSE NIPPLE�/' 18„ IRON DIAMOND PLATE. 18"x31" MSCBC 173OR 2" 90° ELBOW 2" GALVANIZED IRON PIPE, 12" 2" BRONZE GATE VALVE, SCREWED EQUAL LONG. TO RED -WHITE VALVE CORP. FIG NO. 280 2" RESILIENT SEAT GATE VALVE WITH THREADED ENDS PLAN 2" 90' BENDS WITH CLOSE NIPPLE BETWEEN BENDS 2" GALVANIZED IRON PIPE TO FIT - °° CLOSE °o°° o° ° o 0 o NIPPLE 12" MIN. o o ° o ° °o 2 CORPORATION STOP 90' BEND, - Q. ° °o I.P. THREAD TO COPPER, EQUAL ° o °, TO FORD FB 500. 2" TYPE K SOFT COPPER TUBING TO FIT DOUDLE STRAP SERVICE CLAMP WITH 2" IPS TAP TO FIT, EQUAL TO MUELLER CO. TWO PIECE CAST IRON VALVE BOX VALVE NUT EXTENSION IF REQUIRED 2" 90' ELBOW DOUDLE STRAP SERVICE CLAMP WITH 2" WASHED GRAVEL, PASSING IPS TAP TO FIT, EQUAL TO MUELLER CO. EQUAL TO RICH VALVE CO. STANDARD (SEE DWG BR46 / PAGE B090) " 1-1 2AND RETAINED ON / AIR AND VACUUM VALVE 2" ASSEMBLY 8" TOP SECTION, WITH REGULAR INSTALL 2" 90' ELBOW, SCREWED 1/4" MESH FOR DRAIN APCO NO. 1452C OR EQUAL. �\ BASE SECTION LENGTH TO FIT. l _F 2" PLUG, SCREWED a q �• 2" GALVANIZED IRON PIPE 12" LONG 2" GALVANIZED IRON PIPE 8 4 0" \ �• AS REQUIRED. a �/� 2" RESILIENT GATE VALVE, SCREWED INSTALL 2° 90' ELBOW, THRUT BLOCe FA AREASREFERSKTOEARI G - SCREWED FACE OF BLOCK MEASURED IN SQUARE FEET 2" GALVANIZED IRON NOTES: PIPE AS REQUIRED. NOTE: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES ELEVATION AIR AND VACUUM RELEASE VALVE ASSEMBLY SHALL BE INSTALLED DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. AT HIGHEST POINT OF LINE. IF HIGH POINT FALLS IN A LOCATION WHERE ASSEMBLY CANNOT BE INSTALLED, PROVIDE ADDITIONAL DEPTH 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. OF LINE TO CREATE A HIGH POINT AT A LOCATION WHERE ASSEMBLY 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING CAN BE INSTALLED. SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. LOCATE AIR VACUUM METER BOX OUTSIDE OF TRAFFIC AREAS, IN 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/2"). PLANTING STRIPS, BEHIND CURB AND SIDEWALK. 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. • UtiaY PUBLIC WORKS • CONCRETE BLOCKING FOR STD. PLAN - 330.2 c�tiaY PUBLIC WORKS 2 BLOW -OFF STD. PLAN - 340.2 "1aY o' PUBLIC WORKS 2" AIR &VACUUM RELEASE STD. PLAN - 340.4 • � DEPARTMENT HORIZONTAL AND DOWNWARD A + DEPARTMENT TEMPORARY ASSEMBLY +``ate DEPARTMENT ASSEMBLY VERTICAL BENDS MARCH 2010 �� 1VT0� MARCH 2010 N�p� MARCH 2010 RESERVED PARKING (WHITE) (BLUE) 12% 18" SIGN TEXT ACCORDING TO LOCAL JURISDICTIONAL INSTALL SIGN PER CBC 1129B.4 a VAN ACCESSIBLE REQUIREMENTS 1. Provide a separate Curb Ramp for each marked or unmarked crosswalk. PEDESTRIAN CURB - Z � Q Y z¢zZ3 MIN- FINE 5250 Crosswalk, or as shown in the Contract Plans. / 2. Where "GRADE BREAK!' is called out, the entire length of the grade Y break between the two adjacent surface planes shall be flush. v 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurts- C nances in front of the Curb Ramp or on any part of the Curb Ramp or M_3� �3'R. �O w F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and DETECTABLE WARNING SURFACE - d Q 7 C:, S Za. O D O Z m ¢ o o t 0 O U D p +� O 3 m SYMBOL BACKGI w o- 0 N c.)mao ¢ m�o� HEIGHTS ACCORDING TO LOCAL REQUIREMENTS 36"x36" BLUE IF SIGN IS LOCATED IN PEDESTRIAN TRAFFIC, STENCILED SIGN LOCATE BOTTOM OF SIGN AT +6'-8" ABOVE = Ln V)N 1z IVWALKING SURFACE Parking Stall Stencil FLEXIBLE POST ON SHORT POLE INSTALLATIONS ZUMAR INDUSTRIES (800) 426-7927 OR 2"0 STEEL POLE ON INSTALLATIONS ABOVE 5'-0" Sign Parkin Accessible Parking Sign NOT TO SCALE 4'-0"MIN.- SEE CONTRACT PLANS" 318" EXPANSION JOINT SEE STANDARD PLAN F-30. LANDING 1 I L CURB AND GUTTER,-: J J W 0 0 J z U.1 LL m 4 - W MIN. -_ A SSE CONTRACT PLANS' PEDESTRIAN CURB - 318" EXPANSION JOINT� J SEE NOTE 9 SEE STANDARD PLAN LANDING ' L_- �' h rSIDEWALK s SIDEWALK Cq 4' - 0" MIN. (TYP.) - _/ L<: SEE CONTRACT PLANS I CURB RAMP CURB RAMP DETECTABLE WARNING SURFACE - FACE OF CURB SEE STANDARD PLAN F45.10 DEPRESSED CURB & GUTTER CROSSWALK CURB & GUTTER CURB RAMP 4' - 0" MIN. (TYP.) - SEE CONTRACT PLANS FACE OF CURB PLAN VIEW DETECTABLE WARNING SURFACE - TYPE PARALLEL A SEE STANDARD PLAN F-48.10 4'- V MIN. SEE CONTRACT PLANS 2.0%MAX. CEMENT CONCRETE PEDESTRIAN CURB - SEE NOTE 9 15'-0" MAX. 4'-0"MIN. SEE NOTE 7 SEE CONTRACT PLANS SIDEVWILK GRADE BREAK 8.3�i 2.0% MAX. v CURB RAMP Af - LANDING SECTION O 1&-0" MAX. SEE NOTE 7 GRADE BREAK LANDING 3/8" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 SECTION O "CEMENT CONCRETE CURB RAMP TYPE PARALLEL A" PAY LIMIT - SEE NOTE 6 T _- SEE STANDARD PLAN F-45.10 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and placement of sidewalk. i� DEPRESSED CURB & GUTTER 8, The Bid Item "Cement Concrete Curb p Type ype -" does not include the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. 7. The Curb Ramp maximum running slope shall not require the ramp length PLAN VIEW to exceed 15 feet to avoid chasing the slope indefinitely when connecting TYPE PARALLEL B to steep grades. When applying the 154bot max. length, the running slope of the curb ramp shall be as flat as feasible. GRADE BREAK 8. Curb Ramp, Landing, and Flares shall receive broom finish. See Standard Specifications 8-14. COUNTER SLOPE TOP of 9. Pedestrian Curb may be omitted if the ground surface at the back of the f 5AX ROADWAY Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will be no material to retain. DEPRESSED CURE 8 GUTTER - SEE STANDARD PLAN F-10.12 AND NOTE 6 15'- 0" MAX. _ 4' - 0" MIN. c.' . SEE NOTE 7 PEE CONTRACT PLAN0LEGEND SIDEWALK - - GRADE BREAK SLOPE IN EITHER DIRECTION GRADE B L83%[LMAXKWFTUK i 8.33 CURB RAMP LLANDING PEDESTRIAN CURB < 3/8" EXPANSION JOINT (TYP.) - SEE NOTE 9 r C L CURB RAMP SEE STANDARD PLAN F-30.10 SECTION O r ISOMETRIC VIEW TYPE PARALLEL A PAY LIMIT "CEMENT CONCRETE CURB RAMP TYPE PARALLEL B" PAY LIMIT - SEE NOTE 6 ISOMETRIC VIEW TYPE PARALLEL B PAY LIMIT SURVEYED: SCALE: DESIGNED: KEH DRAWN: RDC/KEH CHECKED: KEH N0. REVISION BY DATE APPR APPROVED: JGH � 4ATRlc� �0 *e 34363 e OI STO G1� 10 AL PARALLEL CURB RAMP STANDARD PLAN F-40.12-02 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Pasco Bakotich 111 6/20/13 UrATE DESIGN ENGINEER DATE T WDahinyron Stale Deporlm.nt of Tionspartalim VERTICAL: NAVD 1988 NA HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C TY OF RENTON Planning/Building/Public Works Dept. By: its By - By: RECOMMENDED FOR APPROVAL Date: z O (_n L Li �G,HA�� m� �z o n U 2�G CO Q- � �/NG E N G %XA 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES Ow CO avo 0- LUC7qRT W ~ � O in 9 F0 Cl) Q Zaw� 0QZw Z�� W0 0 Q ii O� GUY ,�J WAS Q ' � t� Z 38950 p �4 �NAE��ENG\��, 6/11/2018 NOTES 1. Provide a separate Curb Ramp for each marked or unmarked crosswalk. PEDESTRIAN CURB - Curb Ramp location shall be placed within the width of the associated SEE NOTE 9 Crosswalk, or as shown in the Contract Plans. / 2. Where "GRADE BREAK!' is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurts- C nances in front of the Curb Ramp or on any part of the Curb Ramp or Landing. �3'R. 4. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and DETECTABLE WARNING SURFACE - Pedestrian Curb details. SEE STANDARD PLAN F-45.10 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and placement of sidewalk. i� DEPRESSED CURB & GUTTER 8, The Bid Item "Cement Concrete Curb p Type ype -" does not include the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. 7. The Curb Ramp maximum running slope shall not require the ramp length PLAN VIEW to exceed 15 feet to avoid chasing the slope indefinitely when connecting TYPE PARALLEL B to steep grades. When applying the 154bot max. length, the running slope of the curb ramp shall be as flat as feasible. GRADE BREAK 8. Curb Ramp, Landing, and Flares shall receive broom finish. See Standard Specifications 8-14. COUNTER SLOPE TOP of 9. Pedestrian Curb may be omitted if the ground surface at the back of the f 5AX ROADWAY Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will be no material to retain. DEPRESSED CURE 8 GUTTER - SEE STANDARD PLAN F-10.12 AND NOTE 6 15'- 0" MAX. _ 4' - 0" MIN. c.' . SEE NOTE 7 PEE CONTRACT PLAN0LEGEND SIDEWALK - - GRADE BREAK SLOPE IN EITHER DIRECTION GRADE B L83%[LMAXKWFTUK i 8.33 CURB RAMP LLANDING PEDESTRIAN CURB < 3/8" EXPANSION JOINT (TYP.) - SEE NOTE 9 r C L CURB RAMP SEE STANDARD PLAN F-30.10 SECTION O r ISOMETRIC VIEW TYPE PARALLEL A PAY LIMIT "CEMENT CONCRETE CURB RAMP TYPE PARALLEL B" PAY LIMIT - SEE NOTE 6 ISOMETRIC VIEW TYPE PARALLEL B PAY LIMIT SURVEYED: SCALE: DESIGNED: KEH DRAWN: RDC/KEH CHECKED: KEH N0. REVISION BY DATE APPR APPROVED: JGH � 4ATRlc� �0 *e 34363 e OI STO G1� 10 AL PARALLEL CURB RAMP STANDARD PLAN F-40.12-02 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Pasco Bakotich 111 6/20/13 UrATE DESIGN ENGINEER DATE T WDahinyron Stale Deporlm.nt of Tionspartalim VERTICAL: NAVD 1988 NA HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C TY OF RENTON Planning/Building/Public Works Dept. By: its By - By: RECOMMENDED FOR APPROVAL Date: z O (_n L Li �G,HA�� m� �z o n U 2�G CO Q- � �/NG E N G %XA 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES Ow CO avo 0- LUC7qRT W ~ � O in 9 F0 Cl) Q Zaw� 0QZw Z�� W0 0 Q ii O� GUY ,�J WAS Q ' � t� Z 38950 p �4 �NAE��ENG\��, 6/11/2018 Project #: 12740 GGress: 4815 NE 4TH AVE RENTON, WA CONSTRUCTION DETAILS Date: Drowing No.: Date C20of 25 Date DATE: AS BUILT S TORAGE ONE ON 4TH EXPANSION Permit NO. U15008468 FIELDBOOK: PAGE: DRAWING NO: 4815 NE 4TH AVE E ET- OF- R -389617 w O O O N O O O O O CY) N CO LO 00 CN _ _ W W W W W W W Y z: T_ W W Y ED ED ED In z UJ M> w of 0 W _ U w H O Ln UJ V) Z W L LLJ V) H- O In LLJ Z U Z M U LLJ Fn O O 0 M U O U w Q W E 0 LLJ Z W OU of OJ of m w w LLJN Z �_ W w Of z F- Of F_ F_ O Q U 0' m D O O 3 N p Uof 1n Ll O o o O 0- J a U Q N U) U) > m w W W w L w of Q 0 o- O_ W W W Project #: 12740 GGress: 4815 NE 4TH AVE RENTON, WA CONSTRUCTION DETAILS Date: Drowing No.: Date C20of 25 Date DATE: AS BUILT S TORAGE ONE ON 4TH EXPANSION Permit NO. U15008468 FIELDBOOK: PAGE: DRAWING NO: 4815 NE 4TH AVE E ET- OF- R -389617